SE EUDC-I, LESA
Office of the SE EUDC-I, LESA
Construction of Electrical infrastructure for Release of against Sanction load to the new consumers and other associated works, at 33 avam 11 KV CG City-4 and Hariharpur
2020_MVVNL_536990_1
71/EUDC(I)/2020-21
Open Tender
Electrical Works
Fixed-rate
365 days
under the jurisdiction of EUDD Rajbhawan
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Central bank of India
₹15,000
28 Dec 2020
11 Dec 2020
18 Dec 2020
11 Dec 2020
18 Dec 2020
11 Dec 2020
180 days
Amount
Construction of new Electrical infrastructure for Release of Sanctioned load to the consumer’s premises against deposit works.
Safe carriage, loading-unloading with proper stacking of following material from ESC-Daliganj to Work Site/JE -Dump Store –
(A) P.C.C. Pole 8.5 meter long
(B) 9/11 Meter Long S.T. Pole
(C) 11 KV XLPE Cable 3x70/120/185 Sq.mm
(D) 11 KV meter Cubicle
(E) 11 KV CT & PT Unit
(F) Line materials like Angle 65x65x6 & M.S.Channel 10x50x6 Sq.mm
(G) Transformer 25 KVA/10 KVA
(H) Transformer 63 KVA
(I) Transformer 100 KVA
(J) Transformer 250/400 KVA
(k) LT cable 3.5x240/400 Sq.mm
(L) LT ABC Cable 3x95/120 Sq.mm
(M) ABC cable single phase (1x25+1x16)
(N) LT DP box for ABC
(O) Cable Jointing kit O/D 3x70/120/185 Sq.mm
(p) G.I.Wire 10 SWG
Fabrication erection of exposure Double pole structure on 9/11 Mtr long ST pole including mounting of one no. top channel of size 100x50 mm 2.25m, two nos. dropper angle with clams and nut bolts, with fixing of necessary clamps, accessories required, grouting in 1:4:8 cement sand, brick ballast and making of plinth 300mm above ground level. The pole will be planted on the stone pad of size 300x300x7.5 mm ST pole shall be supplied by the deptt.
Fabrication, erection, grouting plinthing and painting of Substation type double pole on 9/11 M S.T. Pole providing top channels of size 100x50x2240 mm, MS Dropper channel 100x50x2000 mm with D.O. arrangement including mounting of clamps with nut & bolts, 11 kV Pin Insulator with pin poles will be planted on Stone pad of size 300x300x75 mm, Danger board (Only STP will be provided by the deptt).
Fabrication erection of exposure Double pole/Sub station type double pole on PCC pole 8.5 Mtr long with fixing of necessary clamps, accessories required including supply and fixing of straight MS 100x50 mm. (2240 mm long) n Nos. With arrangement of fixing 3 Nos. pin insulator, grouting in 1:4:8 cement, sand, brick ballast and making of plinth 300 mm above ground level along with D.O Fuse set as per RESPO span. & direction of E/I. ST pole shall be supplied by the deptt.
Fabrication, erection, of single pole 11 Mtr long ST pole with fixing of necessary clamps, accessories required including supply and fixing and digging of pit and fixing of all accessories claps as well as grouting and plinthing of pole as per RESPO norms (Clamp shall be supplied by Contractor).
Fabrication, erection, grouting plinthing of single pole on 8.5 Mtr PCC pole including mounting of T-off channel with nut & bolts 11 KV LT line including mounting grouting of support and plinthing 300 mm above ground level, fitting of 11 KV pin & insulator. 1/6 of total length of poles will remain under the ground and planted on stone pad of size 300x300x75 mm.
Erection of stays with stay set of 16X1800 mm rod duly painted with red oxide, anchor plate, thumble turn buckle and stay insulator etc. digging of pit of size 0.4X0.6X1.6m for grouting by 1:3:6 cement concrete, with stay of size 7/10 swg, nozzling & grouting. (stay set & stay wire will be provided by the department).
Earthing of poles as per RESPO norms with earth rod. (All the materials supplied by contractor).
Stringing, sagging, binding, jump ring of 11 KV 3 phase 3 Wire line with ACSR Conductor.
Stringing, sagging, binding and jumpring of AB Conductor with the help all type of clamps (cost of clamps shall be borne by the contractor)
AB Conductor 3x95/3x50. (Except A.B.C All the materials supplied by contractor).
AB Conductor 1x25+1x16. (Except A.B.C All the materials supplied by contractor).
Mounting and fixing of 3 phase Distribution Box as per norms(All the materials will be supplied by the contractor ).
Mounting of 10 KVA/25 KVA transformer as per RESPO Norms along with all accessories.(Except T/F all the materials will be supplied by the contractor).
Mounting of 63/100 KVA transformer on double pole structure as per RESPO Norms.(Except T/F all the materials will be supplied by the contractor).
Construction of masonry type transformer plinth of size 2x2x1.5 M with brick, cement, coarse sand, sand & brick ballast, filling of sand in the hollow space, plastering outer surface in ratio 1:4:6 top of the plinth 4” thickness grouting of 2 nos. MS Channel of size 100x50x2000 mm on the top of the plinth for placement of transformer. (All the material will be arranged by the contractor).
Installation, commissioning of 250 KVA Transformer including its connection in between 11 kV line and LT line mounting of copper L-Pieces 300X65X6 mm, Providing Aluminium Crimping lugs of size 400 Sq. mm. (All the material except transformer will be provided by the department)
Installation, commissioning of 400 KVA Transformer including its connection in between 11 kV line and LT line mounting of copper L-Pieces 300X65X6 mm, Providing Aluminium Crimping lugs of size 400 Sq. mm. (All the material except transformer will be provided by the department)
Laying of 11 kV 3x70/120/185 Sq. mm in normal soil by digging of trench of size 900 mm deep 500 mm wide. The cable will be laid in between two rows of first class bricks after spreading 3” local sand at the bottom of the trench and packing of cable with local sand from each side and covered with bricks (Only cable will be provided by the department).
Laying of 11KV XLPE Cable 3x70/120/185 Sq mm upto 1 M deep through Drilling Method. (Except 11 KV XLPE cable all the labour and T&P will be provided by Contractor).
Laying of 11 KV 3x70/120/185 Sq.mm cable in G.I.pipe 4” dia under road crossing .
Cradle type guarding of 11 KV line made of GI No. 10, GI wire shall be supplied by the department.
Hoisting of 11 KV 3x70/120/185 Sq. Mm XLPE cable on existing pole. Cable will be passed through M.S Pipe of required size duly clamped with pole at the bottom, middle and top of the pole.(All the materials will be arranged by the contractor).
High Pressure testing of 11 KV 3x70/120/185 Sq.mm XLPE cable through 18 KV DC Supply withhold for 5 minute. (All the labour and T&P will be provided by Contractor).
Chemical Earthing system with outer pipe diameter 50mm, inner Strip 40x6, length 3000 mm. galvanization up to 200 micro, earthing pipe with crystalline conductive mixture filled inside the pipe with anti-corrosion & high conductive along with 50 Kg(As per required) of BFC which should be capable to reducing the soil resistively with good moisture retaining capacity.(Specification of chemical earthing and drawing is hereby enclosed). All material shall by supply by the contractor. (As per Drawing enclosed)
Installation and commissioning of CT/PT Metering unit including its connection in between TVM Meter and CT/PT Unit with required size of copper cable. Cable will be arranged by the contractor as his own cost.
Fixing of metering cubicle.
Construction of retaining wall, fabrication & erection of Wire mesh fencing of size 5+3 & 2.0 M height around Transformer and Distribution Pillar Box with retaining wall & 1 no. gate with locking arrangement made of MS Angle iron of size 50x50x6 mm jointed with nuts and bolts. The panel must be supported with MS Flat of size 50x6 mm. Wiremesh of size 10 SWG rectangle type, its painting as per norms of RESSPO. (All the material will be arranged by the contractor at his own cost).
Construction of massonary type Distribution Pillar box with first class brick ballast cement, coarse sand, local sand, brick ballast and MS Round bar of 10 mm dia including supply and mounting of 02 nos. Straight MS Angle 50X50X6X750 mm-2 nos, Henley type tailless fuse units 500 Amps. 650 Volts one no. for incoming and other for outgoing, Copper bus bar 1000X50X6 mm with locking arrangement made of 18 SWG BP Sheet (All the material will be arranged by the contractor).
Laying of LT PVC cable of size 3.5x240/400 Sq. mm by digging of trench in between newly constructed Distribution pillar box and existing pole providing Crimping type aluminium lugs of suitable size of cable.
Installation of RMU including grouting & plinthing
Construction of new Electrical infrastructure for Release of Sanctioned load to the consumer’s premises and dismantling/shifting existing line against deposit works.
Dismentaling of old 9/11 m S.T. pole along with ACSR conductor/ABC.
Dismentaling of old PCC Poles along with ACSR conductor/ABC.
Carriage of dismantled of old PCC Poles/ST pole & carriage of the same from site to J.E. dump store/ESC Daliganj.
All taxes applicale shall be paid time to time extra.
Sidhi Enterprises
P.S. ENTERPRISES
S M ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .