Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹12.7 L+₹77,664 (6.53%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-AOC Not Lowest |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
13 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
GE Bharatpur
Repair Maintenance of MES Installation at RMS Dholpur
2021_MES_422836_1
8017/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Bharatpur
Class E category a(I) b(I)
7 documents required · 7 mandatory
₹500
Yes
GE Bharatpur
₹26,000
Yes
17 May 2021
16 Feb 2021
15 Mar 2021
16 Feb 2021
13 Mar 2021
28 Feb 2021
60 days
Amount
Taking down carefully old UNSV glow sign board after removing electrical connections, electrical fittings etc., any type and size with out damaging any structure and making good as per existing if structure damaged etc complete all specified and ad directed
Taking down/pulling out of old UNSV LT pole of any size and type from site after disconnecting all kind of connections and disposing out of site, filling up of old holes as per existing complete all specified and ad directed
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete fittings such as switches, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of wall, floor & ceiling etc complete all specified and ad directed
Taking down old U/S rusted main switch/DB of any size capacity and make complete all specified and ad directed
Taking down old U/S sub main wiring of any size & make complete all specified and ad directed
Taking down old U/S digital controllers from existing Auto Transfer Switch of any size and capacity complete all specified and ad directed
Taking down old ACSR conductor 4 runs from the insulators fitted on LT poles of any size, dismantling of UNSV channels/cross arms etc without damaging any assets esisting near the well no 1 at Gundrai forest complete all specified and ad directed
M&L for dismantling of old UNSV DG set 63KVA installed at Gundrai pump house of any type and capacity from its foundation after removing all kind of cable connections, mounting etc by using crane which is installed at Gundrai pump house (old installation room), pulling out properly and carefully with all kind maximum safety level without damaging the existing structure, wall or any floor etc, making good as per existing postion if damaged, transportng to E/M store yard loacted at Kesarbagh by hiring suitable truck -, including demolition of undulant mounting PCC platform equal to the floor level and plastering with suitable bonding materials with extreme well finish as per the old complete all specified and ad directed
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying LT UG cable, Stay wire and LT pole etc and getting out in hard/disintegrated layer complete all specified and ad directed
Removing excavated soil at a distance not exc 50 m and deposited where directed complete all specified and ad directed
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all specified and ad directed
Supply & laying sub class B bricks, locally available un-burnt bricks suitable for LT cable protection cover complete all specified and ad directed
M &L local river sand for bedding ang sand cushioning of all LT UG cable complete all specified and ad directed
M&L for PCC (1:2:4) type B2 with using 40mm graded aggregate as in foundation and mass filling concrete for LT panel boards and in addition where ever complete all specified and ad directed
Supply, laying and testing cable XLPE insulated,screened, PVC bedded, galvanised steel strip or wire armoured,electric power cable (heavy duty) with stranded aluminium conductor 1100V grade , 3 1/2 core of size 95 Sqmm complete all specified and ad directed . Make: Polycab/Havells/Gloster
M&L for loose filling / hardcore packing of stone aggregates of guage n.exc 63mm boulders in switch yard for arresting fire and arc , upto thickness n.exc 15cm, complete all specified and ad directed
M&L stay wire complete length 7/4.0mm Grade 2 with securing and clamping on stay assembly complete all specified and ad directed
M&L stay assembly complete set of size 16mm rod with accessories as shown electrical plate no.1, incl loop type insulator stay clamp etc complete all specified and ad directed
S&F Anti climbing devices, comprising 2.24mm dia galvanised steel 2 strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 mtr clamped and properly secured or as ordered all as specified and as directed by Engineer-in-Charge.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and conventional skull and bones in singnal red colour and fixed with MS clamps, bolts and nuts of approved size of 25x20cm complete all specified and ad directed
M&L for GI guard wire 4mm dia including making cradles etc over the bldg and road crossings/nalah crossings from Kesarbagh to Gundrai OH line etc complete all specified and ad directed
Supply and errect steel tubular swaged pole 11mtr high at Gundrai pump house, with finial tapper, to arrange 2 pole structure at an average distance pole to pole not less than 3 mtr, comprising CI base plate, type 410 SP-55, including nuts, bolts, washers etc complete all specified and ad directed
M&L for cross arms C shaped or angle type as per site requirement, bracings, supports, clamps and back plates etc fabricated from structural steel section incl nuts bolts and washers, welding, bending, cold or hot, drilling holes for bolts, in any shape and any length fto fix on two pole structure or any single pole at any height and any location as per site reqiuirement complete all specified and ad directed
M&L for stringing ACSR conductor on poles 3 runs of wiesel and 3 runs of squirrel or as per site requirement with permissible sag as per IS rules etc complete all specified and ad directed
M&L for painting aluminium coat over Steel tubular pole and cross arms any size and height including preparration of metallic surface with sand papers and applying one coat of metallic primer before applying aluminium paint all as specified and as directed by Engineer-in-Charge. Make of paint: Berger/Asian Paints. Note: Location - Gundrai area. During school hours Shutdown shall be given after getting approval from the Stn I/C oficer and during holidays shutdown shall be given after consulting with Engineer-in-Charge. Continuous shutdown more than 4Hrs shall not be given in a single day because of water supply constraints. All kind of safety deivces, vehicles and ladders shall be arranged by the contractor at site complete all specified and ad directed
S&F glow sign board of white polished transparent acrylic cover of minimum 2mm thick, unbreakable, heat resistive etc including M&L of steel fabrication of angles and supports of thickness not less than 2mm thick (thickness shall be variable upto 5mm as per site conditions) rectangular box type of size minimum 180cm x 90cm x 20cm thick, computerised letter of blue colour of size 30cm high and 3 to 5cm width or small as per site requirement having glue on backside to stick permanently, including all kind of securing, welding, assembling with proper allignment and height with fine look, including PCC, cement work, excavation if required, LED tube light fittings 1x 20Watt, including connecting wires and switch independent one way 5Amp with well finish of weather proof suitable for exposing at all weathers complete all specified and ad directed
S&F glow sign board of white polished transparent acrylic cover of minimum 2mm thick, unbreakable, heat resistive etc including M&L of steel fabrication of angles and supports of thickness not less than 2mm thick (thickness shall be variable upto 5mm as per site conditions) rectangular box type of size minimum 400cm x 60cm x 20cm thick, computerised letter of blue colour of size 30cm high and 3 to 5cm width or small as per site requirement having glue on backside to stick permanently, including all kind of securing, welding, assembling with proper allignment and height with fine look, PCC, cement work, excavation if required, LED tube light fittings 1x 20Watt, including connecting wires and switch independent one way 5Amp with well finish of weather proof suitable for exposing at all weathers complete all specified and ad directed
M&L for levelling and cleaning of unwanted thorny bushes grown around the water supply installaitons at Gundrai pump house and filling up of undulant portions by using rough excavated soil with the help of manpower or dozer/JCB etc and removing all kind of debris/bushes min 150mtr away from the compound wall without damaging cables, pipeline and other existing structures etc complete all specified and ad directed
S&F in replacement LED street light fittings with excellent thermal management of 90 Watt Ip-65 with complete accessories on existing brackets fixed on MES installation bldgs at Gundrai and Kesarbagh palace including taking down the old UNSV one and connecting up the lights to the nearest point by using 1sqmm copper wire 2 run and replacing the brackets and clamps if required , drilling holes on stone masonry all as specified and as directed . Make Havells, Cat part No LHETBXU7PN6J090
M&L point wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in and including PVC casing and caping double locked box type with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly complete all as specified and directed for the following :- (a) One light point controlled by one way switch.
(b) One fan point controlled by one way switch.
(d) One 3 pin 6 Amp socket point outlet on the same board with other switches
(e) One 3 pin 6 Amp socket point outlet on the independent board
All as per item No 30 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps socket point outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified and as directed.
S&F socket outlet 2 in 1, 5pin, 6 Amps multi purpose flush type 230 volt Make : Anchor code No 95015 penta or equivelent in Legrand complete all as specified and as directed.
S&F switch socket combination 2 in 1, 16 Amp flush type multi purpose 230 volt make : Anchor code No 4282 penta or equivelent in Legrand complete all as specified and as directed.
S&F switch piano flush button single pole one way 6 Amps 230 volt grade Make : Anchor Code No 95111 Penta or equivelent in Legrand complete all as specified and as directed.
S&F ceiling rose surface bakelite 50 x 40 mm three terminal ISI marked including suitable size of PVC board make : Anchor code No 3290 penta or equivelent in Legrand complete all as specified and as directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required complete all as specified and as directed.
M&L submain wiring complete with 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC casing capping PVC conduit/sleeves with all PVC accessories fixed on wall, floor/ceiling etc complete all as specified and as directed.
Distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt of the following DBs :-Makes -L & T / Legrand complete all as specified and as directed. (a) 8 way SPN with200 Amp rated busbar 240 volts (double door type).
(b) 4 Way SPN with 200Amp rated busbar 240V (Double door type)
S&F MCB 240 volts 10 KA, rupturing capacity fixed in DB's of the undermentioned type and rating. Make : L&T/ Legrand. (a) MCB SP 240 volts 10-40 Amps
(b) MCB SPN 240 volts, 40 Amps
S & F Photon Ultra LED glass crystal tube rod 20 Watt suitable for easy replacement and refixing of old frames 1200mm long with G-13 lamp holder T5 and T8 , housing finished in white powder coating complete with all accessariesall as specified and as directed .Make - Surya/Phillips or Havells Cat part No-CRYSTAL1213T8DSTL20WLED865SGLASS.
S&F tube light frame slim type suitable for replacing 1200m length LED tube rod, prewired with complete accessories suitable for fixing on wall/ceiling complete all as specified and as directed . Make - Havells Cat Part No REGALBATTENT8UPTO1X22WSSBSWH or equivalent in Phillips/Bajaj/CG
M&L batten/angle holder insulated with back plate including suitable size of PVC round block make Anchor code No 51205 (a) MCB SP 240 volts 10-40 Amps
S&F LED bulb 14 Watt or 15 Watt cool day light , in-built voltage surge protection > 3.5kV, single ph, 230V, luminous efficacy 100Lm/Watt, base B22, 5 star rated all as specified and as directed by Engineer-in-Charge. Make - Havells/CG or equivalent in Phillips/Havells.
S&F LED light fitting 1 x 10 W 230 volts bulk head energy saving luminaries with LED Bulbs etc complete with all accessories duly prewied and including connecting up with twin core twisted flexible copper conductor cable of suitable size 230 volts 50 Hz suitable for fixing on wall/surface mounted all as directed by Engineer-in- Charge. Make -Havells, CAT Part No RUGBYNEONFT10WLED86CSSYMTOPC or equivalent in Bajaj/Phillips.
M&L earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel all as showin in electrical plate No 3 connected to earthing test point all as specified or indicated (excavation, return refilling and removal of excavated soil shall be measured and paid separately) and testing on completion etc all as specified and as directed by Engineer-in-Charge.
S&F in replacement of pre programmed controller suitable for 160Amp to 200Amp capacity Auto Tramsfer Switch, digital type display with prewired jack, NO/NC terminals, suitable to fix into existing make of Havells/ABB all as specified and as directed by Engineer-in-Charge.
Demolition of brick work or stone/bolder masonary, built in cement mortar including all quions, arches, pillars,etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed.
Dismantling wrought iron or Mild steel work as in wind tie, grill grating etc, complete all as specified and as directed.
Dismantling structural steel work including doors,gates but excluding framed truss etc complete all as specified and as directed.
M&L Brick work with sub- class 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1: 4 all as specified and directed.
M&L for stone walling of random rubble, uncoursed well bonded bedded, and solidily hearted, built in cement mortar 1:6 complete all as specified and as directed.
M&L for stone walling of random rubble, uncoursed well bonded bedded, and solidily hearted, built in cement mortar 1:6 but except stone complete all as specified and as directed.
Extra over stone walling for hammer dressing to face stones and dressing,of face beds and joints, as specified, of random rubble walling uncoursed or brought up to courses with maximum depression on face from straight edge held against the dressed surface n. exc. 40 mm, on lime or sand stones complete all as specified and as directed.
M&L for Flush pointing to Random rubble masonry, uncoursed or brought up to courses in cement mortar 1:4 complete all as specified and as directed.
M&L for plain cement concrete type B1 1:2:4 (20 mm graded aggregate) as in lintels upto 1.5 m clear sp and other similar bands, plinth courses, string courses,parapets and railings upto 60 cm in height, copings, kneelers, apex stones bed plates, water troughs and the like including weathering, slightly rounded or chamfered anglesand throating, complete all as specified and as directed.
M&L for taking down cenment plaster of any description including racking out joints, hacking for kay scrubing down with water etc complete all as specified and as directed.
Raking out joint of pointing to random rubble or polygonal rubble, un-coursed or brought up to courses built in cement mortar complete all as specified and as directed.
M&L for rendering 15 mm thick on stone masonary surfaces or surfaces other than fair face of brick work or on one side of lathing in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brick work of walls, finished fair & even on edges/ Chajjas/Roof projection and simlar courses etc. complete all as specified and as directed.
M&L for Two coats of white wash on new plastered or unplastered surfaces of walls including prepration of surfaces complete all as specified and as directed.
M&L for two coats of cement base paint on new surfaces of walls, white or tionted including preparation of surfaces complete all as specified and as directed.
M&L for One coats of white wash on old plastered or unplastered surfaces of walls including prepration of surfaces complete all as specified and as directed.
Description all as per Srl item No 67 above but on ceiling complete all as specified and as directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, J hooks, washers including all fixing accessories, complete all as specified and as directed.
S&F Fibre glass reinforced translucent corrugated sheeting 2mm thick with two corrugations side lap fixed in roof, wall fixed with L-type or J-type or cranked hook bolts in lieu of screw complete all as specified and as directed.
S&F in Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work confirming to Fe-290 Gde-E-165 complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level ) and removing unserviceable material exc 100 mtr complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc complete all as specified and as directed.
M&L for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded aggregate as in sub base of floor complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 for laying other floor finishes complete all as specified and as directed.
M&L for 40 mm thick Rough dressed sand stone slab flooring, bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3 complete all as specified and as directed.
M&L for 40 mm thick Rough dressed sand stone slab flooring, bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3. except stone complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidating complete all as specified and as directed.
M&L for Machine pressed precast concrete interlocking paver block with gray cement and no pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade all as specified and directed
M&L for Machine pressed precast concrete interlocking paver block with gray cement and pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm stone aggregated as in floor finished fair and even complete all as specified and as directed.
Non skid coloured ceramic tiles area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 sqm (300x300) 6 to 7 mm thick joint less in floor/skirting set in neat cement slurry and pointed with coloured/white cement to match the surface over 20mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
M & L Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface over 10 mm thick cement mortar 1:4 complete all as specified and as directed.
Taking down chowkhats or frames not exc. 1.5 sqm each with shutters (without taking off shutters from the frames) and removing to store complete all as specified and as directed.
Taking down chowkhats or frames exc. 1.5 sq. m but not exc 4 sqm each with shutters (without taking off shutters from the frames) and removing to store complete all as specified and as directed.
S&F Material and labour for Anodised aluminum frame/grill for doors, windows ventilators with one or more rebates inculding joining cleat, aluminium snap beading for fixing, including powder Coating (minimum thickness of powder coating 50 micron), complete all as specified and directed
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws including powder Coating (minimum thickness of powder coating 50 micron),etc. complete all as specified and as directed.Note : tinted glass shall be measured and paid for separately
S&F factory made solid panel PVC door shutters 30 mm thick (style) consisting of fram made out of MS tubes for top & bottom rails. MS fram shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS fram welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, suppling & fixing in the fram at site as per specification & drawing complete all as specified and as directed.
S&F PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS squar tube , fixing in opening as per spesification & drawing complete all as specified and as directed.
S&F 2 nd class hardwood 35 mm thk glazed and skelton shutters, open rebated and prepare to receive glass, gauze,etc divided into squares with plain,chamfered or rounded,mitered and rebate sash bars, any number,edges of sash bars and framing moulded, fittted with cut and mitred beads for securing glass etc sizes of members of shutter as specified in SSR part-I section 8,clause 8.24(a) and fitted to chowkats complete all as specified and as directed.
M&L 35 mm thick 2nd class hard wood plain framed panelled shutter of factory made with lock rail and panel of 12 mm thick veneered particle board with commercial vace veneering on both faces including wooden beads on both sides, one coat of pink primer. The size of rail and stile as per IS-1003 part-I kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified and as directed.
M&L pressed steel frame 105x60mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plate including PCC 1:3:6 type C1 as in back filling etc complete all as specified and as directed.
S & F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F butt hinges medium grade cold rolled 100 mm mild steel and fixed complete all as specified and as directed.
S&F 150 mm long Aluminium anodised, berrel tower bolts of extruded section complete all as specified and as directed.
S&F 150 mm long aluminium handles, cast type, anodised complete all as specified and as directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
M&L for preparing surfaces of any description over 10 cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of Red oxide on new surfaces of steel or iron complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
S&F 3.00mm thick sheet glass ordinary quality and glazing with oil putty in square n'exc 0.5 sqm in each pane complete all as specified and as directed.
S&F 5.5mm thick sheet glass ordinary quality and glazing with oil putty/Metal clip in square exc 0.5 sqm in each pane acomplete all as specified and as directed.
M & L for preparation of new wood or wood based surface and applying two coats of synthetic enamel paint complete all as specified and as directed.
S&F galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
S&F in repair galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples, including taking down the old wire cloth complete all as specified and directed.
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed.
M & L PCC 1:3:6 Type C 2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
S&F Mild steel work as in hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, noising to steps including embeding in concrete and screwing etc wind ties for roof including securingm bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc, and similar work confirming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other , or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc15cm but n. exc. 10 cm long. Dia of neck 5 to 10 mm complete all as specified and as directed.
S&F chain link MS galvanised fencing 4mm Dia 50mm X 50mm mesh including line wire, fixed to angle iron fencing post all as specified and directed
M&L Cement concrete type C1 1:3:6 (20mm graded aggregate) in surface channels and drains all as specified and directed
M&L PCC 1:3:6 type C-1, 50 mm thick using 20mm graded stone aggregate as in plinth protections complete all as specified and as directed.
M&L for one coats painting with synthetic enamel paint to old steel or steel based surfaces of any description, not otherwise described over 10 CM width or girth including preparation of surface including all preparatory work complete all as specified Make NEROLAC /DULUX/ BERGER
M&L for one coats painting with synthetic enamel paint to old wood or wood based surfaces of any description, not otherwise described over 10 CM width or girth including preparation of surface including all preparatory work complete all as specified Make NEROLAC /DULUX/ BERGER
S&F as in repair vitreous china squatting pan (Orissa pattern) water closet (white) size 580mmx440mm with integral foot rests (excluding flushing cistern and flush pipe) complete including connection to trap and flushing pipe antisyphonage pipe etc including provision of PCC (1:7:12) type F2 in filling complete all as specified and as directed. Make : M/S Hindustan sanitary ware and Industries Ltd / M/S EID Parry (India)/Cera/M/S Johnson, H & R India Ltd/Parry ware
S&F in repair Bib taps, cast copper alloy Chromium plated with crutch or butterfly handle, screwed for iron pipe of 15 mm bore or for brass ferrule and fixed complete all as specified and as directed.
S&F in repair Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed of 15 mm bore complete all as specified and as directed.
S&F in repair 15 mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in replacement rotational moulded plyethylene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified including locking arrangement for cover using MS flat 25x3mm and necessory fittings complete all as specified and as directed.
S&F in repair vitreous china wash basin white, ovel type or flat back of size 580x 450mm including 32mm dia PVC waste pipe CP brass wast coupling 32 mm dia , pair of MS angle brackets or MS fastener/ bolts for fixing arrangements 450mm long pvc connection with PVC nut and washer complete at site and all as directed by Engr-in- charge.
S&F in repairs 10 Ltrs PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
S&F in repair PVC connection 15 mm size with PTMT nuts of length 450mm complete all as specified and as directed.
Roughning surfaces of old concrete floor by picking , sweeping , clean and washing down with water to remove dust etc including brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified and as directed.
M&L for cutting grooves in stone walls 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M&L for providing PCC (1:2:4) type B-0 12.5 mm graded stone aggregate as in roof kerbs rounded or chamfered on edges complete all as specified and as directed.
Rendering 15 mm thick in cement mortar 1:4 as on roof slabs, finished even and fair mixed with water proofing compound.(For water proofing treatment over roofs) complete all as specified and as directed. Note : - Water proofing compound shall be measured and paid for separately.
M&L APP based polymeric membrane not less than 3mm thick , weighing not less than 3.5 Kg / sqm , and upper side of membrane thermally insulated with white mineral gravel finish , informly embedded during manufacturing process,shall only be used . Itshall be laid by torch application .Side over laps shall be 75 mm and the end shall be 100 mm and all overlaps and joints shall be sealed by torch application including applying a coat of cold applied bitumen primer conferming IS:3384 @0.40 Kg/Sqm including taking down ol membrane complete all as specified and as directed.
Supply only water proofing compound ISI marked complete all as specified and as directed.
PD GUPTA AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .