Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 CrAccepted-AOC | ₹25.9 Cr | L1 | Accepted-AOC Being L1 and reasonable |
| 2 | L2₹29.2 CrRejected-Finance | ₹29.2 Cr | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹30.5 CrRejected-Finance | ₹30.5 Cr | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹37.2 CrRejected-Finance | ₹37.2 Cr | L4 | Rejected-Finance Being other than L1 |
Tender Value
₹31.1 Cr
EMD Value
₹15 L
Closing Date
11 Mar 2025, 6:00 pmClosed
Chief Engineer (CG) Visakhapatnam
Office of HQ Chief Engineer (CG), Near Varma Complex, Muralinagar, Visakhapatnam-530007
CONSTRUCTION OF DEF MD ACCN WITH ALLIED AMENITIES UNDER PHASE II AT MANICKTALA, KOLKATA FOR CGRHQ NE AND OTHER UNITS AT KOLKATA UNDER GE I CG and N KOLKATA
2025_MES_695276_1
CE (CG) /VIZ/KOL(MNK)/TOKEN -17 OF 2024-25
Open Tender
Civil Works
600 days
Manicktala
As per NIT
9 documents required · 9 mandatory
₹3,000
GE (I) (CGN) Kolkata
₹15 L
Yes
1 May 2025
28 Jan 2025
18 Mar 2025
28 Jan 2025
11 Mar 2025
25 Feb 2025
Amount
Schedule "A" Part – I to Schedule "A" Part – XX NOTE: Schedule "A" Part – I to Part – XVIII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only and for Items of Part XIX & XX Bidders shall insert unit Rate of each items of work in Green coloured field under Column - 6 only.
Lump Sum price worked out by the contractor for "BUILDINGS & STRUCTURES" as listed in Schedule 'A' Part - I
Price worked out by the contractor for "EARTHWORK AND SITE CLEARANCE ", as listed in Schedule 'A' Part - II
Price worked out by the contractor for "INTERNAL WATER SUPPLY" as listed in Schedule 'A' Part - III
Price worked out by the contractor for "INTERNAL ELECTRIC SUPPLY" as listed in Schedule 'A' Part - IV
Price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule 'A' Part - V
Price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY "as listed in Schedule 'A' Part - VI
Price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule 'A' Part - VII
Price worked out by the contractor for "AREA DRAINAGE"as listed in Schedule 'A' Part - VIII
Price worked out by the contractor for "ROAD/ PATH/ CULVERT as listed in Schedule 'A' Part - IX
Price worked out by the contractor for "CHAIN LINK FENCING" as listed in Schedule 'A' Part - X
Price worked out by the contractor for "FIRE FIGHTING EXTERNAL" as listed in Schedule 'A' Part - XI
Price worked out by the contractor for "FIRE FIGHTING INTERNAL" as listed in Schedule 'A' Part - XII
Price worked out by the contractor for "LIGHTNING PROTECTION" as listed in Schedule 'A' Part - XIII
Price worked out by the contractor for "HOT WATER SUPPLY" as listed in Schedule 'A' Part - XIV
Price worked out by the contractor for "TELEPHONE/ LAN/ TV CONDUIT" as listed in Schedule 'A' Part - XV
Price worked out by the contractor for "DG SET" as listed in Schedule 'A' Part - XVI
Price worked out by the contractor for "LIFT" as listed in Schedule 'A' Part - XVII
Price worked out by the contractor for "PILE WORK" as listed in Schedule 'A' Part - XVIII
Schedule "A" Part - XIX [Miscellaneous Items]
INTERNAL WATER SUPPLY
S&F two way bib cock 15mm bore with flange cast copper alloy chromium plated fancy type screwed for iron popes brass ferrule etc. complete all as specified and as directed.
S&F wall mixer CP 15 mm dia for mixing hot & cold water including tap screwed down for pipe and fixed to wall complete all as specified and as directed.
INTERNAL ELECTRIFICATION
S & F LED bulb 9 Watt lumen not less than 900 Lumen complete all as specified and directed
S&F modular white cover plate with frame 12 way
Design, Supply and Commission integrate and maintain the Advanced Metering Infrastructure (AMI) comprising of following for Single Phase Meter:- (a) Supply, installation, commissioning of Smart Meters of different makes (not more than 33% of a particular make to ensure interchangeability at a later date as per BIS 16444 with communication technology including GPRS/RF Mesh or Canopy/Hybrid (RF + GPRS)/Any other advanced technology as per CEA/TRAI regulations. (b) Supply/Planning/Setup/tuning of RF Mesh communication infrastructure including Network Management (NMS) & Head End System for the project area. AMI Software and associated equipment's should be capable of handling at lease 152 Number of Meters of different makes as per BIS 16444 with 25% expansion without any additional infrastructure and cost implication to MES. (c) Supply and setup of Meter Data Management (MDM) (d) Integration of different devices of different makes/equipment/software's covered in scope of this project with each other as per functional requirements, including water charges, furniture and license fee.system. (e) Integration/Interface of the AMI system with application systems like Metering/Billing/collection. Interface has to be provided in the proposed solution to upload and process meter date from these systems. (f) Server for Housing and management of supplied software application with standby server. (g) Planning, deployment & tuning of communication system including Cellular network (if required) to meet the performance requirements. (h) Business Intelligence, Analytics and Reporting. (j) Training and knowledge transfer. (k) All expenditure including periodic charges of telecom operator from installation till completion.
Supply, Installation of 400A, 4P MCCB capacity End Feed Unit for existing Rising Main, made of 1.6mm GI enclosure with C&S make 25kA, 4P TM release MCCB
Supply, Installation of 63A Tap off box with 63A, 4P,25 KA MCCB capacity TPN Tap off box for existing Rising Main, made of 1.6mm GI enclosure with 4P, 25 kA TM Release MCCB.
S & F blank plate PVC in lieu of MCB, modular switch,Socket etc
Supply ,Installation of 400A, 4P, 36kA compact sandwich bus trunking/rising main including all accessories as per site requirement Rising Main,aluminium conductor (3 phases +100 %Neutral +50% integral GI earth) 4 Nos Al bus bars having current density of 130A / Sq. CM at nominal current ratings and 2 nos. of suitable external aluminium earthing strips, System voltage 415 Volt, AC supply, IP 65, rated frequency 50 / 60Hz, made of 1.6 mm thick sheet GI enclosure duly painted with powder coating (RAL-7032), with provision of tapping at every floor etc. Compliance standard:IEC-61439 (Part 1&6) & IS- 8623 (Part 1&2),Independent
EXTERNAL WATER SUPPLY
M&L for 100 mm dia ductile iron pipes with flanged ends centrifugally cast Class K-9, with necessary gaskets, nut bolts and other accessories in any length, laid in trenches complete all as specified and directed by Engr-In-Charge.
M&L for 150 mm dia ductile iron pipes with flanged ends centrifugally cast Class K-9, with necessary gaskets, nut bolts and other accessories in any length, laid in trenches complete all as specified and directed by Engr-In-Charge.
M&L for DI specials like Bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs for DI pipe upto 100mm bore as directed by Engr-in-Charge.
S&F MS Flange suitable for 80mm bore steel water tubing including with necessary GI Nuts bolts and gaskets complete including welding/threading to the pipe complete all as specified and directed.
Supply and fix for 100 mm dia D.I. resilient (soft) seated gate valve with pocket less body, ss stem (AISI 410), epdm coated di wedge 100% vaccum tight design with toroidal sealing rings & over 250 micron epoxy coating in PN16 designed to BS:5163/IS:14846 non-rising stem type with hand wheel operation complete all as specified and as directed.
Supply and fix CI foot valve conforming to IS 4038, 150 mm (4") dia all as specified and as directed.
Supply and fix 100 mm (4") dia DI resilient seated non-return valve, flanged end in swing type design with EPDM door and with over 250 micron epoxy coating including all necessary items complete all as specified and as directed.
Supply and fix Air release valve, 50 mm (2") dia with all necessary fittings all as specified and as directed.
Construction of brick masonry (full brick thick wall ) valve chamber, of 1050x1050x950mm size of internal dimension, PCC work with (1:4:8) type D2 . 150mm thick (using 40mm grade stone aggregate) for foundation complete with 3.00mm thick MS sheet cover and frame of MS angle iron 40x40x5mm with locking arrangement and painting with one coat of red oxide primer and two coats of synthetic enamel paint all as specified shall be plastering to internal and exposed surfaces of the chamber, in CM(1:4) 15mm thick and PCC coping (1:2:4) type B-1, 50mm thick all as specified.
Supply, installation, testing and commissioning of Horizontal Centrifugal Pumping set split case type with side suction and side discharge, suitable for operation on 2850/2900 RPM, comprising of , centrifugal pump capable of delivering 12.88 LPS at 70 Meter Head, 2850/2900 RPM directly coupled with TEFC squirrel cage induction motor 3 Phase, 415 Volts, 50 Hz AC supply IP 55 Protection, of HP/Wattage suitable to drive the pump, suitable for operation at up to 50 degree centigrade, Class "F" insulation, with temperature rise limited to Class "B" confirming to IS: 325, complete pump and motor assembled with base plate , coupling, coupling guard and foundation as per OEM's specifications complete with suction pipe in suitable size and specifications as per OEM recommendations upto 3 meters in length, header and foot valve etc . Casing shall have axial suction and top centre line delivery. Impellers shall be of enclosed type. Shaft shall be supported with antifriction bearing, grease lubricated all as specified and as directed.
Supply, fix, installation and testing Altoch dosing system model ADS-PRO 153120 AP with necessary fitting arrangement to waterline. Item description: 1. Receptable for power-free-automatic water sanitizer/ conditioning treatment station with proportional dosing arrangement with following attachments:- (a) Water inlet valve (b) Overflow valve (Rubber guard included) (c) Outlet valve for standalone gravity flow (d) Outlet valve for automated flow (e) Drain valve (f) Level controller (g) Level gauge (h) Detachable grouting bas with rubber buffer (j) Custom cover synchronous fixing arrangement (k) Material of construction : Non-metallic thermoplastic (l) Maximum Temperature : 45.C (m) Capacity : 100 liters (n) Shape : Cylindrical (p) Compatibility : Stequa 411 AE Refill/Prefill-Total refill
2. Custom cover for power-free automatic water sanitizer / conditioning treatment station with proportional dosing arrangement with following attachments: Refill Cavity Lids (13) In-built Level Switch & Processor ½ inch Processor Outlet & Processor Inlet connections Flexible Connecting Duct Material of construction: Non-metallic Maximum Temperature: 45°C Shape: Circular Compatibility: Stequa 411 AE Refill / Prefil - Total refill Note: Necessary cutting/fabrication work deemed included in the rate.
Supply only STEQUA 411 AE REFILL Item description : Chlorine tablets contained in plastic cylindrical sealed disposable sanitizer refill for disinfection of drinking water with arrangement for controlled release of disinfectant in water, suitable for operation through recommended dosing system. (a) Replacement indication: Visual & weight variation (b) Water contact orifice design : Sealed when dry, exposed upon immersion. (c) Operation type: Non contact, Non inhalatory (d) Cylinder Dia : 2.5 inches +/- 0.5 inches (e) Cylinder height : Minimum 10.00 inches +/- 0.5 inches (Note: 01 Set consists of 25 Pcs)
Delete : Line 1 to 8 in BOQ and add description as given below Item for item 41:- Supply, Installing, testing and commissioing of LT Panel factory made indoor type as per IEC 61439 Part 1&2 (Switchgear OEM Type Tested design) with following minimum thickness- Load bearing member/ Doors-2 mm, Non-load bearing/ Internal partitions-1.5 mm, Glandplate/ Base channel-3 mm, Board floor mounted, dust and vermin proof, 3 Phase 4 wire with rated operational voltage 415V, rated insulation voltage of 1000V Impulse withstand of 12Kv and minimum internal Arc with-stand of 65KA, 500 m/sec as per IEC61641, weather proof, with separate hinge door for each compartment with operating handle & locking arrangement with door common openable (screwed/lockable), grouted in PCC 1:2:4 complete. Painting as per OEM defined 7 Tank process with epoxy powder polymerized at high temperature and aluminiumbusbar (TPN) suitable double compression aluminium cable glands with the following accessories. INCOMER (i) MCCB 125 Amp 4 pole 25 KA with microprocessor based release - 01 No OUTGOING (i) MCCB 63 Amps 4 pole 16 KA with microprocessor based release - 04 Nos (ii) Automatic Star Delta Starter - 02 Nos (iii) MCB TPN 32 Amps 'C' Series - 01 No (iii) MCB DP10 Amps 'C' Series - 02 Nos (iv) 200 Amps capacity copper bus bar of suitable size and required length (equal size for phase and neutral) and fixed on 04 Nos (v) SMC/DMC/porcelain insulators - 04 Set. (vi) Digital ammeter 0-200 amps -01 No with suitable CTs (vii) Digital voltmeter of 0-500 volts-01 No (viii) LED indicator lamp RYB (set of 3)- 02 set. complete all as specified and as directed
S&F PVC insulated 3 core cable flat flexible suitable for centrifugal pump set 1100 volts grade with standard copper conductor cable of size 10 sqmm complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply, Installation, testing & commissioning of fully type tested HT 11KV, 25 kA, Line VCB panels switchboard consisting of 3 outgoing 630 Amps VCB extendable type to be integrated with existing VCB . VCB panel indoor type totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontal isolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. The switchgear panel shall be of sheet steel construction with Aluminum Zinc not less than 2.5mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall totally dust and vermin proof. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2, C2duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker shall also be the manufacturer of the Vacuum Interrupter, Relay. Panels shall be with temperature measurement sensors at all ciritcalpoints Medium voltage cable connection &Busbar joints/ Connections for local investigation and local monitoring. HMI shall be provided for condition monitoring data and alarms as per OEM recommendations. The switchgear and control gear panels shall be of the fully arc proof for 25kA for 1 Sec. "Bus bar rating to be 120% of contionuous current Inbuild power pack and battery bank for 24 V DC to be provided for auxiliary supply. Relay shall be Microprocessor based Numerical Relay Communicable type in line with IEC 61850 Protocol and RS-485 port comprising of three over current , one earth fault protection relay with high set for both phase & earth and with fault memory equivalent to P3U30 of M/s Schneider or equivalent, universal auxiliary supply, Master Trip Relay, Trip Circuit Supervision relay ,Digital Multifunction meter with RS-485 port with Class 0.5 with copper wound double ratio double core Current Transformer, MFM 0.2 class, Power Pack Complete all as specified and as directed . Note: Incoming shall be with PT, Transfomer Outgoing shall be Differential relay & Annunciator 12.
Relay Specifications a. MIMIC display with single line representation and switch gear controls shall be possible through the MIMIC. b. The device shall support following communication protocols: Native IEC 61850, IEC 60870-5-101, IEC 60870-5-103, Modbus TCP, Modbus RTU, DNP 3.0, SPA-bus communication. c. Relay shall have front USB for connecting to PC. d. Relay shall have conformal coating to withstand harsh environment. e. Relay shall support PRP/RSTP redundancy communication protocol on RJ45/ FO. f. Relay shall have web server (web HMI) feature to monitor and control using LAN. g. Relay shall have minimum 2000 events. h. Relay shall support SNTP time synchronization. i. Relay shall support customer defined programmable logic. j. Relay shall have minimum 8 programmable LED. "k. Relay shall have disturbance recorder with settable sample rate from 32/cycle up to 1per minute and shall support virtual simulation through which protection functions and logic testing can be achieved without any separate software. l. Phase overcurrent (50/51),Directional phase overcurrent (67),SOTF Switch on to fault (50 HS),Current unbalance (46),Thermal overload (49),Earth fault (50N/51N),Directional earth fault (67N), Undervoltage (27),Overvoltage (59), Zero sequence voltage protection (59N), Frequency (81), directional power (32), auto reclose (79), Circuit breaker failure (50BF),Cold load pick-up and magnetising inrush, Programmable stages (99),Synchro check (25),CB wear. m. The relay shall have 4CT and 4 VT inputs. n. The relay shall be provided with at least 16 digital inputs and 8 digital out puts and 1 self-supervision output. Make: EASERGY P3U30 of Schneider or Equivalent makes of ABB/siemens.: Including connections and accessories suitable for 3*400Sqmm 11KV Cable Including connections and accessories. Complete intra and inter panel wiring including control wiring for connecting all the MFMs etc as per OEMs recommendation is included in the rate quoted and along with any other accessory to make the 11kV panel functional with the existing system
M&L for provision of integration of VCB set (as mentioned at Item No 01 above) to the existing VCB with suitable size of bus bar links, gaskets, nut bolts all other necessary accessories including all fabrication in existing VCB all as specified and as directed.
Supply and installation Compact Secondary Substation (CSS) comprising to following parameters: - (a) Sheet steel housing with corrosion resistance and all side openable hinged door and lock and key arrangements. (b) Steel parts are tested as per IS 6988. (c) Engineered for smooth air flow for natural cooling. (d) No access to High voltage parts. (e) GI strip earthing for all LV and HV equipments as per laid down policy. (f) Separate earthing for lightening protection and lightening spike etc. (g) Separation steel sheet wall for RMU/Transformer/LT panel (h) Heave lifting lugs with all equipments load. (j) Slopped roof. (k) Necessary danger plates outside of the CSS. (l) Necessary HT and LT cable/Earth strips opening.
(m) RMU commissioning of SF-6 insulated Ring Main Unit taps incoming, three outgoing (isolators) and one metering module (CVCM) with necessary CTs and PT, comprising the following :-(Complete unit is to be installed inside CSS, protection accessories , Enclosure : Metal Clad, IP-54 Protection. Protection Relay : Self Powered Alfa numeric LCD display type. Internal arc tested for 1 sec , Fully compartmentalized sheet steel enclosure with automatic safety shutters , GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:- Rated Voltage - 12 KV , Rated Frequency - 50 Hz., Rated continuous current rating - 630 Amps., Rated Interrupting Current - 21 KA., Rated making current for VCBs- 52 KA., Rated making current for Isolators - 62 KA., Rated short time current for 3 sec - 26.3 KA , Operating duty - 0 - 0.3 sec - CO 3 min - CO, Impulse withstand voltage - 75 KV, Bus bar rating - 120% of continuous current., Operation: Spring closing mechanism - DC motor operated with 24 volt supply , Breaker Closing - Manual & Electrical through TNC switch, Shunt Trip coil - 24 V DC Safety Interlock Locking facility - Required.,Breaker panel indication - ON (Red) OFF (Green), Accessories : Mechanical counter ,Space Heater with Thermostat , Fuse and ON/OFF Switch, Aux relays for remote trip/indication for PC interface etc , cubicle illumination lamp LED 9 watt retrofit type 230 V AC , T-N Switch , Anti pumping contactor etc., Mimic Diagram : An operating mimic diagram shall be provided on the front side of each cubicle. Note :- Circuit breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM. The installations, calibration and testing of SF-6 circuit breakers will be conducted in the presence of authorised representative of OEM by the Contractor.Battery bank with charger for RMU is included in the item rate and rating of battery as described by OEM.
(n) Transformers 400 KVA copper wounded dry rasine cast distribution type 6 KV/433V, 3 phase, 4 wire LT output, 50 Hz, AN, Dn11, suitable for indoor installation, with offload tap changer with steps ±2.5% up to ±7.5% on HT side all technical specification comprising to IS 1180 (Part-I&II), with all necessary standard fittings and accessories complete after necessary testing after completion with the following specifications: -
Standard KVA rating: - 400 KVA,Primer Voltage: - 6KV/433V AC, Secondary Voltage: - 433 V AC,Neutral earthing should be solidly earth system, Frequency: - 50 Hz with ±3% tolerance, Vector Group: - DYn11,Percentage impedance: - 5% at 75 deg C (subject to IS tolerance),Average temperature rise shall not exceed to 65deg C and max temperature rise of the windings shall not exceed to 115 DegC.,The core shall be of High grade Cold Rolled Grain oriented (CRGO) annealed steel lamination, having low loss and good grain properties, coated with "C" class grade insulations, bolted together firmly to the frames to prevent vibrations and noise.,HV and LV coils should be with electrolytic copper windings, with "C" class grade insulation on HV windings and necessary spacers and air duct for cooling.,The losses at the rated voltage should be within the specified limit as per IS-1180,The transformer enclosure should be with robust construction and shall be built of electrical welded MS sheet wire mesh or perforated sheet for ventilation, with lifting lugs, pulling lugs, top cover fixing bolts, rollers and enclosure base channels.
S & F Cast Iron Route marker for HT Cable line as per IE rules including foundation work all as specified and as directed
Supply, Installing, testing and commissioing of LT Panel factory made indoor type as per IEC 61439 Part 1&2 (Switchgear OEM Type Tested design) with following minimum thickness- Load bearing member/ Doors-2 mm, Non-load bearing/ Internal partitions-1.5 mm, Glandplate/ Base channel-3 mm, Board floor mounted, dust and vermin proof, 3 Phase 4 wire with rated operational voltage 415V, rated insulation voltage of 1000V Impulse withstand of 12Kv and minimum internal Arc with-stand of 65KA, 500 m/sec as per IEC61641, weather proof, with separate hinge door for each compartment with operating handle & locking arrangement with door common openable (screwed/lockable), grouted in PCC 1:2:4 complete. Painting as per OEM defined 7 Tank process with epoxy powder polymerized at high temperature and aluminiumbusbar (TPN) suitable double compression aluminium cable glands with the following accessories.
INCOMER (i) MCCB 400 Amp 4 pole 36 KA with microprocessor based release - 01 No OUTGOING (i) MCCB 160 Amp 4 pole 25 KA with microprocessor based release - 03 Nos (ii) MCCB 63 Amp 4 pole 25 KA with microprocessor based release - 01 No (iii) 600 Amps capacity copper bus bar of suitable size and required length (equal size for phase and neutral) and fixed on 04 Nos (iv) SMC/DMC/porcelain insulators - 04 Set. (v) Digital ammeter 0-100 amps -01 No with suitable CTs (vi) Digital voltmeter of 0-500 volts-01 No (vii) LED indicator lamp RYB (set of 3)- 02 set. complete all as specified and as directed
Supply, Installing, testing and commissioing of LT Panel factory made indoor type as per IEC 61439 Part 1&2 (Switchgear OEM Type Tested design) with following minimum thickness- Load bearing member/ Doors-2 mm, Non-load bearing/ Internal partitions-1.5 mm, Glandplate/ Base channel-3 mm, Board floor mounted, dust and vermin proof, 3 Phase 4 wire with rated operational voltage 415V, rated insulation voltage of 1000V Impulse withstand of 12Kv and minimum internal Arc with-stand of 65KA, 500 m/sec as per IEC61641, weather proof, with separate hinge door for each compartment with operating handle & locking arrangement with door common openable (screwed/lockable), grouted in PCC 1:2:4 complete. Painting as per OEM defined 7 Tank process with epoxy powder polymerized at high temperature and aluminiumbusbar (TPN) suitable double compression aluminium cable glands with the following accessories.
INCOMER (i) MCCB 63 Amp 4 pole 25 KA with microprocessor based release - 01 No OUTGOING (i) MCCB 40 Amp 4 pole 16 KA with microprocessor based release - 09 Nos (ii) MCB DP 10 Amps-01 No (iii) 100 Amps capacity copper bus bar of suitable size and required length (equal size for phase and neutral) and fixed on 04 Nos (iv) SMC/DMC/porcelain insulators - 04 Set. (v) Digital ammeter 0-100 amps -01 No with suitable CTs (vi) Digital voltmeter of 0-500 volts-01 No (vii) LED indicator lamp RYB (Set of 3)- 02 set. complete all as specified and as directed
Supply & laying bricks (sub class-'B') laid in trenches as LT cable protection with width equal to the length of bricks complete all as specified and as directed.
Supply and Fix Octagonal/Conical pole, 7M in length, single section, with Top dia 70mm, Bottom dia 130/135mm, thickness 3mm, base plate size (225X225X16)mm, with 4X20mm nut bolts, Hot deep galvanized 65micron, BSEN 10025-S355J0 or equivalent grade steel and base plate as per IS 2062, maximum wind speed resistance 160KM/Hr, with Base as per OEM recommended design duly bolts grouting 04 Nos all as directed by the Eng-in-Charge.
Supply and fix outdoor type cable junction box made of PVC complete with knockout for cable entry and 04 nos connectors, and 01 no of 5A SP MCB all as specified and as directed.
Supply and Fixing LED street light fittings 70W on poles /walls and including necessary GI brackets made with 40 mm dia light grade GI pipe with necessary clamps and nuts bolts suitably bended and up to 1.40 M length all as conforming to the following parameters: (i) System watt/Lumens: - Not less than 100 watts (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - IP 65/66 (iv) Front cover: - Toughened Clear Glass (v) Mounting: - Suitable for pole mounting with bracket arm , Mounting height- 5.50m to 6.50 m from GL. (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt.
(ix) Colour temperature (K): - Not less than 5700 (x) Colour Rendering Index (CRI): - Not less than 74 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattern- Asymmetrical driveway (xiii) Control gear: - inbuilt electronic driver with APFC, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 5KV (xv) Heat Sink: - As per OEM's design (xvi) (a). Bidder has to compulsorily submit the LM-79 and LM-80 and third party NABL accredited lab test report conforming of technical specifications and consolidated lab report for the offered LED has to be structured in the same sequence.
Supply and fix LED bollard light in 9 W in warm white colour with IP 65 protection with all fittings complete all as specified and as directed.
M&L for twin LED aviation obstruction light luminaire, integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete all as specified and directed.
Supply, laying & testing PVC insulated, PVC sheathed electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm, 3 core, 1100 Volts grade (for street lights) all as specified and as directed.
ROAD / PATH / CULVERT
M & L for Road studs/ Cat eye the body of stud is made of ABS material with two reflecters fitted in the body. The road stud is dynamically designed so that it can bear load upto 25 Tons and its impact strength is about 230KN weight of stud is 130grms. Body colour yellow with swareflex beads of size 100mmx19mm fixed on road by nail at intervals as directed by Eng-in-Charge.
M & L for thermoplastic road marking paint, white or golden yellow, conforming to BS-3262 applied on road/pavement as in lines, dashes, arrows, letters etc, 10/15 cm in width & of thickness not less than 2mm, with and including combination of retro-reflective glass beads 250-300 gm/ Sqm all as per manufacturer's instructions complete all as specified & directed.
S & F Solar road studs aluminium alloy shell size 125x125x25mm with protection glass on two sides Model No. SE - SRLS 7501 of Shakti or equivalent, including preparation of road surface fixed with adhesive complete all as specified & fixing as per manufacturer instruction.
SEWAGE DISPOSAL
M & L for RCPC Manhole cover (32'') 25 MT (800 mm x 165 mm ) .
CHAINLINK FENCING
S&F PVC coated chain link fencing and complete all as specified and directed by GE. The mess size of chain link fencing shall be 50mmX50mm, the bare size of chain link wire shall be 4mm and after PVC coating the resulting diameter shall not be less than 5.5mm. The PVC coating shall be made of virgin PVC granule i.e. it should not be recycled. The colour of PVC coating shall be approved by GE. The chain link fencing shall be fixed with bolts, nuts and washers to MS angle or plate section complete all as specified and as directed.
TELEPHONE /LAN/ TV
S & F of TV socket outlet one module complete all as specified and as directed.
S &L cable TV Splitter 4 way O/G with 1-way I/C compete including mounting inside PVC box of suitable size flushed to wall all as specified and as directed.
M & L coaxial cables with electrolytic grade solid bare copper conductor, gas injected physical polyethylene foam insulation, with laminated aluminium tape and AI wire braid, jelly flooded and PVC jacketing in Black colour drawn in conduit and connecting and testing complete for type RG-59 cable all as specified and as directed. Note : PVC conduit and accessories shall be measured and paid separately.
EXTERNAL FIRE FIGHTING
Supply, Installation, Testing and Commissioning of Electric Driven Main Fire pump/Sprinkler pump suitable for auto operation & consisting of following: complete in all respect as required. Horizontal Split casing type, centrifugal, multistage, pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq. cm. at highest and farthest outlet at specified flow of 2280 LPM at 70 Mtr. head confirming to IS 12469-1988.Suitable HP squirrel cage induction motor, TEFC synchronous speed 1450 RPM (with permissible slip), suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-' F' insulation, confirming to IS-325-1978Common base frame fabricated out of M.S channel of suitable size, flexible coupling, coupling guard, foundation bolts and pressure gauge with valve etc. Suitable cement concrete foundation (minimum 6" above from ground floor) duly plastered, with anti vibration pads etc. complete as per manufacturer's design & standards and as per detailed specifications. Make- Lubi,/Wilo/Grundfoss/Kirloskar
Supply, Installation, Testing and Commissioning of Diesel Engine Driven Sprinkler Pump suitable for auto operation and consisting of following: complete in all respect as required. Horizontal Split casing type, centrifugal, multistage pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2850 LPM at 100 Mtr. head confirming to IS 12469-1988.Suitable HP 1500 RPM, 4 stroke, cold starting type Diesel Engine with Heat Exchanger confirming to relevant BIS & IS Standards, complete with all required accessories / system, fuel oil filter, lubricant oil pump with filter, 2 Nos. starting batteries of 180 AH capacity each with suitable angle iron stand, engine starting panel having all the controls meters, gauges, tachometer, hour meters, starting switch with keys for manual starting, auto starting mechanism, 24 Volts electric starting equipment, Diesel Tank for 8 hrs continuous running of diesel engine, having minimum capacity of 200 Ltrs. (tank made out of 3mm thick M.S. Sheet with filling Cap, drain Cock, diesel indicator duly mounted on M.S. angle) exhaust pipe extended upto 1 mtr. outside pump house, duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, exhaust residential silencer, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S. fabricated Common base frame, flexible coupling, coupling guard, foundation bolts and pressure gauge with valve etc. Suitable cement concrete foundation (minimum 6" above from ground floor) duly plastered, with anti vibration pads etc. complete as per manufacturer's design & standards and as per detailed specifications. Make- Lubi/Wilo/Grundfoss/Kirloskar
Supplying, Installation, Testing and Commissioning of Electric Driven Pressurization Pump (Jockey Pump) suitable for auto operation and consisting of following: complete in all respects as required.Horizontal type, centrifugal end suction type pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal, gland packing and flow of 180 LPM at 70 Mtr. head confirming to IS:12469-1988.Suitable HP squirrel cage induction motor TEFC type 2900 RPM suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 class of protection for enclosure, horizontal foot mounted type with Class -'F' insulation, confirming to IS:325-1978.Common base frame fabricated out of M.S channel of suitable size, flexible coupling, coupling guard, foundation bolts and pressure gauge with valve etc. Suitable cement concrete foundation (minimum 6" above from ground floor) duly plastered, with anti vibration pads etc. complete as per manufacturer's design & standards and as per detailed specifications. Make- Lubi/Wilo/Grundfoss/Kirloskar
Supply and laying multistrand single core flexible copper cable of size 95 sqmm all as per IS- 8130 and as directed.
Supply and laying multistrand 3 core flexible copper cable of size 10 sqmm all as per IS- 8130 and as directed.
S& F CI foot valve 200 mm with GM working parts as per IS-4038 including all connecting fittings with gasket complete all as specified and as directed.
S& F CI foot valve 100 mm with GM working parts as per IS-4038 including all connecting fittings with gasket complete all as specified and as directed.
Supply and fix 150 mm (6") dia DI resilient seated non-return valve, flanged end in swing type design with EPDM door and with over 250 micron epoxy coating including all necessary items complete all as specified and as directed.
Supply and fix 100 mm (4") dia DI resilient seated non-return valve, flanged end in swing type design with EPDM door and with over 250 micron epoxy coating including all necessary items complete all as specified and as directed.
Supply and fix 80 mm (3") dia DI resilient seated non-return valve, flanged end in swing type design with EPDM door and with over 250 micron epoxy coating including all necessary items complete all as specified and as directed.
Supply and fix for 150 mm dia D.I. resilient (soft) seated gate valve with pocket less body, ss stem (AISI 410), EPDM coated di wedge 100% vaccum tight design with toroidal sealing rings & over 250 micron epoxy coating in PN16 designed to BS:5163/IS:14846 non-rising stem type with hand wheel operation complete all as specified and as directed.
Supply and fix for 100 mm dia D.I. resilient (soft) seated gate valve with pocket less body, ss stem (AISI 410), EPDM coated di wedge 100% vaccum tight design with toroidal sealing rings & over 250 micron epoxy coating in PN16 designed to BS:5163/IS:14846 non-rising stem type with hand wheel operation complete all as specified and as directed.
Supply and fix for 80 mm dia D.I. resilient (soft) seated gate valve with pocket less body, ss stem (AISI 410), EPDM coated di wedge 100% vaccum tight design with toroidal sealing rings & over 250 micron epoxy coating in PN16 designed to BS:5163/IS:14846 non-rising stem type with hand wheel operation complete all as specified and as directed.
M&L for 150 mm dia ductile iron pipes with flanged ends centrifugally cast Class K-9, with necessary gaskets, nut bolts and other accessories in any length, laid in trenches complete all as specified and directed by Engr-In-Charge.
Construction of brick masonry (full brick thick wall) valve chamber, of 1050x1050x950mm size of internal dimension, PCC work with (1:4:8) type D2 150mm thick (using 40mm grade stone aggregate) for foundation complete with 1.60mm thick MS sheet cover and frame of MS angle iron 40x40x5mm with locking arrangement and painting with one coat of red oxide primer and two coats of synthetic enamel paint all as specified shall be plastering to internal and exposed surfaces of the chamber, in CM(1:4) 15mm thick and PCC coping (1:2:4) type B-1, 50 mm thick all as specified.
Supply, installation, design, testing and commissioning floor mounted indoor panel cubical type of suitable size . The Panel made out of 2mm thick MS CRCA sheet and suitable size angle iron structure ,CPRI approved/Type tested compartmentalized, type of size as required including locking arrangement and powder coated paint after 7 tank cleaning process , fixed in floor with MS angle iron suitable size frame structure and grouted with PCC M-15 (Nominal mix) using 20mm graded stone aggregate with and including suitable size copper FRLS/HRFR copper wired connection, brass glands for cable entry etc complete all as specified and as directed and as following specification : - INCOMER (i) MCCB 400 Amp 4 pole 36 KA with microprocessor based release - 01 No OUTGOING (i) MCCB 250 Amps 4 pole 25 KA with microprocessor based release - 02 Nos (ii) MCCB 63 Amps 4 pole 25 KA with microprocessor based release - 01 No (iii) Digital soft starter suitable for pump mentioned at item No 64 - 02 Nos (iv) DOL/ Fully Automatic Star Delta Starter - 01 Nos (v) 600 Amps capacity copper bus bar of suitable size and required length (equal size for phase and neutral) and fixed on 04 Nos (vi)SMC/DMC/porcelain insulators - 04 Set. (vii) Digital ammeter 0-100 amps -01 No with suitable CTs (viii) Digital voltmeter of 0-500 volts-01 No (ix) LED indicator lamp RYB (set of 3)- 02 set. Note: The panel shall have necessary control circuits interlinked with main fire detection panel for automatic starting and stop facility for the main fire pumps, sprinkler pumps. The jockey pump shall be provided with auto start and stop pneumatic/electronic controls so as to maintain 6kg/sqmm pressure all the time in the fire pumps for working under pre set conditions as desired. Main fire pump and sprinkler pumps shall have auto start and manual stop facility with suitable star delta auto starters having electrical interlocking arrangements and pneumatic/electronic time relays of suitable current ratings and single phasing preventers all as specified and as directed.
INTERNAL FIRE FIGHTING
Supply and fix Addressable manual call point break glass type with alarm LED complete all as specified and as directed.
Supply and fix Control Console complete all as specified and as directed.
Supply , installation, testing & commissioning of cable for fire detection and alarm system with 2 core annealed tinned copper conductor PVC sheathed, flexible, unarmoured 2 core cable 1.5 sqmm as per specifications in existing conduit complete as required complete all as specified and as directed.
Supply and fix for 100 mm dia D.I. resilient (soft) seated gate valve with pocket less body, ss stem (AISI 410), epdm coated di wedge 100% vaccum tight design with toroidal sealing rings & over 250 micron epoxy coating in PN16 designed to BS:5163/IS:14846 non-rising stem type with hand wheel operation complete all as specified and as directed.
Supply and fix 100 mm dia DI resilient seated non-return valve, flanged end in swing type design with EPDM door and with over 250 micron epoxy coating including all necessary items including taking down old unserviceable one complete all as specified and as directed.
Supply only of fire extinguisher ISI marked CO2 type Fire Extinguisher 3.0 KG capacity conforming to IS : 15683 :2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224 , high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, , suitable for operating between 30 degree centigrade to + 55 degree centigrade, Fire Rating Class - 138 all as specified and as directed.
Supply only of stored pressure fire extinguisher ISI marked powder type Fire Extinguisher 4 KG capacity suitable for Class "A", "B", "C" Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating gauge, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammonium phosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centigrade to + 55 degree centigrade, Fire Rating Class - 1A & 13B all as specified and as directed.
Supply only of Fire Extinguisher of lSl Marked Water Stored Pressure type Fire Extinguisher 9 Itrs. capacity consisting of welded cylinder, squeeze lever discharge valve fitted with pressure indicating gauge with internal discharge tube, discharge nozzle suspension bracket, conforming to lS: 15683:2006 (old IS : 6234) duly charged with purged water and pressurized with Nitrogen Gas, suitable for operating between + 50 degree Centigrade to +55 degree Centigrade, Fire Rating Class - 3A all as specified and as directed.
Supply only of Fire Extinguisher Mechanical Foam type ISI Marked Foam (AFFF) type Fire Extinguisher 9 ltrs capacity fitted with Forged Brass squeeze lever discharge valve, conforming to IS : 15683 :2006, complete with initial refill consisting of ISI Marked CO gas cartridge of 60 gms capacity conforming to IS 4947 and ISI Marked AFFF conforming to IS : 4989, suitable for operating between + 50 degree centigrade , Fire Rating Class - 3A & 34B all as specified and as directed.
Supply only of stored pressure fire extinguisher ISI marked powder type Fire Extinguisher 9 KG capacity suitable for Class "A", "B", "C" Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating gauge, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammonium phosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centigrade to + 55 degree centigrade, Fire Rating Class - 1A & 13B all as specified and as directed.
Supply and fix fire bucket with sand as per IS:2546 with nomenclature written on it, provided with suitable size of stand all as specified and as directed.
S&F auto-illuminated (glow-in-dark) sign board with red colour background with appropriate symbol, made up of acrylic sheet for fire escape in minimum 15 cm x 30 cm size to be pasted on wall with high quality adhesive or to be hanged with s.s. hook-chain system all as specified and as directed.
S&F MS ERW pipe heavy grade 15 mm Bore including tee, bend and all connection accessories as per specified and as directed
Supply and fix 150 mm dia DI resilient seated non-return valve, flanged end in swing type design with EPDM door and with over 250 micron epoxy coating including all necessary items including taking down old unserviceable one complete all as specified and as directed.
DG SET
Supplying, installing, commissioning & testing of Silent engine generating set of capacity 160 kVA with acoustic enclosure as per new CPCB-IV/IV+ norms of emission control, 415 volts, 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including acoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with suitable AMF Panel as per manufacturer's recommendations complete all as specified and directed with the following :- (A) Alternator :- Standard design alternator rated at 160 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722.The Alternator shall be:- i) Insulation class - 'H‘ ii) Temperature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1%.
(B) Diesel Engine: - Adequate capacity of Diesel engine as approved by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under :- i) Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping with ERW MS pipe upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. vi) Lub oil System :(a)Lubricating oil filter (b) Lubricating oil pump vi) Air Intake System : (a) Air intake Manifold - Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator.
vii) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant, Paper element filters for fuel, lub oil and by pass, Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel viii) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display. ix) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine x) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling xi) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xii) Base Frame : - Should be provided as OEM norms xiii) Fuel Tank :- HR sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base out side the acoustic enclosure.
(C) CONTROL PANEL :- The standard microprocessor based control panel shall be fabricated made out of CRCA sheet and powder coated in side and out side and shall display as follows:- (i) Voltage of all Three phases, (ii) Current of all Three phases, (iii) Frequency, (iv) Bus bar Chamber with aluminium busbar of cap 300 Amps - 04 Nos, (v) C.T. 100/5 Amps - 03 Nos. (vi) MCCB TPN, of appropriate capacity - 01 No .
D) Acoustic Enclosure:- Manufactured by OEM suitable for 160 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Fuel tank should be out side the enclosure in the sub station building. (v) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- As per OEM Norms vi) The acoustic should be composite in construction and fully assembled integral unit vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform viii) The DG Set should be provided with external Emergency stop push button. ix) The enclosure should be suitably illuminated by LED Lamp fittings. x) The noise level should be 75 dba at 1m under free field conditions. xi) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade. (E) ENGINE INSTRUMENTS PANEL :- All relevant Para meter shall be conventionally displayed on complete panel there by providing easy monitoring of lubricant oil pressure, coolant temperature, battery charging ammeter, RPM and Watt Hour meter, Fuel Level, starting button/switch etc.
Supply, Installing, testing and commissioing of LT Panel factory made indoor type as per IEC 61439 Part 1&2 (Switchgear OEM Type Tested design) with following minimum thickness- Load bearing member/ Doors-2 mm, Non-load bearing/ Internal partitions-1.5 mm, Glandplate/ Base channel-3 mm, Board floor mounted, dust and vermin proof, 3 Phase 4 wire with rated operational voltage 415V, rated insulation voltage of 1000V Impulse withstand of 12Kv and minimum internal Arc with-stand of 65KA, 500 m/sec as per IEC61641, weather proof, with separate hinge door for each compartment with operating handle & locking arrangement with door common openable (screwed/lockable), grouted in PCC 1:2:4 complete. Painting as per OEM defined 7 Tank process with epoxy powder polymerized at high temperature and aluminiumbusbar (TPN) suitable double compression aluminium cable glands with the following accessories. INCOMING : 200 Amp MCCB 415 Volt, 50Hz, AC, 4 pole, 36 KA, with microprocessor based control - 01 No OUTGOING: (i) MCCB 160 Amp, 415V, AC, 50Hz, 4 pole, 25 KA, with thermal magnetic release - 02 No (ii) MCCB 125 Amp, 415V, AC, 50Hz, 4 pole, 25 KA, with thermal magnetic release - 01 No (iii) MCCB 40 Amp, 415V, AC, 50Hz, 4 pole, 25 KA, with with thermal magnetic release control - 03 Nos (iv) 300 Amps capacitor copper bus bar of suitable size and required length (equal for phase & neutral) and fixed on 04 Nos SMC/DMC/Porcelain insulators- 04 set (v) Digital time switch-01 No (vi) Contactor 40 Amp- 01 No (vii) Digital Ammeter 0-200 Amps-01 No with suitable CTs (viii) Digital Voltmeter 0-500 Volts - 01 No (ix) LED indicator lamp RYB (set of 3) - 02 set complete all as specified and as directed.
Design, supply, installation, testing and commissioning, of electrically operated, automatic passenger lift of capacity to carry 08 passengers (544 Kg) at a speed of 1.5 meter/sec, suitable to serve for G+16 floors (17 Floor, 17 Stops) with AC Variable Frequency Regenerative(Closed loop) control drive, equipped with low noise Gearless machine, installed in machine room on roof top complete with all standard accessories and control panel, Full collective Group operation with or without attendant, centre opening doors with door drive automatic operation, stainless steel landing doors. Automatic Rescue Device (ARD), 3D infrared sensor in full height of door, built in announcing system with intercom (in machine room and near ground floor and in car), stainless steel car enclosure complete all as specified and directed with the following :-
(a) Controller Type : Micro Processor controlled Drive VR regenerative (Closed Loop) ACD3-MR (b) Drive : VF Regenerative (Closed Loop) (c) AC Power Supply : 400/415 Volts (3 Phase 4 wire system) (d) Operation : Full Collective Group Operation (e) Car Group : Three car (f) Machine PM (Permanent Magnet) Gearless (Located above shaft in machine room) (g) Traction media : Polyurethane coated steel belts /Steel wire ropes. (h) Car Finish: Stainless steel cool breeze or equivalent design approved by GE for Rear Middle. Rear Corner, side, Front & False ceiling panels.rails. (j) False ceiling type : Stainless steel # 4 (Hairline) along with fitment of car lights LED light fittings. (k) Ventilation : Axial flow fan. (l) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. (m) Flooring : Aluminium Chequered Plate with granite flooring (n) Car Door / Land Doors Finish : Stainless steel # 4 (Hairline). (o) Car Dimensions (internal) (W x D x H - mm) : 1300 x 1100 x 2200 mm. (p) Car and Hoist way Door type : Central Opening Doors.
Design, supply, installation, testing and commissioning, electrically operated, automatic passenger lift of capacity to carry 13 passengers (884 Kg) at a speed of 1.5 metre/sec, suitable to serve for G+16 floors (17 Floors and 17 Stops) with AC Variable Frequency Regenerative(Closed loop) control drive, equipped with low noise Gearless machine, installed in machine room on roof top complete with all standard accessories and control panel with or without attendant, centre opening doors with door drive automatic operation, stainless steel landing doors. Automatic Rescue Device (ARD), 3D infrared sensor in full height of door, built in announcing system with intercom (in machine room and near ground floor and in car), stainless steel car enclosure complete all as specified and directed with the following :-
(a) Controller Type : Micro Processor controlled Drive VR Regenerative (Closed Loop) ACD3-MR (b) Drive : VF Regenerative (Closed Loop) (c )AC Power Supply : 400/415 Volts (3 Phase 4 wire system) (d) Operation : Full Collective (e) Car Group :One car (f) Machine PM (Permanent Magnet) Gearless (Located above shaft in machine room) (g) Traction media : Polyurethane coated steel belts /Steel wire ropes. (h) Car Finish: Stainless steel cool breeze or equivalent design approved by GE for Rear Middle. Rear Corner, side, Front & False ceiling panels. Mirror : Full size mirror to be provided at the rear side of car inside above hand rails. (j) False ceiling type : Stainless steel # 4 (Hairline) along with fitment of car lights LED light fittings. (k) Ventilation : Axial flow fan. (l) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. (m) Flooring : Aluminium Chequered Plate with granite flooring (n) Car Door / Land Doors Finish : Stainless steel # 4 (Hairline).
PILE AND PILE CAP WORK
M&L Boring for bored cast-in-situ, 600mm dia piles in HARD ROCK using DMC method and getting out and disposal of Spoil/rock out side MoD land complete all as specified and as directed.
M&L Boring for bored cast-in-situ, 500mm dia piles in HARD ROCK using DMC method and getting out and disposal of Spoil/rock out side MoD land complete all as specified and as directed.
M&L Chiseling/ chipping/ breaking the laintenance concrete of pile upto cut off level and dressing the pile head so as to receive the form work etc using suitable tools and plants and exposing the pile reinforcement including removal of debris from site complete for 600mm/500mm dia dia piles all as specified and directed.
M&L Carrying out initial load test on 600mm dia pile following tests all as per IS complete all as specified and directed including necessary anchoring and support piles suitable load/ size to be casted as required:
(a) Compression Test
(b) Pull out Test
(c) Lateral Test
M&L Carrying out routine load testing on 600mm dia pile of following tests all as per IS complete all as specified and as directed :
(a) Compression Test
(b) Pull out Test
(c) Lateral Test
M&L Carrying out initial load test on 500mm dia pile following tests all as per IS complete all as specified and directed including necessary anchoring and support piles suitable load/ size to be casted as required:
(a) Compression Test
(b) Pull out Test
(c) Lateral Test
M&L Carrying out routine load testing on 500mm dia pile of following tests all as per IS complete all as specified and as directed :
(a) Compression Test
(b) Pull out Test
(c) Lateral Test
M&L Carrying out Pile Integrity testing on 600mm dia piles including analysing the results as per ASTM D 5882 complete all as specified and as directed
M&L Carrying out Pile Integrity testing on 500mm dia piles including analysing the results as per ASTM D 5882 complete all as specified and as directed
M&L pile capacity by conducting dynamic load test on 600mm dia pile by pile driving analyzer (PDA) all as per IS complete all as specified and as directed
M&L pile capacity by conducting dynamic load test on 500mm dia pile by pile driving analyzer (PDA) all as per IS complete all as specified and as directed
SCHEDULE 'A' PART -XXII (COMPREHENSIVE MAINTENANCE & OPERATION AND MAINTENANCE OF LIFTS)
(a) AMC on 1st year after expiry of defects liability period ( for 3 Lifts)
(b) AMC on 2nd year after expiry of defects liability period ( for 3 Lifts )
(c) AMC on 3rd year after expiry of defects liability period ( for 3 Lifts )
Notes for Serial Item Nos -121 to 123 above :- (i) The rate quoted are deemed to include all/any charges related to renewal of lift license and lift insurance from State Govt/Other Agency.(ii) The rate is inclusive of all items as required at site including any spares to keep the lift operated all the time.(iii) The Maintenance of the lifts should be done through the OEM.(iv) The contractor should attend the complaint/breakdown immediately.(v) Maintenance of the lift should be done as per manufacturer instructions
Operation and maintenance of electrically operated lifts by deploying manpower of 01 operator per shift of 8 Hours, total 02 shifts per day (Total 02 operators) for operating electrically operated 13/8 Passenger lifts(03 Nos) of capacity 544 & 884 Kgs 1.5m/Sec speed to serve (G+16 upper floors) i.e. with upto 17 stops and 17 landings complete for following period
(a) 1st year after completion i.e during defects liability period (1st Year) ( for 3 Lifts)
(b) 2nd year after completion i.e during defects liability period (2nd Year) ( for 3 Lifts)
(c) 1st year after expiry of defects liability period ( for 3 Lifts )
(d) 2nd year after expiry of defects liability period ( for 3 Lifts )
(e) 3rd year after expiry of defects liability period ( for 3 Lifts )
SHREYANSH TRADING AND CONSTRUCTIONS PRIVATE LIMITED (BID ID -3252539)
KAIZEN INDUSTRIES (BID ID -3254368)
KAKALI ENTERPRISE (BID ID -3255020)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid