| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹6.2 L+₹21,492.26 (3.57%)Rejected-Finance | L2 | Rejected-Finance OK | |
| 3 | L3₹6.7 L+₹64,375.97 (10.7%)Rejected-Finance | L3 | Rejected-Finance OK | |
| 4 | L4₹6.8 L+₹81,129.85 (13.5%)Rejected-Finance NULL | L4 | Rejected-Finance OK |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
19 May 2020, 5:00 pmClosed
Executive Engineer
CCS HAU, Hisar
Conversion of existing lecture room No. 1 into smart classroom for the Department of Soil Science in the premises of College of Agriculture at CCS HAU, Hisar. (including PH and EI works)
2020_HRY_124081_1
3161-C
Open Tender
Civil Works
Works
60 days
CCS HAU HISAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Executive Engineer C2
₹10,000
14 Aug 2020
17 Mar 2020
21 May 2020
18 Mar 2020
19 May 2020
18 Mar 2020
Amount
Civil work 1 to 23:- Scraping {HSR 8.32 (a) } (a) White wash and colour wash
Providing and fixing false ceiling with 12 mm thick Gypsum Board fixed on M.S. steel runners frame including cost of screws angles, cleats, rawel plugs with taping, filling with Gypsum compound and applying priming coat etc. complete in all respects (HSR 13.91)
Providing and fixing mineral fibre false ceilings tiles at all hieghts of size 595 x 595 mm of approved texture, design and pattern, the tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity K = 0.052 (-) 0.057 w/m k, Fire Performance as per (BS 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round gavanized iron section of 0.33 mm thick (galvanized @ 120 gsm) comprising of main T runners of 15 x 35 mm of length 3000 mm, cross T of size 600 x 600 mm suspended from celing using galvazied mild steel item (galvanizedd @ 80 gsm) 50 mm long 8 mm outerdiameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85 x 25 x 2 mm, spaced at 1200 mm centre of centre along main 'T'. The suystem should rest on periphery walls/partitions with the heop of GI perimeter wall angle of wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all hieghts, The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-charge. with or without groves (HSR 13.92)
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead , linseed oil, varnish and chalk mitti including finishing the surface to required finish complete(HSR 16.1)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping, etc. (HSR 16.2)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade (HSR 16.3)
Painting one coat with synthetic enamel paint in all shades on old wood work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint (HSR 16.7)
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces (HSR 16.25)
Spirit polishing one coat on old work (HSR 16.45)
Preparation of plastered surfaces for oil bound distemper including sand papering the surface, applying one coat of linseed oil, and filling with approved quality filler, consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to the required finish complete (HSR16.52)
Distempering with washable oil bound distemper (of approved manufacture) two coasts excluding priming coat on new work (HSR 16.57)
Supplying and fixing hydraulic door closer, I.S.I. mark, with necessary screws , etc., complete- (HSR 17.82(b )} (b) I.S.I. designation No. III ( size of door 701 mm to 850 mm)
Providing and fixing plastic laminated sheets thickness, not less than 1.5mm(conforming to I.S. Specifications), including cost of approved adhesive complete. (HSR 17.88 (a)} (a) natural finish
Factory manufactured solid flush door shutters, with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part I and II, fixed in position, including iron hinges, screws, chocks/cleats and stops, etc., (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position)- (HSR 17.93(a)} (a) commercial veneering with vertical grains or cross bands and face veneer on both sides commercial facing with laminated core and lipped edges :- (i) 25 mm thick
Providing and fixing vitrified tiles of size 600 mm x 600 mm of approved make in flooring, laid in any pattern as specified over base of adhesive of reputed brands such as Pidilite, Laticrete, Ferrouscrete & Valendure as per IS specification 15477-2004 and jointed with white cement slury mixed with pigment to match the shade of tiles.(NS) Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, JOHNSONS, RAK, ORIENT BELL AND SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this
Providing and fixing vitrified tiles of size 600 mm x 600 mm of approved make in skirting/ dado, laid in any pattern as specified over base of adhesive of reputed brands such as Pidilite, Laticrete, Ferrouscrete & Valendure as per IS specification 15477-2004 and jointed with white cement slury mixed with pigment to match the shade of tiles. (NS) Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, JOHNSONS, RAK, ORIENT BELL AND SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.
Providing and fixing readymade white writing board of PRESKO make with Delux frame or any other similar brand, fixed in position, including wooden gutties , nails and screws, etc., complete in all respects as per drawing and design.(NS)
Providing and fixing wall paneling (on wall) consisting of following:- Frame work:- Consisting of factory manufactured G.I. channel of size 43 mm x 15 cm x 0.8 mm fixed horizontally @ 2’-0” C/C with rawl plugs/ screws on wall. (a) 12 mm thick BWR grade-II plywood (ISI mark) of approved make fixed on G.I. channel frame. (b) Top portion:- Consisting of 0’-6” wide strips of 1 mm thick plastic laminated sheet (ISI mark) of approved make, shade and colour with 1/8’ groove fixed on plywood. (c) Beading:- Beading of size 0’-2¼” x 0’-1¾” of commercial hard wood such as hollock, champs, chikrasy and chaplash at top. Including cost of sprit polishing, rawl plugs, nails, screws etc., complete in all respects as per architectural drawing and design or as directed by Engineer In-charge. (NS)
Manufacturing and supplying Rostrum/lecture stand consisting of 19 mm one side teak board (ISI mark), M.S. square tube of size ¾” X ¾” of 14 gauge and 12 mm thick one side teak ply ISI mark including nails, screws, wooden screws, spirit polishing, black paint, fevicol etc., complete in all respect as per Arch. drawing and design/as per sample(NS)
Taking out cup board shutters from chowkat including removing of fittings carefully for its re-use and shifting of shutters to store, complete in all respects directed by Engineer-in-Charge.(NS)
Removing of old damaged plastic laminated sheet from wooden worktop & making the surface rough, complete in all respects as directed by the Engineer in Charge. (NS)
Tacking (making rough) of existing conglomerate/terrazzo flooring for laying vitrified tile flooring (excluding cost of vitrified tiles) including disposal of malba and cleaning the surface etc., complete in all respect as directed by Engineering In charge (NS)
PH work 24 to 27:- Providing and installing split type air conditioners, four star rating inverter type with copper coils 1.5 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-410-A suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:- (i) Cooling coil row -3 Nos. (ii) Air flow (CMH) -1000 cum/ hr. (iii) Sound level (H/M/L)- 45/38/26(silent mode) (iv) Louvers swing- 3D + 3D Auto etc. complete in all respect MAKE :- O General/Toshiba/Mitsubishi (Heavy Industries) (four star rating) Model as approved by the Engineer-in-Charge
Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity (heavy duty) copper wound 100 up voltatge ofV-Guard make ISI marked complete in all respect. (N.S.)
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. (NS) NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 12.7 mm(½") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit. (NS)
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts & bolts etc. of best quality complete in all respect (NS)
EI work 28 to 50:- S/E of MCBs/isolator 240/415 V in existing distribution board including making necessary connections :-( HSR 31.17 ) (i) 6 to 32 amp. MCB SP
(ii) 6 to 32 Amp MCB SP&N
Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required:- ( HSR 31.21 ) (xv)Heavy gauge welded conduit pipe 25 mm dia 1.60 mm thickness on surface
Supply and M.S. pipe (B-class) for suspension rod of ceiling fan including threading if required. (HSR 31.35) a) 15mm dia
S/E of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe.( HSR 31.40 ) i)Cable Size 1.5 sqmm
(ii) Cable Size 2.5 sqmm
(iv) Cable Size 6.0 sqmm
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto to the entire satisfaction of the Engineer-in-charge of the work. ( HSR 31.41 ) (ii) 8-Way, SP&N (Horizontal)
(v) 4 way TP&N Horizontal ( 8+12 )
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall/ceiling etc. including cost of PVC bends, inspection box and all other material required to complete upto the entire satisfaction of Engineer-in-charge of work (HSR 31.44) (b) 25mm dia
Pdg. & fixing modular type accessoriesm of app. Make in existing box including fixing and making necessary connections complete in all respect. ( HSR 31.56 ) 10 amp. 1 way switch
20 amp. Switch
10 amp. Socket
16 amp. Socket
Fan Regulator
Pdg & fixig GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate with all labour and matrial required for the job. (HSR 31.57) 1&2 Module
6 Modules
12 Modules
S/E of recessed type 42 watt full window glare free opal difffuse LED panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 4600 or above in cool day light (5600k to 6500k), Power factor >0.95, CRI (Ra) >80, LED lamp efficiency ≥140 lm/w, Average life >50000hours, complete with all accessories as required with connections. (Industrial) (NS) Make: Bajaj, Havells, Crompton, Vipro etc.
S/E of Cat 6 wire for internet make D Link in existing pipe. (NS)
S/E Modular Internet jack RJH-45 with cat-6 AHLKJWG451 (NS)
S/E of AC ceiling far capacitor type complete with shackle 300mm down rod etc with rating 5 star i) 1400mm sweep. (NS) Make: Bajaj, Havells, Crompton, Vipro etc.
S/I/T/C of push on/off type 25 & modular type motor starter switch ( white color ) for AC's including the cost of petty material required to complete the job upto the entire satisfaction of engineer incharge. (NS)
Baljeet Kaswan Contractor
nagpal and company
Jaideep Kumar Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .