Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹40.8 L+₹11,250 (0.28%)Rejected-Finance VILL JASSAI DISTRICT BARMER RAJ 344001 | JASSAI | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹44.9 L+₹4.2 L (10.3%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹47.9 L+₹7.3 L (17.9%)Rejected-Finance S O KALA RAM C O LALIT AND BROTHERS UTARLAI UTTARLAI VPO UTTARLAI BARMER RAJASTHAN 344001 | BARMER | RAJASTHAN | 344001 | L4 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | m/s jogaram sujaram L2 | Lalit and Brothers L4 | Devi Engineeing L3 | S.K. INFRASTRUCTURE L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. | 53 | Cum | 100 ₹5,300 Lowest | 230 ₹12,190 | 380 ₹20,140 | 200 ₹10,600 |
| 2.00 | M & L for installation of wooden flooring as per manufacturere instruction as under:-
Surface board :- Made of kiln seasoned (Moisture containt of approximately 14% at the time of dispatch ), Treated Maple wood finished with 21 mm thick, 57 to 83 mm wide and in random length in tongue and groove shape .The edges of the boards will have a finger lock groove and the bottom side with air pass groove and treated with special anti termite and water resistant lacquer.
The Under Frame :- Made of commercial quality pine wood runner of 70 mm x 45 mm, treated with antitermite soution and fixed on he bottom side with 10 mm thick air cushioned pads, stappled through the wings at 350 mm x 350 mm
Installation :- IPS sub floor treated with a vapour barrier to be placed on the levelled IPS sub floor before laying the under frame . The runners having air cushion pads to be placed on the vapour barrier in perfect level at 350mm in 1 direction . The surface board to be screwed to the runner through the tounge only and will lockthe screwed tounge by the groove of adjoining board. Ends of the boards will be locked by adhesive . An expansion of 8 to 10 mm to be left open between the wooden flooring and the surrounding tiled area/ walls.
Game line marking :- (Red/ White shade as per badminton court rules . | 197 | Sqm | 6,300 ₹12,41,100 | 9,400 ₹18,51,800 | 6,750 ₹13,29,750 | 6,250 ₹12,31,250 Lowest |
| 3.00 | M&L for cement concrete 1:2:4, type B-1 (20mm graded aggregate) as in floors,hardstanding without using extra cement complete all specified and directed. | 10 | Cum | 4,000 ₹40,000 Lowest | 4,700 ₹47,000 | 4,500 ₹45,000 | 4,500 ₹45,000 |
| 4.00 | M&L For 25 mm thick cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) as in floors rough finished etc complete all as specified and as directed. | 197 | Sqm | 200 ₹39,400 | 99 ₹19,503 Lowest | 165 ₹32,505 | 200 ₹39,400 |
| 5.00 | M & L for painting one coat synthetic enamel paint on steel surface/ GI sheet/ any metal surface including preparation of old surface of any description , over 10 cm width or girth not otherwise described all as specified and directed.
Note for above items of finishing :- the cost for steel tubular double scaffolding necessary for execution of work and protective measures for height more than height of double storey building as directed by engr-in-charge shall be included in the quoted rate against the respective item and nothing shall be admisible for this. Also colour shade and pattern will be decided by Engr-in-charge. | 485 | Sqm | 80 ₹38,800 | 35 ₹16,975 Lowest | 85 ₹41,225 | 80 ₹38,800 |
| 6.00 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering | 140 | Sqm | 10 ₹1,400 | 9 ₹1,260 Lowest | 20 ₹2,800 | 10 ₹1,400 |
| 7.00 | S&F Pre-laminated galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering in any curvature, fixed with self tapping screws as specified. | 100 | Sqm | 800 ₹80,000 | 840 ₹84,000 | 765 ₹76,500 Lowest | 785 ₹78,500 |
| 8.00 | S&F of 2mm Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. | 20 | Sqm | 800 ₹16,000 | 740 ₹14,800 | 650 ₹13,000 Lowest | 800 ₹16,000 |
| 9.00 | Hacking out old broken glass [any thickness, size, quality or description] from metal frames including punching or drilling out old glazing pins / spring clips complete all as specified and as directed. | 28 | Sqm | 30 ₹840 | 15 ₹420 Lowest | 80 ₹2,240 | 20 ₹560 |
| 10.00 | S&F for sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed. | 28 | Sqm | 700 ₹19,600 | 650 ₹18,200 | 622 ₹17,416 | 600 ₹16,800 Lowest |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
1 Jan 2026, 6:00 pmClosed
GE (A) BARMER
GE (A) BARMER jalipa cantt
SPL REPAIR TO BLDG NO T-117 AND T-91/01 AT JALIPA MIL STN UNDER GE(A) BARMER
2025_MES_744396_1
8868/E8
Open Tender
Civil Works
Item Rate
180 days
BARMER
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (A) BARMER
₹94,000
Yes
3 Oct 2026
13 Dec 2025
3 Jan 2026
13 Dec 2025
1 Jan 2026
27 Dec 2025
Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
M & L for installation of wooden flooring as per manufacturere instruction as under:- Surface board :- Made of kiln seasoned (Moisture containt of approximately 14% at the time of dispatch ), Treated Maple wood finished with 21 mm thick, 57 to 83 mm wide and in random length in tongue and groove shape .The edges of the boards will have a finger lock groove and the bottom side with air pass groove and treated with special anti termite and water resistant lacquer. The Under Frame :- Made of commercial quality pine wood runner of 70 mm x 45 mm, treated with antitermite soution and fixed on he bottom side with 10 mm thick air cushioned pads, stappled through the wings at 350 mm x 350 mm Installation :- IPS sub floor treated with a vapour barrier to be placed on the levelled IPS sub floor before laying the under frame . The runners having air cushion pads to be placed on the vapour barrier in perfect level at 350mm in 1 direction . The surface board to be screwed to the runner through the tounge only and will lockthe screwed tounge by the groove of adjoining board. Ends of the boards will be locked by adhesive . An expansion of 8 to 10 mm to be left open between the wooden flooring and the surrounding tiled area/ walls. Game line marking :- (Red/ White shade as per badminton court rules .
M&L for cement concrete 1:2:4, type B-1 (20mm graded aggregate) as in floors,hardstanding without using extra cement complete all specified and directed.
M&L For 25 mm thick cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) as in floors rough finished etc complete all as specified and as directed.
M & L for painting one coat synthetic enamel paint on steel surface/ GI sheet/ any metal surface including preparation of old surface of any description , over 10 cm width or girth not otherwise described all as specified and directed. Note for above items of finishing :- the cost for steel tubular double scaffolding necessary for execution of work and protective measures for height more than height of double storey building as directed by engr-in-charge shall be included in the quoted rate against the respective item and nothing shall be admisible for this. Also colour shade and pattern will be decided by Engr-in-charge.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering
S&F Pre-laminated galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering in any curvature, fixed with self tapping screws as specified.
S&F of 2mm Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc.
Hacking out old broken glass [any thickness, size, quality or description] from metal frames including punching or drilling out old glazing pins / spring clips complete all as specified and as directed.
S&F for sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
Powder coated 50 microns extruded aluminium glazing/ doors & shutters made out of section 63.5x38.10x1.29mm for chowkats or frame & shutters made of size 44.45x44.45x1.29mm for side rails and middle rail, 114.3X44.45X1.29mm for top rails and bottom rails and including 12mm thick High Density Fibre Board pre-laminated on both sides (water proof) below middle/lock rail and 5mm thick tinted glass above middle/lock rail and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beads 20mm size with and incl mortice lock with duplicate keys etc complete all as specified and directed approved by accepting officer including supply and fixing the following items: (a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 3 nos per leaf. (b) Powder Coated Aluminium Tower Bolt 200mm long - 2 nos per leaf (c) Powder Coated Aluminium Handles 150 mm - 2 nos per leaf
M&L for preparation of New or previously untreated wood and wood based surfaces / Asbestos sheet cladding of any description over 10cm in girth or width and painting with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. Note for above items of finishing :- the cost for steel tubular double scaffolding necessary for execution of work and protective measures for height more than height of double storey building as directed by engr-in-charge shall be included in the quoted rate against the respective item and nothing shall be admisible for this. Also colour shade and pattern will be decided by Engr-in-charge.
S& F self propelled turbo ventilator of 1 m dia all as specified and as directed
M&L for preparation of New or old previously untreated steel or iron surfaces of any description over 10cm in girth or width and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for preparation of New concrete surface of any description over 10cm in girth or width and painting with two coats of plastic enamel paint complete all as specified and as directed.
Supply & Fixed in repair aluminium composite panel not less than 3.0 mm thick and including covered both side by encapsulated lens type retro reflective sheet (grade 3 M type II diamond grade of make 3M/dark eye/ SNI) green base,with and including all type and any size of writting letters and symbols of reflective type including all as directed by Engr-In-charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, in hard / dense soil returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
S&F Wire netting of stainless steel wire 0.91 mm dia 20 mm apparture fixed with tinned tacks of stainless steel wire staples to existing roof bottom steel frame work including all necessary connecting fittings all as specified and as directed Note for above items of finishing :- the cost for steel tubular double scaffolding necessary for execution of work and protective measures for height more than height of double storey building as directed by engr-in-charge shall be included in the quoted rate against the respective item and nothing shall be admisible for this.
S& F badminton post including welding , made to shape , embedded in PCC block , conforming to Fe 290 Gde E-165
Dismantiling wrought iron or mild steel work of any description not otherwise provided for etc comoplete all as specified.
S&F for Steel work in tubular trusses,post,purlin,rafter including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240
M&L for preparation of New or old previously untreated steel or iron surfaces of any description over 10cm in girth or width and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar. Note : Work will be in patches or in bulk
M & L for Machine cut kota stone slab flooring 20-25mm thick over, laid over cement screed base , jointed and pointed with grey cement slurry mixed with pigment over 20mm thick cement mortar 1:6 screed bed to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed. Note : Work will be in patches or in bulk
M & L for Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10 mm thick cement plaster 1:3 jointed and pointed with grey cement slurry mxed with pigment to match the shade of the slab including rubbing and polishing complete, all as specified and directed.
M & L for 75 mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in subbase of flooring / hard standing as specified
M & L Hardcore using broken stone boulders not exceeding 63mm deposited spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surfaces complete all as specified & directed.
M & L 6mm thick asbestos cement, corrugated or semi-corrugated or plain sheets in roofs, walls Fixed with coach screws etc all as specified and directed by Engr-in-charge
M &L For false ceiling with 4 mm thick designer 'E' board fixed on GI grid work with powder coated finish on exposed surface of size 0.60 x 0.60 m consisting of GI angle supported on wall of size 24 mm x 28 mm x 0.7 mm main tee of size 24 mm x 38 mm x 0.7 mm cross tee of size 24 mm x 28 mm x 0.7 mm using porpose made members interlocking to made to shape at 1200 mm c/c fixed with 3mm dia. GI wire suspender and making holes etc. all as directed including two coats of white wash on ceiling after preparation of surfaces and as per manufacture instruction make of grid work : Armstrong/ swastik/ Techno Grid and 'E' board Gypsum or equivalent approved. including taking down old ceiling etc complete as directed. Note :- The rate quoted by the bidder is including necessary scafolding for the work
Powder coated 50 microns extruded aluminium frame for fixed type partition (Standard two panel pattern) made out of powder coated aluminium section of size 63.5 x 38.10 x 1.5mm, comprising of 5mm thick tinted glass inserted in and including necesary jointing cleats, rubber packing, anodised aluminium snap beading complete fixed to floor and wall by means of cadium plated steel screws complete incl taking down of existing partition with all fittings and fixtures all as specified and directed.
S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F Steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded ®
S&F Joist, channel, angle ot tee sections, fixed independently, without connecting plates, etc(cut to ordinary lengths i.e within 20mm of the length indicated quality conforming to Fe 410-W(gde-E-250)quality-A
Supply only Fine aggregate (sand) for sand cousioning
M & L Rubber moulded precast concrete interlocking pavour block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade with glossy finish colour shade complete all as specified and directed by Engr-in-Charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
M&L for two coat of synthatic enamel paint over a coat of primer on new concrete surface including surface preparation of any description (Road side cement concrete kerb stone in ZABRA Pattern) complete all as specified and directed.
M & L Filleting in any position and to any shape in cement mortar 1:4 exc 25 but n.exc 50 Sqcm in sectional area including all mitres, stops, etc.
M&L for PCC 1:4:8 type D-2 (using 40mm gde agg) as in foundation and mass concrete complete as specified and directed by Engr-in-Charge.
M&L PCC 1:2:4 type B-1(Using 20mm graded crushed stone agg) in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Taking down unserviceable main switches, DBs,MCBs bus bars chambers including all fittings and fixtures such as MCBs,isolator, etc complete all as specified and as directed by Engineer-in charge.
Taking down existing unserviceable sub main wirings with PVC conduits / PVC casing-caping and making good disturbed surfaces complete all as specified and as directed by Engineer-in charge.
M & L earthing complete with galvanised steel eath plate electrode 600x600 x6 mm thick, burried directly in ground (earth pit not less then 2.25 mdeep bellow ground level) with top edge of the plate not less then 1.5 m deep below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts,, check nuts and washers of galvanised iron or steel connected to earthing test point as directed and including concrete pit in PCC(1:3:6) type C-1 precast RCC (1:1:5:3) type A-1 cover slab 54x5 cm reinforced with 4 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia TMT bar embedded in precast cover slab funnel wire mens 20 mm bore GI pipe (medium grade) for watering charcoal and salt in altemate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No 3 of SSR part-I complete all as specified and as directed .
All as per item No 44.00 here-in-above but for one exhaust fan point controlled by one switch.
All as per item No 44.00 here-in-above but for one socket outlet 3/2 pin, 5 Amp, point on the same board with other switches.
All as per item No 44.00 here-in-above but for one socket outlet 3/2 pin, 5 Amp, point on the independent board with other switches.
All as per item No 44.00 here-in-above but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket point.
Supply and fix ceiling rose surface bakelite 65x50 mm two to three terminals.
M&L switch piano flush type single pole one way 5 Amps complete all as specified and directed.
M&L Switch Socket Combination outlet, multipurpose, 2 pin 5 amps/3 pin 5 amps controled by one switch 5 amps, flush type complete all as specified and directed.
M&L switch piano flush type single pole one way 15 Amps complete all as specified and directed.
M&L Universal socket outlet with shutter, 5/15 amps controlled by one switch 15 amps, flush type complete all as specified and directed.
S&F and refixing single pole 06 to 32 A rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing andcommissioning, complete all as specified and as directed
S&F and refixing single and neutral 32 to 40 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing andcommissioning, complete all as specified and as directed
S&F inrepair MCB TPN 63 A rating complete all as specified and as directed
S&F in repair factory made board distribution in sheet steel enclosure without bus bar SPN, 2 way, 240 Volts suitable for fixing MCBs.complete all as specified and as directed by Engineer-in charge.
S&F in repair sheet metal enclosure, (for DB's when MCBs to be used), flushed in wall single pole and neutral Double door, 12 way, 240 Volts with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed.
M&L point wiring with 1.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables drawn through and including surface type in PVC Conduits with all accessories complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including suitable size of PVC type rectangular Gang box of suitable module/size, screws for mounting switches, sockets, regulators etc complete for one light/fan/bell point controlled by one ,one way switches as specified and directed.complete all as specified and as directed by Engineer-in charge.
Supply, install, commissioning & testing of Exhaust fan, metal body with automatic back shutter louvers 300 mm sweep, 1400 RPM or more, Air Delivery not less than 1850 CMH, single phase, 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3/2 core of suitable size from ceiling rose to fan in flexible hose and making of suitable sized hole in the wall/existing window/ventillator/other surfaces etc. for fixing of the exhaust fan & making good the disturbed surfaces (if any) complete all as specified & as directed. Make : Havells, Cat No: Ventil Air - DB or techno-commercially equivalent in Usha/Crompton. Note :- (i) The cost of making hole in walls/other surfaces & making good the dsturbed surfaces incl any framework/cement work/wood work/welding work etc. required for proper fixing of the exhaust fan & matching to the existing surface is deemed to be included in the unit quoted rates
Cutting of brick/stone/Wall panels masonary for fixing of exhaust fan or passing of chimney duct and making
Supply and Fixing Wall mounted fans complete with three numbers of blades, operated at 230 V AC Supply of 400mm sweep, min air delivery 100 CFM with service value 6.00 BEE Five star rating with Brushless direct current rating (BLDC) including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size complete all as specified and directed by the Engr-in-Charge . Note : (i) Installed Wall fan's warranty card should be submitted to the Engr-in-Charge. (ii)The cost of making good the disturbed surfaces and matching to the existing/original surface is deemed to be included in the unit quoted rates
M&L sub main wiring concealed type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run o f 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
good to the disturbed surface including painting/colour wash as directed by Engr-in-charge.
S & F LED batten suitble for indoor application 20 W, 4' length , wall mounted with aluminium housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge
S & F in repair for LED light fitting,1x10 watt bulk head luminaries,,6500k CCT etc.complete with all accessories complete all as specified and directed
Supply and fix in repair recess mounted low glare LED panellight 2'X2' size 36 watt white/warm white for armstrong/grid ceiling or similar ceiling mounting system complete prewired using 1.5 Sqmm FRLS PVC insulated (Unsheathed) 3 core copper conductor cable, 1100V grade including taking down old complete all as specified and directed. Make: BAJAJ/Wipro/Crompton/Havells
Excavation in trenches not exceeding 1.5 Mtrs, wide and not exceeding 1.5 Mtrs in depth for foundation, laying of cables etc and getting out in soft/ loose soil complete all as specified and as directed .
Returing, filling in including spreading, leveling, watering and well ramming in layers not exc. 25 cm depth in soil complete all as specified and as directed .
Removing excavated material (soil) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs above the starting point complete all as specified and as directed .
Supply and sperading clean dry (tibba) sand in trenches for cushioning all as specified for cable protection complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat, size 250 mm x 150 mm x 40 mm as mechanical protection to underground cables laying with length of the cable cover equal to the width of the trench
M&L for boring/drilling by machines/manual horizontally under the road in any type of soil without cutting/disturbing the existing road and inserting GI pipe of any size for drawing the cable complete all as specified.(GI pipe shall be measured and paid seperately.
M&L for galvanised steel tube 50mm bore (light grade) laying in road/drain crossing for cable protection pipe complete all as specified and as directed. .
Supply and laying in repair XLPE insulated, armoured, heavy duty electric UG cables with aluminium conductor 1100 volts grade complete including porviding lugs as required as specified and directed for cross-sectional area 10 sqmm 2 core.
All as per item No 74.00 here-in-above but of size 25 Sqmm, 3 1/2 core
Supply, install, LT Bus Bar Junction box (200A rated) of size 0.5 x 0.5 x 0.4 mtr , outdoor canopy type , manufactured by a CPRI approved factory ,floor mounted ,dust and vermin proof ,front and rear operated door with necessarry locking arrangement made of 50 x 6 mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 Hz, 3 Phase 4 wire system and shall be complete with suitable capacity screwed Aluminium bus bar (200 Amp rating) ,suitable size bolts and nuts of thimbles glands, MCCB 4 pole , 415 Volts , 63 Amps, 16 KA -01 No and light indicators complete all as specified and as directed . Note :- earth work, PCC, angle iron work shall be included in quoted rates.
NOTE:- (i)- Quantities are clubbed in BOQ for two Jobs. Item's qty details as per Annexure on Sl. Pg. No. 22 of tender.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
TENDERDOC.pdf
Tender Documents • 3.46 MB
BOQ_833525.xls
BOQ • 2.89 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .