Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
17 Nov 2020, 6:00 pmClosed
Sh A K Dubey, IDSE , SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
REPAIR/MAINT OF DISTRIBUTION TRANSFORMERS, HT BREAKERS, HT OH LINES STAYS, EARTHING ETC AND ALLED WORKS AT CPH AND MPH UNDER GE (UTILITY) UDHAMPUR
2020_MES_383018_2
CWE/U(U)-76/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Udhampur
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE (Utility) Udhampur
₹70,000
Yes
16 Dec 2020
23 Oct 2020
19 Nov 2020
23 Oct 2020
17 Nov 2020
5 Nov 2020
Amount
Dismantling of unserviceable steel tubular swaged pole/ PCC pole complete with accessories all as directed by Engr-in-Charge.
Dismantling of unserviceable ACSR Conductor of any size from existing over head lines completed all as specified and directed by Engr-in-Charge.
Dismantling of GI earth wire and guard wire from existing OH lines complete all as specified and directed by Engr-in-Charge.
Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed by Engr-in-Charge.
Dismantling of unserviceable stay assembly complete with all accessories complete all as specified and directed by Engr-in-Charge.
Taking down carefully old unserviceable insulator (any type/size) from existing over head lines complete all as specified and directed by Engr-in-Charge.
Dismantling/Taking down of unserviceable/damaged Lightning arrestor, high tension,any type & removing from site of works all as specified and directed by Engr-in-Charge.
Dismantling/Taking down of unserviceable/damaged air break switch of any capacity & removing from site of works all as specified and directed by Engr-in-Charge.
Supply and ererction of steel tubular swaged pole erected to truly vertical or planted as strut complete with 6 mm thick MS Base plate,welded to pole,finial taper cap, bolts, nuts, screws,11 Mtr long, type 410 SP - 55,including drilling of holes of required size for fixing of cross arms,painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the portion embedded in concrete, and marking pole no. with black paint at suitable height all as specified and directed by Engr-in-Charge. Note:- The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’
M&L for ACSR conductor of required size for Over head lines on poles including streching, tightining of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor all as specified and directed by Engr-in-Charge.
M&L for guard cradles made to shape hexagonal rectangular or any other shape as required and fabricated out of galvanized steel wire 8 SWG (4mm dia) including binding wire of suitable size all as specified and directed by Engr-in-Charge.
M&L for continuous earth wire GI 4mm dia for continuos pole earthing including fixing on cross arms all as specified and directed by Engr-in-Charge.
M&L for cross arms of any sizes with drilled hole (hot and cold etc) in position M.S. work including MS nut and bolts, washers and two coats of aluminium paint over one coat of redoxide primer, all as specified and directed by Engr-in-Charge.
Supply, installation and testing HT gang operated air break switch 11 KV, 3 pole vertically mounted type, mechanically operated, mounted on steel frame with operating mechanism, worked from ground level for current upto 200 Amps with drop out fuse elements of required capacity, GOD/switch having 100 MVA rating at 11 KV and 12 insulators suitable for 11 KV, 50 C/s including mounting on HT poles and necessary electrical connections complete all as specified and directed by Engr-in-Charge.
Supply, installation and testing Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp,11000 Volts complete all as specified.
S&F insulator pin type porcelain viterous white, brown or green HT 11000 Volts including 01 galvanized M.S.spindle, two galvanised iron washers and one gal. iron nut of 150mm height and 150 mm dia all as specified and directed by Engr-in-Charge.
S&F insulator Disc type porcelain viterous white, brown or green HT 11000 Volts of size 145 mm high and 255 mm dia ball and socket Type, single disc with tension clampand all as specified and directed by Engr-in-Charge.
S&F in replacement of heavy duty male and female contact of brass Zinc plated for air break switches of 11000 volts, capacity 200 Amps complete all as specified and directed by Engr-in-Charge.
All as per item No 18 above but of capacity 400 Amps.
Servicing and repairing of air break gang operating mechanism device of 11 KV capacity 200/400 Amps with necessary oiling/greasing to moving parts, alignment of Male/Female contacts for proper contacts etc including satisfactory testing for smooth functioning complete all as specified complete all as specified and directed by Engr-in-Charge.
M&L for painting to steel tubular swaged pole of Overhead lines (11 Mtr long) complete with and including comprising the following works :- (a) Scraping out wornout old paint and making the surface smooth. (b) Painting the pole and all MS work mounted on pole with two coats of synthetic enameled paint (Aluminium shade) as directed by Engr-in-charge. (c ) Forming five nos coloured bands at lower portion of pole each 300 mm wide alternatively with white and black colour (or any colour as approved by Engr-in-charge)synthetic enameled paint and marking pole no. with black and white paint complete all as specified.
M&L for stay assembly for steel tubular poles comprising of 7/10 SWG galvanized MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps bolts, nuts, washers, galvanized steel stay rod 20 mm dia 180 cm long bow 400x14mm nuts/bolts, washers all galvanized and two nos thimble, loop insulator of size 90x140mm vitreous, clearance dia of hole 16mm, stayplate of size 230x230x6mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundation and disposal of surplus spoil, upto 50 M all as specified and shown in plate No 1 of MES SSR Pt -I, complete all as specified and directed by Engr-in-Charge.
Supply, laying, commissioning and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 11,000 volts (Earthed) grade cross sectional area 150 sq mm, 3 core including taking down of U/S Cable complete all as specified and directed by Engr-in-Charge
Description all as per Srl item No 23 above but size of cable 120 sqmm 3 core.
Description all as per Srl item No 23 above but size of cable 95 sqmm 3 core.
Excavating in trenches, not exceeding 1.5 m wide and exceeding 1.5 m in depth; for foundation, trenches for laying of cable etc. and getting out in any type of soil, complete all as specified and as directed by Engr-in-Charge.
All as per Srl item No. 26 here in before but depth exc.1.5m but not exc. 3m.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil,complete all as specified and as directed by Engr-in-Charge.
Removing excavated material not exceeding. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed by Engr-in-Charge. NOTE: only punned thickness shall be measured for payment purpose.
Precast unreinforced concrete cable cover class HVP, TYPE 1, flat, size 300mmx180mmx40mm conforming to IS-5820 (1970), for protection of under ground cable, complete all as specified and as directed by Engr-in-Charge. (ISI marked)
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete, all as specified and directed by Engr-in-Charge.
Description all as per Srl item No 32 above but size of cable 120 to 185 sqmm.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete, all as specified and directed by Engr-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete, all as specified and directed by Engr-in-Charge.
M&L for tubing 'light grade'' 150mm bore galvanised iron with all fittings and fixed to poles, walls etc. With flat iron clamps/bolts/nuts/washers or laid in floors/under roads, complete all as specified and as directed by Engr-in-Charge.
Description all as per Srl item No 36 above but of 100mm bore.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete, all as specified and directed by Engr-in-Charge.
Plain cement concrete 1:2:4 type B-1(using 20 mm graded stone aggregate) for coping of poles including necessary formwork, complete all as specified and directed by Engr-in-Charge.
Taking proper shut down in writing and disconnecting the LT and HT electric mains from transformer of capacity 50 KVA to 160 KVA, removing the lid/cover for inspection to facilitate minor repairs at site, draining out the transformer oil reassembling the transformer, refilling the transformer oil (new or old) installing, commissioning and testing at site complete, all as specified and directed by Engr-in-Charge. Note: All the parts required to be replaced and new transformer oil shall be measured and paid for separately.
Description all as per Srl item No 40 here in before but for transformer of capacity exceeding 200 KVA to 315 KVA.
Description all as per Srl item No 40 here in before but for transformer of capacity 400 KVA to 500 KVA.
Description all as per Srl item No 40 here in before but for transformer of capacity 750 KVA.
Taking proper shut down in writing and disconnecting up the LT and HT electric mains from transformer of capacity 50 KVA to 160 KVA removing the transformer from pole structure/platform shifting to authorised workshop after draining out the transformer oil at site, dismantling and disconnecting damaged HT/LT coils to facilitate necessary repairs, rewinding/reconditioning re-assembling the transformer bringing back to the site, refilling new or dehydrated old oil connecting with existing electrical system of HT and LT electric mains including testing complete, all as directed by Engineer-in-Charge Note :-(i) Winding wire and other items mentioned in Sch ‘A’ will be measured and paid separately. (ii) Placing /removing standby transformer in the place of defective transformer under repair will be the responsibility of the contractor, including transportation and man power.( Standby transformer will be provided by the dept )
Description all as per Srl item No. 44 here-in-before but transformer of capacity 200 KVA to 315 KVA.
Description all as per Srl item No. 44 here-in-before but transformer of capacity 400 KVA to 500 KVA.
Description all as per Srl item No 44 here in before but for transformer of capacity 630 KVA to 750 KVA.
M&L for rewinding of HT coil conforming to the original winding of the transformer of any make/capacity with super enamelled cooper wire/strip or DPC copper wire of appropriate gauge and turns including allied materials complete, all as specified and directed by Engr-in-Charge. Make of copper wire/strip:-Atlas/Devidayal
S&F HV bushing with HV bush rod made of brass including nuts, gasket,check nuts and washers complete matching with existing of any model/type of transformer rating 50 KVA to 750 KVA complete, all as specified and directed by Engr-in-Charge.
S&F LV bushing with LV bush rod made of brass including nuts, gasket,check nuts and washers complete matching with existing of any model/type of transformer 50 KVA to 160 KVA complete, all as specified and directed by Engr-in-Charge.
Description all as per Srl item No 50 here-in-before butfor transformer of capacity 200 KVA to 315 KVA.
Description all as per Srl item No 50 here-in-before but for transformer of capacity 400 KVA to 500 KVA.
Description all as per Srl item No 50 here in before but for transformer of capacity exceeding 630 KVA but up to 750KVA.
M&L for gasket set of synthetic rubberized cork sheet with suitable holes for any model transformer rating 50 KVA to 160 KVA all as specified complete, all as specified and directed by Engr-in-Charge.
Description all as per srl item No 54 here-in-before but for transformer of capacity 200 KVA and upto 315 KVA.
Description all as per srl item No 54 here-in-before but for transformer of capacity 400 KVA to 500 KVA.
Description all as per Srl item No 54 here in before but for transformer of capacity 630 KVA to 750 KVA.
M&L for nuts, bolts and washers fully threaded of suitable size as per requirement, all as specified and directed by Engr-in-Charge.
M&L for Spray painting of transformer with one coat of weather proof grey synthetic enamel paint after removing all dust, rust, carbon and oily spots, including well preparation of surfaces and writing /marking SM/MES No as 25mm stencil using white paint complete all as specified including cleaning of temperature gauge and silica gel ,oil temperature level for transformer rating 50 KVA to 160 KVA complete, all as specified and directed by Engr-in-Charge.
Description all as per Srl item No 59 here-in-before but for transformer of capacity 200 KVA to 315 KVA.
Description all as per Srl item No 59 here-in-before but for transformer of capacity 400 KVA to 500 KVA.
Description all as per Srl item No 59 here in before but for transformer of capacity 630 KVA to 750 KVA.
S&F in replacement oil level gauge with glass for transformer rating upto 750 KVA of existing type and size complete all as directed and specified by Engr-in-Charge.
M&L for dry, blue colour silica gel crystal impregnated with cobalt suitable for transformer breather complete, all as specified and directed by Engr-in-Charge.
S&F breather assembly complete with silica gel crystal impregnated with cobalt suitable for any model of transformer rating 50 to 160 KVA to air column of conservator tank complete, all as specified and directed by Engr-in-Charge.
Description al as per Srl items No 65 here-in-before but for transformer of capacity 200 KVA upto 315 KVA.
Description al as per Srl items No 65 here-in-before but for transformer of capacity 400 KVA upto 500 KVA.
Description all as per Srl item No 65 here in before but for transformer of capacity 750 KVA.
Supply only transformer oil of good quality having not less than 50 KV dielectric strength,flash point not less than 135 degree C, having low viscosity for filing complete, all as specified and directed by Engr-in-Charge. Make: Savita/Power oil/Servo oil as per IS 335 of 1983 all as specified. Note: Draining out old unserviceable oil & filling process is deemed to be included in quoted rate in respsctive item.
Re-conditioning of LT coil complete of copper strip/wire any gauge size by providing and wrapping net insulation after removal of old defective insulation and cleaning complete, all as specified and directed by Engr-in-Charge.
S&F temperature gauge suitable for transformer outdoor/Indoor any type with GI nipple etc complete, all as specified and directed by Engr-in-Charge.
Dehydration and filteration of existing serviceable transformer oil at site or at factory permisses of any type,any capacity,any rating transformers till it achieves the required dielectric strength upto 50 KV at 2.5mm gap using dehydration plant complete, all as specified and directed by Engr-in-Charge.
Maintenance and complete overhauling of SF6 gas filled circuit breaker/Isolator including disassembling of operating mechanism parts, well cleaning with petrol and CRC-226, replacing unserviceable parts and accessories, oiling/greasing of moving parts including reassembling, fine setting of mechanism, and making SF6 Breaker in perfect operational in manual and electrical mode including well cleaning the complete panel board, main bus bar, decarbonizing all joints, bus bars, CTs, PTs, spouts metal parts and replacing unserviceable parts and components complete, all as specified and directed by Engr-in-Charge. Make of circuit breaker/Isolator :- ABB Note : (i) Spare parts will be measured and paid seperately as supply only under respective items. The labour charges deemed to be included in the unit rate quoted for this item.
Supply only 3PKE mechanism w/o hex rod item code NHP101935R2 complete, all as specified and directed by Engr-in-Charge.
Supply only terminal protector SILCAB for 11KV item code 1VYN303050-060 complete, all as specified and directed by Engr-in-Charge.
Supply only trip coil 24 V DC item code NHP304453R1 complete, all as specified and directed by Engr-in-Charge.
Supply only close coil 24 V DC item code NHP304453R6 complete, all as specified and directed by Engr-in-Charge.
Supply only O ring 65x5 for LBS Mech Bushing item code NHP402076P24 complete, all as specified and directed by Engr-in-Charge.
Supply only battery, 12V DC,12 AH item code 1VYN401350-173 complete, all as specified and directed by Engr-in-Charge.
Supply only shaft for operating handle item code NHP304961P1 complete, all as specified and directed by Engr-in-Charge.
Supply only ASHIDA ADR241S nano relay with Modbus item code 42004440790.9002 complete, all as specified and directed by Engr-in-Charge.
Supply only push button RED with label "O" item code 1SFA616199R1104 complete, all as specified and directed by Engr-in-Charge.
Supply only push button GREEN with label "I" item code 1SFA616199R1106 complete, all as specified and directed by Engr-in-Charge.
Supply only 2PA mechanism w/o hex rod item code NHP101985R002 complete, all as specified and directed by Engr-in-Charge.
Supply only digital ampere meter 0-300 Amps in HT 11 KV panel including associated wiring complete, all as specified and directed by Engr-in-Charge.
Supply only digital volt meter 0-15 KV in HT 11 KV panel including associated wiring complete, all as specified and directed by Engr-in-Charge.
Maintenance and complete overhauling of 11 KV,3 phase, 800 Amps - 1250 Amps, VCB including disassembling of operating mechanism parts, well cleaning with petrol & CRC-226 including reassembling, panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts and components complete, all as specified and directed by Engr-in-Charge. make of VCB:- Crompton Note:- Spare parts will be measured and paid seperately as supply only under respective items. The labour charges deemed to be included in the unit rate quoted for this item.
Supply only holding catch assembly complete, all as specified and directed by Engr-in-Charge.
Supply only push button Bracket assembly complete, all as specified and directed by Engr-in-Charge.
Supply only charged/discharged indicator assembly complete, all as specified and directed by Engr-in-Charge.
Supply only big and small gear assembly complete, all as specified and directed by Engr-in-Charge.
Supply only closing spring assembly complete, all as specified and directed by Engr-in-Charge.
Supply only triping spring assembly complete, all as specified and directed by Engr-in-Charge.
Supply only trip shaft assembly with spring and trip strips complete, all as specified and directed by Engr-in-Charge.
Supply only close shaft assembly with spring and close strips complete, all as specified and directed by Engr-in-Charge.
Supply only TNC switch complete, all as specified and directed by Engr-in-Charge.
Supply only trip catch assembly with all linkage complete, all as specified and directed by Engr-in-Charge.
Supply only over current/Earth fault relay Numerical 3 Pole,OC/EF Protection Relay complete, all as specified and directed by Engr-in-Charge. Model:- ADR 131A Make:- ASHIDA,aux. 24-230 VAC/DC, CT:1A/5A
Supply only trip Coil 110 V, DC complete, all as specified and directed by Engr-in-Charge.
Supply only control fuses rating 3A to 8Amp HRC type complete, all as specified and directed by Engr-in-Charge. Make: RBCO/GE/L&T
Supply only indication lamps comparising CB ON, CB OFF, Spring charge, trip cuircuit indicators etc.Capacity 3 V DC complete, all as specified and directed by Engr-in-Charge. Note:- Colour code as per existing (R,Y,B,G,W) Make: Siemens/ Kaycee/L&T
Supply only isolating Contact assembly 800 Amp complete, all as specified and directed by Engr-in-Charge.
M&L for flash over carbon cleaning kit consisting of CRCA Super Gasket Remover-400ML- 02 Nos, CRC LECTRA CLEAN-400 ML-04 Nos for cleaning of carbon deposited due to flash over on bus bars and insulators complete, all as specified and directed by Engr-in-Charge. Make: Hy poxy or equivalent.
M&L for moisture removing cum protection Kit consisting of CRC-2-26-500ML 06 Nos, LECTRA CLEAN-400 ML 06 Nos complete, all as specified and directed by Engr-in-Charge. Make: Hy poxy or equivalent.
M & L for Cutting of branches/trimming of trees all around to 3 m distance to all sides over HT feeders between Tawi power house to Tawi Jack well installations and removing the spoil up to a distance exceeding 100mtr away from site area all as specified and directed. Note: For mode of measurement longitudinal distance between the poles shall be measured.
MOHAN LAL AND SONS
PREM NATH KHAJURIA AND SONS
proach associates
slathia construction works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .