Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Not Qualifies |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
21 Jul 2023, 4:00 pmClosed
Executive Engineer Electrical
SKIMS Soura
Providing and Fixing of Cable Stands and Cable Trays at Various Areas of SKIMS MCH Bemina
2023_SKIMS_216835_1
eNIT NO.SIMS/HEE/E/ET/12 of 2023-24 Dt. 15-06-2023
Open Tender
Electrical Works
Item Rate
60 days
SKIMS MCH Bemina
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
CAO SKIMS MCH Bemina
₹24,000
28 Jul 2023
15 Jun 2023
22 Jul 2023
15 Jun 2023
21 Jul 2023
15 Jun 2023
Amount
Design /Construction of Over Head Cable Bridge and Stands near Principals Office & Lecture Hall stairs
Design,supply,fabrication and erection of M.S. steel structure (Horizontally across Road )from angle iron (50x50x6 mm)of suitable sizes to support the cable tray duly taking into consideration of the wind load/pressure at the site etc. excluding the cost of civil foundations as required. The structure shall be given primer coat and two coats of enamel painting. 200kgs for each bridge , As Such FOR 02 No. OF Bridges
Design,supply,fabrication and erection of G.I Pipe 150mm dia. 6.3mm thick having wt of pipe = 25kg/mtr excluding the cost of civil foundations as required . 30 meter for each bridge. As Such FOR 02 No. OF Bridges
Design,supply,fabrication and erection of M.S. Plate 12mm thick width 250mm having wt = 20kg/mtr to be fixed at the base of G.I Pipe structure and over surface of RCC and to be fixed with G.I bolts and welding etc as per requirement. The structure shall be given primer coat and two coats of enamel painting. 50 kgs for each bridge. As Such FOR 02 No. OF Bridges
Design,supply,fabrication and erection of ISMB (200x125x72)mm wt =31kg/mtr thicknes 7mm for laying horizontally for making bridge between pipe structure for laying of cables trays and cables.The structure shall be given primer coat and two coats of enamel painting. 800 kgs for each bridge. As Such FOR 02 No. OF Bridges
Contruction Of RCC bed for 13 mtr cable Bridge (1.0 m X 1.0m X 2 mtr)
a) Earth work excavation manually inculding disposal of earth as directed within SKIMS MCH permises=1.0 m x 1.0 m X 2.0 m = 2.0 Cum x 2 Nos
b) P/L of stone soling of specified size including Cost & carraige of material complete, x2 Nos
c) P/L of R.C.C work 1:2:4 mix including cost and carriage of material 1 m x 1m x 2m = 2.0 cum x 2 Nos
d) P/L of steel reinforcement (TMT) 12mm dia including cost of cutting, bending ,binding including cost binding wire Qty vide item (d) =4.0cum @ 35 kg/cum. As such 2 Nos.
e) Shuttering by steel plates/ wooden planks including removal of same after use and finishing of outer surface of bed. As such nos 2 Nos.
Supplying and installing 750mm width x 62.5 mm depth x2.0 mm thickness size of perforated Hot Dippped Galvanised Iron Cable tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5% , in convenient sections, joined with connectors , to be laid and fixed over ISM bridge with G.I ties etc as required.
Extraction from existing stands and again laying and fixing one number PVC of cables insulated and PVC Sheathed /XLPE power cable of 1.1 grade of above 185 mm2 and upto 400 mm2 size on cable tray/H-Frame structures as required and from:- 1. Principals Office upto Lecture hall. 2. from lecture halls upto Covid-19 Lab.
a)Design,supply,fabrication and erection of M.S. steel structure H- frame all along the cable routes whereever required. Wt of each frame= 13kgs each as such 30 Nos:- 1. From IPD electric control room upto car parking tin shed. 2. From Principals Office upto Lecture Halls. b)Design,supply,fabrication and erection of M.S. steel structure (100x50 x6mm) H- frame along the cable routes. Wt of each frame= 20 kgs each 1200mm height As such 4 Nos:-(LxWxH)=( 4' x 5' x 4'). 1. From M.S office to M.K Kiosk Panel
Making of earthing point with 2 inch dia GI pipe , B class , caged in 6 inch GI pipe , class B in CCM compound and 10 feet Deep, as earthing electrode . The pit is to be dug using borewell and covered with 10X10 inch manhole cover for earthing of Cable bridge and stands.
Dismantling of Existing 07 Mtrs 04 No poles and allied M.S Steel near Principals Office & near Lecture halls and dumping of same at Electrical Sub Store.
Shifting of different size of L.T. cables on Cable trays and Stands from M.S. Office to M.K Panel Near Entrance Gate of M.S. Office upto MRD Registration Counter.
Supply of Cotton Rope 3/4" size for temporary Handling & lifting of LT cables for making of cable Steel structure
Supply and erection of 100mmx50mmx 6mm channel iron for steel structure for laying of LT cables including drilling holes & nuts and bolts and painting one coat of red Oxide and minimum two coats of silver Paint as required at site.( To be fabricated as per drawing /requirement at site)size; 1.)7'x12 nos = 84 feet, 11'x2 nos =22 feet, 10.5x 4 nos = 42 feet, 0.5x6nos = 3 feet & 0.33'x6nos = 2 feet (Total 267 feet) (81.38 mtrs) weight per mtr= 7.9kg.= total kgs= 642 kgs 2.) 3'x16 nos = 48 feet, 5'.2''x 8 nos =42 feet, 15mtr = 2Nos (Total 140 feet) (42.67 mtrs) weight per mtr= 7.9kg=total kgs = 337 kgs.
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto ground level with: (Same as item no. 5.3)
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) ( for six posts) size 12"x12"x18". For H frames and pipe structres.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 185 sq.mm and upto 400 sq.mm
185 sq. mm. = 03 nos (27 mtrs), 300 sq. mm = 03 nos (50 mtrs) 400 sq. mm = 03 nos ( 50 mtrs)= ~ 380mtrs
Supplying and installing 750mm width x 62.5 mm depth x2.0 mm thickness size of perforated Hot Dippped Galvanised Iron Cable tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5% , in convenient sections, joined with connectors , to be laid and fixed over M.S Steel Structure with G.I ties etc as required.( Same as item no. 06 )
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (Horizontal/vertical) for above mentioned cable tray with galvanisation not less than 50 microns)with perforation not more than 17.5%, in convenient sections, etc. as required.
Millinnem EnterPrises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .