Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹12,500
Closing Date
23 Aug 2023, 11:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Directorate of Municipal Administration
RENUKAMMA
power supply to Electrification of street light in the name of the Chief Officer T.M.C. Kakkera Town site at Old Panchayat Office to Dr Ambedkar statue & Bazaar line, In O &M Devapur Section of O & M Sub Division GESCOM Shorapur
DMA/2023-24/TL/WORK_INDENT1501
DMA/2023-24/TL/WORK_INDENT1501
Open
Transmission Line
Electronic Documents, First(One Cover)
DMA Town Municipal Council Kakkera
4 documents required · 0 mandatory · 4 optional
₹500
₹12,500
16 Aug 2023
16 Aug 2023
22 Aug 2023
power supply to Electrification of street light in the name of the Chief Officer T.M.C. Kakkera Town site at Old Panchayat Office to Dr Ambedkar statue & Bazaar line, In O &M Devapur Section of O & M Sub Division GESCOM Shorapur
279020-11kV Horizontal X arms - Mild
Fixing of V-Shape/Horizontal cross arm including single top support Braces and Insulators fixing.
279140-Anchor Rod using 12mm rounds/G
a) Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
279146-Turn buckle (GI)
279523-RCC Pole clamp - MS
279650-Guy clamp - MS
281110-7/10 SWG Guy Wire
a) Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel
283040-DISC Insulators 45kN
283166-NO.15 Strain Insulator
284108-Rabbit ACSR Conductor
733616-B & N Size 16X65mm
For Rabbit ACSR for labour charge
200103-RCC Pole-8.0M Long,115 kg WL
278811-11kv Danger board
278911- Barbed wire (10 mts.)
279111-25/63kVA T.C.Sets (For star ra
279140-Anchor Rod using 12mm rounds/G
Same as above but erection of RCC/PCC/PSC poles of 7.5 to 8 mtr long in pit of 1.5 mtr depth.
Fixing Danger Board
G.I. Barbed Wire (12 mtrs/1kg)
Erection of pole Upto 63 kVA with 9 mtrs. RCC pole
a) Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
279146-Turn buckle (GI)
279149-11kV G.O.S.Mounting H-Frame se
Errection of H Frame.
279650-Guy clamp - MS
279800-Fish Plate - MS
281008-8 SWG G.I.Wire
281110-7/10 SWG Guy Wire
a) Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
281674-G.I.Grounding pipe, B-Class, 4
Earthing Materials type for grounding
283005-11kV Pin Insulator (Shell onl
283040-DISC Insulators 45kN
283055-11kV Pin Insulator (G.I Pin o
283166-NO.15 Strain Insulator
284503-LT Spacer for TC Wiring
285549-Weasel to Rabbit
285555-95 Sq.mm (P.G. Clamps Rabbit
a) Wiring of One circuit of LT Wiring Kit for for 25/63/100 KVA DTC to the existing LT protection Kit Kit / Distribution Box via metering box.
289029-PVC Wire-50 Sq.mm
Wiring for lightinh/power circuit using one of PVC insulated 1100v grade stranded Aluminum unsheathed wire 4 Sq mm single core/multi core cable in open or cocealed system of wiring (10/521)
301107-L.T.Protection kit
Protection Kit Fixing of LT
302122-11kV Class, Solid core
HG fuse 11 kv Solid core type(3 nos
303200-L.A. 9kV, 5kA, Metal Oxide
Fixing of 3 Nos lightning arrestors including wiring.
304212-11kV G.O.S 200A Single break
Fixing of GOS including wiring (11kV SB 200A)
321437-25kVA, Aluminum Wdg, BEE 4 Sta
a) Erection of 25-63 kVA Transformer on Transformer structure.
600095-Good Quality well burnt Charco
607054-Good Quality Salt for groundi
200103-RCC Pole-8.0M Long,115 kg WL
Same as above but erection of RCC/PCC/PSC poles of 7.5 to 8 mtr long in pit of 1.5 mtr depth.
284223-Piercing connector suitable fo
Installation of Insulation piercing connector for main to street light Main : 16-95sqmm, Tap : 1.5 TO 10sqmm(EP95)"
284284-Universal hook & Bolts & nuts
Erection of Suspension Clamp - 25 to 95 sqmm insulated messenger with bracket
Fixing of Universal Hook
284819-3x95+1x70+1x16 street light (I
Stringing of 1.1kV grade aerial bunched 3 core cable of XLPE insulation standard aluminum conductor, standard around a weather resistant black XLPE insulated AAA messenger wire 1. (3x95) (for Phase co...
284825-Dead end clamp / Anchor clamp
Erection of Anchor Clamp - 25 to 95 Sq. mm bare messenger
284826-Suspension clamp assembly 25 t
Erection of Suspension Clamp - 25 to 95 sqmm insulated messenger with bracket
284829-Tee-connectors- KZ3 95
Installation of Pre-insulated lugs-CPTAU for 95sqmm
284832-Straight joints suitable for 9
Installation of Pre-insulated straight thru joints-MJPT for 25sqmm cable
284833-End cap for 50/70 Sq.mm
End cap for 50/70 Sqmm
284837-Pre-Insulated lugs-CPTAU for 9
Installation of Pre-insulated lugs-CPTAU for 95sqmm
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
KW Kakkera TC.docx
Tender Document • 0.92 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .