Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC 57 7 MEGHNAD SAHA SARANI PRADHAN NAGAR SILIGURI 734 403 DIST DARJEELING | SILIGURI | DARJEELING | WEST BENGAL | 734403 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹43.2 L+₹6.4 L (17.5%)Rejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹44.9 L+₹8.1 L (22.1%)Rejected-Finance C O BIKASH CHAKRABORTY OPPOSITE GITAM NURSERY SCHOOL NEAR BAGHAJATIN PARK PO SILIGURI DISTT DARJEELING WEST BENGAL 734401 | DARJEELING | WEST BENGAL | 734401 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹44.9 L+₹8.2 L (22.3%)Rejected-Finance GEETANJALI COMPLEX B BLOCK 2ND FLOOR MUKUNDA DAS ROAD MILANPALLY SILIGURI 734405 DARJEELING | SILIGURI | DARJEELING | WB | 734405 | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹45.1 L+₹8.4 L (22.8%)Rejected-Finance AMRITBASTI GARIGHURA PO SHIMULBARI PS KURSEONG DIST DARJEELING WB PIN CODE 734409 | 734409 | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Jun 2023, 6:00 pmClosed
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
REPAIRS TO FENCING,DRAIN , CULVERT, BLDG SECURITY LIGHT,STREET LIGHT AND ALLIED WORKS IN SSV,OLD DSTV,MPV UNDER GE SUKNA IN SUKNA MIL STN
2023_MES_600597_1
GE Sukna/8549
Open Tender
Civil Works
Works
270 days
Sukna
AS PER TENDER DOCS
8 documents required · 8 mandatory
₹500
GE Sukna
₹90,000
Yes
28 Jun 2023
2 Jun 2023
24 Jun 2023
2 Jun 2023
23 Jun 2023
17 Jun 2023
3 Jun 2023 - 23 Jun 2023
Amount
B/R PORTION
M&L PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in surface channel and drain including demolition complete all as specified and as directed.
Use and Waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed.
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping of drain including necceesry form work & demolition complete all as specified and as directed.
Demolition of brickwork built in cement mortar complete all as specified and as directed.
M&L Brick work with subclass 'B' Brick , straight or curved on plan exc 6m mean radius built in CM 1:6 as in drain complete all as specified and as directed.
M&L for providing precast reinforement cement concrete 1:2:4 type B1 (using 20 mm graded aggregate) and set in CM 1:4 as in cover slab for drain & similar articles including demolition of existing reinforced concrete complete all as specified and as directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for flush pointing to brick wall in cement mortar 1:3 complete all as specified and as directed.
S & F RCC hume pipe 300 mm bore class NP-2 laid & jointed including collar and dismantling of cast iron /reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed
M&L for PCC 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 300 mm bore pipe complete all as specified and directed.
Excavation of earth work in trenchs not exceding 1.5 m wide & depth for foundation etc or for shaft,wells, etc and n. exc 10 Sqm on plan and n.exc M in depth & getting out in soft/loose Soil complete all as specified and as directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
M&L Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed by Engr in charge
Dismantling of post or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground post embedded in natural grounds all as directed by Engr-in-Charge.
M&L for plain cement concrete 1:3:6 type C-2 in foundations, filling and mass concrete and demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
S&F mild steel flat iron/angle iron for post and strut in fencing including cutting top to shape as direced drilling hols notching for wire etc including all necessary reveting etc complete all as specified and as directed.
S&F mild steel screw bolt (machne made with hexogonal or square heads at one end and screwed the other or screwed both ends each screwed end to be filled with washer one nut 11 to 15 mm dia shank and exc 10 cm and n.exc 15 cm complete all as specified and as directed.
Supply only chain link fencing for fixing to fencing post with nut and bolt and flat iron complete all as specified and as directed.
Fixing only in repairs chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
S&F galvaniseed. 2 strand , steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and stranding and fixing to any type of slandered rails straining bolts, including, securing or tying at crossing with clips and dismantling the barbed wire complete as specified and directed.
S&F 10 mm round bars as in securing of chain link fencing complete all as specified and as directed.
M&L preparing new steel surfaces of any description, not otherwise describe over 10cm width or girth and applying two coats of synthetic enamel paint over red oxide complete all as specified and as directed.
E/M PORTION
BLANK
Supply,laying testing and commissoning of LT cable in repair XLPE insulated with FRLS loading factor on inner and outer sheath of Extruded PVC and wire armoured electric power cables (hevy duty) with aluminium conductor 1100 volts grade of size 10 sqmm 4 core complete all as specified and directed. Make Havells/ Gloster/Finolex/PolyCab
Supply,laying testing and commissoning of LT cable in repair XLPE insulated with FRLS loading factor on inner and outer sheath of Extruded PVC and wire armoured electric power cables (hevy duty) with aluminium conductor 1100 volts grade of size 16 sqmm 4 core complete all as specified and directed. Make Havells/ Gloster/Finolex/PolyCab
Supply,laying testing and commissoning of LT cable in repair XLPE insulated with FRLS loading factor on inner and outer sheath of Extruded PVC and wire armoured electric power cables (hevy duty) with aluminium conductor 1100 volts grade of size 35 sqmm 3.5 core complete all as specified and directed. Make Havells/ Gloster/Finolex/PolyCab
BLANK
BLANK
BLANK
M&L sand coushioning to UG cables (8cm deep before laying of cables and 15 cm over the cable) including spreading, levelling, well ramming in layers complete all as specified and as directed. NOTE:- punned thickness of 18cm only will be considered for payment purpose.
Supply and fix sub class 'B' bricks of standard size for cable protection in trenches complete all as specified and as directed.
Supply and fixing GI tubing light grade 15 mm dia for protection pipe for fixing along the pole with necessary clamps, nut bolt washers including taking down old unsv ones complete all as specified and directed. Make Jindal steel/ Tata or equivalent.
Supply and fixing GI tubing light grade 40 mm dia for protection pipe including taking down old unsv ones complete all as specified and directed. Make Jindal steel/ Tata or equivalent.
M&l for Boring/Drilling (horizontally) manually under 2m deep in soil below existing road suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and as directed.
S&F street light junction box made from CPRI approved factory having size 200 (Width) x 150 (Depth) x 250 (Height) mm (minimum dimensions) made out of 2.00 mm thick CRCA sheet, duly powder coated of approved shade over a coat of red oxide primer both internally and externally, with rain shed all side except back side, comprising of 02 nos copper bus-bar of size 20 x 4 mm mounted on suitable size spacer insulators, necessary cable entry / exit holes for upto 35 sqmm cables, nut-bolts, MS clamps of suitable size for fixing including dismantling complete all as specified & as directed. Make - Havells/L&T/Hager/Crompton
S&F in repairs 6 KW, three phase, automatic street light control panel with and including digital timer switch for automatic switching on / off street light as per set time through programmable 24 hour switch, 32A, TP power contactor, 40A SPN MCB, wall / floor mountable, IP 54 (dust and vermin proof) enclosure made out of CRCA sheet duly powder coated, conforming to IS/IEC 60954-4-1, in-built- short circuit protection, locking arrangement with padlock and panel lock complete all as specified and directed. Make:- Havells / GE / Kakatiya energy system Pvt Ltd
S&F in replacement PVC Insulated Weather proof multicore FRLS PVC sheathed multistranded cables with bright annealed copper conductor of size 1.5 sqmm 3 core for connection of light to pole box completed all as specified and directed. Make Havells/ Gloster/Finolex/PolyCab
S&F in repair LED street light 60 watt made up of pressure die cast aluminium housing environment friendly with high efficiency LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. System Lumen Efficasy ≥120 Lm/W, 10 kV Surge Voltage Protection, Operating Voltage range 140 V - 270 V, Make of LED - Cree/Nichia/Osram/Agilent/Lumileds etc and including fixing arrangement made out of 40 mm bore GI pipe light grade of length not less than 1.2 m, bent to shape, fixed with two pairs of 40 x 5 mm MS flat iron clamps, nuts, bolts & washers to fix the fitting with pole complete all as specified and directed. Note :Contractor have to submit LM 79 and LM 80 report from NABL accredited Lab,Test Certificate and other relevant documents as directed by Engr-inCharge before approval of product. Make :- Havells/ Crompton/Philips/HPL/Surya/Orient or equivalent
S&F in repair LED street light 90 watt made up of pressure die cast aluminium housing environment friendly with high efficiency LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. System Lumen Efficasy ≥120 Lm/W, 10 kV Surge Voltage Protection, Operating Voltage range 140 V - 270 V Make of LED - Cree/Nichia/Osram/Agilent/Lumileds and including fixing arrangement made out of 40 mm bore GI pipe light grade of length not less than 1.2 m, bent to shape, fixed with two pairs of 40 x 5 mm MS flat iron clamps, nuts, bolts & washers to fix the fitting with pole complete all as specified and directed. Note :Contractor have to submit LM 79 and LM 80 report from NABL accredited Lab,Test Certificate and other relevant documents as directed by Engr-inCharge before approval of product. Make :- Havells/ Crompton/ Philips/HPL /Surya/Orient or equivalent
S&F in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium LED Flood Light 100 watt, Tempered protective toughened glass with IP66, and impact resistant with IK07, System Lumen Efficasy ≥120 Lm/W, 10 kV Surge Voltage Protection, , Operating Voltage range 140 V - 270 V including fixing arrangement fixed with two pairs of 40 x 5 mm MS flat iron clamps, nuts, bolts & washers to fix the fitting with pole complete all as specified and directed. Make :- Havells/ Crompton/Philips/HPL/Surya/Orient or equivalent
Taking down & dismantling ceiling fan of 1200 mm sweep & re-winding of stator with super enamelled copper winding wire of existing guage, supply & replacement of ball bearing and insulating material, including heat varnishing, greasing, lubricating, re-assembling, and spray painting complete fan with approved colour, re-fixing the same and making electrical connection with three core PVC insulated unsheathed flexible cord of 1 Sqmm copper conductor complete all as specified and directed. Note :- Supply of Ball bearing of suitable size, lubricants etc, is deemed to be included in quoted rate. Make of bearing :- Tata / SKF / NBC or its equivalent Make of paint :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
Taking down & dismantling ceiling fan of 1400 mm sweep & re-winding of stator with super enamelled copper winding wire of existing guage, supply & replacement of ball bearing and insulating material, including heat varnishing, greasing, lubricating, re-assembling, and spray painting complete fan with approved colour, re-fixing the same and making electrical connection with three core PVC insulated unsheathed flexible cord of 1 Sqmm copper conductor complete all as specified and directed. Note :- Supply of Ball bearing of suitable size, lubricants etc, is deemed to be included in quoted rate. Make of bearing :- Tata / SKF / NBC or its equivalent Make of paint :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
Taking down & dismantling exhaust fan of 250 to 300 mm sweep & re-winding of stator with super enamelled copper winding wire of existing guage, supply & replacement of ball bearing and insulating material, including heat varnishing, greasing, lubricating, re-assembling, and spray painting complete fan with approved colour, re-fixing the same and making electrical connection with three core PVC insulated unsheathed flexible cord of 1 Sqmm copper conductor complete all as specified and directed. Note :- Supply of Ball bearing of suitable size, lubricants etc, is deemed to be included in quoted rate. Make of bearing :- Tata / SKF / NBC or its equivalent Make of paint :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
Taking down & dismantling exhaust fan of 380 to 450 mm sweep & re-winding of stator with super enamelled copper winding wire of existing guage, supply & replacement of ball bearing and insulating material, including heat varnishing, greasing, lubricating, re-assembling, and spray painting complete fan with approved colour, re-fixing the same and making electrical connection with three core PVC insulated unsheathed flexible cord of 1 Sqmm copper conductor complete all as specified and directed. Note :- Supply of Ball bearing of suitable size, lubricants etc, is deemed to be included in quoted rate. Make of bearing :- Tata / SKF / NBC or its equivalent Make of paint :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
S&F fan capacitor 2.50 mfd, electrolytic type suitable for ceiling fan including taking down complete all as specified and directed.
S&F mild steel down rod 1/2” dia (minimum) & 300 mm length including hanging clamp with nut, bolt and rubber suitable for ceiling fan of 1200 / 1400 mm sweep including taking down complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized iron earth lead wire of 4 sqmm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismentaling old unsv ones complete all as specified and as directed by the Engineer-in-Charge.
S&F 4 mm dia GI wire for earth continuity conductor for making connection from earth test point to main DB including taking down old unsv one all as specified and directed by Engr-in-Charge
MS ORIENT ENGINEERING WORKS
M/S B D ENTERPRISE
R K UDYOG
M/s TRIMURTI ASSOCIATE
DEBABROTA ROY CHOWDHURY
M/S JAGRITI ENTERPRISES
SHIVALAYA ENTERPRISES
D K SARKAR
S D CONSTRUCTION CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .