Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L1 | Accepted-AOC tenderaccepted | |
| 2 | L2₹12.0 L+₹1,180 (0.10%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹12.5 L+₹55,367 (4.62%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹14.2 L+₹2.2 L (18.7%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹14.9 L+₹2.9 L (24.1%)Rejected-Finance 0 MADHUPUR SAKARDAHA MADHUPUR SAKARDAHA SARAON MADHUPUR SAKARDAHA ALLAHABAD UTTAR PRADESH 212502 | PRAYAGRAJ | UTTAR PRADESH | 212502 | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
30 Oct 2020, 6:00 pmClosed
GE faizabad
GE MES faizabad
REPAIR MAINTENANCE OF POWER FACTOR CORRECTION PANELS CAPACITOR BANKS LIGHTNING CONDUCTORS AND CONNECTED WORKS UNDER AGE EM AT GE FAIZABAD
2020_MES_378407_1
8119/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
faizabad
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Faizabad
₹40,000
Yes
23 Nov 2020
17 Sept 2020
31 Oct 2020
17 Sept 2020
30 Oct 2020
8 Oct 2020
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soft/ loose of soil complete all as specified.
M & L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness only shall be measured & Paid .
Supply & Laying of sub class 'B' bricks locally available best quality laid flat (length of bricks laid across the length of cable) in trenches for protection of U/G cable complete all as specified and directed by Engr-in-Charge.
Supplying, laying, commissioning & testing LT underground cable 16 Sqmm 4 Core, 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type etc. including taking out unserviceable LT UG cable, complete all as specified and directed by Engr-in-Charge. (Excavation and earthwork shall be measured and paid separately)
All as item no 6 but size of cable 25 Sqmm 3. 5 Core
All as item no 6 but size of cable 70 Sqmm 3.5 core.
All as item no 6 but size of cable 120 Sqmm 3. 5 Core.
All as item no 6 but size of cable 185 Sqmm 3. 5 Core.
Material and labour for control relay MXO 4OE (4 NO) (Auxilary Contactor) for automatic power factor correction panel including taking out of old one, complete all as specified and directed. . Make :- L&T/ ABB/ seimens/ Schneider.
Material and labour for ultra heavy duty Capacitors Cylindrical Series of capacity 50 kVAR three phase suitable for 440 volt AC 50 Hz supply, including taking out of old one complete all as specified and directed. Make :- L&T/ ABB/ seimens/ Schneider.
Material and labour for ultra heavy duty Capacitors Cylindrical Series of capacity 25 kVAR three phase suitable for 440 volt AC 50 Hz supply, including taking out of old one complete all as specified and directed. . Make :- L&T/ ABB/ seimens/ Schneider.
Material and labour for ultra heavy duty Capacitors Cylindrical Series of capacity 10 kVAR three phase suitable for 440 volt AC 50 Hz supply, including taking out of old one complete all as specified and directed. Make L&T/ ABB/seimens/ Schneider.
Material and labour for ultra heavy duty Capacitors Cylindrical Series of capacity 5 kVAR three phase suitable for 440 volt AC 50 Hz supply, including taking out of old one complete all as specified and directed. Make L&T/ ABB/ seimens/ Schneider.
Material and labour for LED phase Indicator lamp Red/Yellow 16 mm panel mounting type, including taking out of old one complete all as specified and directed.
Material and labour for LED phase Indicator lamp Blue 16 mm panel mounting type, including taking out of old one complete all as specified and directed.
Material and labour for Push Button Red/ Green panel mounting type, including taking out of old one complete all as specified and directed.
S & F MCB 415 V, triple pole, 63 Amps, 'C' curve, 10 kA including taking out of old one complete all as specified and directed.
S & F MCB 415 V, triple pole, 32 Amps, 'C' curve, 10 kA ,including taking out of old one complete all as specified and directed.
S & F MCB 415 V, triple pole, 16 Amps, 'C' curve, 10 kA including taking out of old one complete all as specified and directed.
Supply & fix in replacement of MCCB, 4 pole, 125 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T / C&S / Schneider.)
Supply & fix in replacement of MCCB, 4 pole, 160 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T / C&S / Schneider.)
Supply & fix in replacement of MCCB, 4 pole, 200 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T / C&S / Schneider.)
Supply & fix in replacement of MCCB, 4 pole, 250 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T / C&S / Schneider.)
Supply & fix in replacement of MCCB, 4 pole, 320 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T / C&S / Schneider.)
Supply & fix in replacement of MCCB, 4 pole, 500 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T / C&S / Schneider.)
S & F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 60 kVAR, including taking out of old one complete all as specified and directed. Make L&T/ ABB/ seimens / Schneider.
S & F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 30 kVAR, including taking out of old one complete all as specified and directed. Make L&T/ ABB/ seimens / Schneider.
S & F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 12.5 kVAR including taking out of old one all as specified and as directed.Make L&T/ ABB/ seimens / Schneider.
S & F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 8.5 kVAR,including taking out of old one complete all as specified and directed. Make L&T/ ABB/ seimens / Schneider.
S & F three phase digital Voltmeter with LED display, accuracy class 1.0, voltage measurement range between phase to phase 50-550 volt AC flush mounting type of size 96 x 96 mm of including taking out of old one complete all as specified and directed.
S & F three phase digital Ammeter with LED display, accuracy class 1.0, AC flush mounting type of size 96 x 96 mm of including taking out of old one complete all as specified and directed.
S & F Current Transformer tape wound ring of capacity 200/5 Amp, burden 15 VA, precision class 1% including taking out of old one complete all as specified and directed.
S & F Current Transformer tape wound ring of capacity 400/5 Amp, burden 15 VA, precision class 1% including taking out of old complete all as specified and directed.(Make- L&T/Kappa/Matrix ).
S & F Current Transformer tape wound ring of capacity 500/5 Amp, burden 15 VA, precision class 1% including taking out of old one complete all as specified and directed. (Make- Kappa/ L&T/Matrix ).
S & F APFC replay of step (5 +1*) of size 96 x 96 (3 Step APFC controller + 3 step plug-in-module) complete all as specified and directed. (Make- L&T / Schneider/Simens).
S & F APFC replay of step (7 +1*) of size 96 x 96 (5 Step APFC controller + 3 step plug-in-module) complete all as specified and directed.(Make- L&T, /Schneider/Simens).
S & F APFC replay of step (13 +1*) of size 144 x144 (8 Step APFC controller + 3 step plug-in-module + 3 step plug-in-module) complete all as specified and directed.. (Make- L&T / Schneider/Simens).
S & F multi step switch with OFF of capacity 1 phase 3 Watt, 6 Ampcomplete all as specified and directed.
M&L Shifting of Capacitor Panel/LT Panel after Disconnecting all the electric connections from and earthing terminals from the LT Panel including fixing to another bay with new foundation and necessary earthwork all as directed by Engr-in-Charge including transporting to another place as directed and providing material as required for proper testing of panel.
Khan Brothers
Aey Key Enterprises
M/s A.KUMAR ELECTRICALS
Avion Industries
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .