| 1 | L1₹5.3 CrAccepted-AOC NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹5.3 Cr | L1 | Accepted-AOC Being L1 Bidder |
Tender Value
₹5.7 Cr
EMD Value
₹6.1 L
Closing Date
18 Apr 2024, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
WORK SERVICES FOR PROVISION OF OKA-E1 TEST BENCH AT AFS CHABUA
2024_MES_638310_2
88649/CHAB/E8
Open Tender
Civil Works
Lump-sum
545 days
GE AF CHABUA
As per NIT Conditions
8 documents required · 8 mandatory
₹3,000
GE AF CHABUA
₹6.1 L
Yes
18 Jun 2024
23 Mar 2024
20 Apr 2024
23 Mar 2024
18 Apr 2024
6 Apr 2024
Amount
SCHEDULE "A" PART- IA (BUILDINGS/STRUCTURES WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IB Construction of one block of PEB Steel Structure Covered Shed with gantry provision and with Proposed RCC Retaining Wall on 3 sides of building, earth traverse and filling behind RCC Retaining Wall upto toe wall and Hard Standing, Ramp, PQC flooring including demolition of existing PCC flooring including excavation and earth work inside Shed and configuration with permanent specification, RCC framed construction, ATT, seismic provisions etc all as specified, directed and shown in drawings. Note:- Rates for RCC retaining wall, Earthern Traverse and earth filling upto toe wall for the structure shown separately in the main drawing and not forming integral part of Covered Shed shall be deemed to be included in quoted rates.
SCHEDULE "A" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV ( INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- V (PQC ROAD/FOOTH PATH ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VIII (SPECIAL B/R ITEMS ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IX (DEMOLITION OF EXISTING EARTHEN TRAVERSE ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- X (STATIC WATER TANK ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XI (EXTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XII (EXTERNAL ELECTRIFICATION ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XIII (LIGHTENING PROTECTION ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XIV (FIRE ALARM ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART -XV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
INTERNAL ELECTRIFICATION S & F Exhaust Fan 225 mm sweep flame proof type with cutting of chases by making hole to the existing wall, making good to the disturbed surface as per existing including connecting with suitable size of copper conducting wire up to nearest ceiling rose complete all as specified and directed.
Supply and fixing LED Flameproof Highbay Lights Colour Temperature 3000-5000 K, 50 Hz with aluminium body, cool white lighting for industrial applications complete all as specified and directed.
S&F Flame proof sheet metal enclosure for MCB SPN Double door DB 6-way, 250V with 200Amp rated bus bar, neutral link, din rail suitable for mounting MCBs complete all as specified and as directed. (Note: MCBs shall be measured and paid under separate item)
S&F Flame proof sheet metal enclosure for MCB SPN Double door DB 4-way, 250V with 200Amp rated bus bar, neutral link, din rail suitable for mounting MCBs complete all as specified and as directed. (Note: MCBs shall be measured and paid under separate item)
INTERNAL WATER SUPPLY Supply and fixing for 15mm bore angle stop cock cast copper alloy CP with long shank and cup. fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and as directed
PQC ROAD/FOOTH PATH M&L for Construction of brick masonary culvert of span 1.20 m and 8.82 M long including exavation,PCC(1:4:8) type D-2 in foundation,brick work in CM(1:6),RCC M25 (Design Mix) all as shown on drawing complete all as specified and directed.
SEWAGE DISPOSAL Construction of LLDPE Septick tank 2000 ltr conventional type, designed to carry out sewage and sludge water, excavation in any type of soil including removing and returning filling, PCC 1:4:8 below foundation, vent, shaft connection etc all as per manufacturers' instruction and complete all as specified.
M & L for Construction of Soakage Well - Excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM,RCC cover slab in M25/SFRC cover,interconecting pipes of RCC/DWC complete filled with brick bats of size 1.20 X 3.00 m effective depth complete all as specified and as shown on drawings.
STATIC WATER TANK M&L for 3mmX250mm wide PVC water stopper bar at construction joint in RCC wall of SWT complete all as specified and directed
M&L for laying Epoxy sealing compound at construction joint in RCC wall of SWT complete all as specified and directed
EXTERNAL WATER SUPPLY Materials and labour for construction of brick masonry valve pit of internal dimension 90 x 90 x 90 cm depth with sub class new 'B' bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron 4 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and and directed.
EXTERNAL ELECTRIFICATION S & F of 45 Watt LED streetlight made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, iP66 protection, impact resistance of iK07 & 10 KV external SPD complete all as specified and directed
Supply and fix street light bracket made out of 50 mm bore, galvanised iron, light grade tubing (approx 1.5 mtr in length) including necessary two nos suitable size of clamps with nuts, bolts and washers, etc. and two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed.
S&F Cable Junction Box 205X255X112mm in size, made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 nos) and one no MCB SP 6 amps complete fixed on poles with flat aluminium clamps of size 20x3mm, nuts, bolts, washers etc. cable junction box complete all as directed.
Supply , install, testing and commissioning of cubical housing cabinet type LT feeder pillar box of size 1000 mm x 1000 mm x 600 mm outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved and built upon 50 x 50 x 6 mm size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. Necessary foundation work as required at site and comprising following. BUS BAR (a) Electrolytic grade high conductivity TP&N solid copper bus bars, rated 100 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 Nos INDICATING DEVICES (a) LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 CONTROLS (a) MCCB 4 pole 40 Amp, fixed electrical. (Incoming) - 01 No. (b) MCCB 4 pole 25 Amp, fixed electrical. (Outgoing) - 03 Nos.
Earthing complete with GI plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 32×6mm GI strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, copper earthing strip shall be protected by 40mm bore light grade galvanised iron pipe, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness ) all around the earth electrode with concrete earth pit in PCC (1:3:6) type C-1 cast iron frame 50mm thick precast RCC 1:2:4 type B1 cover slab set in CM 1:4, reinforced with 8mm dia TMT bar 10cm C/C and suitable handle of 10mm dia round bar incl necessary excavation earth work in soft/loose soil and disposal of soil to distance n.exc 50m and necessary testing complete all as shown in electrical plate No. 3 of MES SSR Part I 2009.(Note : Earth lead and 20mm dia GI protection pipe upto 7.50m lenth shall be measured in this item)
Earthing complete with copper earth plate electrode 60×60cm× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, copper earthing strip shall be protected by 40mm bore light grade galvanised iron pipe, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness ) all around the earth electrode with concrete earth pit in PCC (1:3:6) type C-1 cast iron frame 50mm thick precast RCC 1:2:4 type B1 cover slab set in CM 1:4, reinforced with 8mm dia TMT bar 10cm C/C and suitable handle of 10mm dia round bar incl necessary excavation earth work in soft/loose soil and disposal of soil to distance n.exc 50m and necessary testing complete all as shown in electrical plate No. 3 of MES SSR Part I 2009.(Note : Earth lead and 20mm dia GI protection pipe upto 7.50m lenth shall be measured in this item)
FIRE ALARM Supply and installing the flowchart based programmable RTU along with battery back up for incase of power fail SMS and Wireless modem suitable for GSM/GPRS based communication system; to be mounted in RTU enclosure - Input Out put as per requirement in our system - 3 serial port - Digital inputs (optical isolation) - Digital outputs -Isolated Analog Inputs -Local Display, membrane key board and data storage -Compatibility with GSM Modem --isolation transformer for RTU protection- 1 nos. NOTE : One panel in each FACP and one panel for fire section with mimik panel.
Supply and installing the Mimic Panel Using LED indicator For fault and Fire Alarm Monitoring all as specified and as directed.
Supply & Fixing of of three core copper conductor of size 2.5 sq mm FRLSZH Flexible shieathed cable (50 mtrs for each location) all as specified and as directed.
Supply & Fixing of of Two core copper conductor of size 1.5 sq mm FRLSZH Flexible shieathed cable. (5 mtrs per detectors & devices) all as specified and as directed.
STAND BY DG SET Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 30 KVA, water cooled, 415 Volts (AC Three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base tame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Chabua. (Capacity of Engine, alternators shall be worked out taking all de-rating factors into consideration including PCC foundation of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:- (i) ENGINE (Prime Mover): Diesel Engine 1500 RPM , direct injection ,6 cylinders ,four stroke, confirming to ISO 3046/BS 5514, water/ Air cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 30 KVA at outdoor atmospheric conditions at Chabua. (Taking all de-rating factor into consideration), , 12/24 Volt(as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with technometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc.
Condt from Item No.38.00 here-in-before (h) MCCB 415 Volts, 40 Amp, rating 4 Pole 18 KA rupturing capacity, Microprocessor based release, Specially fixed for incoming supply with overload, short circuit and earth fault protection — 2Nos (Outgoing). (v) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002. (vi) FOUNDATION/PLINTH/BASE: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M (vii) External cubicle Diesel storage tank of Capacity adequate for storage of diesel for 12 hours operation of Gen Set. (viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.
Condt from Item No.38.00 here-in-before Notes: (i) The unit rate includes for protection pipe and earth lead upto 7.50 meter. (ii) Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured separately. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit and the extra cost of additional height of watering pipe bends elbow etc shall be deemed to be included in the unit rate. (iv) All earthing should be interconnected. Earth lead for interconnection shall be measured and paid separately under relevant item. (v) Factory test shall be carried out by Testing Officer nominated by Accepting Officer. (vi) Pre-commissioning test shall be carried out by Testing Officer nominated by Accepting Officer. (vii) Fuel and artificial load for testing shill be arranged by contractor at his own cost. The cost of load and fuel and transportation shall be included in unit quoted rate.
Supply, Installation, testing & Commissioning of Silent Diesel Engine Generating Set complete all as per item No 38.00 here-in-before but of capacity 20 KVA
CRANE Design, Supply, install, commissioning and testing of flameproof EOT Crane duly class M5, Double girder type having span of 15 meter, long travel 18 m , hook height 4.5 m and weight lifting capacity 5 Ton considering the following conditions complete all as specified and directed :- (i) Internal dimension of bldg is 18m X 15m X 5.9M. (ii) Clear hook height available from FFL is 4.5m. (iii) The operation and micro speed of crane should be as following: (a) Main Hoist:- 3-4 meter/min (b) Micro in main Hoist - 0.3-0.4 meter/min (c) Cross travel – 5 meter/min (d) Micro in cross travel - 0.5 meter/min (e) Long travel - 10-15 meter/min (f) Micro in long travel – 1 meter/min (iv) EOT crane fitted should be fire/flame proof and comply with the safety specification given in the STEC PAMPHLET No. 7. (v) EOT crane fittings should be comply with the safety specification such as limit switches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete etc confirming to IS-807, IS-3177, IS-3938 specifications. (vi) Design, supply, installation, testing and commissioning of crane shall be undertaken through manufactures/ specialist firms. (vii) Design of crane and proof checking of design from any of chartered Engineers within 2 months from the date of acceptance of tender. (viii) Crane fabricator to verify the exact internal dimensions of the building physically before starting fabrication of the crane. (ix) VVVF Drive to be provided.
Condt from Item No.43.00 here-in-before Notes:- 1. The designs and drawings of the cranes shall be vetted by Indian Institute of Technology (IIT) 2. The actual span of the crane shall be taken from the site before fabrication. 3. The rails shall be aligned and leveled for smooth operation. 4. The cranes shall be tested for 125% overload and the deflection shall be as per IS by rep of Accepting Officer 5. After installation of crane at site, the crane shall be tested by rep of Accepting Officer 6. The contractor shall take the physical dimensions before fabrication of the crane and its members 7. Pre-dispatch inspection at OEM factory premises shall be carried out by Rep of Accepting officer.
Air-conditioning Design, Supply, Installation, Testing and commissioning of Temperature and humidity Monitoring system consisting of the following items: " Flowchart based programmable Remote Terminal Unit along with battery back up for incase of power fail SMS to engineer in-charge - Input Out put as per requirement in our system - 3 serial port - Digital inputs (optical isolation) - Digital outputs -Isolated Analog Inputs for monitoring of Temperature & humidity -Local Display, membrane key board and data storage -Compatibility with GSM Modem "MS Powder coated CRCA sheet of 3 mm Thickness Outdoor Panel of minimum size 600 x600 x 300 mm for indicator and Isolation transformer for RTU protection.Primary Side : Input : 0 -230 380 - 415 - 460 AC Secondary Side :output : 230 AC To protect voltage fluctuation & provide isolation "Wireless modem suitable for GSM/GPRS based communication system; to be mounted in RTU enclosure . - 02 Nos (TO BE INSTALLED AT ONE MODEM IN RTU PANEL AND ONE MODEM AT MCS)" "Resistant Temperature Detector (RTD) Sensor with Transmitter (Signal Converter), range 0°C to 200°C, accuracy Class ‘B’ (Tolerance as per IEC 751) and humidity sensor with transmitter (Signal Converter), working range 0°C to 50°C & 0-100%RH , transmitter output 4- 20mA (two wire), accuracy at 25°C ± 2% RH (0 to 90%) ; ± 3% RH (90 to 100%), , suitable for measurement of room & Duct temperature and humidity , complete.Masibus/Honeywell - 04 Nos
Condt from Item No.45.00 here-in-before "Process Indicator of 48x48 mm with retransmission output for monitoring of temperature and humidity. - 08 Nos (TO BE INSTALLED WITH RTU PANEL FOR INDICATION OF TEMPRETURE AND HUMIDITY) Surface mounted,humidity sensor with transmitter (signal converter) working range 0 degree c to 50 degree & 0-100% RH, transimitter output 4-20mA (two wire), Accuracy at 25 Deg C +/-2% RH (0 to 90%):+/-3% RH (90 to 100%), suitable for measurement of Humidity inside room complete. - 04 Nos "2Cx1.5 sq mm PVC coated Armoured Copper control cable as per requirement "Process Indicator of 48x48 mm with retransmission output for monitoring of temperature and humidity. - 08 Nos (TO BE INSTALLED WITH RTU PANEL FOR INDICATION OF TEMPRETURE AND HUMIDITY) GI Cable tray of required size and lenght "Master control Station Intel Core i3 Processor or equivalent at minimum 2.00 GHz ( 2 MB L2 cache ) , Intel Server Based Motherboard with minimum 800 Mhz BUS Speed , 2 GB DDR 2 SDRAM@ 667 Mhz , 160 GB SATA HDD , DVD Writer , 2 x USB 2.0, 2 xSerial Port, Gigabyte LAN 23"" TFT Display Monitor with Resolution of 1440 x 900 Pixel and Support 16.2M Color with required software License verson software windows-7, MS Office and antivirus Software. "UPS-600VA, 230 V AC, 30 min Backup. Laser Printer with Scanner A4 B & W
Condt from Item No.45.00 here-in-before "Front End Processor (FEP) - ARM 9 PROCESSOR 32 bit micro controller 512 MB memory 64 MB data memory with real time clock & 16 x 2 line LCD display,2 USB 2.0 ports IS standard , 5-300 Hz communication protocol suitable to GSM mode communication for Master control Station "Supervisory Control and Data Accusition (SCADA) software with required 6400 tags for Central Monitoring and control through wireless communication for Master Control Station, including programming liberty generation, soft keys etc.for graphical display of parameters for control and password protection, complete. GSM Sim Card Rental and SMS charges for the period of TWO year. - 2 No. of SIM CARD . Note:- (i) The rate is inclusive of designing of SCADA system for temperature and humidity (indoor/ outdoor) alongwith obtaining approval from IIT/ NIT. (ii) The parameter/ features shown are for guideline only. The specifications suggested by Govt approved Charted Engineer and approved by Accepting Officer shall surpassed the specifications mentioned above and rates for the same are deemed to be inclusive in quoted rates.
Supply, install, commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, three phase, 440 volt, 50 Hz, made out of SS/MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with SS/MS/CRCA 18 gauge square perforated suction grills, aluminium alloy fans and Flame proof 3 phase electric motor alongwith Motion Sensor, nozzles, etc, complete with fittings and acessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening 4000 mm x 4000 mm, complete all as specified and directed.
SPECIAL B/R ITEMS S & F for powder coated aluminium door with shutter, chowkhats/frame made with aluminium section of size 100 x 445 x 2 mm thk, vertical of shutters made with sections 84 x 44 x 2 mm thk, top/middle/bottom rail of shutter with section 112 x 44 x 2 mm thk, including tinted glass of 5 mm thick panes, insets including necessary fixing arrangement, joining cleats, glazing clips, rubber packing aluminium anodised beading screws etc, floor hinges, skelton tower bolt 300 mm size, mortice lock 100 mm size 4 lever , round handles etc, fitted to shutters and frames fixed in opening with aluminium hold fast of 25 x 3 mm flat 150 mm long 6 Nos in each frame incl cutting holes in brick work and embedded in PCC 1:2:4 bed block of size 150 x 150 x 150 mm each and match the existing, all in sliding type, in two panels, sliding to both sides in channels with wheel assembly rolled in channel at both top and bottom, in channel / railis inserted in fioor, and all suitable for fixing in clear opening of size 4.00 x 4.00 m complete all as specified and directed.
M & L Cutting old construction joint size 20mm x 50mm by mechanical cutter, cleaning the joints to remove all loose dust, dirt, oil and grease. The excessive laitance be removed by vaccum cleaning . Applying epoxy primer Nitoprime 25 and filling the joint in two part with epoxy resin primer Nitflor TF5000 or equivalent and then laying 3 to 6 mm screed by trowel to achieve all the tests complete all as specified and directed.
M&L for Preparation/cleaning the old flooring surface, making the surface contamination free such as oil, grease, mortar and paint splashes by grinding the surface and scrifying the whole surface. All surface should be made dust, free by vaccum and cleaning the same. The Process to be completed with following steps :- (a) Application of primer : Supply and application of primer Nitoprime 25, after thoroughly mixing the base and hardener using a heavy duty slow speed drilling machine fitted with a paddle until a homogeneous mix is obtained, over the prepared surface to in a thin continuous film using a stiff brush/roller. (b) Application of Screed : Supply and application of Nitoflor TF5000 screed after mixing the base, hardener, and filler until a homogeneous, lump free mix is obtained. The mixed hardener material is poured on the primed surface and spread slowly and evenly to a thickness of 3 mm using a serrated steel trowel. The material should be tamped with a wooden float to ensure complete compaction and finally finished to a closed even texture using a steel trowel. Screeding rods are useful to maintain a minimum compacted thickness of 3 mm. The flooring system will have compressive strength of 70 N/mm2 with tensile strength 14 N/mm2 with flexural strength 25 N/mm2. (c) Providing Earthing : After the primer has achieved a tack free state, apply proper earthing and joint connections
Condt from Item No.51.00 here-in-before (d) Application of Undercoat : Supply and application of Nitoflor SL Conductive Undercoat, after mixing the base and hardener thoroughly as described above, over the primed surface using roller/brush @ 6-7 m2 per kg (e) Application of Topcoat : Supply and application of Nitoflor SL Conductive Topcoat, after mixing the base, hardener, colour paste and filler until a homogeneous, lump free mix is obtained. The mixed material is poured on the primed surface and spread slowly and evenly to a thickness of 2 mm using a serrated steel trowel. Immediately after spreading, the floor should be firmly rolled with a spike roller to release any entrapped air and level any slight trowel marks. The flooring system will have compressive strength of 50 N/mm2 with tensile strength 16 N/mm2 with flexural strength 34 N/mm2 and temperature resistance upto 80 degree centigrade.
Note:- Schedule of credit (Sch 'A' Part- XVI) amount of Rs 1,52,177.10 shall be deducted from the total quoted amount of BOQ.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .