| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83.9 LAccepted-AOC SUBHASH CHOWK BARMER RAJSTHAN 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC quoted lowest rate | |
| 2 | L2₹87.8 L+₹3.7 L (4.35%)Rejected-Finance 521 DR K L ACHAL VANSHI COLONY JAISALMER 345001 RAJ | JAISALMER | RAJASTHAN | 345001 | L2 | Rejected-Finance quoted high rate |
Tender Value
₹89.1 L
EMD Value
₹1.7 L
Closing Date
11 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JAISALMER
HQ CWE AF JAISALMER
ADDITIONS, ALTERATIONS AND IMPROVEMENTS TO ALTERNATE ATC AT AIR FORCE STATION JAISALMER
2024_MES_663592_2
80299/E8
Open Tender
Civil Works
Item Rate
300 days
GE (AF) JAISALMER
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (AF) JAISALMER
₹1.7 L
Yes
28 Oct 2024
21 Sept 2024
12 Oct 2024
21 Sept 2024
11 Oct 2024
28 Sept 2024
Amount
Surface excavation in soft/disintegrated rock not exceeding 30cm and averaging 15cm deep and getting out complete complete all as specified and directed.
Earth work in excavation in ordinary rock by mechanical means (Hydraulic Excavator/JCB) over areas (exceeding 30 cm in depth, 1.5m in width as well as 10Sqm on plan) (upto 1.5m depth) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as complete all as specified and as directed.
Earth work in excavation in ordinary rock by mechanical means (Hydraulic Excavator/JCB) over areas (exceeding 30 cm in depth, 1.5m in width as well as 10Sqm on plan) (depth 1.5m to 3.0m) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, complete all as specified and as directed.
Earth work in excavation in ordinary rock by mechanical means (Hydraulic Excavator/JCB), in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m, as in ordinary rock complete complete all as specified and directed.
Excavating in trenches in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying pipe lines and elecrtric cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Excavating in trenches in hard/dense soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying pipe lines and elecrtric cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Excavating in trenches in soft/disintegrated rock, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying pipe lines and elecrtric cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Excavating in trenches in soft/disintegrated rock, exceeding 1.5m wide and not exceeding 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying pipe lines and elecrtric cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Excavating in trenches in soft/disintegrated rock, exceeding 3m wide and not exceeding 4.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying pipe lines and elecrtric cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30cm thick, watering, ramming/rolling and finishing to required size, shape, etc., not exceeding 1.5m high from base including supply of approved earth obtained from Air Force campus or from within Air Force station if approved including excavation and carrying to work site and including surface dressing not exceeding 15cm deep and cleaning away all grass, vegetation, saplings, shrubs, bush wood under growth roots, soft/loose soil etc and removing the same etc complete all as specified and as directed.
M&L for 20mm thick sand cushion with clean river sand duly clear of residual , organic and deleterious materials spread evenly to uniform thickness laid over DLC layer as specified and directed. (No additionaI amount to be paid for overlap) complete all as specified and directed.
Returning filling in , including, spreading, levelling, watering and well ramming, in soft /loose soil, in layers not exc 25cm complete all as specified and directed.
Returning filling in , including, spreading, levelling, watering and well ramming, in hard/dense soil, in layers not exc 25cm complete all as specified and directed.
Returning filling in , including, spreading, levelling, watering and well ramming, in soft / disintegrated rocks, in layers not exc 25cm complete all as specified and directed.
Removing excavated material to a distance not exceeding 50m and depositing where directed, at a level not exceeding 1.5m above above the starting point complete all as specified and directed.
Removing excavated material to a distance exceeding 250m but not exceeding 500m and depositing where directed, at a level not exceeding 1.5m above above the starting point complete all as specified and directed.
M&L for hard core of broken stone or boulders of gauge n. exc 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and rammed to a true surfaces complete complete all as specified and directed.
M&L for Pre-Constuction Antitermite treatment (ATT) by treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for Pre-Constuction Antitermite treatment (ATT) by treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M&L for Pre-Constuction Antitermite treatment (ATT) by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L for Pre-Constuction Antitermite treatment (ATT) by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete complete all as specified and directed.
M&L for Pre-Constuction Antitermite treatment (ATT) by treating the soil along with external perimeter of building at the rate of 2.25 litres of emulsion per metre of the perimeter wall complete complete all as specified and directed.
S&F Formwork to sides of rough finished flat surfaces of concrete as in foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
S&F Formwork to square, rectangular and polygonal fair finished sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
S&F Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, for fair finished surface etc. also splays between floors and beams, etc. complete complete all as specified and directed.
S&F Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work flat and fair finished surface; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
S&F Formwork to fair finished surfaces of concrete as in chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
S&F Formwork to rough finished surfaces of concrete circular on plan as in well curbs complete all as specified and directed.
S&F Formwork to rough finished flat surfaces of concrete as in edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
M&L for Reinforced Cement Concrete (RCC) M-25 Design Mix using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for Reinforced Cement Concrete (RCC) M-25 Design Mix using 20 mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for Reinforced Cement Concrete (RCC) M-25 Design Mix using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Reinforced Cement Concrete (RCC) M-25 Design Mix using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed.
M&L for Reinforced Cement Concrete (RCC) M-25 Design Mix using 20 mm graded stone aggregate as in chajjas complete all as specified and directed.
M&L for Plain Cement Contrate (1:4:8) type D2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M&L for Plain Cement Contrate (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for 75mm thick Plain Cement Concrete (1:3:6) type C-2 using 40mm graded stone aggregate, as in plinth protection, paths , steps etc., surfaces finished even and fair without using extra cement complete all as specified and directed.
M&L for 75mm thick Plain Cement Contrate (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for Plain Cement Concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in cills, steps and blocks for inserting hold fast of doors and windows complete all as specified and directed.
M&L for 40mm thick Plain Cement Contrate (1:2:4) type B-0 using 12.5mm graded stone aggregate as in Damp Proof Course (DPC) to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
M&L for Precast Cement Concrete Masonry Work of solid building block over 10cm in width with and including pre-cast cement concrete solid building blocks or slabs in PCC (1:3:6) type C-1 using 20mm graded stone aggregate and setting in cement mortar (1:6) complete complete all as specified and directed. (Note:- Unit rate qouted by the contractor shall be deemed to be inclusive of forming or cutting or leaving chases for concealed water tubing and concealed conduit wiring)
M&L for Precast Cement Concrete Masonry Work of solid building blocks with and including pre-cast cement concrete solid building blocks or slabs in PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 10cm thick (with plain or interlocking joints as directed), setting in cement mortar (1:4) , complete, as in walls complete all as specified and directed. (Note:- Unit rate qouted by the contractor shall be deemed to be inclusive of forming or cutting or leaving chases for concealed water tubing and concealed conduit wiring)
M&L for Walling of squared rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete complete all as specified and directed.
M&L for square rubble walling Jodhpur type built in cement mortar (1:6) brought up to courses well bonded, bedded and solidly hearted as in manhole complete all as specified and directed.
Extra over item 44 above for hammer dressing to face stones with maximum depressions on face from a stright edge not exceeding 20mm and dressing face beds and joints as specified to squared rubble walling Jodhpur type brought upto courses complete all as specified and directed.
M&L for Brick Work built in cement mortar (1:4) with sub-class 'B' old size bricks straight or curved on plan exceeding 6m mean radius complete all as specified and directed.
M&L for Brick Work built in cement mortar (1:4) in one brick thick honey comb walling with sub-class 'B' old size bricks straight or curved on plan exceeding 6m mean radius complete all as specified and directed.
M&L for Brick Work built in cement mortar (1:4) in one and half brick thick honey comb walling with sub-class 'B' old size bricks straight or curved on plan exceeding 6m mean radius complete all as specified and directed.
M&L for 40mm thick Plain Cement Contrate (1:2:4) type B-1 using 20mm graded stone aggregate as in sub base, wearing course, sub-floors and pavings etc. complete all as specified and directed.
M&L for 50mm thick Plain Cement Contrate (1:2:4) type B-0 using 12.5mm graded stone aggregate as in flooring wearing course, sub-floors and pavings etc. complete all as specified and directed.
M&L for 30mm thick Wearproof granolithic metallic hardner concrete as as in floor topping, wearing course, and pavings etc. as specified in manufacturer instructions (included metallic hardner) complete all as specified and directed. Note:- Unit rate qouted by the contractor shall be deemed to be inclusive of metallic hardner)
M&L for Plain Cement Concrete (1:3:6) type C-1 using 20mm graded stone aggregates as in copings including weathering, slightly rounded or chamfered angles and throating and necessary form work and finishing the top surface of concrete even and smooth without using extra cement complete all as specified and directed.
M&L for pre-cast reinforced cement concrete (1:2:4) type B-1, using 20 mm graded crushed stone aggregate as in manhole slabs, and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work etc complete all as specified and directed. (Note : Reinforcement shall be measured and paid for separately )
M&L for cast in situ plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as cast in situ in plinth courses, parapets, copings, bed plates, surface channels, drains and the like including weathering, slightly rounded or chamfered angles & throating and use of form work complete all as specified and directed.
M&L for Plain Cement Concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in Roof Padding,or similar work complete all as specified and directed.
S&F 10mm dia and over mild steel TMT bars as in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F 6 to 8mm dia and over mild steel TMT bars as in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F 6 to 8mm dia and over mild steel TMT bars as in stirrups, rings, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F Framed Work of rolled mild steel structural work using Fe-410 W (Gde E-250 Quality 'B') as in doors or gates of angle or other section with gusset plates,rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F Structural Steel Work in Tubular Pipes stanchions, purlins, rafters, trusses including special shaped washer etc. complete using or including butt welded tubes conforming to I.S. 1161-1979 grade St - 240 complete all as specified and directed.
S&F mild steel miscellaneous works asn in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F 1.0mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete complete all as specified and directed.
S&F 0.63 mm thick Pre-painted Galvanised, corrugated mild steel sheeting with grade of zinc coating 275 as in roofs,walls etc.,with two corrugations side lap, fixed with L- type or J- tytpe or cranked hook bolts and washers complete all as specified and directed.
M&L for rendering 5mm thick cement plaster in cement plaster (1:3) on concrete surfaces of ceiling, soffits of chajjas/drop & roof projection facia etc. surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick cement plaster in cement plaster (1:6) on stone/brick/concrete block masonry surfaces of any description surfaces finished even and smooth without using extra lime or cement complete all as specified and directed.
M&L for rendering 10mm thick cement plaster in cement mortar (1:6) on stone/brick/concrete block masonry surfaces of any description surfaces mixed with water proofing compound finished even and smooth without using extra cement complete all as specified and directed. Note : WPC will be measured and paid seperately.
M&L for rendering 10mm thick cement plaster in cement plaster (1:4) on stone / concrete block masonry surfaces other than fair faces of concrete / brick surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick cement plaster in cement plaster (1:4) mixed with 3% water proofing compound, over green concrete surface (WPC will be measured and paid seperately) surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick cement plaster in cement mortar (1:3) on stone / concrete block masonry surfaces fair faces of concrete / brick finished even and smooth without using extra lime or cement complete all as specified and directed.
M&L for rendering 15mm thick cement plaster in cement mortar (1:3) on stone / concrete block masonry surfaces fair faces of concrete / brick finished even and smooth without using extra lime or cement complete all as specified and directed.
M&L for rendering 15mm thick cement plaster in cement mortar (1:4) on stone / concrete block masonry surfaces other than fair faces of concrete / brick finished even and smooth without using extra lime or cement complete all as specified and directed.
M&L for rendering 15mm thick cement plaster in cement mortar (1:6) on stone / concrete block masonry surfaces other than fair faces of concrete / brick or on the one side od lathing; finished even and smooth without using extra lime or cement complete all as specified and directed.
M&L for applying 3mm thick wall care putty on new or old surface of ceiling complete all as specified and directed.
Preparing new steel surfaces of any description, over 10cm in width or girth, not other wise described and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for prepration of new plastered surface of ceilings, soffits of chajjas/drops/fins and roof projection facia; and distempering with two coats of oil emulsion distemper over a coat of alkali resistant priming paint complete all as specified and directed.
M&L for preparation of newly plastered surfaces walls and and distempering with two coats of oil emulsion distemper over a coat of alkali resistant priming paint complete all as specified and directed.
M&L for preparation of new surfaces on walls/roofs and applying two coats of Exterior Emulsion Paint (Weather Coat) 1st quality as in different tint / camouflage pattern as directed at any height of the building/structure complete all as specified and directed.
M&L for preparation of old plastered of wall surfaces and distempering with two coats of oil emulsion distemper over a coat of alkali resistant priming paints oomplete all as specified and directed.
M&L for preparation of old treated/ decorated external wall/roof surfaces of any storeys / height upto 10m of any description and applying one coat of exterior emulsion paint (weather coat) 1st quality in different tints/ camouflaging pattern as approved complete all as specified and directed.
M&L for prepration of old surface plastered and applying two coats of White washing on ceiling, soffits of chajjas/drop & roof projection facia etc complete all as specified and directed.
Supply only integral water proofing compound ISI marked complete complete all as specified and directed.
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces over bituminious primer complete all as specified and directed.
M&L for 3mm thick APP based polymeric membrane minimum weighing 3kg/sqm and minimum reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified and directed.
S&F Anodised Aluminium Snap Grid frame work of size 605mmx605mm for false ceiling complete all as specified and directed.
S&F Hangers 6mm dia GI rod (upto 1200mm length) adjusting level fixed to roof by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed.
S&F 12mm thick Perforated Particle board/ tiles of size 60cmx60cm for insulation and accoustic purposes, fixed with nails to timber frame work or with staples on snap grid in ceiling, flat or sloping complete all as specified and directed.
Dismantling floor, hearth or wall tilling/granite including cement mortar bedding (but not backing) and removing debris to outside MD land complete all as specified and directed.
M&L for 7-8mm thick Non Skid Coloured Ceramic Tiles (square or rectingular) area of each tile exceeding 0.06Sqm but not exceeding 0.11Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar (1:6) etc complete all as specified and directed.
M&L for 7-8mm thick Non Skid Coloured Ceramic Tiles (square or rectingular) area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar (1:6) etc complete all as specified and directed.
M&L for 10mm thick light shade Vitrified Tiles (square/ rectangular) polished, area of each tiles not exceeding 0.36Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar (1:6) etc complete all as specified and directed.
M&L for 10mm thick Coloured Johnson Endura Tiles, square of size 300mmX300mm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar (1:6) etc complete all as specified and directed.
M&L for 7mm thick Glazed Coloured Ceramic Tiles of size 300mmX450mm as in vertical surfaces such as dados, skirtings, risers etc., set and jointed in neat cement slurry and pointed in white or colour cement to match over and 10mm thick rendering cement plaster in cement mortar (1:4) on other then fair faces of brick work etc complete all as specified and directed.
M&L for 20-25mm thick Machine Cut Kota Stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slaband including 15mm thick screed bed in cement mortar (1:6) including rubbing and polishing complete all as specified and directed.
M&L for 20mm thick Granite ( of any type) slabs/Tiles laid in floors/treads over 15mm thick screed bed incement mortar (1:6), set and jointed in neat cement slurry and pointed in white cement with admixture of pigment to match the shade of granite complete all as specified and directed.
M&L for 80mm thick Rubber Moulded precast conctete interlocking paver block M-40 Grade, any shape and size with gray cement no pigment confirming to IS -15658-2006, complete all as specified and directed.
S&F Acoustic wall paneling with 8-10 mm thick acoustic panel over 18-20mm thick wood wool/ plywood slat over 50mm thick glass wool/ synthetic wool 32 density over GI support framework as per manufacture instructions complete all as specifified and as directed. (Note : Make of acoustic material shall be any of Armstong/ Techno Acoustic/ Saint Gobin)
S&F Second Class hard-wood timber, clean sawn, framed and fixed with srew in scantlings, as in desk frame for fixing block boards complete complete all as specified and directed.
S&F 18/19 mm thick Block boards, grade 1 quality, anti termite, water proof , exterior grade, decorative type with decorative face veneer on both face, fixed with screws to timber frame-work complete complete all as specified and directed.
S&F 30mm thick flush shutters factory made solid core construction with block boards core and plywood face panels, commercial type on both sides (ISI marked) and covered with 2-3mm decorative face veneer (both faces of door) with lipping/farame to match fixed to chowkhats complete all as specified and directed.
S&F 30mm thick flush shutters factory made solid core construction with block boards core and plywood face panels, commercial type on both sides (ISI marked) fixed to chowkhats complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet rainforced with MS square tube 19mmx19mm x19gauge & PDM rubber gasket wealther seal to be provided through out the frame. The profile shall be mitre cut at two corners and jointed by inserting 02 Nos of 150mm long brackets of 15mmx15mmx15gauge MS square tube inside the 19mmx15mm MS square tube and suitably screwed complete all as specified and directed.
S&F 30mm thick (style) factory made solid PVC door shutter consisting of frame made out of MS tubes 19mmx19mmx19gauge for stiles & 15mmx15mmx19 gauge for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail , lock rail and bottom rail on either side & as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading & joined together with solvent cement etc complete all as specified and directed.
S&F 5mm thick solid PVC wall panelling/ Lining consisting of 5mm thick prelam PVC sheet inclusive of solvent cement & fixing at site on PVC frame including dismantling of old unserviceable wall panelling etc complete all as per specifications and as directed. Note:- Rate shall be inclusive of refixing of dismantled E/M fittings and fixtures.
S&F 5mm thick PVC sheet fillet of width 35mm with U shape groove of 2mm depth at centre for wall panelling inclusive of fixing on to wall with screws to make PVC frame as per specification and drawing complete all as specified and directed.
S&F 1mm thick PVC sheet wood grain printed fixed or laid on face of flush doors by using rubber based adhesive, at site complete all as specified and directed.
S&F Anodized Aluminium Frame for door, windows, ventilators with one or more rebates including joining cleat for fixing etc complete complete all as specified and directed.
S&F Anodised Aluminium sections for Door Shulters (aluminium sections weighing 0.55 Kg/m) including necessary joining cleats, glazing clips, rubber neoprane packing, extruded anodised aluminium handle-2 Nos in each door shutter, one tower bolt and 04 Nos hinges in each shutter complete all as specified and directed.
S&F 10mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed. Note: (i) The glass shall be fixed as in double layered tinted toughened glass to withstand sustained wind speed of 125 kmph or more. Make shall be SAFEX or equivalent make. (ii) The glasses should be free of distortion, waterproof and with vapour - proof seal. Each window unit of tower shall consist of two panes of glass separated by a 13mm air space. Each of two panes shall be 10mm thick with 13mm air space and if there is any vapour or moisture present at the time of installation of glasses shall be dehydrated by a drying agent as per manufacturer's instructions.
S&F 6.3 mm Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane including grinding, polishing and rounding off edges of glass complete complete all as specified and directed.
S&F 5.5 mm thick sheet glass ordinary quality and glazing with clips in square exc 0.5 Sqm in each pane complete complete all as specified and directed.
S&F 4mm thick sheet glass ordinary quality and glazing with clips in square n exc 0.5 Sqm in each pane complete complete all as specified and directed.
S&F Anodised Aluminium Sliding Door Shutters and Frame, aluminium section weighing 0.55 Kg/m including necessary standred roller, channel joining cleats , glazing clips , rubber neoprene packing , handles-2 Nos, tower bolt 200mm-02 Nos, Aluminium Sliding bolt 300mm long in each door, anodised aluminium snap beading screws etc. complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed.
S&F 200m size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F 150mm size aluminum anodized barrel tower bolt of extruded section complete all as specified and directed.
S&F100mm long stainless steel Butt hinges complete all as specified and directed.
S&F 125mm size aluminum handle cast type, anodized complete complete all as specified and directed.
S&F peg set 6 (Zinc) Prayag or equivalent complete all as specified and directed.
S&F 300mm long Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 250mm long Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F aluminium (extruded section body) door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701mm to 850mm in width and of weight between 36 to 60Kg and fixed complete all as specified and directed.
S&F 100mm size 4 lever Brass Mortice Lock, vertical type1complete all as specified and directed.
S&F Rolling shutter with laths of thickness 1.25 mm push pull or manual type including top cover, anchoring rod, hasp and staple and one shop coat of primer and erecting in position as indicated complete complete all as specified and directed.
S&F Steel Ball Bearings of suitable size for smooth functioning of rolling shutter complete all as specified and directed.
S&F Safety Lever Locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
S&F 40mm bore mild steel pipes heavy grade for rolling shutter for smooth functioning of old rolling shutter complete all as specified and directed.
S&F Steel Spring of suitable size for rolling shutter for smooth functioning of old rolling shutter complete all as specified and directed.
S&F Flat Iron Side Clamps of rolling shutter to any type of wall , pillar etc. with and including flat iron,necessary welding work with stainless steel fasteners complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any lenghts with rubber ring joints, laid in trenches or in floors etc complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any lenghts with rubber ring joints,fixed to walls etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any lenghts with rubber ring joints, laid in trenches or in floors etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any lenghts with rubber ring joints, fixed to walls etc complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends any radius etc complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends any radius provided with access door etc complete all as specified and directed.
S&F110mm bore PVC (SWR) bends any radius etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single(Single T) equal or unequal provided with access door etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) slotted vent cowl etc complete all as specified and directed.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), double layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete all as specified and directed.
S&F 20 mm dia ball valve, high pressure of PTMT with epoxy coated, aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minium wt-210 gms) complete all as specified and directed.
S&F 15mm bore galvanised steel water tubing ISI marked medium grade with necessary fittings unions, tees, elbows, bends, nipples, sockets, reducers and fixtures etc including necessary cutting, threading, laid in trenches/floors, fixed to walls and ceilings etc complete all as specified and directed.
S&F 20mm bore galvanised steel water tubing ISI marked medium grade with necessary fittings unions, tees, elbows, bends, nipples, sockets, reducers and fixtures etc including necessary cutting, threading, laid in trenches/floors, fixed to walls and ceilings etc complete all as specified and directed.
S&F 25mm bore galvanised steel water tubing ISI marked medium grade with necessary fittings unions, tees, elbows, bends, nipples, sockets, reducers and fixtures etc including necessary cutting, threading, laid in trenches/floors, fixed to walls and ceilings etc complete all as specified and directed.
S&F 25mm bore gun metal, globe or gate valve with Iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S&F 15mm bore fancy type premium quality chromium plated stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed all as specified and as direced.
S&F 15 mm bore fancy type chromium plated Bib taps long body, cast copper alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule fancy type complete all as specified and directed.
S&F 75mm diameter of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement & jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) etc complete all as specified and directed.
S&F Wash Hand Basins, vitreous china( flat back) white of size 550mm X 400mm; including cutting for and pinning in ends for 40x40x5mm angle iron brackets painted or erecting stand including waste fittings; 32 mm bore PVC flush pipe; 15mm bore chroimium plated pillar tap fancy type copper alloy wiith capsten heads, screwed down high pressure with long screwed shanks and fly nuts; 15mm size PVC conection 450mm long with brass nuts, PTMT waste coupling for 32mm bore dia of discharge pipe etc complete all as specified and directed.
S&F Wash down water closet (Pedestal pattern) Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories, including connection to drain (or out going pipe )and to flushing pipe ,anti-sypohonage pipe etc. with plastic water closed seat cover (white)closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device hinge device including all necessary accessories like rag bolts/ gel gasket, jet spray etc complete all specified and directed.
S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe); including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) with and including 40mm size brass chromium plated waste coupling with long screwed shanks and fly nuts flange end bedded in red lead complete all as specified and directed.
S&F Urinal spreader of Brass chromuium plarted for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed.
S&F 32mm bore of pipe low density polythylene pipes (LDPE) with fittings as required of pressure rating 6 kgf/cm2 and fixed complete to walls, ceilings or in floors etccomplete all as specified and directed.
S&F 40mm bore of pipe low density polythylene pipes (LDPE) with fittings as required of pressure rating 6 kgf/cm2 and fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
S&F 10 litres capacity PVC valveless, suphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including bracket and connect to pipes with and including 15mm size PVC conection 450mm long with brass nuts/adapters complete complete all as specified and directed.
S&F 15mm size PVC connections with PTMT nuts of length 600mm complete all as specified and directed.
S&F corner glass shelf assembly 300mm size of Make: Prayag or equivalient complete all as specified and directed.
S&F liquid soap container of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 105gms) etc complete all as specified and directed.
S&F Soap dish, Vitreous china white aprroximately size 160mmx160mmx90mm, fixed to plugs with chromium plated brass screws prayag or equivalent complete all as specified and directed.
S&F Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F 20mm dia 'D' type tubular tower rail 60cm long chromium plated brass between flanges complete all as specified and directed.
S&F Harrison rails of anodised aluminium alloy with fixing brackets, stops,rollers etc complete all as specified and directed.
S&F 18-20mm thick polyethylene crumple/ expansion joint filler board (60kg/cum) complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150mm bore complete all as specified and directed.
S&F 150mm bore salt glazed stone ware (SGSW) drain pipes, grade `A', ISI marked, laid to slope in trenches, jointed in cement mortar (1:1) and tested complete all as specified.
Taking down cement plaster of any description, on brick or stone walls/ceiling etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
Taking down chowkhats or frames with shutters (without taking off shutters from the frames exceeding 1.5Sqm but not exceeding 4 sqm) each complete all as specified and directed.
Taking down existing unserviceable rolling shutter complete of any size and any type and removing from site complete all as specified and directed.
Dismantling of existing water proofing roof treatment any type, and in any location up to existing RCC Slab by Chiesling, drilling, scraping and any description and in any position and thrown away complete all as specified and directed.
Dismantling of wall and ceiling board (fiber pulp, insulation etc) or insulation board/slabs /blankets any thickness including all frame work complete all as specified and directed.
Dismantling wrought iron,or mild steel work, structural steel work etc of any description not otherwise provided for, complete all as specified and directed.
Taking down carefully copper /aluminium point wiring light/fan, socket or power point complete including fittings such as switches, sockets, ceiling rose, bell push bell buzzer lamp holder bracket etc removing from site and making good disturbed surface of wall, floor , ceilings etc to match as per existing surface complete all as specified and as directed.
Taking down submain wiring including earth wire and making good distrubed surfaces to match with the existing surface roof/wall/floor including removing from site complete all as specified and as directed.
Taking down carefully unserviceable main switches, DB including MCB's complete of any size and capacity complete all as specified.
Taking down ceiling fan of size 1200mm sweep from its position without any harm to its blade and painting, greasing, oiling and rewinding of motor and refixing in its position after painting work complete all as specified and directed.
M&L for point wiring for controlled by one switch with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) (Phase and Neutral) in and including non metallic rigid PVC conduit 25mm dia by cutting chases in walls by cutter and making good the surface in cement mortar (1:3) and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with sunk cast iron/pressed steel terminal box of adequate size with 3mm thick plastic laminated sheet cover for one light point/fan point/Bell point controlled by one, one way switch including continuous 1.5 Sqmm copper conductor (multistranded) FRLSH PVC insulated and unsheathed cable connected to earth dolly complete all as specified conforming to IS-694 complete all as specified and directed. Note:- Unit rates qouted by the contractor for elecrical works shall be deemed to be inclusive of cutting chases in wall for PVC counduits and switch boards with electric cutter and making good the surfacewith PCC (1:2:4) type B-0 and cement mortar (1:3) to match as per existing surface
All as per item No. 177 here-in-before but for one 3 pin socket outlet 5 Amps on the same board with other switches.
All as per item No. 177 here-in-before but for one 3 pin socket outlet 5 Amps on independent board.
All as per item No. 177 here-in-before but for one 5 pin socket outlet 15 Amp and 5 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire with terminal box of size 175mm x 100mm x 3.15mm complete all as specified.
S&F switch piano flush button type, 5 Amp, single pole, one way complete all as specified and directed.
S&F switch socket combination 2 in1, 5 Amps multipurpose flush type complete all as specified and directed.
S&F ceiling rose surface bakelite 65mm x 50mm, 2 to 3 terminals with back plate etc complete all as specified and directed.
S&F switch socket combination 2 in 1, 5 and 15 Amps multipurpose flush type complete all as specified and directed.
S&F Electronic fan regulator flush mounting 300-400 Watts switch size having 4 step to regulate/ control speed of ceiling fan complete.
S&F submain wiring with two run of single core (FRLSH) PVC insulated and unsheathed cable with copper conductor (multistranded) having nominal area 6.0 Sqmm drawn through and including one run of PVC conduit of suitable size concealed type and making electric connections including one run (FRLSH) PVC insulated single core copper conductor cable 6.0 qmm as a earth continuity conductor drawn through PVC conduit, including cutting chases in brick wall wherever necessary, replastering and making good to match the existing specifications complete all as specified and directed. Note :- (i) Rates are deemed to be included chases of conduit and making holes in wall/floor for passing in or through conduit (ii) Two run of 6.0 Sqmm single core (FRLSH) PVC insulated copper conductor cable, one run of 6.0 Sqmm copper conductor cable (FRLSH) as a earth lead including one run of PVC conduit will be measured as a one unit.
S&F submain wiring (for AC) with two run of single core (FRLSH) PVC insulated and unsheathed cable with copper conductor (multistranded) having nominal area 4 Sqmm drawn through and including one run of PVC conduit of suitable size concealed type and making electric connections including one run (FRLSH) PVC insulated single core copper conductor cable 4 Sqmm as a earth continuity conductor drawn through PVC conduit, including cutting chases in brick wall wherever necessary, replastering and making good to match the existing specifications complete all as specified and directed. Note :- (i) Rates are deemed to be included chases of conduit and making holes in wall/floor for passing in or through conduit. (ii) Two run of 4 Sqmm single core (FRLSH) PVC insulated copper conductor cable one run of 4 Sqmm copper conductor cable (FRLSH) as a earth lead including one run of PVC conduit will be measured as a one unit.
S&F Sheet Metal Enclosures for DB SPN 8 ways, double door, 240V with 200A rated copper bus bar complete all as specified and directed.
S&F Sheet Metal Enclosures for DB TPN 4 ways, vertical type having suitable size copper bus bar and with and including incomming MCCB, 4 pole, 125 Amp, 415V, 16 KA breaking capacity complete all as specified and directed. Note : Single pole MCBs are measured and paid seperately.
S&F MCB SPN 40-63 Amp, 240 Volts, 10 KA breaking capacity 'C' curve type complete all as specified and directed.
S&F MCB SP 6-32 Amp, 240 Volts, 10 KA breaking capacity 'C' curve type complete all as specified and directed.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F LED desk light of minimum 10 watt with flexible neck as per sample with multi function to regulate the light as per the requirement of the controller complete all as specified and directed.
S&F ceiling lights 36W suitable to operate on dimmer to regulate the lights as per the requirement of the controller complete all as specified and directed. Note: Cost of dimmer/control panel required to control the lights shall deemed to be included in the quoted rate. No extra payment shall be made on this account.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15cm thick packed layers of charcoal dust and common salt and connected to earth lead GI 4mm dia by means of bolts, nuts check nuts and washers of galvanized iron or steel and thimbles and other end of the 4mm dia GI earth wire connected to DB and protected by 15mm bore GI pipe medium grade and watering pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:2:4 type B-1 and RCC cover and all as shown in Electrical Plate No. 3 of MES Schedule of Rate (SSR) Part-1 of 2009. Unit rates qouted by the contractor shall (a) Excavation and earth work or drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete (1:2:4) type B-1, 80mm thick Pre-cast RCC cover with suitable handle in RCC (1:2:4) type B-1,reinforced with XPM weighting not less than 4 Kg/Sqmm in lieu of CI cover. (c) Funnel with 20mm bore GI pipe light grade as watering pipe and 15mm bore GI pipe medium grade protection pipe lugs etc complete all as specified and directed. (d) The unit rate shall deemed to include for Test point, extra length of main earthing lead 4mm dia GI earth wire from top of the earth plate up to and above ground level and upto 7.5m beyond top of ground level or as required at site. e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. On testing after completion if the desired earth resistance is not obtained the earthing will be redone without any extra cost to Govt.
M&L for earthing complete with Copper earth plate electrode 600x600x3.15mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15cm thick packed layers of charcoal dust and common salt and connected to earth lead 20x3mm copper earth strip by means of bolts, nuts check nuts and washers of galvanized iron or steel and thimbles and other end of the 20x3mm copper earth strip connected to DB and protected by 40mm bore GI pipe light grade and watering pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:2:4 type B-1 and RCC cover and all as shown in Electrical Plate No. 3 of MES Schedule of Rate (SSR) Part-1 of 2009. Unit rates qouted by the contractor shall (a) Excavation and earth work or drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete (1:2:4) type B-1, 80mm thick Pre-cast RCC cover with suitable handle in RCC (1:2:4) type B-1,reinforced with XPM weighting not less than 4 Kg/Sqmm in lieu of CI cover. (c) Funnel with 20mm bore GI pipe light grade as watering pipe and 15mm bore GI pipe medium grade protection pipe lugs etc complete all as specified and directed. (d) The unit rate shall deemed to include for Test point, extra length of main earthing lead 20x3.15mm copper earth strip from top of the earth plate up to and above ground level and upto 7.5m beyond top of ground level or as required at site. e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. On testing after completion if the desired earth resistance is not obtained the earthing will be redone without any extra cost to Govt.
S&F Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed.
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
S&F 20x3mm size copper strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe pr fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.
S&F 32x6mm size copper strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe pr fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1, using 20 mm graded crushed stone aggregate as in coping of poles, making base for fixing earth strips, air temination rod on roof top, blastpen, path to LT Panels boards, Bollard lights base, surface channel of manholes/ drains, cills, hold fasts, and the like in any position, benching for manholes, water stand post, plateform, path and the like; including weathering, slightly rounded or chamfered angles and throating including necessary form work as complete all as specified and directed.
Supply, install and testing cassette type air conditioner units indoor and outdoor complete with cordless remote control unit, twin rotary compressor, single phase units 220V - 240V, 50 Hz of capacity 2.0 TR complete all as specified and directed. Note: (i) Cost of company recommended suction and discharge copper pipe from indoor unit to outdoor unit shall deemed to be included in the quoted rate. No extra payment shall be made on this account. (ii) Suitable size of copper wire as recommended by the OEM from indoor unit to outdoor unit shall deemed to be included in the quoted rate. (iii) Cost of insulation of suction and discharge pipe and drain pipe from indoor unit to outdoor unit shall deemed to be included in the quoted rate. (iv) Addition/alteration to false ceiling for mounting of indoor unit and fixing accessories shall deemed to be included in the quoted rate. (v) Cost of stand/platform for outdoor unit shall deemed to be included in the quoted rate.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 110 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
S&F metal clad earth plug and socket with and including one MCB 20 Amp in sheet metal enclosure complete all as specified and directed.
Supply, lay, joint fix and test cable in repair of LT XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core including including fixing on walls and poles, passing though ducts and taking down of old u/s cable from trenches complete all as specified and directed.
Supply, lay, joint fix and test cable in repair of LT XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core including including fixing on walls and poles, passing though ducts and taking down of old u/s cable from trenches complete all as specified and directed.
M&L for sand cushioning with local tibba sand for under ground cable provided with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed. Note:- 18cm punned thickness shall be considered for measurement and payment.
M&L for 40 to 50mm thick stone patti rough dressed jodhpur stone slab cover laid in trenches for protection of cable 25 to 30 cm wide and not less then 50cm in length laid dry abutting each other with gap between adjecent slab not excedding 10 mm over sand cushoing complete all as specified and directed.
Supply, lay and fix 50mm bore galvanised steel tubing, light grade ISI mark with all fittings laid in trenches, fixing in wall and pole including suitable GI clamps for bracing the pipe with pole for cable protection complete all as specified and as directed.
Disconnect, dismantle old unserviceable LT panel/ Feeder pillar box and design, supply, erection, commission and test LT Panel, factory made outdoor type, dust, weather, vermin proof, platform mounted, suitable for 3 phase 4 wire, 415 Volts AC supply and having 4 Nos Strip type bus bars of 400 Amps, looping & branch connection system shall be made with suitable rating aluminium bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and structural rooled mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The feeder pillar/LT panel shall be provided with 4 Nos of legs of length not less than 0.9m long, 30cm shall be below ground level embeded in PCC 1:3:6 below ground level and 30 cm above ground level in such a way to errect the LT panel firmly complete as directed at site. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the following:-
CONTROL WIRING : All control wirings shall have to be carried out with 1100 Volts rated FRLSH grade PVC insulated multi-flexible type copper wire of cross sectional area 1.5 Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.
CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables.
INCOMING :- MCCB 250 Amps, 4 pole, 415 Volts, 25 kA, 50 Hz, thermal magnetic release, adjustable 70% to 100 % - 01 Nos OUTGOING :- (a) MCCB 63 Amps, 4 pole, 415 Volts, 16 KA, 50 Hz, thermal magnetic release, adjustable 70% to 100% - 01 Nos (b) MCCB 100 Amps, 4 pole, 415 Volts, 16 KA, 50 Hz, thermal magnetic release, adjustable 70% to 100% -01 Nos (c) MCCB 160 Amps, 4 pole, 415 Volts, 25 KA, 50 Hz, thermal magnetic release, adjustable from 70% to 100 %-01 Nos (d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 Volts, accuracy class 1 - 01 Nos (e) Digital Ammeter 96mm x 96mm suitable to read 0 to 400 Amps, accuracy class 1% - 01 Nos (f) Current transformer (CT) of rating 250/5, tape wound, rated burden 5 VA - 03 Nos (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (j) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (k) Danger Notice Plate -02 Nos (l) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 1.50 Sqm front area) Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to GE through Engineer-in-Charge before procurement of LT panel for approval alongwith CPRI approval. Foundation will be prepared as per instructions of manufacturer and rate of fondation deemed to be included in the quoted rates qouted by the contracor.
MARUDHARA CONSTRUCTION COMPANY (BID ID -3135121)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .