| 2 | L2₹70.5 L+₹1.4 L (2.06%)Admitted-Finance 302 APOLLO ARCADE APOLLO ARCADE 7819 AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | ₹70.5 L+₹1.4 L (2.06%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ORBIS ELEVATOR CO LTD L2 | FUJITEC EXPRESS PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00Supplying ,installation , Testing and commissioning of the Passenger cum Bed Elevator , Machine Room Less having following main features: | |||||
| 1.01(a)MOTOR : Gearless lift drive comprising of high starting torque lift duty, 3 phase 440 Volts A.C. permanent magnetic synchronous motor of proper rating with high efficiency shall be used. | |||||
| 1.02(b) Operation / Drive : Microcessor based /PLC, AC Variable Voltage variable frequency variable speed (V3F) vector control drive with encoder feedback closed loop system shall be used for lift car and door operation which shall be full collective selective operation hall call demand response, UP/Down hall stops , main , Up/Down contactor with overload and phase reversal relay and safety controls | |||||
| 1.03( c ) Traction Media: main hoist flat coated steel belt / rope . Thimbles of spring permit adjustment of uniform tension for smooth operation of the elevator Pulse belt monitoring system to avoid the cut in the belt. | |||||
| 1.04(d) Car : car should be with M S platform with bracings of adquate size and to sustain the impact load cabin plus passengers with safety factor of fire for steel with Granite flooring and side panels should be of Stainless steel with Honeycomb/Moonrock Finish of sheet of grade 304 duty with S.S. handrails . Car ceiling shall be steel finish with aesthetic appearances with LED ceiling lights .The size of the car shall be taken as per available lift well size and relevant BIS code of lifts . Car panel will also be of SS 304 grade finished with emergency stop device , emergency alarm,mechanical door safety device ,full length infra-red curtain in car door , facility of auto/attended mode. All car panel buttons and all floor switches must be with brail language as per lift act. The inspection unit shall be provided at the top of the car. | |||||
| 1.05(e)tanding Doors : All landing door shall be fully automatic centre opening / telescopic made of Honeycomb/Moonrock finish stainless steel grade 304 with key holes and infrared curtains with unlocking facility from outside. | |||||
| 1.06(f) Emergency light: Appropriate rechargeable battery operated LED emergency light in the car and along with alarm switch shall be provided. | |||||
| 1.07(g) ARD: Automatic rescue Device (ARD) shall be provided according to passenger capacity with SMF batteries of approved brands as per BSR. | |||||
| 1.08(h) Audio-Visual lndication : Audio visual indication in the lift car , showing over loading such that doors kept open till excess load is removed. | |||||
| 1.09(i) Scrolling lndicators: Digital scrolling indicator system for up-down arrow with floor position indicator shall be provided inside the car and at all stops/floors. | |||||
Tender Value
₹71.2 L
EMD Value
₹1.4 L
Closing Date
28 May 2026, 6:00 pmClosed
Executive Engineer, Medical and Health, Div. Alwar
CMHO Office, Near Nangali Circle, Alwar
SITC of Lift work in SDH Sikrai, Distt. Dausa
2026_MEDIC_560480_1
NIT NO. 04/2026-27(06)eemhalwar
Open Tender
Electrical Works
Percentage
180 days
DAUSA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
BOB, A/C No. 06680100019402, IFSC - BARB0ALWARX
₹1.4 L
11 Jun 2026
19 May 2026
29 May 2026
19 May 2026
28 May 2026
19 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1PART 'A' : ELECTRIC WORK | |||||
| 1.01 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - |
| 1.02 | 25.0 Sq. mm | - | - | - | - |
| 1.03 | 3.5 core | - | Mtr | 285 | - |
| 2Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 2.01 | Short point (up to 3 mtr.) | - | P. point | 359 | - |
| 2.02 | Medium point (up to 6 mtr.) | - | P. point | 578 | - |
| 3Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 3.01 | On board | - | P. point | 357 | - |
| 4Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.74 MB
Tendernotice_2.pdf
PDF • 7.07 MB
Tendernotice_3.pdf
PDF • 1.73 MB
tenderdocs_6.pdf
Tender Documents • 0.40 MB
Annexure_DLP_Condition.pdf
Other Document • 0.42 MB
ELIGIBILITY_CRITERIA.pdf
Other Document • 0.16 MB
BOQ_997638.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .