| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | ₹1.4 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹1.6 Cr+₹14.4 L (10.1%)Rejected-Finance | ₹1.6 Cr+₹14.4 L (10.1%) | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹1.8 Cr+₹33.1 L (23.3%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹1.8 Cr+₹33.1 L (23.3%) | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹1.7 Cr+₹28.8 L (20.3%)Rejected-Finance NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.7 Cr+₹28.8 L (20.3%) | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | L5₹1.6 Cr+₹15.4 L (10.8%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.6 Cr+₹15.4 L (10.8%) | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| Sl No | Description | Qty | Unit | LAKSHMI ELECTRICAL ENTERPRISES L1 | M/S SRI BALAJI ENTERPRISES L5 | UNIVERSAL ENGINEERING L4 | devan enterprises L3 | RAMESH BABU CO L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out 3 phase tower AC complete for repair / servicing and overhauling of capacity 4.0 to 4.6 TR Tower type AC after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower etc. and also connecting of refrigerant pipe, drain pipe and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed.
Note :-(i) Refrigerant gas shall be measured and paid separately under respective item of BOQ. | 8 | Each Job | 2,100 ₹16,800 | 1,000 ₹8,000 Lowest | 1,500 ₹12,000 | 7,000 ₹56,000 | 3,800 ₹30,400 |
| 2.00 | Supply and fix PCB (circuit plate) of in-door unit of 4.0 to 4.6 TR Tower type AC complete including taking down existing one complete all as specified and directed. | 3 | Each | 4,000 ₹12,000 | 1,400 ₹4,200 Lowest | 1,500 ₹4,500 | 4,500 ₹13,500 | 2,900 ₹8,700 |
| 3.00 | Supply and fix PCB (circuit plate) of out door unit of 4.0 to 4.6 TR Tower type AC complete including taking down existing one complete all as specified and directed. | 2 | Each | 2,500 ₹5,000 | 1,450 ₹2,900 | 1,500 ₹3,000 | 3,500 ₹7,000 | 290 ₹580 Lowest |
| 4.00 | Supply and fixing Hermetic sealed/Rotory new compressor for 4.0 to 4.6 TR Tower AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of 4.0 to 4.6 TR Tower AC and connection of all pipe line & charging of refrigerant and testing complete including taking down old existing one complete all as specified and directed. | 2 | Each | 45,500 ₹91,000 | 51,000 ₹1,02,000 | 55,000 ₹1,10,000 | 20,000 ₹40,000 Lowest | 25,000 ₹50,000 |
| 5.00 | Removing the window/ split type AC of 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when directed and installing back at original location, testing and commissioning complete all as specified and directed.
Note :- The rate of following deemed to be included in quoted rate :-
a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower
b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower
c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary
d) The unit rate quoted by the tenderer inclusive for Removing, servicing, installation, commissioning and testing of all equipment’s, tools and plants, and back in on final position complete
(e) The work shall be done by a specialized team of Engineer/Technicians of OEM.
(f) Spares will be measured and paid separately.
(g) Refrigerant gas will be measured & paid separately. | 135 | Each Job | 960 ₹1,29,600 | 1,000 ₹1,35,000 | 1,100 ₹1,48,500 | 350 ₹47,250 Lowest | 1,200 ₹1,62,000 |
| 6.00 | Supply and fix polyurethane form insulation indoor to outdoor unit suitable for 1.5 Ton to 2 Ton split type A/C any type and at any location including taking down existing old one complete all as specified and directed. | 130 | RM | 42 ₹5,460 Lowest | 150 ₹19,500 | 150 ₹19,500 | 250 ₹32,500 | 250 ₹32,500 |
| 7.00 | Supply and fix Over load relay (in replacement) suitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing old one complete all as specified and directed. | 20 | Each | 390 ₹7,800 | 300 ₹6,000 | 300 ₹6,000 | 500 ₹10,000 | 10 ₹200 Lowest |
| 8.00 | Supply and fixing Blower motor (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity including taking down existing unserviceable one, complete all as specified and directed. | 7 | Each | 1,950 ₹13,650 | 1,700 ₹11,900 | 1,700 ₹11,900 | 700 ₹4,900 | 500 ₹3,500 Lowest |
| 9.00 | Supply and fix Suction valve suitable for 1.5 Ton/2 Ton of split type AC of existing make complete all as specified and directed. | 10 | Each | 300 ₹3,000 Lowest | 650 ₹6,500 | 650 ₹6,500 | 800 ₹8,000 | 1,500 ₹15,000 |
| 10.00 | Supply and fixing Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto 2.0 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing old one complete all as specified and directed. | 8 | Each | 5,800 ₹46,400 | 7,500 ₹60,000 | 8,000 ₹64,000 | 4,000 ₹32,000 Lowest | 4,200 ₹33,600 |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
24 Jul 2025, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT OF VARIOUS TYPE OF ACs SUMMER APPLIANCES LT DISTRIBUTION SYSTEM PERIODICAL SERVICING INSPECTION OF VARIOUS EARTHING SYSTEM SECURITY LIGHT INFRASTRUCTURE LIGHTENING PROTECTION SYSTEM AND OTHER MISC E M WORKS AT AFTC 2DC AREA AFS JALAHALLI
2025_MES_716926_1
8158/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Garrison Engineer M AF Jalahalli
₹2.3 L
18 Aug 2025
26 Jun 2025
31 Jul 2025
26 Jun 2025
24 Jul 2025
17 Jul 2025
26 Jun 2025 - 3 Jul 2025
Amount
Taking out 3 phase tower AC complete for repair / servicing and overhauling of capacity 4.0 to 4.6 TR Tower type AC after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower etc. and also connecting of refrigerant pipe, drain pipe and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed. Note :-(i) Refrigerant gas shall be measured and paid separately under respective item of BOQ.
Supply and fix PCB (circuit plate) of in-door unit of 4.0 to 4.6 TR Tower type AC complete including taking down existing one complete all as specified and directed.
Supply and fix PCB (circuit plate) of out door unit of 4.0 to 4.6 TR Tower type AC complete including taking down existing one complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for 4.0 to 4.6 TR Tower AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of 4.0 to 4.6 TR Tower AC and connection of all pipe line & charging of refrigerant and testing complete including taking down old existing one complete all as specified and directed.
Removing the window/ split type AC of 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when directed and installing back at original location, testing and commissioning complete all as specified and directed. Note :- The rate of following deemed to be included in quoted rate :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary d) The unit rate quoted by the tenderer inclusive for Removing, servicing, installation, commissioning and testing of all equipment’s, tools and plants, and back in on final position complete (e) The work shall be done by a specialized team of Engineer/Technicians of OEM. (f) Spares will be measured and paid separately. (g) Refrigerant gas will be measured & paid separately.
Supply and fix polyurethane form insulation indoor to outdoor unit suitable for 1.5 Ton to 2 Ton split type A/C any type and at any location including taking down existing old one complete all as specified and directed.
Supply and fix Over load relay (in replacement) suitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing old one complete all as specified and directed.
Supply and fixing Blower motor (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity including taking down existing unserviceable one, complete all as specified and directed.
Supply and fix Suction valve suitable for 1.5 Ton/2 Ton of split type AC of existing make complete all as specified and directed.
Supply and fixing Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto 2.0 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing old one complete all as specified and directed.
Supply and fixing Remote sensing unit (in replacement) upto 2.0 TR split type AC including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing Blower of indoor unit suitable for 1.5 Ton / 2 Ton split AC including taking down existing unserviceable one at any location complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for 1.5 TR capacity split type AC including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed.
Supply and fix discharge valve suitable for 1.5 Ton/2 Ton of split type AC including taking down existing old one complete all as specified and directed.
Supply and fixing Remote assembly corded/cordless (in replacement) for any type and size of split type ACs, upto 2.0 TR including taking down existing old one complete all as specified and directed.
Supply and fixing Condenser Fan motor (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/2.0 TR capacity, including taking down existing old one and complete all as specified and directed.
Supply and fix MS wall bracket suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed.
Supply and fixing Filter (in replacement) suitable for split type Air Conditioner of any make upto 2 TR capacity, including taking down existing old one complete all as specified and directed.
Supply and fixing Front grill (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity, including taking down existing old one all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 1/2" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 1/4" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 5/8" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 3/8" flare size conforming to relevant IS complete all as specified and directed.
Supply and fix PCB board of any make for indoor unit of split AC 1.5 Ton/ 2 Ton including taking down existing one complete all as specified and directed.
Supply and fix as in repair dummy nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed.
Supply and fix dummy nut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed.
Supply and fix as in repair dummy nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed.
Supply and fix as in repair dummy nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed.
Supply and fixing as in repair of flexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for 2 TR capacity split type AC including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed.
Supply and fix Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto 1.5 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing old one all as specified and directed.
Supply and fix as in repair PVC insulated multi stranded copper conductor 3 core 2.5 Sq.mm, including connecting up and taking down existing unserviceable cable of any description and size complete all as specified and directed.
Supply and fix 3 pin metal clad plug top 20 Amps, AC 230 volts for any type of AC including taking down existing unserviceable one complete all as specified and as directed.
Material and labour for shifting of Air Conditioner, Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed. Note :- The rate for following works deemed to be included in quoted rate :- (a) Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas. (j) Fixing of copper tubing of qty of required size.
Material and labour for shifting of Air Conditioner, Window type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed. Note :- The rate for following works deemed to be included in quoted rate :- (a) Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls/window etc and as directed (c) Fixing only AC unit as required and directed (d) Connecting AC unit of window ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc in opening. (e) fixing PVC pipes 50mm dia for outlet of AC unit to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas. (j) Fixing of copper tubing of qty of required size.
Supply and fix flair nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 1/16" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix single phase single pole contactor suitable for 1.5/ 2.0 split type AC complete all as specified and as directed.
Supply and fix old UNSV indoor unit including blower fan , PCB board and all accessories capacity 1.5/2.0 Ton split type A/C including taking down existing unserviceable one any type complete all as specified and directed.
Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed. Make : Havells/ Indo asian/ Legrand
Removing old unserviceable split type air conditioner outdoor unit and deposited in store yard for safe custody and Supply and fix outdoor unit of the split type air conditioner 1.5/2 TR capacity, complete with all accessories such as hermetically sealed compressor and condenser unit, capacitors, relays, fan motor, duly prewired and including connecting of existing refrigerant gas piping, electrical connections and testing etc complete all as specified and directed.
M&L for preventive and comprehensive maintenance of water cooled central AC chiller Plant of capacity 3X 84.5 TR Scroll chiller type Model No – XWC4S-085 AR2 through the OEM i.e, M/s Blue Star for following plants and equipments of WC R 407C DX Scroll chillers Model XWC4S-085 AR2-3x84.5 TR, including complete operations and all as specified and directed by Engineer-in-Charge:- Maintenance schedule of chiller plant :- The contractor shall carry out the following activities during the period of contract :-
(a) Checking and rectification, if abnormal noise, vibration, leakage of oil, refrigerant etc.
(b) Topping up system with refrigerant and oil, replace dehydrators etc.
(c) Checking of operation of oil heater, motor protector, flow switch, loading unloading,O/L etc.
(d) Checking of control valves.
(e) Develop action plan for rectifying, abnormalities if any observed in performance of the system.
(f) To attend break down calls as and when required, investigation, locate defects and submit action plan to rectify the same.
(g) All the maintenance/servicing works should be done in such a way so that the equipment/unit can be used for its optimum performance.
(h) Adjustments in the system to achieve required temperature & RH level as required by the user.
(j) Cleaning of all type of air filters.
(k) Checking the performance of AHUs.
(l) Descaling of copper tubes of the cooling coil(the water circuit) by suitable means as per manufacturer's recommendation and general standards.
(m) Parameters checking before and after servicing.
(n) Cleaning of ducting system having diffusers, grills, dampers etc.
(o) Servicing of evaporators, expansion valves, water cooled condensers, oil cooler, oil pipings, oil filters, refrigerant pipings, refrigerant filters, solenoid and automatic control valves, AHU control panel.
(p) Checking of compressor for its proper working.
(q) Annual pumping-down and restarting as and when required.
(r) Checking of Microprocessor control panel,control boards,transducer of chillers/condensing unit for their correctness and replace if necessary.
(s) Checking of any loose connection in the panels, plant and equipments, tightening of terminal block connections, replacement of blown off fuses, checking of leakage in Compressor etc.
(t) Parameters checking before and after servicing.
(u) Replacing of parts due to normal wear and tear.
Note :- The contractor will provide the following technical services & the unit quoted rate is deemed to be inclusive of the following :-
(i) Comprehensive maintenance of plant is to be carried out by OEM i.e. M/s Blue Star only under the supervision of contractor & Engineer-n-Charge.
(ii) The contractor shall be required to submit a MOU with OEM for the same before commencement of work.
(iii) Visits of service Engineer of OEM at least once in every month and during break down or when urgently required for the inspection, servicing repair, rectification of problem and submission of report.
(iv) The contractor shall be fully responsible for maintaining the plant in operational condition for entire contract period.
(v) Scope of work also includes supply of materials like Timer, Chiller in-out sensors, Filter Drier, cotton waste, grease, gland packing and solenoid coil during AMC.
(vi) Major spare parts required for repair/ replacement will be measured and paid in relevent items. However, cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items shall be deemed to be included in unit quoted rate.
(vii) In case of any spare part not covered under supply only item but found essential for smooth functioning of the plant, cost of same spare part will be deemed to be included in unit quoted rate.
(viii) In case of minor defect, entire Job shall be completed within 06 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 1000/- per hours shall be recovered from the contractor.
(ix) In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspection by Engineer-in-Charge and represantative of OEM of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay, then penalty at the rate of Rs. 2500/- per hours shall be deducted from the dues of the contractor.
(x) Please note that above penalty is exclusively other than the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(xi) The decision of the Accepting Officer in this regard shall be final and binding.
Taking down defective centrifugal/Monoblock pump set 10 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L for rewinding of induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 25 HP motor capacity complete all as specified and as directed.
Supply and fixing in replacement butterfly valve of size 200 mm dia Cl body, both ends flanged duly drilled, EN 593 ,suitable for AC Hot and cold operation , PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed
Supply and replacing pressure gauge round type size 0-100 PSI complete all as specified and as directed. Make : GURU/WAAREE/BAUMER
Supply and fix 4 Pole MCCB ,415 volts,fixed type ,630 Amp, 50 Hz, with rupturing capacity 36 KA with microprocessor based setting with extended terminals,replacement to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments e.i. screws,bolt, nut, washers including taking out of old unserviceable, complete all as specified and directed. Make : ABB/Schneider/Siemens
Supply and replacing power contactor AC operated 3 pole of different type panel board 40 Amp to 100 Amp, with NO and NC complete all as specified and directed. Make : ABB/Schneider/Siemens
Supply and replacement of water flow switch with stem type sensing element probe, 150 psi, 15 Amps, 250 volts testing for proper working complete all specified and directed. Make: Honeywell or equivalent
M&L for rewinding of induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 10 HP motor capacity complete all as specified and as directed.
Taking down defective centrifugal /Monoblock pump set 7.5 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only split casing gaskets suitable for 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 7.5 HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L for rewinding of induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 7.5 HP motor capacity complete all as specified and as directed.
Supply and fixing in replacement butterfly valve of size 125 mm dia Cl body, both ends flanged duly drilled, EN 593 ,suitable for AC Hot and cold operation , PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed
Supply and replacing temperature gauge round type range 0-50 degree centigrade complete all as specified and as directed. Make : GURU/WAAREE/BAUMER
Supply and replacing power contactor AC operated 3 pole of different type panel board up to 32 Amp , with NO and NC complete all as specified and directed. Make : ABB/Schneider/Siemens
Supply and fix 3 Pole MCCB ,415 volts,fixed type ,200 Amp, 50 Hz, with rupturing capacity 36 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments e.i. screws,bolt, nut, washers including taking out of old unserviceable, complete all as specified and directed. Make : ABB/Schneider/Siemens
Supply and replacing thermostat of range 30 degree to 65 degree celcius complete all as directed.
Taking down defective centrifugal /Monoblock pump set 3 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 3 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 3 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 3 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 3 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 3 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 3 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 3 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 3 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 3 HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L for rewinding of cooling tower electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 3 HP motor capacity complete all as specified and as directed.
Supply and replacing MCB 63 Amps TP C Curve 10 KA 415 volts and making all connections complete all as directed. Make : ABB/Schneider/Siemens
Supply and replacing ball valve SS type bulb of size 25 mm dia for heavy duty body type ASTM A105 (Carbon steel forgings) which pressure with stand 69 Bar at 38 Degree centigrade and 5 Bar at 225 Degree centigrade along with category 3BBTC complete all as specified and as directed.Make : L&T/Kirloskar/Kartar
Supply and replacing V belts suitable for 30000 CFM AHU complete all as specified and directed.
Supply and replacing limit switch IEC-337 suitable AHU 3000 door of AC plant complete all as specified.
Supply and fixing in replacement Globe valve of size 125 mm dia Cl body, both ends flanged duly drilled, ISI marked , PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed.
Supply and fixing in replacement Rubber expansion joint with backup flange of size 125 mm dia EPDM body , both ends flanged duly drilled, , fixing with new nuts, bolts, washers complete all specified and directed.
Material and Labour for carrying out the chemical servicing of the AHU capacity 30000 CFM AHU, 84.5 TR & cooling coils by applying the non-aciditic scale removing agent to the fins area of the cooling coil,copper tubes,removing the complete scale deposit across the coil,flushing through and complete blowing out the dirt,cleaning the fan implellers,filter section,fan section and complete cleaning of filters,tightening of all bolts & nuts,renew the rusted bolts & nuts checking the alignment of the drive set and testing & commissioning the Air handling units of AC plant complete all as specified and directed.
S&F as in repair thermal insulation for duct using 19 mm thick Nitrile rubber sheet Class O FM approved , covered with aluminium foil, aluminium self adhesive tapes, etc with overall Mu value 12000 complete all as specified and as directed.
Supply only Regrigerant gas R-32 in manufacturer's sealed cylinder complete all as specified and as directed. (i) Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas filled.
Supply only Regrigerant gas R-407C in manufacturer's sealed cylinder complete all as specified and as directed. (i) Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas filled.
M&L for cleaning the water strainer of size 200mm properly by scrubbing with the help of scruber from inside and taking out all sludge,rust etc complete all specified and directed.
M&L for cleaning the cooling tower properly by scrubbing with the help of scruber from inside and outside,taking out all sludge,rust etc and replacing of existing unservicable fins and servicing & greasing the motor,valve and painting two coats of synthetic enamel paint to exterior surface of existing colour etc complete all specified and directed
Material and labour in repair for 3 core 6 Sqmm XLPE insulated heavy duty electric cable with copper conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole et complete all as specified and directed.Make :- Havells/Polycab/ RPG Asian
Repair and maintenance of inverter type split AC of any capacity / any Make from any location including attending breakdown calls, routine maintenance and servicing ,testing and commissioning all as specified and directed here under :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower. b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower. (c) Testing all copper tube ,joints, leads for any leaking and Top up with the refrigerant gas if necessary. (d) The work shall be done by a specialized team of Engineer/Technicians of OEM.
Supply and fix DC blower fan motor for inverter split AC of 1.5 Ton to 2 Ton and including taking down existing unserviceable one of any capacity and at any location complete all as specified and directed.
Inspection, checking adjustment and minor repair of unserviceable window type AC any type any capacity placed at any location including repair/ replacement of defective parts such as checking of electrical connection, condenser, gas leakage, PCB, condenser fan blade, compressor, PVC pipe etc., complete all as specified and as directed . Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed .
Supply and fixing PCB board of inverter type window type AC for 1.5 Ton/2 Ton including taking down existing unserviceable one at any location complete all as specified and directed.
Supply and fix Filter (in replacement) suitable for window type Air Conditioner of any make up to 1.5/ 2 TR capacity including taking down existing old one complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakages found in the system of window/ split type ACs capacity up to 2 Ton capacity including vacumizing, charging and checking the gas pressure to desire level complete for satisfactory functioning complete all as specified and directed. Note: Toping up of gas shall be measured and paid separately
Supply and fix condenser fan blade suitable for 1.5 Ton split/ window AC including taking down existing unserviceable one and complete all as specified and directed.
Supply and fixing Over load relay (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/ 2 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fixing Condenser coil after disconnecting the refrigerant connection of defective condenser coil unit of window type AC up to and including 1.5/ 2 Ton and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing Front grill (in replacement) suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fixing Thermostat (in replacement) suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fixing Blower motor (in replacement) suitable for window type Air Conditioner of any make up to 1.5/ 2 TR capacity including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for window type AC of capacity 1.5 Ton (in replacement) including disconnecting the electrical and refrigerant connection of defective sealed unit of window type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing unserviceable one complete all as specified and directed.
Supply and fix overload protector for window/ split AC 1.5/2 Ton TR capacity including taking down existing unserviceable one complete all as specified and directed.
Taking out, inspection, checking adjustment and minor repair of unserviceable refrigerator of165/175/180/185/190/260/277/286/290/308/310/315/350/360/375 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose electrical connection etc., cleaning, condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of refrigerating gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed . Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed .
Supply and fixing Chiller tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity, complete all as specified and directed.
Supply and fixing in replacement condensing coil for refrigerator of capacity 308 to 350 Ltr complete all as specified and directed.
Material and labour for Freezer compartment including door and accessories suitable for refrigerator 260, 286,308, 315 and 350 ltrs capacity refrigerator and including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Vegetable tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity, complete all as specified and as directed.
Supply and fixing in replacement condensing coil for refrigerator of capacity 260 to 308 Ltr complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 308 to 350 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed. Note: Topping up of gas will be measured and paid separately
Supply and fixing Evaporator coil, suitable for refrigerator of 260 to 308 ltrs any make size and type (in replacement) complete all as specified and as directed.
Supply and fixing hermetically sealed new compressor (in replacement) for 308 to 350 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 308 to 350 litres complete all as specified and as directed.
Supply and fixing Evaporator coil, suitable for refrigerator of 308 to 350 ltrs any make size and type (in replacement) complete all as specified and directed.
Supply and fixing superior quality plastic/PVC Ice cube tray for refrigerator of capacity 260 Ltrs to 308 ltrs complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 260 to 308 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed. Note:Topping up of gas will be measured and paid separately
Supply and fix in repair electric bulb 20 watt 230v threaded type for refrigerator of Capacity 260 ltrs to 308 ltrs complete all as specified and directed.
Supply and fixing PVC shelf transparent type of tough plastic suitable for refrigerator of capacity 260 to 308 ltrs complete including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing hermetically sealed new compressor (in replacement) for 260 to 308 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 260 to 308 litres complete all as specified and directed.
Supply and fixing in replacement condensing coil for refrigerator of capacity 165 to 260 Ltr complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 260 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed. Note:Topping up of gas will be measured and paid separately
Supply and fix in repair magnetic beading for refrigerator of cap 165 ltrs to 335 ltrs complete all as specified and directed.
Supply and fixing Chiller tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity, all as specified and directed.
Supply and fixing Relay, box type, suitable for refrigerator of any make 165 to 335 litres capacity (in replacement) fixed in repairs, complete all as specified and directed.
Supply and fixing Evaporator coil, suitable for refrigerator of 165 to 260 ltrs any make size and type (in replacement) complete all as specified and directed.
Supply and fixing hermetically sealed new compressor (in replacement) for 165 to 260 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 260 litres complete all as specified and directed.
Material and labour for preparing the old painted surface of refrigerator of capacity 165 litres to 350 litres and spray painting with synthetic enamel paint of approved colour complete all as specified and directed.
Supply and fixing Vegetable tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity, complete all as specified and directed.
Supply and fixing Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator and including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing Thermostat, suitable for refrigerator of any make 165 to 350 litres capacity (in replacement) all as specified and directed.
Supply and fixing in replacement Gasket, suitable for door of Refrigerator of any make, 165 to 350 litres capacity, fixed in repairs all as specified and directed.
Supply and fixing Multi capacitors 2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Servicing the Voltage Stabilizer 0.5 KVA to 2KVA capacity single phase after replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Supply and fixing Filter of refrigerator including taking down existing unserviceable one complete all as specified and as directed.
Servicing the Voltage Stabilizer 4 KVA to 5 KVA capacity single phase after replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Supply and fixing Timer and sensor of Refrigerator including taking down existing unserviceable one complete all as specified and as directed .
Supply and fixing Over load protector for refrigerator including taking down existing unserviceable one any description complete all as specified and as directed..
Supply and fixing Copper capillary tube suitable for refrigerator including taking down existing unserviceable one, any description complete all as specified and directed.
Supply and fixing Starting relay suitable for refrigerator including taking down existing unserviceable one complete all as specified and as directed
Supply and fixing Multi capacitors 4 µfd for cooling appliances including taking down existing unserviceable one all as specified and as directed.
Supply and fixing Multi capacitors 2.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Material and labour for pressure testing and rectifying the leakage found in the system of Deep freezer of capacity 405 litres including vacuuming and charging the refrigerant Refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed. Note:Topping up of gas will be measured and paid separately
Supply and fixing Copper capillary tube of Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
Supply and fixing Condenser fan motor of Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Thermostat for Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing hermetic sealed new compressor (in replacement) 1/6 HP suitable for deep freezer of capacity 405 ltr including disconnecting the electrical and refrigerant connection of defective sealed unit of deep freezer 405 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed
Supply and fixing Filter for Deep freezer including taking down existing unserviceable one complete all as specified and as directed
Supply and fixing Starting relay of Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Over load protector for Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/180 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed . Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed .
Material and labour for pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note:Topping up of gas will be measured and paid separately
Supply and fixing Electric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water cooler of any make of 150/180 litres capacity, complete all as specified and directed.
Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 150 Litres capacity complete all as specified and directed.
Supply and fixing Door gasket (in replacement) suitable for lid of water cooler up to 150 litres capacity, complete all as specified and directed.
Supply and fixing hermetic sealed new compressor (in replacement) for water cooler 150 litre/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 litres and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed.
Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
Material and labour for preparing the old painted surface of the water coolers of capacity 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No. and capacity all as specified and directed.
Material and labour for pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note: Topping up of gas shall be measured and paid separately
Supply and fixing Electric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water cooler of any make of 60/120 litres capacity, including taking down existing one all as specified and directed.
Supply and fixing Self closing push type tap 15mm dia made out of cast copper alloy chromium plated (in replacement) suitable for water cooler conforming to ISI including testing and leak proof etc. complete all as specified and directed.
Supply and fixing ball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity including taking down existing old one all as directed.
Supply and fix in replacement of gun metal gate valve 15mm dia including GI nipple including taking down existing unserviceable one all as specified and as directed
Supply and fixing hermetic sealed new compressor (in replacement) for water cooler 60/120 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed.
Supply and fixing PVC drain out pipe 30mm bore (in replacement) as per existing including providing necessary GI clamps, nut, bolt etc.all as specified and directed
Supply and charging of refrigerant gas R-134a to water cooler, refrigerator and deep freezer air conditioner of any type, make and capacity all as specified and directed. (i) Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas.
Material and labour for pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note: Topping up of gas shall be measured and paid separately
Material and labour for repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed.
Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
Supply and fixing Evaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified directed.
Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 40/ 80 litres capacity all as specified and directed.
Supply and fixing hermetic sealed new compressor (in replacement) for water cooler 40/80 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed.
Supply and fixing Multi capacitors 45 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Carbon (filter) 12” size incl taking down old unsv complete all as specified and as directed.
Supply and fixing Electric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water cooler of any make of 40/80 litres capacity, complete all as specified and as directed.
Supply and fixing Condensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified and as directed.
Supply and fixing Multi capacitors 6 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Material and labour for preparing the old painted surface of the water coolers of capacity up to 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed.
Supply and fix in replacement of filter for water cooler of any size any make complete all as specified and as directed.
Material and labour for taking down of ceiling fan of size 1200/1400mm for safety checking by replacing defective parts/painting/rewinding and re-fixing the ceiling fan after repairs, all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod and winding etc. shall be made as directed by the Engineer-in-Charge which will be measured and paid separately under respective items as Supply only. However, parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement are deemed to be inclusive in quoted rate all as directed.
Note:- The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 224. (a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate.
(b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
(c) Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc will be paid under respective item here-in-after as supply only through proper documentation.
(d) The entire job will be carried out in Air Force stn Jalahalli
(e) Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor's responsibility.
(f) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
(g) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(j) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
(k) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
Supply and install single phase 230V automatic AC load manager suitable for 2TR split AC for auto on/off of 2 Nos AC complete with timer,contactor,Internal wiring etc. including connection of incoming and out going cables including taking down existing unserviceable one complete all as specified and directed. Make: Universal Refrigeration and Engineering or equivalent
Supply and install three phase 440V automatic AC load manager suitable for 4.5TR vertical type split AC for auto on/off of 3 Nos AC complete with timer,contactor,Internal wiring etc. including connection of incoming and out going cables including taking down existing unserviceable one complete all as specified and directed. Make: Universal Refrigeration and Engineering or equivalent
Supply only rotor of ceiling fan of any size complete all as specified and directed.
Supply only fan bearing suitable for ceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF
Supply only fan canopies for ceiling fan size of 1200mm/1400mm complete all as specified and directed.
Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm complete all as specified and directed.
Supply only 'U' clamp for hanging ceiling fan with all nuts, bolts and washers complete all as specified and directed.
Supply only gun metal bush of suitable size for ceiling fan 1200mm /1400 mm sweep complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only outer body of ceiling fan of any size complete all as specified and directed.
Supply only safety pins 40mm to 50mm long with nuts and bolt with washers for ceiling fan of size 1200/1400mm complete all as specified and directed.
Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed.
Supply only blades (made of aluminium) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specified and directed .
Supply only blades (made of aluminium) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length exceeding 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length exceeding 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed.
Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured separately under respective item of BOQ.
Material and labour for winding of ceiling fan motor 1400 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured separately under respective item of BOQ.
Supply and fixing in replacement of unserviceable Ceiling fan 1200mm sweep, energy efficient (ISI marked) with star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing unserviceable one, writing MES No with synthetic enamel paint complete all as specified and directed. Make : Havells/ Bajaj/ Orient. Note:- (a) Old Unserviceable ceiling fan shall be deposited to MES store yard without any extra cost.
M&L core cutting of of size 50 mm dia in stone wall with the help of machine and preparing surface to make good matching with existing surface complete all as specified and directed.
M&L core cutting of of size 50 mm dia in bricks wall with the help of machine and preparing surface to make good matching with existing surface complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables etc up to proper level and laying of pipelines etc in any type of soil, complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed.
Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
Material and labour for well burnt bricks ‘B’ class as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed. (iii) Removing excavated material out side MD land. (iv) Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Supply only of GI pipe light grade for cable protection of size 80mm bore with fittings, complete all as specified and directed.
Material and labour in repair for 3 ½ core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for 3 ½ core 120 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 120 Sqmm to 185 Sqmm, complete all as specified and directed.
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 95 Sqmm to 120 Sqmm 3.5 core of underground LT armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather, vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No. (Incomer). (b) Change over switch 400 A, 4P front operated-01 No (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 320 Amp, 36 KA - 01 No (O/G) (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 25 KA - 02 Nos (O/G) (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (g) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 05 Nos. (c) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (e) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Attending complaints for non-functional/ unserviceable street light/perimeter lights/high mast light/flood light etc of any type/size fitted on poles/walls/post/pillars etc) by deploying technically qualified and experienced technicians to find out defects and taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tape to insulate the LT joint etc and testing complete all as specified and as directed at AF Station West Area Jalahalli.
Note : The following items are deemed to be inclusive of quoted rate :-
The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work.
Contractor or his Authorised Representative has to inspect all Street/ Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very regular basis. (Every succeding day)
A Joint Inspection for Serviceability of all Street/Security Lights will be carried out from 7.00 PM to 9.00 PM on every MONDAY by Engineer-in-Charge/ JE (E/M)/ User along with Contractor or his authorised Representative.
Contractor has to arrange own moveable Generator of suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair. No Electricity shall be provided by the Department on this account.
Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipment's to remove the breakdown. Fault will be intimated through Telephone/ SMS.
Contractor shall provide conveyance to the employed labour for maintaining the services without any extra cost to department.
Vehicle mounted ladder for maitenance services shall be provided by the contractor at no extra cost to department.
Material required for the repairing of the lights shall be measured and paid separately under respective item(s) . But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the lights fittings shall deemed to be included in the rate quoted.
Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the tradesmen deployed for providing the services and department will have no liability for any type of accident. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this account.
All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.
Attending and repairing complaint for one light of any type shall be measured and paid as one Job.
Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.
Contractor has to ensure serviceability of all Street/ Security Lights in above mentioned DOMESTIC & TECHNICAL AREA on Daily basis in any weather condition at their own arrangement.
In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Charge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
The decision of the Accepting Officer in this regards shall be final and binding.
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity of 200 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity of 120 to 150 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity of 80 to 100 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply and fix as in repair NO/NC of capacity suitable for 32-40 A contactor including taking down of old one complete all as specified and as directed . Make:- Legrand /Indo Asian /L&T
Supply only PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. Make : Havells/ Plaza/ Finolex or equivalent
Supply and fix contactor of capacity 32- 40 A 3 Pole 415 V with 2NO+2NC including taking down of old one complete all as specified and as directed .Make:- Legrand /Indo Asian /L& T
Supply and fix MCB 40 Amps, TP, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: , including taking down of old one complete all as specified and as directed and directed. Make:- Legrand /Indo Asian /L& T
Supply and fixing the surge protection device 5KV voltage compatible with industrial and out door type LED fixtures including taking down of old one complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity upto 36 watt LED fittings complete all as specified. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity of 40 to 45 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity of 60 to 75 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
M&L for wiring of unserviciable Timer panel box and replacement of existing size of copper wire with copper lugs and other connected items complete all as specified and as directed
Supply and fix digital timer switch 24 hrs including taking down of old one complete all as specified and as directed. Make:- Legrand /Indo Asian /L&T
Material and labour for applying one coat of cement base paint to RCC pole 9.0 metre long after scraping / brushing and cleaning the pole and street light bracket to be painted with one coat of Aluminium paint. Cement base paint shall be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white with synthetic enamel paint (30 Cms Each) Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete, all as specified and directed.
Material and labour for Painting of steel tubular pole 9.0 metre long, by applying one coat of aluminium paint after scraping / brushing and cleaning the rust on pole and street light bracket. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white with synthetic enamel paint (30 Cms Each). Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete all as specified and directed.
Taking down and errecting steel swaged tubular pole 8.5/9 mtr long, bracket for fixing street light and refixing the same including necessary PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation size of 50 x 50 x 45 cm and coping with 1:2:4, type B1 (using 20 mm graded stone aggregate) complete all as specified and directed.
M &L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copping to pole including necessary form work slightly rounding or squaring, complete all as specified and as directed.
M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete for poles etc, complete all as specified and as directed
Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with black up to 1.5 meter from top of PCC 1:3:6 using 20 mm graded stone aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm graded stone aggregate as in foundation and coping of PCC (1:3:6) type C-1 using 20mm grade stone aggregate including dismantling of old damaged pole complete all as specified and as directed. Note :- (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate.
Supply and fix in repair bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole etc complete all as specified and directed.
Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed.
Supply and fix in repair of LED street light 36 Watt fitting, environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. Make : Philips/CG/Bajaj/ Halonix
Supply and fix in repair of LED street light 45 Watt fitting, environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. Make:Halonix/Philips/CG/Bajaj
Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 70 watt complete all as specified and directed. Make:Halonix/Philips/CG/Bajaj
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 4 Sqmm with multistrand aluminium conductor including taking down of old one complete all as specified and directed. Make: Plaza/Polycab/ Finolex/Havells
Supply and fix in repair Time switch Digital 24 hour, 440 V three phase with contactor TP of rating 32 Amps and MCB TPN of rating 40A fitted in steel enclosure with necessary accessories to fixing RCC/steel tubular pole including bracket, nuts, bolts, washers etc. and making all necessary connections through connectors complete all as specified and as directed. Make : L&T/ Havells/ Indoasian
Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 16 Sqmm to 25 Sqmm 3.5 core of underground LT armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 25 Sqmm to 35 Sqmm, complete all as specified and directed.
Supply and fix in repair LED flood light fitting 200 W integral type light fixture, cast aluminum body, reflector, drivers, LEDs and accessories with system wattage 200W etc complete all as specified and directed. Make : Bajaj/Philips/CG/Halonix.
Supply and fixing in repair LED flood light 150 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD corrosion resistant complete with driver and lamp Protection including street light fitting bracket nuts, bolts, washers complete, all as specified and directed. Make:Halonix/Philips/CG/Bajaj
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/Havells
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 20 KW 3 phase 64 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1using 20 mm graded aggregate for grouting of base including taking down old unserviceable panel etc complete. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity. The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switched as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The GSM controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS, complete all as specified and directed including the following subcomponent, supply and fixing features :-
(a) TPN MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No. (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, C&S Havells) (b) Supply Resign cast CT'S - set of 3 (c) GSM based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 32 Amps -02 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 06 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 Amp rating with brass contacts for INPUT/ and 63 Amp for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring 10 Sqmm flexible. Make- Tricolite/ Kewintech/HPL
Supply and fixing LED flood light 100 watt 230 V AC outdoor type including necessary bracket with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down of old unserviceable fitting of any capacity. Make : Halonix/Philips/CG/Bajaj
Supply and fixing in repair Round spherical garden lighting, post top lantern having B22 holder suitable for LED bulb 10 watt, 220 volt,50HZ,IP65 including suitable dia of GI tubing ,length as per site requirement on gate pillars/ garden lights for fixing the lamp, wiring with 1.5 Sqmm PVC insulated stranded copper conductor including PCC work for fixing, of light fitting complete all as specified and directed.Make: Philips/ Havells/Bajaj/CG.
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 10 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/ Havells
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 12 KW 3 phase 32 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor. Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1 for grouting of base including taking down unserviceable panel etc complete. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, Ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.The panel should have three operation mode :-1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switches as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The Gsm controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS complete all as specified and directed.
(a) MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells) (b) Supply Resign cast CT'S - set of 3 (c) Gsm based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 25 Amps -03 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 03 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 A rating with brass contacts for INPUT/ and 63 A for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 sqmm & power wiring 10 sqmm flexible. Make- Tricolite/ Kewintech/HPL
Material and labour for Testing of earth resistance value from earthing pit test terminal point and write in/ on existing identification board complete all as specified and as directed. Around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip comprising of the following process :-
The following items are deemed to be inclusive of quoted rate :- (i) The above job shall be carried out by a trained technician having ITI in electrical and well known regarding earthing test. Documantary proof of the education of tradesman shall be produced by the contractor to the Engr-in-charge, before commencement of work.
(ii) The aforsesaid test will be carried out in presence of user and MES represnetative.
(iii) Two Party (consisting 2 x 1 No. Technician with 2 x 1 No. Helper) will report every Morning at 9 AM to JE E/M for Daily earth testing.
(iv) Earth Resistance Tester will be provided by the Contractor. (Tester should be caliberated from Authorised Company/ Lab).
(v) Contractor will be responsible for pouring of water in the Earth Pits Weekly at their own arrangement with Water Tanker, etc. (water will be provided by the contractor at his own arrangement and nothing extra will be admissible).
(vi) Contractor will be responsible for marking of Earth check date and due date on existing Plate with synthetic enamel paint as specified by Engineer-in-Charge.
(vii) Contractor will be responsible for cleaning of bushes and grass all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip.
Supply only charcoal dust/Breeze in trenches to improve the ER value of existing earth pits, complete all as specified and as directed.
Supply only common salt commercial in trenches to improve the ER value of existing earth pits, complete all as specified and as directed.
Material and labour for magnesium sulphate (MgSO4) for improvement of earthing resistivity, complete all as specified and directed.
Material and labour for Powder Earthing Backfill Compound, Grade Standard for improvement of earthing resistivity and to increase the absorption of moisture around the earthing electrode, complete all as specified and directed.
Repairing and maintenance of old existing earth pit by taking out carefully earth plate, watering pipe, earth lead protection pipe and re-buried the same after removing sludge from the plate & pipes including re-connection/brazing the plate and strip, whichever is required at site (Earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level,complete all as specified and directed including PCC 1:3:6 type C1 using 20mm graded stone aggregate for pit with cover of RCC 1:2:4 type B1 using 20mm graded aggregate, reinforced with welded steel wire fabric not less than 4 kg per Sqmtr with handle and angle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked, GI funnel with GI mesh,filling with mixture of common salt and charcoal,necessary excavation, refilling, removing away soil and earth work in any type of soil including test point, testing and commissioning, complete all as specifed and as directed. Note : GI Funnel, brazing, mixture of salt/char coal/MgSO4 shall be measured and paid separately under releavant items.
Taking down existing GI earthstrip 25x3mm thick as earthing lead with its accessories and re fixing to wall/roofs etc. drawn in conduit/GI pipe etc all as specified and directed. Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed.
Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal. head screw, complete all as specified and directed.
Supply and fixing in replacement of aluminium strip 25x3mm fixed with epoxy based insulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut and bolt, gutties, screws etc, complete all as speified & directed.
Material and labour for fixing earth indicators made out of 3 mm thick MS sheet of size 200mm x 300mm duly fixed in MS angle iron 25mmx25mmx3mm of 450 mm long to be fixed to ground by means with necessary cement concrete and painting with two coats of synthetic enamel paint over a coat of red oxide primer, writing earth reading and connected items like painting of panel etc, and necessary excavation and earth work including taking down old, complete all as specified and as directed.
Material and labour in repairs Galvanised iron Earth strip of size 32 x 6 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed.
Supply and fixing in repair 40 mm bore galvanised steel water tubing medium grade with all fitting laid in trenches/or lavid in floor etc, complete all as specified anfd directed .
Supply and fixing in repair 20 mm bore galvanised steel water tubing medium grade with all fitting fixed to wall and ceiling or laid in floors etc, complete all as specified and directed.
Supply and Fix in repairs Bib Tap of 15 mm dia standard of PTMT any colour high pressure screwed for iron pipe (Minimum weight 90 gms ), complete all as specifed and directed.
Taking downn unsv funnel of any type and size Supply and fixing in repair GI funnels for earthing, complete all as specified and as directed.
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.
Material and labour for Brazing of copper/Aluminium for continuity, complete all as specified and as directed.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.. Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete including taking down old unserviceable pit cover of any decription all as specified and directed. Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global
Supply only of GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as specified and directed.
Material and labour for Boring of holes under road, pavement, hard standings by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.
Material and labour in repair for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for 3 ½ core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compilaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure shall be above 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description, reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA - 02 Nos (Incomer). (b) On Load Change over front operated of capacity 250 Amp, 4 Pole, 415 V - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 16 KA - 01 No (O/G). (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 95 Sqmm to 120 Sqmm, complete all as specified and directed.
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 25 Sqmm to 35 Sqmm 3.5 core of underground LT armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
Surface dressing in any type of soil not exceeding 15 cm deep and clearing all the grass weeds etc in the sub station yards after removing and keeping existing stone aggregate aside all as directed at site including setting / spreading back the aggregate complete all as specified and directed at site.
Supply and fixing in repair IP65 rated LED Bollard with robust design and efficient light distribution 10 watt on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc., including taking down existing fittings all as per Cat Part No - LBLSN-10-CDL of Make : Crompton or equivalent in Halonix/Bajaj/ Philips
Suply and fix in repairs LED decorative post top lantern fitting 40W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection complete all as specified as directed. Make: Bajaj / Philips/Halonix/ CG
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA - 02 Nos(O/G). (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 03 Nos(O/G). (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 32 Amp, 10 KA - 03 Nos(O/G) (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (g) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 630 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board amplete all as specified and all as directed and comprising of the following:-
(a) ON load change over switch 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No . (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 02 Nos. (c) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No (d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (e) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (vi) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Note :- An amount of Rs 2,27,052.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
RAMESH BABU CO (BID ID -3367579)
devan enterprises (BID ID -3367387)
UNIVERSAL ENGINEERING (BID ID -3366656)
M/S SRI BALAJI ENTERPRISES (BID ID -3366101)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .