| 1 | L1₹76.1 LAccepted-AOC 54 AKASH DEEP COLONY CHAKRATA ROAD DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹78.0 L+₹1.9 L (2.48%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹85.3 L+₹9.2 L (12.1%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹85.5 L+₹9.3 L (12.3%)Rejected-Finance 340 11 M S NATIONAL ENGINEERING CORP 340 11 SATTI STREET ROORKEE ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹86.9 L+₹10.8 L (14.2%)Rejected-Finance LEKSHMI NIVAS TELANG ROAD NANDANGADDA KARWAR 581 304 | KARWAR | UTTARA KANNADA | KARNATAKA | 581304 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹90.5 L
EMD Value
₹1.6 L
Closing Date
27 Feb 2020, 6:00 pmClosed
SH M V SANKAR SE
CWE NAVY VASCO VASCO DA GAMA GOA 403802
PROVISION OF 750 KVA TRANSFORMER AND WATER SUPPLY FOR PROJECTION NCN SATELLITE DATA CENTRE AT NAVAL BASE KARWAR UNDER GE SB KARWAR
2020_MES_313409_1
85215/E8
Open Tender
Civil Works
Lump-sum
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE SB KARWAR
₹1.6 L
Yes
31 Mar 2020
9 Jan 2020
29 Feb 2020
9 Jan 2020
27 Feb 2020
13 Feb 2020
Amount
Total amount of Sch 'A' Part-I (BUILDING and STRUCTURES) brought forward from Serial Page No.25(R)
Total amount of Sch 'A' Part-II (SITE CLEARANCE, EXCAVATION AND EARTH WORK) brought forward from Serial Page No.27
Total amount of Sch 'A' Part-III (INTERNAL ELECTRIFI - CATION) brought forward from Serial Page No.29
Total amount of Sch 'A' Part-IV(EXTERNAL WATER SUPPLY ) brought forward from Serial Page No.30
Total amount of Sch 'A' Part-V (EXTERNAL ELECTRIFICATION ) brought forward from Serial Page No.40
Sch 'A' Part- VI - MISCELLANEOUS ITEMS Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Internal electrification
Supply and fix Integral sleek extruded polycarbonate batten for LED tube light with white acrlyic cover suitable for upto 1x22 watts LED tube light all as specified and as directed. Make : Havells Cat No.REGALBATTEN8 UPTO 1X22W DSBSWH or equivalent in Bajaj/CG
Supply and fix LED tube rod 20 watt, 6500 K, 1200 mm long complete all as specified and as directed. Make : Havells Cat No CRYSTAL1213T8DSTL20W LED 865SGLASS or equivalent in Bajaj/CG
S&F Switch piano 6 Amps one way flush type all as specified and as directed. Make : Havells REO Cat No AHESXXW061 or equivalent in Anchor/Legrand
Supply and fix switch socket combination 2 in 1, 5 pin, 5 Amps flush type, make ISI marked, all as specified and as directed.
Supply and fix switch socket combination 5 Amps/16 Amps,5 in 1, flush type, multi purpose make ISI marked, all as specified and as directed.
M & L for sub main wiring with two runs of single core PVC insulated FRLS unsheathed suitable for 1100 volts multistranded copper conductor conforming to IS 694-1990 with ISI marking cable of size 6 sqmm and one run of 1100 V grade PVC insulated FRLS unsheathed 6.00 sqmm multistranded copper conductor cable 1100 volts as in continuous earth drawn in and including surface PVC conduit medium grade 20 mm bore and accesories of suitable size complete for sub main wiring in walls/roof complete all as specified and as directed. Notes :- Three runs of cable 6.00 sqmm and one run of PVC conduit pipe shall be measured as one running meter unit
Supply and fix MCB Distribution Board, single pole and neutral, 240 Volts, 8 way, double door powder coated steel sheet enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed. Make : INDOASIAN Cat part No 811807 or equivalent as approved by GE
Supply and fix MCB single pole and neutral , 6-32 Amp, 230 Volts, 'C' series, single phase, 10KA capacity complete all as specified and directed. Make : INDOASIAN Cat part No 811151 or equivalent as approved by GE
Supply and fix MCB single pole , 6-32 Amp, 230 Volts, 'C' series, single phase, 10KA capacity complete all as specified and directed. Make : INDOASIAN Cat part No 811129 or equivalent as approved by GE
Supply and fix exhaust fan of 300 mm sweep, after assembling at site including electric connection from ceiling rose to connector with flexible cord twin core twisted copper of size 23/0.0076 and testing complete all as specified and as directed.
S&F LED 45 Watt street light luminaire, pressure die cast housing with toughned glass, IP-66 protection with high power LEDs as light source and electronic driver of 90 W capacity, making necessary connection complete all as specified and as directed. Make : Havells cat no ENDURACITY LINEREXGENS LED757SASYBOPC or equivalent in Philips/Havells/C&S
External water supply
S&F cast iron sluice valve of size 100 mm flanged PN-1.6 ISI conforming to IS :14846 hand wheel operated, stainless steel stem with gun metal parts flanged driller to IS: 1538 non rising stem PN-1.6 in existing main water pipe line of size 100 mm dia including cutting, jointing and jointing material etc as per site requirement complete all as specified and as directed.
Cutting the existing DI pipe line 100 mm dia bore and inserting one tee 100mm x 100mm x 40mm including connecting pipes, collers etc complete including necessary excavation and earthwork complete all as specified and directed.
M&L for construction of valve pit chamber 100 cm x 100 cm x 100 cm internal dimension with 10 cm thick foundation using PCC 1:4:8 type D-2 over 10 cm thick hardcore, 20 cm thick PCC block wall built in cement and sand motor 1:4,15 mm thick internal plaster including top of floor in cement and sand motor 1:5, finished even and smooth, with out using extra cement, 1.4 mm thick MS sheet cover with 20x20x4 mm flat iron hold fast, hinges, handle, locking arrangement and applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface including disposal of surplus soil of to a distance of n.exc 50 m complete all as specified and directed.
External electric supply
Supply, installation, testing and commissioning of three phase four wire, 415 Volts indoor type factory made free standing floor mounting double door, dust and vermin proof cubical type, Feeder Pillar box fabricated out 2.0 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalized design with 03 Nos of bus bars for phases and 01 No. bus bar for neutral, each made of high conductivity 99.9% pure copper of ETP grade suitable for 1600 Amps for phases and 800 amps for neutral and pre-wired with suitable size of copper cable/insulated copper strip having short circuit rating 50 KA (rms) for one second including suitable aluminium earth strips all as specified with supply and fixing the following :-
(b) Outgoing (i) ACBs 1250 Amps, 4 pole, 415 volts, 50 Hz AC, manual draw out type with microprocessor release with over load protection , earth fault protection - 01 Nos (ii) 400 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 36 KA, with adjustable load setting - 01 No (iii) MCB TPN 63 Amps , 415 Volt , 10 KA rupturing capacity - 02 Nos
Supply and fixing Electrical Insulating mat as per IS 15652:2006, Class B type, Min Thickness 2.5 mm. Dielectric strength/test potential shall be 45 kV & working potential shall be 11 kV. Insulating mat shall be resistant to acid and oil and low temperature and marked with respective class symbol. Upper surface of the insulating mats shall have small aberration (rough surface without edges)/ dotted to avoid slippery effects complete all as specified and directed.
Supply and fixing Electrical Insulating mat as per IS 15652:2006, Class A type, Min Thickness 2.0 mm. Dielectric strength/test potential shall be 30 kV & working potential shall be 3.3 kV. Insulating mat shall be resistant to acid and oil and low temperature and marked with respective class symbol. Upper surface of the insulating mats shall have small aberration (rough surface without edges)/ dotted to avoid slippery effects complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.5 meter below normal ground level (with top edge of earth plate not less than 1.75 meter below ground level) connected to GI strip 32x6 mm main earthing lead by means of galvanized bolts, nuts and washers with connected to earth test point & to main switch board /panel etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI medium grade earth lead protection pipe, complete all as specified and directed.
KVL CONSTRUCTION
M/S MANOJKUMAR M NAGARKATTE
NATIONAL ENGINEERING CORPORATION
LEKSHMI ENGINEERS
Veer High Tech Solution
Shree Ayyappa Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .