Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.8 L+₹1.6 L (3.86%)Rejected-Finance FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹43.1 L+₹1.9 L (4.66%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹45.0 L+₹3.8 L (9.28%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹49.6 L+₹8.4 L (20.3%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
4 Mar 2025, 6:00 pmClosed
GARRISON ENGINEER I GOS
GE (I) GOS
REPAIR REPLACEMENT OF GI LINES AND LIGHTENING ARRESTORS AND OTHER ELECTRICAL WORKS UNDER GE I GOS
2025_MES_693243_2
8000/101/2024-25/1000/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GOS
As per tender documents
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹80,000
Yes
2 Apr 2025
20 Feb 2025
6 Mar 2025
20 Feb 2025
4 Mar 2025
27 Feb 2025
Amount
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x6mm thick burried directly in ground (earth pit not less than 2.25 m deep below normal ground level, connecting to the Galvanised iron earth lead 32x6mm size, by means of bolts, nuts, check nuts and washers of galvanised iron and 32x6 mm earth lead protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4kg/Sqm) and frame of angle iron 25x25x3 mm with lugs-02 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom 1.5 meter long placed on top edge of earth plate common salt and charcoal filling, test point with fixing arrangements, funnel wire mesh and earth work in hard/dence soil returning filling in and removal of surplus soil to a distance not exceeding 50 m, all as per electrical plate No 5 of SSR-2010 Part-I and connecting to earth test point all as specified and directed.
Supply and Fixing aluminium strip 25 mm x 3.15 mm complete with saddles and fixing screws as roof conductor complete all as specified and directed.
Supply and fix Tubes light grade galvanised of size 32 mm with all fittings and fixed complete for suuporting the air temination rod and protection of GI strip complete all as directed
M & L for Test point terminal block made of gun or phosphorus bronze size 75 x 75 x 25 mm, drilled and secrewed including 3 nos 8 mm dia 25 mm long hex. Head screw including removal old extg unsv one complete all as directed complete.
Supply and fixing of earthing pit cover made out of cast iron painted with black colour with weight upto 3.5 Kg of suitable size complete all as specified and directed
Supply and fixing of earthing pit cover made out of 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4kg/Sqm) with handle of any suitable size as per site requirement complete all as specified and directed
Supply and fixing of concrete earthing pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate complete all as specified and directed
M&L for Galvanised iron strip 32 x 6 mm buried in ground or fixed on walls/poles with fixing arrangement of nut bolt as required complete all as specified and directed
M&L for testing of earth resistance of earthing pit as per IS and prevailing installation standing order by using std tested and calibrated equips as directed, noted down the reading and preparing Earth test register etc, if desired value does not come pouring of salt water by mixing common salt in water and retesting the earthing value, repair/ replacement of UNSV strips,test terminal block,RCC pit cover,funnel,protection pipe, painting to the earthing pit, writting the earthing value and date of testing over the earthing pit cover complete all as specified and directed.(Note:- Repair/Replacement of strips,test terminal block,RCC cover,funnel,protection pipewill be measured and paid under respective schedule)
M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate for copining of pole complete all as directed
Supply and fix procelain insulators suitable for fixing of earthing strip of any size to carry lightning resistance complete all as specified and directed.
M&L for excavation of the existing earthing pit disconnecting the earthing strip from the equipment and keeping in safe custody the earthing plate, GI pipe, earthing pit and cover , refixing the earthing plate with common salt and charcoal filling and fixing of GI pipe refilling of the soil and connecting up to the equipment complete all as specified and directed.
M & L for Cutting and trimming of tree branches 5 mtr all around of any size which is coming over the two/four pole structure of 11 KV line by using required tools and plants incl removing trimmed tree branches. (Note : Each cleaning will be measured and paid separetely)
M&L in repairs danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified.
M & L for removing vegitation, grass, scrubs and bushes growing in Sub station yard along with fancing by mannually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately.
M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard for laying all as directed and specified.
Supply/ Lay dry river sand /m -sand in trenches for cable protection all as directed. Note : Punned thickness only will be measured & Paid
M& L for Brickwork with straight or curved on plan with subclass ‘B’ bricks, exc 6 m mean radius built in CM 1:6 complete all as specified and as directed.
M & L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement water proofing compound complete all as specified and as directed
M&L for plain Cement Concrete 1:3:6, Type C-2 of grade using 40mm graded stone aggregate in foundations, filling and mass concrete, etc. for embedding fencing posts, complete all as specified and as directed.
Supply and fixing FRP fencing made up with using FRP rod 12 mm dia, channel size 50x24x4 mm box section 50x25 mm I Section 38x15x3 mm and square box section 50x50mm in post embedded in plain cement concrete (1:4:8) type D2 using 20 mm graded stone aggrerate (45x45x45cm) including necessary excavation and earthwork at 1.25 m C/C with height of fencing 2 m from GL including entracne gate of size 1mx2m of same material MS aldrop bolt 300mm long , 150 mm size pressed steel handles and 2 Nos tower bolts MS hinges as required etc complete all as specified and directed Make : Syntex or equivalent as approved by GE Note :- Verticle posts and rail section shall be manufactured of fibre glass reinforcement min 45% and formulation of polystrbased thermoset resigns.
Taking out old unserviceable PCC/steel tubular pole 9 mtrs long and supply and fixing Galvanised Octoganoal poles of section length 9 Mtr,top 70 mm bottom 155 mm and thickness 3mm with base plate 260x16 mm of hot dip galvanised 65 micron, with single out reach arm, foundation bolts, nuts, screws and Excavation and PCC work all as specified and erecting in position all as specified and directed including marking of pole number with black paint in yellow circle, complete, all as specified and directed.
M&L in replacement of new generation energy saving and environmental friendly, long, life pressure die cast aluminium housing flood light with PC diffused lens enclusre over LED for glare free light of capacity 120 watts, 240 volts, 50Hz complete all as specified and directed.
M & L for cleaning of Transformer,VCBs,RMUs,Panels,Junction boxes,Bus bar boxes and DG sets located inside the sub stns including removing vegitation, grass, scrubs and bushes growing inside Sub station bldg and roof by mannually / mechanically and keep the sub station bldg neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include all the cosumables and cotton waste, cloth,cleaning solutions etc to keep the sub stn bldg and Equipments neat and clean through out the period of contract and each cleaning will be measured and paid separately.
Supply, fabricate, erect, test and commission in replacement outdoor LT Feeder pillar box totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC Supply, factory made standard design as per electrical requirements to suit power distr sys of minimum 6 out going cable , enclosure fabricated out of 3.00 mm thick MS sheet with front and back done openable, excavation and earth work, PCC foundation etc,with hinged doors and lcoking arrangemetn , air vents, tappered roof, incoming and outgoing cable connections from bottom with compressed cable gland etc as required with and including the following, supplied fitted and connected internally complete 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 400 Amps and neutral rating 200 Amps mounted on non cracting resin type insulators, moulded case circuit breaker Four pole 400 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In complete all as specified
Supply, installation, testing and commissioning of LT panel board, wall mounted type, fitted with nuts, bolt and washers fitted with knob and hinges, fabricated out of 2.00 mm thick MS sheet . LT panel shall be totally enclosed weather proof and verming proof with front opening with IP-54 protection duly powder coated for connection, RYB, insulator complete pre-wired and cable connection with copper conductor wire upto aluminium bus bar including all incoming and outgoing cable connection with suitable size of aluminium lugs/gland complete all as specified and directed by Engr-in Charge and also comprising of the following of suitable size.(i) MCCB 160 A FP, 16 KA - 1 Nos. (Incoming) (ii) MCCB 40A TP, 16 KA, . 03 Nos. (Outgoing)(iii) MCB SPN 32 A, 10 KA -04 Nos (iv) Alumimium bus bars sleeve insulated 200 amps capacity for RYB and 100 Amp for neutral mounted on epoxy insulators-01 Set (v) Indicators RYB - 01 Set(vi) Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses.(vii) Cable entry glands and two nos earthing terminals
Excavation of trenches in any type of soil n.exc 1.5 M wide and n.exc 1.5 M in depth for taking out/laying of pipe lines and getting out forming bottom surfaces to required gradients complete all as specified and as directed.
Returning, filling in and including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed
Removing excavated surplus materials to a distance not exceeding 50 Mtrs and deposited where directed at a level not exceeding 1.5 Mtr. Above starting point complete all as specified and directed.
Taking down unserviceable pipe lines S&F 3-layer PP-R polypropylene random copolymer concealed pipe (PN 16/SDR 7.4) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings, floors or in trenches etc of size 63 mm OD complete all as specified and directed. Make : SFMC/KPT or equivalent in approved by E-in-C
All as per Item No. 30 above but of size 50 mm OD.
All as per Item No. 30 above but of size 32 mm OD.
All as per Item No. 30 above but of size 25 mm OD.
S&F in repair of PP-R gate valves(brass inlet) as per requirement of size 63 mm OD complete all as specified and directed. Make : SFMC/KPT or equivalent in approved by Engineer -In-Charge.
All as per Item No. 34 above but 50 mm OD.
All as per Item No. 34 above but 32 mm OD.
All as per Item No .34 above but 25 mm OD.
S&F in repair of PP-R male threaded coupling (brass inlet) as per requirement of size 63mm OD complete all as specified and directed. Make: SFMC/KPT
All as per Item No. 38 above but 32 mm OD
All as per Item No. 38 above but 25 mm OD
S&F in repair of PP-R Female threaded coupling (brass inlet) as per requirement of size 63mm OD complete all as specified and directed. Make: SFMC/KPT
All as per Item No. 41 above but 32 mm OD
All as per Item No. 41 above but 25 mm OD
S&F in repair of PP-R Union (brass inlet) as per requirement of size 63mm OD complete all as specified and directed. Make: SFMC/KPT
All as per Item No. 44 above but 50 mm OD.
All as per Item No. 44 above but 32 mm OD.
All as per Item No .44 above but 25 mm OD.
M & L in replacement and making connection of PP-R distribution branch with PP-R mains of size (16 to 40mm) by providing and fixing tee including cutting and making fusion joint etc as per required at site.
M & L in replacement and making connection of PP-R distribution branch with PP-R mains of size (50 to 75 mm) by providing and fixing tee including cutting and making fusion joint etc as per required at site.
Boring across the road/hard surface with machanical boring equipments not less than 80 mm bore dia all as specified and directed.
S&F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 1 20mm-210gms./ 25mm-455gms) of size 20 mm dia complete all as specified and directed. Make : Prayag/Polytuf
All as per Item No 51 above but 25mm dia
Taking down 0ld unserviseable Run lead joint and M&L for run lead joint of size 80 mm dia complete all as specified and directed
All as per Item No 53 above but 100 mm bore.
All as per Item No 53 above but 150 mm bore.
All as per Item No 53 above but 200 mm bore.
All as per Item No 53 above but 300 mm bore.
All as per Item No 53 above but 400 mm bore.
M & L for mechanical type joint made of MS sheet of size 6/8 mm thick along with rubber gasket nuts bolts and washers suitable for 80 mm bore dia of CI/DI pipe. Including Taking up or down old u/s joint all as specified and directed.
All as per item No :59 above but 100 mm bore dia
All as per item No :59 above but 150 mm bore dia
All as per item No :59 above but 300 mm bore dia
All as per item No :59 above but 400 mm bore dia
M& L for MS/CI/DI fittings up to 300mm bore such as collar, bends (any type radius, any angle, double end socketted or double flanged or spigot & socket, tail pieces (all socketed or all flanged with an equal & other end tapering bellmouth or flanged plates, connecting pieces straight (both end flanged or socketed of socket & flanged & spigot ends or bellmouth tailpieces ( one end flanged & other end spigot or socket or tapering as bell mouth or flanged ) caps blank flanges heavy duty suitable for mechanical joint/flanged joint with and incl taking down old fitting of any type and any size complete all as specified and directed.
Attending emergency breakdowns/ complaints of damaged water supply lines of 400mm dia DI Pipe line from bada madhvapur to kaliapally pump house restoration of water supply by stopping the leakage occured by deputing skilled /semi skilled man power for smooth functioning of water supply , complete all as specified and directed by Engineer-in-Charge . Note : Up to 0.5Cum of the earth work shall be included in the job & more than 0.5 Cum shall be measured and paid separately. (b) The complaint /breakdown shall be rectified by the contractor within 24 Hours.Any delay thereafter,recovery at double the rate quoted per job shall be deducted from the dues of contractor by the Engr-in-charge without any notice. (c) welding work, tyton joint, T&P and MS plate as required at site deemed to included the unit rate quoted.
All as per Srl item No 38 above but Bore of pipe line 300 mm dia from kaliapally pump house to main pump house GMS
M & L for taking out sluice valves of dia 300mm, transporting to workshop and back and carrying out repairing, refacing, grinding, replacement of gland packing and refixing back to its original position including repacking of stuffing box of sluice valve spindle, replacement of nuts and bolts all as specified and as directed.
All as per Item 67 above but of size 400mm dia
S&F in replacement of Air release valve 100 mm bore including jointing materials,rubber gasket suitable size nut bolts and washer etc complete all as specified and directed. Make :Upadhay/Zoloto/Kirloskar or equivalent
Attending electrical complaints at Badamadhavpur pump house Identifying defect and rectifying the minor defect for smooth functioning of machinery and cleaning LT Panel of 415 Volts 3 phase bus bar chamber with electrical connections, removing all the bus bar links from the panel, checking its condition. Cleaning the total bus chamber with CTC solution on complete bus bar. Checking all the connections, tightening the nuts, bolts & thimbles of in-coming/out-going system complete incl replacement of defective rusted bolts & nuts with new ones all as specified and directed.
Supply only Calcium hypo chlorite Based granular having chlorine content of 65 % Disinfectant in 45kg packaging plastic drum for water treatment complete all as specified and as directed by Engineer-in-Charge.
R J ENTERPRISES (BID ID -3254349)
M/S. KISHAN ENGINEERING (BID ID -3253947)
M/s Bapujee Builders and Traders (BID ID -3254404)
M/s Ats Electricals (BID ID -3254344)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .