Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹7.5 LAccepted-AOC NO 19 FIRST CROSS MAIN ROAD ANAND NAGAR NAINARMANDAPAM PUDUCHERRY 605 004 | PUDUCHERRY | PUDUCHERRY | PUDUCHERRY | 605004 | L 1 | Accepted-AOC As per the chart generated L1 is accepted and AOC issued to L 1 | |
| 2 | L 2₹8.3 L+₹76,510 (10.2%)Rejected-Finance NO 52 KOIL MANYAM STREET DHARMAPURI PUDUCHERRY 605 009 | PUDUCHERRY | PUDUCHERRY | PUDUCHERRY | 605009 | L 2 | Rejected-Finance Second Least | |
| 3 | L 3₹8.4 L+₹86,420 (11.5%)Rejected-Finance NO 25 5TH CROSS KATTABOMMAN NAGAR MANAVELY ARIYANKUPPAM PUDUCHERRY 605 007 | PONDICHERRY | PUDUCHERRY | 605007 | L 3 | Rejected-Finance Third Least | |
| 4 | L 4₹8.7 L+₹1.2 L (15.4%)Rejected-Finance | L 4 | Rejected-Finance Fourth Least |
Tender Value
₹8.7 L
EMD Value
₹17,485
Closing Date
28 Nov 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The, Executive Engineer, SBDI, PWD, Puducherry.
Office of the EE,SBDI,PWD,Puducherry.
Urgent repair works to the Terrace and Head Room of PWD Office Building at Gorimedu, Puducherry.
2022_PWDC1_11406_1
21/SBDI/2022-23/4
Open Tender
Civil Works
Item Rate
90 days
Puducherry
Please refer Tender documents.
2 documents required · 2 mandatory
₹525
₹17,485
3 Feb 2023
21 Nov 2022
29 Nov 2022
21 Nov 2022
28 Nov 2022
21 Nov 2022
Amount
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacture's specification.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundations and plinth in - cement mortar 1:4 (1 cement :4 coarse sand).
Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required - in gratings, frames, guard bar, ladder, railings, brackets,gates and similar works.
Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110 mm diameter.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Single tee without door -110x110x110mm.
Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete - 110mm.
12mm cement plaster of mix -1:4 ( 1 cement : 4 fine sand).
6mm cement plaster of mix 1:3 (1 cement : 3 fine sand).
Finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade - New work (two or more coats applied @1.43 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10sqm)
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete.
Repair to plaster of thickness 12mm to 20mm in patches of area 2.5sqm and under including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete.
Cleaning of terrace / loft water storage tank (inside surface area ) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5 gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs.0.10 per litre ) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contracor at his own cost and nothing extra will be paid on this account).
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - in cement mortar.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead - for thickness of tiles 10mm to 25mm.
Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings this included jointing of pipes & fittings with one step ASTM solvent cement, trenching refilling & testing of joints complete (External work) - 25 mm nominal outer dia pipes.
Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings this included jointing of pipes & fittings with one step ASTM solvent cement, trenching refilling & testing of joints complete (External work) - 50 mm nominal outer dia pipes.
Providing and fixing 25mm dia ASTM Half turn valve of approved quality.
Providing and fixing 50mm dia ASTM Half turn valve of approved quality.
Sealing of cracks/porous concrete by Pressure grouting using cement slurry mixed with non shrink expanding grouting compound of CERA/ SIKA/ FOSROC/ Mc Bauchmie/ Don/ BASF or equivalent make certified & tested by accredited institutions. like IIT/SERC or so (Confirming to BS 8110 Part I), mixed in the ratio of 225g per 50Kgs bag of cement for injection grouting the RCC slab to strengthen the RCC Slab.
SETSEAL A-A per packed water proofing two part system coating over the rough plastered surface after wetting the surface including all complete.
Providing a layer of trowel applied cementitious water proofing membrane of 5mm thick nominal SETSEAL TANKING-A pre packed water proofing single part system over the SETSEAL APPLIED primer surface after wetting the surface including all complete.
Removing the loose particles rust / mill scale deposits completely duly cleaning it with wire brush / crush sheet etc., and removing the dust over the old concrete surface and providing and system based aromatic rust remover of CERA / SIKA / FOSROC / Mc. Bauchmie / DON / BASF OR EQUIVALENT make certified and tested by accredited institutions (Confirming to IS 90/7 - 1997 (reaffirmed - 1997) Appendix B, Clause 5.3.3) including all tools complete as per manufacturers specification and as directed by the Engineer-in-charge.
Providing high strength Non shrink free flow micro concrete of (CERA / SIKA / FOSROC / Mc Bauchmie / DON / BASF OR EQUIVALENT make certified and tested by accredited institutions like IIT / SERC / NTH or so (confirming to ASTM C109 7cm cube for compressive strength 45-50 MPa, Physical properties : Tensile Strength - 2.0 N/Sqm @ 28 days (BS 4551-80), Flexural Strength - 5.0 N/Sqm @ 28 days) over the Epoxy bonding agent applied area on columns, slabs, beams etc., upto floor five level (aggregates of 6mm to 12mm chips may be added) (Measurement has to be taken considering 60mm average thickness of prepared surface). For this treatment precise quantity of water ie 0.15 W/P ratio will be maintained for good mortar consistency as per the manufacturers specification with all lead and lift etc., complete and as directed by the Engineer-in-charge (Note : Shuttering and reinforcement wherever required shall be paid separately).
Shifting charges for 2.0 ton Air Conditioner units.
S. SUDEESH
vishnuvarthan
SELVARASU
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .