| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹62.4 L+₹7.2 L (13.0%)Rejected-Finance 0 00 NEAR KRISHNA PETROL PUMP GEEDAM ROAD JAGDALPUR BASTAR CHHATTISGARH 494001 | BASTAR | CHHATTISGARH | 494001 | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | Rejected-Technical | - | Rejected-Technical Two class below eligible category |
| Sl No | Description | Qty | Unit | H S KALSI AND BROS L1 | POOJA ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | M&L demolition of old existing rubbish/battered/useless mixture on concrete/brick wall, column, beam ceilling of the binding materials such as cement / Lime and fine aggregate(<4.5mm retained on IS Sieve), loose/unsound weaken mixture of binding materials such as cement / Lime and coarse Aggregate (>4.5mm retained on IS Sieve),fine Aggregate of any description and in any position from existing external/internal surfaces of RC components or any surface having average profundity of 15mm by hand tool that has a long metal blade with a sharp edge at the end chisel and hammer or used robust pneumatic chisel hand tools and removal beyond MoD land(distance exe 5.0 km but n.exe 20 km) including cutting of all edges, making square shoulders of the aperture, coarsen the smooth surfaces, curettage /removing of all deterioated/decayed on loose surface including M&L for applying one coat of mixture of two monomer unsaturated liquid hydrocarbon and gaseous hydrocarbon and polymesrized them to get the high polymer dispersion emulsion can be successfully bond to cement mortar, which improved adhesion to concrete, offers the better durability, reduced the shrinkage and increased the flexibility and resistant to emulsification in damp condition modified Ensuring no porosity in new/old surface on dilapidated girders or reinforcement encased in concrete complete all as specified and directed by Engr-in-charge.
Note:-
(i) The applied coat shall resist to penetration of CO2
(ii) The compressive strength shall be 11.5 (N/mm2 ) @ 28 days
(iii) The work will be executed in different buildings and at scattered locations.
(iv) This item shall be undertaken by the authorised rep of manufacturer.complete all as specified. | 1,119 | Sqm | 250 ₹2,79,750 Lowest | 800 ₹8,95,200 |
| 2.00 | M&L for perforation in RCC structure such as Column, beam, window projectin etc using twist & rotating mechanical cutting tool up to a profundity of 15 to 18 mm dia including expelling of inner dust, etc by mechanical machine ( using vacuum pressure to suck dirt ) including providing and fixing of heavy grade GIP perforated nipple 15 mm dia, 50 mm long, @ 1.0 Mtr C/C in one as well as other perpendicular direction and including injecting of PCM blended with using integral water proofing liquid admixture for mixture of coarse (>4.5mm retained on IS Sieve), & fine aggregate (<4.5mm retained on IS Sieve), with cement / mixture of fine aggregate with cement and compound which makes surface impervious to water for cement based concrete and mortar Chemical Confirms to IS 2645-2003, having Specific Gravity 1.1-1.2 gms/cc, ClO3– Nil as per IS 2645-2003. The mixture shall be made using plasticized expanding cementitious admixture and hydrolysis resistant primer cement modifier, provides excellent bond to concrete, improves tensile and flexural properties of mortar, Versatile and water-based lignosulphonates concrete bonding agent chemical, reduces the water demand for required workability and minimises segregation and bleeding, minimize permeability and increase the waterproofing properties of concrete and mortars complete all as specified and directed by engineer in charge.
Note: -
(i) The following properties shall be achieved :-
(a) Permeability to water : Less than 15% as compared to 50% max allowable under IS:2645 , non- toxic
(b) Flexural strength 5 (N/mm2 ) (B S 6319)
(c) Compressive Strength 30 (N/mm2) using expending power grout admixture with plasticizer and Chemical cementations based plasticized grout admixture cement bag through nipple and closing ends nipple epoxy putty/silica jelly after injecting the chemicals mixed with PCM
(ii) The work will be executed in different buildings and at scattered locations.
(iii) This item shall be undertaken by the authorized rep of manufacture. | 264 | Sqm | 250 ₹66,000 Lowest | 500 ₹1,32,000 |
| 3.00 | M&L for applying hydraulic binders, osmotic and complexing admixtures, passivation additives conforming to EN 1504-7-2006 on corroded visible steel forming a continuous film not less than 300 micro of single component for providing and applying passivating protective matrix having compressive strength 25 N/mm2 (on 28th day) ,modulus of rupture 6.5 N/mm2 (28 d.) and preparing the surface to receive the blend of epoxy and sand including providing necessary proportions including supported timber Scaffolding to relieve the members as required and as per design and pattern including preparing the surface to match with the existing surface complete all as specified and directed by Engr-in-charge.
