| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹24.0 L+₹3.2 L (15.6%)Rejected-Finance 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L2 | Rejected-Finance Higher than L1 bidder | |
| 3 | L3₹25.9 L+₹5.2 L (24.9%)Rejected-Finance | L3 | Rejected-Finance Higher than L1 bidder | |
| 4 | L4₹26.5 L+₹5.7 L (27.7%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L4 | Rejected-Finance Higher than L1 bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
5 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/MAINT OF HT/LT NETWORK AND ALLIED WORKS IN COD ESTATE, VRG LINE, ME LINE AND COD INSIDE AREA UNDER GE (I) KANPUR
2023_MES_627194_1
GE(I)/KAN/T-66 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹60,000
Yes
14 Feb 2024
7 Nov 2023
12 Dec 2023
7 Nov 2023
5 Dec 2023
21 Nov 2023
Amount
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,foundation filling of poles or stays and for rerouting of cables.
All as per item No-1 but depth exc 1.5 mtr but not exc 3.00 mtr
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
M&L for cement concrete ( 1:4:8) type D2 using 40mm graded stone aggregate for foundation filling of poles as mass concrete.
M&L for cement concrete ( 1:3:6) type C2 using 40mm graded stone aggregate for foundation filling of stays.
Disconnecting electrically and taking out old unserviceable HT UG cables any type of size 70 to 120 Sqmm 3 core all as spfd and directed.
Supply, laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with alumn conductor of cross sectional area 95 Sqmm 3 core 11 KV rated suitable for earthed system including testing and commissioning all as specified and directed Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately).
All as per item No-10 above but HT 11 kV cable of size 120 Sqmm.
Supply and fix in replacement of cable straight through jointing kit for 11 kV grade cable termination cold shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm.
Supply and fix in replacement cable end jointing kit for 11 kV grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm.
Supply and fix in replacement cable end jointing kit for 11 kV grade cable for outdoor termination cold shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm.
Demolition of cement concrete (un-reinforced) in ground, floors or pavings not exceeding 15 cm thick below or above ground level complete all as specified.
M & L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in floor / hard-standing, surface finished even and smooth without using extra cement to match with the existing surface complete all as specified.
Boring of holes under road ,pavement hard standing manually incl Gi light grade pipe upto 80 mm dia suitable complete all as specified and directed. (Pipe shall be measured and paid separately)
Dismantling stay assy complete including excavation for taking out PCC block breaking of PCC block for taking out MS plate and depositing iron item to MES store yard and removing of PCC from site.
Dismantling PCC/steel poles any type and any size including excavation for taking out pole, breaking of PCC block with due care and setting aside for reuse or depositing to MES stores yard.
S & F in replacement of Power / Control Copper Cables, with solid copper conductor, XLPE insulated, 2.5 sqmm, 6 core cut to pieces including making all necessary connections as per site requirement and removing the old unsv control cables from ducts etc complete all as specified and directed by Engr-in-Charge,
Supply, errecting and installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) duly painted with two coat of black bituminous paint through out, internally and externally up to planning depth and painting remaining portion of pole with two coat of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making/painting three Nos circular strips each of 30 cm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking pole number with black paint all as spfd and directed. (Note : Excavation, earth work, PCC work shall be measured and paid separately under respective items)
Disconnecting electrically, dismantling from foundation with due care and setting aside HT Feeder pillar box any type any size with all accessories.
S&F in replecement HT 11 kV bus bar outdoor type weather and vermin proof factory fabricated CPRI approved duly painted with two coat of enamelled paint, pedestal type made out of mild steel sheet 3.15mm thick, factory made, using angle iron 40mm x 40mm x 6mm and 500mm high, front opening double shutter weather proof , rust proof, dust proof with provision of rubber gasket and locking arrangement including HT bush, insulator & 600 Amp rated bus bar color code - 03 Nos and making connection with suitable size of thimbles, nuts, bolts and washers etc incl necessary earth work complete all as specified and directed by Engr-in-charge.
M&L for replacement of GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
All as per srl item No 24 but 50mm bore
All as per srl item No 24 but 40mm bore
S & F in replacement of in position retro reflective sign board size not less than 2.5 ft to 2 ft, cut to sizes/shape made out of 3 mm thick high density aluminium sheet fixed on wall with aluminium frame work with all weather effected duly riveted with vinyale sheet based of blue colour base by hot process including letter/number as directed fitted on wall with proper arrangement all as specified. Note : The subject matter, font , size & colour is to be decided by Engr-in-charge
M&L for Insulating mats made of Elastomer for use as floor covering for the protection of workers on AC high tension installations with the system voltages up to 11 kV AC and 240 V DC and as per IS:15652 latest in size of 2000X1000mm, class B type, thickness 2.5 to 3.0 mm of sheet blue/black in colour complete as spd and directed by Engineer-in-charge
Removal of unwanted vegetation/bushes/small plants shrubs around the water/electric supply installations/ inside the valve pit and surface excavation not esceeding 15 cm depth leveling the ground and removing the excavated material to a distance exceeding 50 M.
Detection of any type of fault in HT/LT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable. Note : 1. Detection of fault in one span of length will be measured as one Job either machine placed from one side or both side of the cable. 2. Technicians will be employed by the working agencies. 3. Earth work and taking out will be measured and paid seperately. 4. Material for repair and replacement measured and paid saperately. 5. One job shall be measured if the fault has successfully identified by the fault locator machine or removing moisture in the cable if required.
M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25 x 4mm thick for earthing lead fixed by means of nuts,bolt,washers etc.of copper / brass connected to earth test point complete all as specified in electrical plate NO 3 of SSR 1996 part 1 ,including necessary excavation and earth work in any strata of soil,GI water pipe with 20mm dia.funnel &wire mesh PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity.
All as per srl item No 31 but connected to galvanised iron strip 32x6mm Earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electric plate No 3 connected to earth test point all as specified.
M & L for fixing earthing strip 32 x 6 mm GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, complete all as specified & directed.
Taking down carefully transformer of any make, any type from pole / plinth by dismantling, dis-connecting HT & LT sides, earthings of transformer, supporting angles / cross arms, shifting / transporting transformer carefully from the site and shifting/refixing at other location under GE (I) Kanpur after cleaning and making all electrical/earthing connections complete all as specified and directed.
Transportation of Transformer from site/ E/M yard to workshop for repairing and from workshop to site /E/M yard after repair etc of capacity upto 250 kVA complete all as specified and directed.
Description all as per item No 35 here-in-before but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.
Description all as per item No 35 here-in-before but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.
Dismantlling top cover of transformer of capacity upto 250 kVA , any make for repair / replacement of HT / LT bushing of transformer or for replacement of top cover gasket or for inspection of transformer or for minor internal repairs of transformer including draining carefully transformer oil as required / upto the required level and refilling the same, re fixing the top cover of transformer after completion of the work including testing on completion complete all as specified and directed. Note - spare parts will be measured and paid separately under respective items.
All as per item No 38 here-in-before but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.
All as per item No 38 here-in-before but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.
Material and labour for dismantling of complete HV/LV coils of transformer upto 250 kVA (11/6.6/0.433 kV) and segregating, serviceable and unserviceable coils, serviceable coils shall kept aside for reuse after complete varnishing and testing of each coil including removal of complete core and accessories such as HV / LV bushings with metal parts, oil temp indicator ,winding temp indicator and disconnection of OTI, WTI complete all as specified and directed. Note : (i) Rewinding of defective HV/LV Coils shall be measured and paid separately. (ii) The rate deemed to be included of all tools and plants.
Description all as per item No 41 here-in-before but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.
Description all as per item No 41 here-in-before but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.
Dismantling old un-serviceable HT 11 kV bushes and fixing in replacement of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity up to 250 kVA complete all as specified and directed.
Description all as per item No 44 here-in-before but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.
Description all as per item No 44 here-in-before but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.
Dismantling old un-serviceable LT bushes and fixing in replacement of LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, locknuts and rubber seal for indoor/outdoor transformer of capacity not exceeding 250 kVA complete all as specified and directed.
Description all as per item No 47 here-in-before but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.
Description all as per item No 47 here-in-before but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.
Repairs to the leaks of transformer of any cap from tap switch/ fins/ any pats of body, by replacing gasket / seal, or Repairs to the leaks of transformer body / fins, by welding / brazing etc complete all as specified and directed.
M&L for taking out old burnt winding and rewinding of HT/LT coil of different type, upto 250 kVA capacity and any make of transformer with approved quality supper enamelled copper wire/ strip of approved make of suitable gauge and number of turns along with allied materials like cork sheet, fibre glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. all as required at site complete all as specified and directed.
All as per item No 51 here-in-before but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.
All as per item No 51 here-in-before but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.
S&F Top gasket made of 3mm thick cork sheet with suitable holes for 11/6.6/0.433 kV transformer of any type/capacity including providing suitable size of bolts, nuts and washer for transformer top cover complete for any capacity/size transformer complete all as specified and directed.
Disconnecting electrically, open the cover of transformer any type/size and filtration and dehydration of Transformer oil for 11 / 6.6 / 0.433 kV transformers, with stream line mobile filtration plant (To be provided by contractor & quoted prices deemed to include its hire charges) at a temp from 60-75 degree celsius to achieve the dielectric strength of oil 60 kV or over at standard gap as per IS 335 of 1993 (Fourth revision) to remove the moisture from winding and core complete all as specified and directed. Note : (a) Filtration should be carried out in OFF position, therefore generator and cables will have to be arranged by the contractor at his own cost. (b) Test result will be recorded before and after filtration of oil and submitted to Engr-in-Charge in a prescribed manner.
M&L for Open the cover of transformer any type/size on site/ in workshop for rep & maint and filling in with new transformer oil low viscosity of approved make as per IS-335 of 1992 including heating of oil and die-electric strength 40 kV when tested at 4mm gap complete all as specified and directed.
S&F in replacement of temperature gauge circular dial type of standard size and dia suitable for indoor/outdoor type transformer upto 400 kVA complete all as specified and directed.
M&L for replacement and full fill up fresh silica gel in assembly at site complete all as directed and specified.
Servicing / Calibration to 11/6.6 kV HT VCB complete including the following (a) Taking out 11/6.6 kV HT VCB of 630/800/1250 Amps rating trolley from HT Panel after switching off electric supply. checking of mechanical system for proper functioning of upward / downward movement of HT VCB trolley including opening the VCB & checking the mechanical system. cleaning & servicing the fixed / moving contact & blowing out dust and applying the proper lubrication / greasing and reassembling the VCB / SF6 including connection to HT panel complete insulating oil to be replaced where reqd complete all as directed and specified. (b) Taking out relay set of any make from HT 11/6.6 kV VCB panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by EIC. (Note for (a) & (b):- (i) Replacing new items shall be measured and paid separately as supply only. Note : Minor spares if required shall deems to be included with the above job.
Supply only shunt trip coil assembly suitable for HT, VCB panel 11/6.6 kV, operating on 30 / 110 volt system and testing complete all as specified and directed.
Supply only closing / tripping coil operated on 110 / 30 volt system as per sample suitable for working of relay of HT VCB panel complete all as directed and specified.
Supply only fabricated gears as required for spring charger of VCBs as per sample.
S & F in replacment charging motor for 11 kV, VCB, 1250 Amps operated on 230 volts DC as per sample complete all as specified and directed.( Make:- Electra / Delco or equivalent as approved by GE ) .
M&L for the CTs of ration 200/100/5, with 5 P 10 as per sample for protection and class-I accuracy having 15 VA burden all as directed by Engr-in-charge.
S & F in replacement indication lamp (LED type) Red or Yellow or Green colour suitable for 110 volts AC / 110 volt DC / 30 volts DC (as required at site) complete all as specified and directed.
M & L for cleaning,rubbing,preparation for painting all surfaces of Steel tubular poles 9/11 mtr with security light bracket or clamps,channels etc complete and painting all surafces of the same with AL paint 2 coat complete with black & yellow stripes (total 5 nos with 30 cm width from bottom of poles) complete all as specified and as directed by Engr-in-charge.
M & L for cleaning,rubbing with suitable cleaning agent & T&P to all surfaces of any Type of Transformers/RMUs/LBSs complete all as specified and as directed by Engr-in-charge.
M & L for fixing of Power packs as per sample for back up time of VCBs/RMUs 110V DC for suitable working of relays complete with accessories and including connection with suitable size of copper control cable as required all as specified and as directed by Engr-in-charge.
Supply and fixing of CO2 fire extinguishers wheel based suitable for electrical fires, non toxic,leving no residue and will not harm machinary & electrical equipment complete with accessories of weight not less than 9 kg complete with suitable stand for ground all as specified and as directed by Engr-in-charge.
M&L for electrical shock & its treatment chart in size not less that 70X50cm duly frames with good quality hardboard and fixeed to walls of substations complete all as specified and as directed by Engr-in-charge.
M & L for MS work with hand rails ,half round or other stock section ,drilled and countersunk for balusters running bars,including embeding in concrete and screwing etc , struts in fencing including cutting tops to shape as directed ,drilling holes ,notching for wire etc,flat iron fillets (for securing wire mesh/XPM net etc) including all necessary drilling ,bolting or riveting and similar work conforming ton Fe--290 Gde E-165,with two coats synthetic black paint on steel surfaces complete complete including dismantling of old detoriated fencing and cement concrete type B-2 1:2:4 (40 mm graded having 100 mm thick) complete all as spd and directed.
M & L for PVC coated chain link fencing with mesh size 50X50 mm, GI wire dia not less than 4 mm and final PVC coated diameter should not less than 5 mm, height not less than 1 mtr from the plateform, colour of mesh will be decided by Engr-in charge and fixed complete to MS angles complete all as spd and directed. NOTE: MS angles will be measured in item no 72.
M & L for aggreagtes for loose filling near by HT infrastructuire as RMUs/Trasnformer plateform/ HT poles of size not less that 40 mm graded stone boulders complete all as specified and as directed by Engr-in-charge.
A.B.Enterprises
S B ENTERPRISES
Bharat Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .