RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate Bid to RA enabled No ICU Bed ( 8 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standard Parameter Conformity to standard for safety & electromagnetic compatibility IEC-60601-1-2:2001 Standard or IS-13450 IEC-60601-1-2:2001 Standard or IS-13450 Performance Parameter Purpose ICU Bed are required to be used in Intensive Care Unit for comfort of Patient & facilitate comfortable transfer to & from Emergency/OT Ward etc. & also to ICU Bed are required to be used in Intensive Care Unit for comfort of Patient & facilitate comfortable transfer to & from Emergency/OT Ward etc. & also to 1/8 carry out point of care process including Radio- logical procedure at bed side carry out point of care process including Radio- logical procedure at bed side Type of ICU Bed Actuator Electro-Mechanical (Motorized ) Electro-Mechanical (Motorized ) Type of mechanism for functioning or controlling angular motion of bed part Hydraulic mechanism (Motorized) Hydraulic mechanism (Motorized) Type of mechanism for functioning or controlling Height of bed Hydraulic mechanism Hydraulic mechanism Number of section provided in Bed Top 4 * Base frame and support frame should be fabricated using metallic square rectangular section of adequate cross section and thickness to provide high structural strength and stability Yes * Bed top perforated Yes Yes
RequiredNo Bed should have radio translucent top (X-Ray translucent) Yes Yes Availabilty side panel/Side safety guard Yes * Type of side panel Swing Up Down type Swing Up Down type Number of Side panel 4 1
Required2
Required3
Required4 Availability Head & Foot panel/Board Yes * Shape of Head & Foot panel/Board C-type B-type shape
RequiredC-type
RequiredD- type Type of Head & foot Panel Swing Up Down type Detachable type
RequiredSwing Up Down type Material of head and foot panel ABS (acrylonitrile- butadiene styrene) * Availability of good grip for head/foot or side panel Yes * Slots for IV rod at four corners provided Yes * Number of hooks 2 2
Required4 2/8 provided in IV rod Availability of rectangular telesccopic tube box housing for tension spring NA for Super Smooth Crank Screw Mechanism & Hydraulic mechanism for height Yes
RequiredNA for Super Smooth Crank Screw Mechanism & Hydraulic mechanism for height Degree Angle & Height indicator shall be provided at both foot & head side Yes Yes
RequiredNo X-Ray film holder used from One side One side
RequiredBoth side Type of X-Ray Film holder Cassettle Based System * Power of motor in HP(for non motorized put NA) 0.7 hp 0.5 hp
Required0.7 hp
Required0.8 hp
RequiredN/A Better quality bearing should be used Yes * Avaiability of patient constraint belt provided on both side of bed yes yes
RequiredNo Availability of Noiseless
Requirednon rusting swivel castor wheel roller with for easy Mobility & Steering yes * Facility of braking and locking mechanism provided in castor roller Yes * Number of caster to which braking system provided 4 2
Required3
Required4 Availiability Corner buffer in all four corner to protect patient from collision shock Yes * Safe working load capacity of ICU bed in kg 250 150
Required200
Required250
Required120
Required170 Facility of instant non powered/mechanical CPR( Cardiopulmonary Resuscitation) release at the head end for emergency Yes * Lilen Holder/Urine Bag holder provided Yes * 3/8 Accessory Rail Provided at all four side of bed Yes * Mattress provided with ICU bed Yes Yes ICU mattress must X- ray translucent Yes Yes Mattress foam of the Bed should be with Anti Microbial agent incorporated into all components that assists in Prohibiting growth of bacteria & fungi and easy to clean Yes * Mattress shall be made of High resilient & bio- density foam Yes Yes
RequiredNA (If mattress is not provided) Mattress should be translucent to allow radiography using portable X-ray machines Yes Yes
RequiredNA (If mattress is not provided) Mattress should be made in cube cut design & independent cubes promote air flow to reduce moisture Yes Yes
RequiredNA (If mattress is not provided) Material for ICU Bed Mattress Latex Foam Latex Foam
RequiredPU Foam
RequiredNA (if mattress not provided) Maximum thickness of Mattress in mm with tolerance of ± 2 mm 100 * Approx foam Density for Head/sacrum in kg/m3 tolerance NA (if mattress not provided) * Approx foam Density for Heel in kg/m3 NA (if mattress not provided) * Therapeutic Weight limit for mattress in kg 175 150
Required175
RequiredNA (if mattress not provided) Operating temperature & humidity for ICU bed 10 -40 Deg C and relative humidity of 15-90% * Power Supply ( as appropriate fitted with Indian plug) Single phase 230 Volt
Required50 Hz ( AC Supply ) Single phase 230 Volt
Required50 Hz ( AC Supply )
RequiredN/A for mechanical operated 4/8 Facility of Resettable overcurrent breaker shall be fitted for protection Yes Yes
RequiredN/A for handle operated ICU Bed frame and top must be Rust Proof Yes * Type of powder/Paint coating done to ICU Bed frame
Requiredtop & side panel Epoxy Polyester Coating 50-60 microns * ICU Bed should be made up of high quality metal
Requiredpretreated with materials providing good finish
Requiredscratch resistant
Requiredbacteriostatic coating Yes * Process used for pre chemically treatment of metallic bed component Dip tank processes * Facility of easily cleaning/maintenance to ICU Bed Yes * Warranty in years 4 3
Required4
Required5 Product instruction manual shall be supplied Yes * Standard Tool Kit for maintananace and Trouble Shooting to be provided with ICU bed Yes * Demonstration of working to be provided after completing supplies before Acceptance Yes * Dimensional & Material Parameter Material for the frame of bed SS MS
RequiredSS Material for side railling/Side Safety guard SS MS
RequiredSS
RequiredAl-alloy
RequiredABS Plastic Material for Head & Foot Panel/Board SS MS
RequiredSS
RequiredAl-alloy
RequiredABS Plastic Material for Bed top Section ABS Plastic MS
RequiredSS
RequiredABS Plastic Material of wheels SS Polyester
RequiredMS
RequiredSS Material for IV rod SS SS
RequiredMS
RequiredAl-alloy 5/8 with chromium plated Maximum Adjustable Back Rest Angle in Degree 0-70 0-70 Maximum Adjustable Knee Rest Angle in Degree 0-40 0-40 Diameter of Castor Roller in mm 130-150 * Maximum Trendlenburg Angle in Degree with tolerance ±2 degree 10 10
Required15
Required20 Maximum Reverse Trendlenburg Angle in Degree with tolerance ± 2 degree 15 10
Required15
Required20 Bed height adjustibility range in mm 500-900 * Mean coil diameter of tension spring used in counter weight mechanism in mm N/A for Super Smooth Crank Screw Mechanism & Hyraulic mechanism for height 40
RequiredN/A for Super Smooth Crank Screw Mechanism & Hyraulic mechanism for height Spring coil diameter used in counter weight mechanism in mm N/A for Super Smooth Crank Screw Mechanism & Hyraulic mechanism for height 6
RequiredN/A for Super Smooth Crank Screw Mechanism & Hyraulic mechanism for height Clearance between Bed Base frame and Floor surface in mm 120 120
Required150 Length of bed in mm with 2% tolerance 2000-2100 2000-2100
Required2100-2200 Width of bed in mm with 2% tolerance 1000-1050 950-1000
Required1000-1050
Required1050-1100 Weight of ICU Bed in Kg 150 * Additional Parameters Spares ICU Bed Mainframe supplied 2 1
Required2
RequiredNot supplied Spares Pair of Bed Ends
Requireddetachable supplied 2 1
Required2
RequiredNot supplied Spares Collapsible side rails supplied 2 1
Required2
RequiredNot supplied Spares IV Rods supplied Not Supplied 1
Required2
RequiredNot Supplied Spares Matress simmilar to one not supplied 1
Required2
Requirednot supplied 6/8 supplied with ICU bed Reports Certifications for Product European CE European CE
RequiredBIS Electric Shock Protection level- Class-B/class-1 Yes Yes Availability of ISO certification with manufacturer Yes * ISO certification Number and Date if ISO certificate not availiable then put NA - * Copies of test Reports/certificates and other certifications to be furnished to buyer on demand at time of supplies Yes * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.