Note-
(i) The work will be executed in different buildings and at scattered locations.
(ii) This item shall be undertaken by the authorised rep of manufacturer. | 160 | Sqm | 250 ₹40,000 Lowest | 700 ₹1,12,000 |
| 4.00 | M&L for one component Impermeable on wall, Roof, projection to aggressive elements, Chloride free, safe for use in prestressed and reinforced concrete, alkali resistant synthetic fibres for exceptional resistance to cracking shear thinning fibre reinforced polymer modified , Impermeable to aggressive elements, dual shrinkage compensated, cementitious repair mortar 20mm thick with alkali resistant synthetic fibres for exceptional resistance cracking, conforming to ASTM C 109 & ASTM C 348 at the outer or inner RC surface mixed with shear thinning fibre reinforced polymer modified repair mortar in the ratio 0.25:1 and mixed with cement mortar modifier of AR for gauging liquid for cementitious systems with specially adhered to BS 6319 having Specific Gravity of 1.025 to 1.04, minimum = 43% solid contents)< 2% by weight of cement and as per manufactures’ instructions complete all as specified and directed.
Note:-
(i) The mortar shall have physical characteristics as under:-
(a) Fexural strength @ 7 days > 7N/mm2,
(b) Tensile strength @ 7days> 3 N/mm2,
(c) Compressive strength @ 35Mpa at 7 day and 45Mpa at 28 days,
(d) Adhesion bond strength > 2 N/mm2
(e) Creep Strain Reduction - 10%
(ii) This mortar can also be used on external or internal surface of RC component / any brick or stone wall surface etc.
(iii) Top surfaces of the plaster shall be finished even and smooth with using extra cement and the quoted rate shall be inclusive of the same.
(iv) The work will be executed in different buildings and at scattered locations.
(v) The rate enclusive of cleaning and making good and disturbed surface.
(vi) This item shall be undertaken by the authorised rep. of manufacturer. | 360 | Sqm | 1,800 ₹6,48,000 | 1,455 ₹5,23,800 Lowest |
| 5.00 | M&L for applying hydraulic binders, osmotic and complexing admixtures, passivation additives passivating protective matrix and welded MS wire cloth with additives reduce or eliminate internal rust and corrosion by neutralizing acids and forming a chemical protective barrier to repel moisture from metal surfaces corrosion inhibiting additive, primer MUCIS for exposed corroded visible steel forming a continuous film not less than 250 micron of single component conforming to EN 1504-7-2006 and preparing the surface to receive the blend of epoxy and sand including providing necessary proportions complete all as specified and directed by Engr-in-charge.
Note-
(i) This item shall be undertaken on observed reinforcement of RCC component facias/floor, any brick or stone inner or outer wall surface etc, weighing not less than 1 kg/sqm applying 20mm thick one component chloride free shear thinning fibre reinforced polymer modified, Impermeable to aggressive elements, dual shrinkage compensated, cementitious repair mortar, alkali resistant synthetic fibres for exceptional resistance cracking. Repair mortar in the ratio of 0.33:1:4 mixed with cement and fine aggregate(<4.5mm retained on IS Sieve) water based lignosulphonates concrete bonding agent water Less than 15% as compared to 50% max. allowable under IS:2645, having SG 1 to 1.2 gm/cc, chloride content : Nil as per IS 2645-2003 over and including hydrolysis resistant primer cement modifier, provides excellent bond to concrete, Improves tensile and flexural properties of mortar, to be applied on surface before application for mixture of cement and fine aggregate (<4.5mm retained on IS Sieve) , chemicals in ratio as per recommendation of manufacturer total chemical not less than 5% by weight of cement complete all as specified and directed by Engineer-in-charge.
(i) The work will be executed in different buildings and at scattered locations.
(ii) This item shall be undertaken by the authorised rep of manufacturer. | 500 | Sqm | 3,000 ₹15,00,000 | 1,855 ₹9,27,500 Lowest |
| 6.00 | M&L for applying compound 20mm thick with 0.25: 1 cement mortar, on roof free from segregation and bleeding. eliminating the microcracking due to shrinkage high workability , corrosion resistant and very low water cement ratio a special high strength cement containing accelerating and highly fluidifying additives in concrete mixture obtained by adding to the correct dosage of accurately selected aggregate, over and including applying granolithic E-Resin based solvent free concrete bonding agent/EP in accurate proportion with complete homogeneity having compressive strength on existing concrete substrate etc complete including all tools and tackles as specified and directed.
NOTE:-
(i) Roof treatment should be done after removing of GI/CI or any other pipe and PVC tank of any capacity and after completion of roof treatment all sanitary items will be re-fixed, the rate of disconnection and re-fixing inclusive of quoted rates. Any damage to solar panels and earthing strips if present will be rectified by contractor and inclusive of quoted rates.
(ii) The compressive strength of compound shall be (ASTM C 109)-80 Mpa@ 28 days, Tensile strength 4Mpa @ 28 days, modulus of rupture -27 KN/sqmm(ASTM D469), Expansion characteristics(ASTM c 827-1987) Unrestrained expansion upto 4% pressure to restrain plastic Expansion -Approx. 0.004 N/mm.
(iii) The granolithic chemicals having mix density of 1.45 to 1.5 kg/litre, compressive strength (BS 6319 pt.2)-40 Mpa at 7 days, Flextural strength (BS 6319 pt.3)-25 Mpa at 7 days, Tensile strength(BS 6319 pt . 7)-15Mpa at 7 days, Bond strength (ASTM C 881)-11 N/sqmm at 7 days,
(iv) pouring of using suitable arrangement as required using pumping device for uniform flow of . ensuring proper bond between the metallic aggregates.
(v) The work will be executed in different buildings and at scattered locations.
(vi) This item shall be undertaken by the authorised rep of manufacturer. | 259 | Sqm | 3,000 ₹7,77,000 | 2,555 ₹6,61,745 Lowest |
| 7.00 | Perforation in RC Column and beam using twist & rotating mechanical cutting tool for Fastening to concrete for chemical anchoring having a Rapid strength gain, Vibration resistant, Corrosion resistant of reinforcement on existing RC Component with Hilti HIT-HY70 BS 5080 or equivalent typically attains a compressive strength in excess of 20N/mm2 @ 3 hours and an ultimate compressive strength of 70N/mm2 in 7 days as per BS 6319 Part 2 : 1983. maximum hole depth 75mm, steel bar 12mm dia and drill bit size14mm with polyster resin based anchoring material for H/V/Large annular applications or post installed bars or in accordance with bar thickness. Complete all as specified and directed by Engr-in-charge.Note- this item shall be undertaken by the authorised rep. of manufacturer. | 130 | Each | 350 ₹45,500 Lowest | 950 ₹1,23,500 |
| 8.00 | M&L for applying two component, cementitious flexible, elastomeric compound coating on roof , roof projection, wall, which makes surface impervious to water for concrete surfaces with high performance cement using acrylic modified elastomeric compound coating with additives reduce or eliminate internal rust and corrosion by neutralizing acids and forming a chemical protective barrier to repel moisture from metal surfaces corrosion inhibiting additive and estomeric compound coating for positive and negative water pressure on RCC Component ,facias/any brick/Concrete/stone inner or outer wall surface etc. complete all as specified and directed.
NOTE:-
(i) The chemical shall comply to ASTM D4541, ASTM C836, DIN 1.048, ASTC D412 having shore hardness D Scale = 20 after application.
(ii) The coating shall be Non-Volatile, low Temperature Feasibility Test, Tensile strength > 0.4 Mpa, Elongation > 20% Cleaning,
(iii) The chemical shall be mixed using slow speed electric drill and application of 2 coats polymer modified using impervious liquid admixture and compound-based concrete and mortar conforming to IS 2645 - 2003 of chemicals as approved by Engineer-in-charge.
(iv) Top of the Surface shall be furnished even and smoother with extra cement including all finishing the surface of match with the existing surface and the quoted rate shall be inclusive of the same.
(iv) The work will be executed in different buildings and at scattered locations.
(v) This item shall be undertaken by the authorised rep of manufacturer. | 500 | Sqm | 390 ₹1,95,000 Lowest | 555 ₹2,77,500 |
| 9.00 | M&L for applying two coats of water based Alicyclic emulsion sealer for resistance to aggressive agents like atmospheric gases-excellent barrier to carbon dioxide, chloride ions, sulphates, oxygen, water, UV rays and rain, efflorescence and lime blooming over and including a coat of water based acrylic polymer primer on prepared surface complete all as specified and directed.
Note:
(i) The coating contains special glass fibres to maintain anti cracking properties for concrete/ Masonry,
(ii) Acrylic emulsion Sealer Coat chemical as approved shall have High performance Water Based aliphatic protective coating to new or old concrete & masonry surface.
(iii) The primer shall be applied after proper surface Preparation, cleaning of dust, dirt etc.
(iv) System should be application of water based acrylic polymer primer coating on prepared surface at 260-280 microns WFT @ 200 microns DFT using by only roller in any mechanical movers.
(v) The Over coating shall be laid after 8 hours of air dry.
(vi) The work will be executed in different buildings and at scattered locations.
(vii) This item shall be undertaken by the authorised rep of manufacturer. | 360 | Sqm | 250 ₹90,000 Lowest | 575 ₹2,07,000 |
| 10.00 | M&L for Structural strengthening with application of expanding powered or dual shrinkage compensating non shrink free flow for Mending to cracks and existing deteriorat surface of RC component and similar work up to 15mtrs height from normal ground level by using plasticized expanding cementitious grout admixture, low permeability and long term durability, high fluidity with low water/cement ratio as per manufacture instructions complete all as specified and directed by Engr-in-charge.
Note- (i) The work will be executed in different buildings and at scattered locations.
(ii) this item shall be undertaken by the authorised rep. of manufacturer. | 250 | RM | 135 ₹33,750 Lowest | 250 ₹62,500 |
Tender Value
₹90 L
EMD Value
₹1.6 L
Closing Date
18 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Tughlakabad
HQ CWE AF TUGHLAKABAD AF STATION, TUGHLAKABAD PO SANGAM VIHAR NEWDELHI-110080
REPAIR AND REHABILITATION TO MES BLDGS IN THE TECH AREA INCL OTM BLDGS OOUTSIDE TECH AREA AND MES INSTALLATIONS OF PALAM UNDER GE (AF) GURGAON NO.1
2025_MES_714895_2
CWE/TKD/GUR/TOKEN-32 OF 2025-26
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Gurgaon No 1
as per NIT condition
7 documents required · 7 mandatory
₹0
₹1.6 L
9 Oct 2025
29 Jul 2025
20 Aug 2025
29 Jul 2025
18 Aug 2025
5 Aug 2025
Amount
M&L demolition of old existing rubbish/battered/useless mixture on concrete/brick wall, column, beam ceilling of the binding materials such as cement / Lime and fine aggregate(<4.5mm retained on IS Sieve), loose/unsound weaken mixture of binding materials such as cement / Lime and coarse Aggregate (>4.5mm retained on IS Sieve),fine Aggregate of any description and in any position from existing external/internal surfaces of RC components or any surface having average profundity of 15mm by hand tool that has a long metal blade with a sharp edge at the end chisel and hammer or used robust pneumatic chisel hand tools and removal beyond MoD land(distance exe 5.0 km but n.exe 20 km) including cutting of all edges, making square shoulders of the aperture, coarsen the smooth surfaces, curettage /removing of all deterioated/decayed on loose surface including M&L for applying one coat of mixture of two monomer unsaturated liquid hydrocarbon and gaseous hydrocarbon and polymesrized them to get the high polymer dispersion emulsion can be successfully bond to cement mortar, which improved adhesion to concrete, offers the better durability, reduced the shrinkage and increased the flexibility and resistant to emulsification in damp condition modified Ensuring no porosity in new/old surface on dilapidated girders or reinforcement encased in concrete complete all as specified and directed by Engr-in-charge. Note:- (i) The applied coat shall resist to penetration of CO2 (ii) The compressive strength shall be 11.5 (N/mm2 ) @ 28 days (iii) The work will be executed in different buildings and at scattered locations. (iv) This item shall be undertaken by the authorised rep of manufacturer.complete all as specified.
M&L for perforation in RCC structure such as Column, beam, window projectin etc using twist & rotating mechanical cutting tool up to a profundity of 15 to 18 mm dia including expelling of inner dust, etc by mechanical machine ( using vacuum pressure to suck dirt ) including providing and fixing of heavy grade GIP perforated nipple 15 mm dia, 50 mm long, @ 1.0 Mtr C/C in one as well as other perpendicular direction and including injecting of PCM blended with using integral water proofing liquid admixture for mixture of coarse (>4.5mm retained on IS Sieve), & fine aggregate (<4.5mm retained on IS Sieve), with cement / mixture of fine aggregate with cement and compound which makes surface impervious to water for cement based concrete and mortar Chemical Confirms to IS 2645-2003, having Specific Gravity 1.1-1.2 gms/cc, ClO3– Nil as per IS 2645-2003. The mixture shall be made using plasticized expanding cementitious admixture and hydrolysis resistant primer cement modifier, provides excellent bond to concrete, improves tensile and flexural properties of mortar, Versatile and water-based lignosulphonates concrete bonding agent chemical, reduces the water demand for required workability and minimises segregation and bleeding, minimize permeability and increase the waterproofing properties of concrete and mortars complete all as specified and directed by engineer in charge. Note: - (i) The following properties shall be achieved :- (a) Permeability to water : Less than 15% as compared to 50% max allowable under IS:2645 , non- toxic (b) Flexural strength 5 (N/mm2 ) (B S 6319) (c) Compressive Strength 30 (N/mm2) using expending power grout admixture with plasticizer and Chemical cementations based plasticized grout admixture cement bag through nipple and closing ends nipple epoxy putty/silica jelly after injecting the chemicals mixed with PCM (ii) The work will be executed in different buildings and at scattered locations. (iii) This item shall be undertaken by the authorized rep of manufacture.
M&L for applying hydraulic binders, osmotic and complexing admixtures, passivation additives conforming to EN 1504-7-2006 on corroded visible steel forming a continuous film not less than 300 micro of single component for providing and applying passivating protective matrix having compressive strength 25 N/mm2 (on 28th day) ,modulus of rupture 6.5 N/mm2 (28 d.) and preparing the surface to receive the blend of epoxy and sand including providing necessary proportions including supported timber Scaffolding to relieve the members as required and as per design and pattern including preparing the surface to match with the existing surface complete all as specified and directed by Engr-in-charge. Note- (i) The work will be executed in different buildings and at scattered locations. (ii) This item shall be undertaken by the authorised rep of manufacturer.
M&L for one component Impermeable on wall, Roof, projection to aggressive elements, Chloride free, safe for use in prestressed and reinforced concrete, alkali resistant synthetic fibres for exceptional resistance to cracking shear thinning fibre reinforced polymer modified , Impermeable to aggressive elements, dual shrinkage compensated, cementitious repair mortar 20mm thick with alkali resistant synthetic fibres for exceptional resistance cracking, conforming to ASTM C 109 & ASTM C 348 at the outer or inner RC surface mixed with shear thinning fibre reinforced polymer modified repair mortar in the ratio 0.25:1 and mixed with cement mortar modifier of AR for gauging liquid for cementitious systems with specially adhered to BS 6319 having Specific Gravity of 1.025 to 1.04, minimum = 43% solid contents)< 2% by weight of cement and as per manufactures’ instructions complete all as specified and directed. Note:- (i) The mortar shall have physical characteristics as under:- (a) Fexural strength @ 7 days > 7N/mm2, (b) Tensile strength @ 7days> 3 N/mm2, (c) Compressive strength @ 35Mpa at 7 day and 45Mpa at 28 days, (d) Adhesion bond strength > 2 N/mm2 (e) Creep Strain Reduction - 10% (ii) This mortar can also be used on external or internal surface of RC component / any brick or stone wall surface etc. (iii) Top surfaces of the plaster shall be finished even and smooth with using extra cement and the quoted rate shall be inclusive of the same. (iv) The work will be executed in different buildings and at scattered locations. (v) The rate enclusive of cleaning and making good and disturbed surface. (vi) This item shall be undertaken by the authorised rep. of manufacturer.
M&L for applying hydraulic binders, osmotic and complexing admixtures, passivation additives passivating protective matrix and welded MS wire cloth with additives reduce or eliminate internal rust and corrosion by neutralizing acids and forming a chemical protective barrier to repel moisture from metal surfaces corrosion inhibiting additive, primer MUCIS for exposed corroded visible steel forming a continuous film not less than 250 micron of single component conforming to EN 1504-7-2006 and preparing the surface to receive the blend of epoxy and sand including providing necessary proportions complete all as specified and directed by Engr-in-charge. Note- (i) This item shall be undertaken on observed reinforcement of RCC component facias/floor, any brick or stone inner or outer wall surface etc, weighing not less than 1 kg/sqm applying 20mm thick one component chloride free shear thinning fibre reinforced polymer modified, Impermeable to aggressive elements, dual shrinkage compensated, cementitious repair mortar, alkali resistant synthetic fibres for exceptional resistance cracking. Repair mortar in the ratio of 0.33:1:4 mixed with cement and fine aggregate(<4.5mm retained on IS Sieve) water based lignosulphonates concrete bonding agent water Less than 15% as compared to 50% max. allowable under IS:2645, having SG 1 to 1.2 gm/cc, chloride content : Nil as per IS 2645-2003 over and including hydrolysis resistant primer cement modifier, provides excellent bond to concrete, Improves tensile and flexural properties of mortar, to be applied on surface before application for mixture of cement and fine aggregate (<4.5mm retained on IS Sieve) , chemicals in ratio as per recommendation of manufacturer total chemical not less than 5% by weight of cement complete all as specified and directed by Engineer-in-charge. (i) The work will be executed in different buildings and at scattered locations. (ii) This item shall be undertaken by the authorised rep of manufacturer.
Perforation in RC Column and beam using twist & rotating mechanical cutting tool for Fastening to concrete for chemical anchoring having a Rapid strength gain, Vibration resistant, Corrosion resistant of reinforcement on existing RC Component with Hilti HIT-HY70 BS 5080 or equivalent typically attains a compressive strength in excess of 20N/mm2 @ 3 hours and an ultimate compressive strength of 70N/mm2 in 7 days as per BS 6319 Part 2 : 1983. maximum hole depth 75mm, steel bar 12mm dia and drill bit size14mm with polyster resin based anchoring material for H/V/Large annular applications or post installed bars or in accordance with bar thickness. Complete all as specified and directed by Engr-in-charge.Note- this item shall be undertaken by the authorised rep. of manufacturer.
M&L for applying two component, cementitious flexible, elastomeric compound coating on roof , roof projection, wall, which makes surface impervious to water for concrete surfaces with high performance cement using acrylic modified elastomeric compound coating with additives reduce or eliminate internal rust and corrosion by neutralizing acids and forming a chemical protective barrier to repel moisture from metal surfaces corrosion inhibiting additive and estomeric compound coating for positive and negative water pressure on RCC Component ,facias/any brick/Concrete/stone inner or outer wall surface etc. complete all as specified and directed. NOTE:- (i) The chemical shall comply to ASTM D4541, ASTM C836, DIN 1.048, ASTC D412 having shore hardness D Scale = 20 after application. (ii) The coating shall be Non-Volatile, low Temperature Feasibility Test, Tensile strength > 0.4 Mpa, Elongation > 20% Cleaning, (iii) The chemical shall be mixed using slow speed electric drill and application of 2 coats polymer modified using impervious liquid admixture and compound-based concrete and mortar conforming to IS 2645 - 2003 of chemicals as approved by Engineer-in-charge. (iv) Top of the Surface shall be furnished even and smoother with extra cement including all finishing the surface of match with the existing surface and the quoted rate shall be inclusive of the same. (iv) The work will be executed in different buildings and at scattered locations. (v) This item shall be undertaken by the authorised rep of manufacturer.
M&L for applying two coats of water based Alicyclic emulsion sealer for resistance to aggressive agents like atmospheric gases-excellent barrier to carbon dioxide, chloride ions, sulphates, oxygen, water, UV rays and rain, efflorescence and lime blooming over and including a coat of water based acrylic polymer primer on prepared surface complete all as specified and directed. Note: (i) The coating contains special glass fibres to maintain anti cracking properties for concrete/ Masonry, (ii) Acrylic emulsion Sealer Coat chemical as approved shall have High performance Water Based aliphatic protective coating to new or old concrete & masonry surface. (iii) The primer shall be applied after proper surface Preparation, cleaning of dust, dirt etc. (iv) System should be application of water based acrylic polymer primer coating on prepared surface at 260-280 microns WFT @ 200 microns DFT using by only roller in any mechanical movers. (v) The Over coating shall be laid after 8 hours of air dry. (vi) The work will be executed in different buildings and at scattered locations. (vii) This item shall be undertaken by the authorised rep of manufacturer.
M&L for Structural strengthening with application of expanding powered or dual shrinkage compensating non shrink free flow for Mending to cracks and existing deteriorat surface of RC component and similar work up to 15mtrs height from normal ground level by using plasticized expanding cementitious grout admixture, low permeability and long term durability, high fluidity with low water/cement ratio as per manufacture instructions complete all as specified and directed by Engr-in-charge. Note- (i) The work will be executed in different buildings and at scattered locations. (ii) this item shall be undertaken by the authorised rep. of manufacturer.
M & L for applying a curing coating layer on roof , colmn beam and Chhjjas by providing adequate moisture, temperature and time to allow the surface to achieve the desired properties for its intended use by using viscosity alkali reactive wax based compound in which liquid substance that is added as a surface coating on repaired concrete surface for reducing the loss of water or heat in order to create ideal conditions that are favourable to the increase in the strength of concrete, the rate of application shall be within the range of 200 to 285 ml/m2, including all tools and tackles complete all as specified and directed by Engr-in-charge. Note- (i) The work will be executed in different buildings and at scattered locations. (ii) This item shall be undertaken by the authorised rep. of manufacturer.
M&L for applying alkaline based compound corrosion inhibitors and dispersing agents on colmn and beam for steel structure conforming to ASTM D 1748-10(2015) on ramshackle girders or reinforcement encased in concrete after cleaning to loose scale or oxidized chips from bars complete all as specified and directed . NOTE:- (i) The material to be applied on the rusted metal using brush. (ii) The material shall be allowed to react for 16 to 24 hrs and afterwards all the rust shall be removed by wire brushing the surface. The surface then shell be cleaned with dry cloth before application of protective coating etc. (iii) The work will be executed in different buildings and at scattered locations. (iv) This item shall be undertaken by the authorised rep of manufacturer.
Providing and filling to cracks in RCC components after opening up in “V” groove manner covering the area of 60mm from central line of crack with the depth of 10mm complete with three components compound graded filler, E-Resins and Shear thinning agents with adjustable consistancy by varying the filler component epoxy resin based. chemicals by Engineer-in-charge. Note- (i) The work will be executed in different buildings and at scattered locations. (ii) This item shall be undertaken by the authorized rep. of manufacturer.
M&L for gunntling to RCC works in column, beams, slabs, chajja, ceiling, facia landing , balconies etc by removing/dismantling of RCC (loose concrete) including plaster and cutting of steel bar including cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick with sikatop Armatec 108 or Colusal VL of MC Bauchemie to rusted steel reinforcement after removing cleaning all rust and supply and fisng with sufficient fastners/concrete nails/welding at regular intervals welded steel wire mesh 50mmx50mm with 4mm dia steel wire as faces/drops and applying epoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sikaa. Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2 to 2.5 Kg sqcm with varying thickness from 25mm to 100mm as per requirement at site gunniting in cement mortar (1:2) (one pat of cement and two part of ghaghar sand) and plastering in cm 1:4 to a uniform surface, wherever required at any height, location and positon complete all as specified and directed. Note: (i) After placing the additional reinforcement all conrete surface shall be thorughly scrubbing with. (ii) Additional reinforced TMT bars were incorporated in work however min 20mm cement plaster in 1:4 and necessary concrete wks related to gunniting to be included in quoted rate. (iii) Gunniting at Ground floor to 4th storey (iv) Anti corrosive protective coating for reinforced bars. (v) Work to be carried out as in patches as directed by Engineer-in-Charge. (vi) Rate for steel scaffolding and formwork wherever required and as directed to be included in quoted rate. (vii) All demolished material removed from MoD land completely to any location as per NGT Norms. (viii) The work will be executed in different buildings and at scattered locations.
Demolition of Reinforced cement concrete Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (cutting of reinforcement included in the rate complete all as specified and directed. Note :- Bldg ht up to 3rd Storey and above
Separating, scraping and cleaning of reinforcement (demolition of concrete measured Separately) complete all as specified and directed.
Demolition of existing mud in roofs of any thickness including plastering and leeping (whether full thickness removed or only a part thereof) (Including 4 Story building) and removing of mud from MOD land complete all as specifed and directed.
M&L for RCC M-25 design mix in roof slab supported on wall, beam and column etc (using 20 mm graded stone aggregate) complete all as speified and as directed by Engr-in-Charge. Note :- Bldg ht up to 3rd Storey and above
M&L for Form work to soffits of suspended slab such as roof slab, floor slabs,Chhajja, landngs and similar work etc not exc 200 mm thick (horizontal or sloping), rough finished flat surfaces concrete complete all as specified and directed. Note :- Bldg ht up to 3rd Storey and above)
M&L for Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, rough finished surfaces of concrete complete all as specified and directed by Engr-in-Charge. Note :- Bldg ht up to 4th Storey and above
M&L for Form work to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed by Engr-in-Charge. Note :- Bldg ht up to 4th Storey and above
M&L Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specifed and directed by Engr-in-Charge Note :- Bldg ht up to 4th Storey and above
All as per Srl item No 23 here-in-above but 6 to 8mm dia complete all as specified and directed.
Re-baring by drilling holes and fixing nozzle if required in existing concrete/brick work as in column, beams, slabs and foundation etc in any position and any description size of hole 14mm, 16mm & 22mm suitable for dowels of size 10mm, 12mm & 16mm respectively (minimum depth 140mm for 10mm & 12 mm dia bars and 180mm for 16mm dia bar, cleaning the surface properly with blow out pump & round brushes and fixing of dowel bars with epoxy resin (resin+hardner). Make: Sika, Fosroc or concressive 1450 of BASF complete all as specified and directed by Engr-in-charge. Note:- (i) Adequate lap length shall be provided as per IS-456-2000. (ii) Reinforced TMT bars where incorporated in work will be paid under the relvent items. (iii) The work shall be carried out upto four storied building with scaffolding and in patches as directed by Engr-in-charg e. (iv) Rate for scaffolding and formwork wherever required and as directed to be included in quoted rate. (v) The works will be executed in different buildings and at scattered locations.
M&L for rendering 15 mm thick cement mortar in two layer (under layer 10 mm thick and upper layer 5 mm thick ) CM 1:4 on brick/concrete surfaces of wall, fair faces and other than fair faces mixed with water proofing compound, finished even and smooth without using extra cement, including taking down of cement plaster, complete all as specified and as directed by Engineer-in-Charge. Note:- Water proofing compound shall be measured and paid separately.
M&L for washed stone grit plaster on exterior walls in two layers under layer 12mm cement plaster 1:4 (1cement 4 coarse sand) furrowingthe under layer with scratching tool applying cement slurry @ 3kg/sqm top layer 15mm cement plaster 1:1/2:2 ( 1cement 1/2 coarse sand : 2 stone chipping coloured 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing & washing the top layer with brushes & water to expose the stone chipping including taking down of plaster complete all as speacified pattern decided by Engr-in-Charge. (payment for providing grooves shall be made separately). Note:- Top layer of shade shall be of grey cement using colouring pigment and stone chipping of desired colour as approved.
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
M&L for 15 mm thick rendering in cm(1:6) in two layers with backing coat 10 mm thick and second coat 5 mm thick on other than fare face of brick/stone/concrete surfaces and finished the surface even & smooth without using extra cement mixed with WPC (WPC Will be measured and paid seperately), including taking down of cement plaster, complete all as specified and directed by Engr-in-charge.
M&L for 5mm thick rendering in CM 1:3 on concrete surface as in ceiling finished even and smooth w/o using extra complete all as specified and directed by Engr-in-charge
M&L for applying two coat of Distemper oil emulsion by Auto Roller over a coat of primer over 2 to 3 mm thick birla putty punning including finishing by Sanding Machine and Auto Roller new surface complete all as specified or as directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of wall, and applying two coat of Oil bound distemper white or colour, over one coat of primer including wall care putty upto 2 mm thick as required (multipurpose mixer shall be used for uniform adn proper mixing of putty) by using smart periodical methodology/ auto roller, complete all as specified and directed by Engr-in-charge.
Note:- (a) The material as incorporated in the work shall be undertaken by the authorise representative of manufacturer/dealer. (b) Material will be accepted and allowed to incoporate in the work only after production of Purchase Voucher / Invoice from the manufacturer / authorised dealer in original and test certificate from the manufacturer,dealer. (c) Bidder must submit the authorised applicator certificate at the time of sample approval. The authorised applicator shall be as per Manufature list mentioned in CA. (d) The Contractor shall give Guarantee for structural repair of for a period of 10 (Ten) years from the certified date of completion. Similarly the Contractor shall take warranty of structural repair for next 10 years of the work immediately after executions/ completion of work from the authorised Applicator . (e) The quoted rate shall be inclusive of carrying out work upto 15m height of building. (f) Water is not supplied by the MES. Water will be arranged by contractor and contractor should produced all necessary Test Certificates for portable water fit for construction and rehabilation as per relevant IS. Rate of Water tanker and rate of water testing are inclusive in quoted rate. (g) All debris will be removed from MoD land as per NGT Norms. (h) The contractor should make good of any damaged and disturbed surface and clean all cement/guniting etc patch on windows/doors/and all surface.
Schedule of Credit
POOJA ENTERPRISES (BID ID -3398142)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .