Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC 1814 NARSING NAGAR RANJHI JABALPUR MP 482005 | JABALPUR | JABALPUR | MADHYA PRADESH | 482005 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹33.4 L+₹70,065.56 (2.15%)Rejected-Finance PLOT NO 12 SAKAR GRAH NIRMAN SOCIETY TILHARI MANDLA ROAD JABALPUR MP 482001 | JABALPUR | JABALPUR | MP | 482001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹34.9 L+₹2.3 L (6.97%)Rejected-Finance 116 JAI BHEEM NAGAR POLIPATHAR GWARIGHAT ROAD JABALPUR MP 482008 | JABALPUR | MADHYA PRADESH | 482008 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹35.7 L+₹3.1 L (9.39%)Rejected-Finance 114 BARH CHONDI BARH PATNA BIHAR 803213 | PATNA | PATNA | BIHAR | 803213 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹36.6 L+₹3.9 L (11.9%)Rejected-Finance HOUSE NO 70 SAGE HARITAGE PHASE 1 BAWARIYA KALAN BHOPAL MP 462026 | BHOPAL | MADHYA PRADESH | 462026 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹41.0 L
EMD Value
₹82,060
Closing Date
28 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
PROVN OF SAFETY WALL AT FIRING RANGE OF JAK RRC AND CERTAIN MINOR WORKS IN THE AREA OF AGE B/R-II (W) AND AGE E/M (W) E/S UNDER GE (WEST) JABALPUR
2024_MES_672108_1
8783/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹82,060
5 Dec 2024
5 Sept 2024
30 Sept 2024
5 Sept 2024
28 Sept 2024
14 Sept 2024
5 Sept 2024 - 7 Sept 2024
Amount
Excavating over areas for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. exc 10 sqm on plan area and not exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
Excavating over areas exc 1.5m but not exc 3M in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. exc 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.
M&L for RCC design mix M-25 using 20mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles complete all as specified and as directed.
M&L for Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
M&L for RCC design mix M-25 using 20mm graded stone aggregate in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
M&L for RCC design mix M-25 using 20mm graded stone aggregate as in lintel beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for fly ash brick work built in cm (1:6) of compressive strength not less than 75 Kg/Sqcm straight or curved on plan exceeding 6 mtr mean radius complete all as specified and as directed.
M&L for Rendering 15 mm thick on brick work or concrete surface in CM 1:4 with water proofing compound finished fair& even surface complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
M&L for TMT reinforcement bars 10mm over dia including all cutting, bending, binding, cranking, placing & binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and asdirected.
M&L for TMT reinforcement bars 6 to 8mm dia including all cutting, bending, binding, cranking, placing & binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and asdirected.
M&L for TMT reinforcement bars 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material exc. 50 m and n exc 250 m depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
M&L for prepration of newly plastered surfaces of walls and applying two coats of cement paint over a coat of alkali resistant primer paint complete all as specified and directed.
M&L Moorum/red bajari filling in floor or paving, laid in layers n.exc 15cm thick,spread levelled and rammed including watering complete all as specified and directed.
M&L for providing Reinforced cement concrete of M-25 (Design Mix) (using 20mm graded stone agg) for landings, chajjas, and similar articles with plain faces etc. with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match the shade set in CM 1:4 including necessary form work complete all as specified and as directed.
S&F in repair mild steel, Fe 410-W (Gde E- 250 quality-A) Framed work as in doors or gates,roof structure of any size and section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging;as in gate including all necessary fitting, also fastening and fixing,including dismantling, complete all as specified and as directed.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug , bolts, nuts & screws complete all as specified, type 410 SP - 55 of 11 mtr long including painting of pole with one coat red oxide primer & two coat of aluminum paint & embedded portion of pole shall be painted with two coat of black paint complete all as specified and as directed.
Supply, fixing and connecting,along with bracket of suitable size to fixing on LT pole, energy saving and environmental friendly long life LED street light 70 Watt, made up of pressure die cast aluminium 100 housing with high efficiency LED as lighting source with separate driver compartment with IP-66 protection and powered by integral, isolated electronic LED driver. The Luminaire shall conform to following technical specifications: (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD= max upto 10 % (iv) CRI = minimum 70 (v) Surge Protection upto 10 KV with in-built SPD (vi) Lumen efficacy of LED >140 lm/W and lumen efficacy of system = min 7000 lm
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4.0 core complete all as specified and as directed.
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed ( Note : Punned thickness shall be measured for payment).
Supply and laying modular bricks covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and as directed.
Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main Aluminium bus bars of 630 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complete and including the followings :
CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables. INCOMING :- MCCB 200 Amps, 4 pole, 415 volts, 36 kA, 50 Hz, electronic release - 01 Nos OUTGOING : (a) MCCB 63 Amps, 415 volts, 25 KA, 50 Hz, thermal magnetic release, Ics = 100%Icu, - 03 Nos (b) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos (c) Digital Ammeter 96mm x 96mm suitable to read 0 to 200 Amps, accuracy class 1% - 01 Nos
(d) Current transformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos (e) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (f) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (g) Danger Notice Plate -02 Nos (h) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.- 01 Nos (j) Time switch microrex analog time switch -01 Nos (k) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe upto 7.5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply & fix aluminium strps 25x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed .
S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw , drolled , cutting upper & lower portion for incoming & outgoing including double insulators over two coats of synthic enamel paint complete all as specified and as directed .
Supply and fix air termination rod single pointed aluminium rod of 12 mm dia and 300 mm long complete all as specified and as directed.
Supply and errect vertically Galvanised, steel rod 16mm diameter and 2.5 metres length complete with fittings for raising height for air termination rodscomplete all as specified and as directed.
Supply & fix Galvanised iron strip 32 x 6mm buried in ground strps with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) including Demolition of road/path /concrete as in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Earthing complete with galvanised steel earth plate 60×60cm ×3.15mm thick electrode earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32×6mm by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), cast iron frame, funnel with wire mesh,GI watering pipe of 20 mm bore medium grade and lugs, with and including galvanised iron strip 32×6mm with GI protection pipe of 15 mm medium grade 7.5 meter long, etc complete all as specified and as directed.
upadhyay Builders (BID ID -3104414)
chandra builders (BID ID -3100771)
MAA SHARDA CONSTRUCTION (BID ID -3104751)
RAGHAVAY CORPORATION (BID ID -3104607)
SHRI KRISHNA CONSTRUCTIONS (BID ID -3100138)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .