| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.0 LAccepted-AOC 0 BILARI ROAD CHAURI CHAURA GORAKHPUR GORAKHPUR UTTAR PRADESH 273202 | GORAKHPUR | UTTAR PRADESH | 273202 | ₹54.0 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹55.1 LRejected-AOC GOBARDAHA TOLA GRAM MO GAUKHAHI THANA DANJA BHIKHAHI GARHWA JHARKHAND 822124 | GARHWA | GARHWA | JHARKHAND | 822124 | ₹55.1 L | L2 | Rejected-AOC L2 bidder |
| 3 | Rejected-Technical DEOGHAR DEOGHAR | DEOGHAR | JHARKHAND | 814112 | - | - | Rejected-Technical Bidder substantially not responsive due to non compliance of NIT Detailed Sl. No. 25 of F2 bid document |
Updated dates
Tender Value
₹54.0 L
EMD Value
₹1.1 L
Closing Date
21 Oct 2025, 5:00 pmClosed
Chief Engineer
Jharkhand Police Housing Corporation Limited Line Tank Road Ranchi 834001
Repair Work of C Type Residential Quarter Building G plus 2 of Fire Station at Jamtara in the district of Jamtara.
2025_JPHCL_105175_1
JPHCL/GR 29/NIT 04/2025-26
Open Tender
Civil Works
120 days
Jamtara
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.1 L
Yes
13 May 2026
27 Sept 2025
24 Oct 2025
27 Sept 2025
21 Oct 2025
27 Sept 2025
5.7.3 Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
5.7.3 Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
5.7.6 Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
5.10.7 Disrnantling old plaster and pointing in cement or lime and raking out joints to 15mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/|.
5.10.4 Dismantling patent stone floor includingstacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/|.
11.41/ D.S.R Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of Tile 600x600 mm
DSR 11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
DSR 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
DSR 10.14 Providing and fixing pressed steel door frames conforming to IS: 4351 manufactured from commercial mild steel of 1.60 mm thickness including hings , jamb , lock jamb, bead and if required angle threshold of mild steel angle od section 50x25mm or base ties of 1.60 mm pressed mild steel welded or rigidly togather by mechnical means including M.S pressed butt hiongs 2.5 mm thick with mortar guards , lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the surface as directed by Engineer - in-charge. Profile B
10.14.1 Profile B 10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb
5.5.12 Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I.
5.8.41 Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
5.8.44 Providing one coat of synthetic enamel paint of approved shade and make over steel surface -do-surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in bullding specification).
5.8.9 Extra for cleaning the old surface by scrapping the entire old white wash or colour wash rncluding cost of scaffolding all complete as per direction of E/I.
DSR 13.45.1 Finishing walls with textured exterior paint of required shade : 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
DSR 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
5.8.18 Providing two coats of oil bound distemper of approved make & shade over a coat of cement primer over new surface including preparing the plastered surface by rubbing, smooth with pumic stone or fine sand paper, aplying putty wherever required, scaffolding , washing of flores and taxes etc. all complete as per building specification direction of E/I.
DSR 22.14 Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size)
14.90 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid usin
g butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
DSR 14.92 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
DSR22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry
5.1.10 Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
5.3.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 5.3.1.1 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
5.10.33 Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of earthwok involved with 75mm cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at th base, he drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
DSR 11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
5.3.8 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth
DSR 26.87 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.1 30 mm thick
DSR 12.41.2 Providing & fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Single socketed pipes. 110mm dia
DSR 12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
DSR 9.147.D.5 Providing and fixing factory made uPVC white colour sliding glazed windowupto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
9.135/D.S.R. Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both direction with wire of dia. 0.50 mm all complete.
9.135.2 With 12 mm mild steel U beading
5.8.32 Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I
8.2/DSR Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite stone slab colour black, Cherry/Ruby red 8.2.2.2 Area of slab over 0.50 sqm
DSR 8.3 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 8.3.2 Granite work
DSR/13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
DSR 16.68 Providing and laying 60mm thick factory made Cement Co
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
ncrete Interlocking Paver Block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick complacted bed of course sand, filling the joints with coarse sand etc. all complete as per the. direction of E/I.
DSR 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fastenersetc.).
Brick (51 KM)
Coarse Sand (1k+9p= 10KM)
Stone Chips (25KM)
DSR 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
D.S.R. 18.53 Providing and fixing C.P. brass angle valve for , gyser & others points of approved quality conforming to IS 8931. 18.53.1 15mm nominal bore, approved brand C.P. fittings.
D.S.R. 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end )
DSR 18.18.3 25mm nominal bore
DSR 18.74 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 18.74.2 15 mm nominal bore with 45 cm length.
D.S.R 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
DSR 12.42.1.1 Coupler 75 mm
DSR 12.42.3 Single tee with door
DSR 12.42.2.1 75 mm
DSR 12.42.5 Bend 87.5°
DSR 12.42.4.1 75 X 75 X 75 mm
D.S.R.12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
DSR 12.43.2 110 mm
DSR 12.42.6.1 75 MM
DSR 12.42.6.2 110 MM Shoe
DSR 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I.(Approved Brand - ASTRAL/ SUPREME)
Concealed work including cutting chases and making good the wall etc..
Exposed on Wall
DSR 18.8.2. 20mm dia
DSR 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
DSR 18.7.3 25 mm nominal outer dia Pipes
DSR 19.6 Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete.
DSR 19.6.2 150 mm
dia R.C.C. pipe
D.S.R. 19.30 Constructing brick masonary chamber for Underground C. I. Inspection Chamber and bend with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. Cover with frame (light duty) 455X610 mm internal dimensions, total weight of cover with frame to be not less than 38 KG. (weight of cover 23 kg. and weight of frame 15 kg) RCC top slab with 1:1.5:3 mix (1 cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 mix (1 cement:5 coarse sand :10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm th. with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
D.S.R 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
19.30.1.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Analysed and Approved Providing and Fixing Hand Shower ( Health Faucet) ( ABS Body) ALD-CHR-585 Jaquar made. Hand Shower with 1 meter Long Easy Flex Tube in Chrome Finish & Wall Hook.
Analysed and Approved Pvc trap including all fittings
DSR/17.10.1.2 Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S.13983 with C.I. Brackets stainless steel plug 40mm including painting of fittings and brackets cutting and making goods the walls wherever required :DSR 17.10.1 Kitchen sink with drain board DSR 17.10.1.2 510x1040 mm bowl depth 225 mm
Septic tank & Soak-Pit
5.3.1.2 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size)
5.6.1 Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I
5.1.1 Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing ro
5.1.2 Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
9.5.2 20/22 W LED Batten of make bajaj/havells/crompton /C&S
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.21 Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
5.1.10 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as pe
5.2.2 Providing designation 75A brick work in C.M (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curri
5.2.23 Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out
5.7.2 Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
5.7.11 Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
JSR Page no (59) SI no(16) Item code (M-198) (Basic rate +14.95%) Brick bsts at Kiln site
Providing tor steel reinforcement TMT FE 500 of following dia. rods as per approved design and drawing including carriage of bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction and direction of E/I. (Only valid for TATA TISCON / SAIL).
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
ncrete Interlocking Paver Block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick complacted bed of course sand, filling the joints with coarse sand etc. all complete as per the. direction of E/I.
DSR 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fastenersetc.).
Brick (51 KM)
Coarse Sand (1k+9p= 10KM)
DSR 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 12.41.2 110 mm diameter
DW & SD SL NO 31(b) Page no(39) M 947 (Basic rate +14.95%) Supplying, fitting and fixing C.I. cover with frame for mane hole and inspection chamber with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of E/I. (b) Size 600 x 450 mm (Wt. 25 Kg).
Steel (5 Km)
1.3.1 Group A
INTERNAL & EXTERNAL ELCTRIFICATION WORK
1.5 Power plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
1.7 Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
1.7.1 2x1.5 sq mm+1x1.5 sq mm earth wire
Note:- OF MAKE (1)PVC insulated copper conductor wire of make:-Havell's/Polycab/Finolex/Anchor/Nitcab (2)PVC conduit of thickness 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG (3) GI modular box of make -: Anchor/ Havells/Legrand/ABB (4)Switches/scoket outlet for modular type:- Anchor(roma) / Havells(cabtree) / C&S/ Legrand (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:Havell's/L&T/Legrand/Schneider/C&S (6)XLPE/PVC aramoured cable:-Havell's/Polycab/V-guard/Finolex (7) LED FTTING FIXTURE -: Havells/Bajaj/Crompton/C&S (Model/as per E/I ) (8) CEILING / WALL / EXHAUST FAN -: Havells / Bajaj / Usha (Model/as per E/I) (9)OCTAGONAL POLE/High Mast-: Bajaj/Philips/Surya/Valmont/RR Ispat/Transrail (10) CENTRALISED AIR CONDITIONING-:VOLTAS/MITSHUBISHI/TOSHIBA/DAIKIN (11)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED (12)CCTV CAMERA /DVR-:Panasonic/Hik vision/C P Plus/Godrej (13)Monitor Camera -: Dell/Samsung/LG/Asus (14)Silent type D.G Set-:Kohler/Jakson/Sterling/Mahindra
1.3 Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
1.4 Twin control point wiring PVC conduit with modular type switch:-wiring for Twin control point with 1.5 sq mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, 2 way modular, switch, pheonlic lamineted sheet,suitable size G.I.box etc.as required.
1.7.5 2x10.0 sq mm+1x6.0 sq mm earth wire
1.7.2 2x2.5 sq mm+1x2.5 sq mm earth wire (for circuit wiring)
1.21 S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required .
1.7.8 4x2.5 sq mm+2x2.5 sq mm earth wire
1.7.4 2x6.0 sq mm+1x6.0 sq mm earth wire
1.24 S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
1.24.1 5/6 amps, one way switch
1.17 TV cable in existing conduit :- Supplying and drawing co-axial TV cable RG-6 grade copper conductor,PE insulated,with PVC sheath in the existing recessed PVC conduit as required.
1.24.7 TV socket socket outlet
1.25 S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
1.26 S/F Modular type blanking plate:-Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc, as required.
1.27 S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
1.27.1 1 or 2 module(78mm x 78mm x 45mm)
1.27.3 6 module(78mm x 205mm x 50mm)
1.32 S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required.
1.33 S/F ceiling rose:- Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
1.34 S/F Batten holder:- Supplying and fixing batten/angle holder including connection etc, as required.
1.36 S/F Dingdong Call bell :- Supplying and fixing dingdong call bell suitable for DC/AC single phase,230 volt, complete as required.
1.48 ITC exhaust fan up to 450 mm, sweep:- Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required.
2.8 S/F S.P. MCB DB:- Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
1.22 S/F PVC/G.I. boxes :- Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc as required .
2.11 S/F 'B' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2.11.1 6/32 amps,single pole, "B" SERIES
2.12 S/F 'C' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2.12.1 6/32 amps,single pole, "C" SERIES
1.22.1 75mm x 75mm x 50mm deep/ (4" x 4")
2.12.7 50/63 amps, DP
1.24.4 5/6 amps, 3 pin socket outlet
3.6 Copper Earth plate electrode:- Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.( with salt charcoal or coke)
3.7 S/L 8 SWG copper wire ground :- Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
2.8.8 8 Way,Double door
2.12.6 40 amps ,DP
3.2 G.I Earth pipe electrode with salt charcoal :- Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke.
4.2 P/F G.I. lightning conductor finial:- Providing and fixing of lighting cnductor finial, made of 25 mm dia 300mm long, copper tube having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required.
4.4 Reverting, sweating and soldering of copper/G.I. tape(with another coppr/G.I. tape, base of the finial or any other metallic object) as required.
5.1 Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
5.2 Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 35 sq.mm.but not exceeding 95sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
4.7 P/F G.I. lightning conductor tape in horizontal run:- Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(For horizontal run)
4.8 P/F G.I lightning conductor tape in vertical run:- Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(for vertical run)
4.12 P/F Testing joint for G.I. lighting conductor:- Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long, with 4 nos.of G.I. bolts, nuts, chek nuts and spring washers etc complete as required.
9.1 DSR Supplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
Supply of PVC XLPE insuletd PVC sheat
hed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g
M-326 25 sq.mm. 3.5 core
M-328 50 sq.mm. 3.5 core
9.4 S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
9.4.1 1200 mm (48") Ceiling Fan of make bajaj/havells/usha/crompton/polar
9.1.20 DSR 3½ X 25 sq. mm (28mm)
9.1.22 DSR 3½ X 50 sq. mm (35mm)
9.5 SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
9.1 SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
12.37 DSR Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
M - 775 Providing of 12'' (300 mm)exhaust fan of make bajaj/havells/usha/crompton
M 856 Supplying and fixing of LED/15/16 W of make bajaj/havells/crompton
M-869 Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
MAIN PANEL
LT PANEL (NORMAL SUPPLY) :35 KA) -INCOMING (1- sets ) each with following:
(A)INCOMING
1.22.1 75mm x 75mm x 50mm deep/ (4" x 4")
2.12.7 50/63 amps, DP
M - 318 4 pole MCCB,25/100amp,10 KA with fixed thermal magnetic setting
M - 304 100 amp. fout pole, onload change over switch in sheet enclosure with side handle oDeration
M-617 100 amp,415V, Heavy duty three phase with neutral Busbar Chamber
(B)OUTGOING
(C)OTHER ACCESSOSRIES
M- 873 A DIGITAL VOLT METER 500V(3phase class 0.5)
M- 873 B DIGITAL A METER 500V(3phase class 0.5)
M- 445 COPPER WIRE 1.5MM
M- 448 COPPER WIRE 6MM
Add 18% GST
Add 1% Lebour Cess
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
BOQ_141545.xls
BOQ • 0.43 MB
Techbid29.pdf
Tender Documents • 7.05 MB
Download all tender documents and submit your bid