Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹15.5 L+₹2.5 L (19.2%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹15.8 L+₹2.8 L (21.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
5 Mar 2024, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
SPL REPAIR TO BLDG NO P-62B AT POONCH, SPECIAL REPAIR/REPLACEMENT AGAINST BER ITEMS/EQPT IN THE AOR OF STN HQ BG AND SPECIAL REPAIR/REPLACEMENT OF LT PANEL AND CONNECTED ITEMS AT MENDHAR UNDER GE 881 EWS
2024_MES_640755_1
GE/PNH-70/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹47,000
Yes
18 Apr 2024
6 Feb 2024
7 Mar 2024
6 Feb 2024
5 Mar 2024
20 Feb 2024
Amount
B&R PORTION: Dismantling timber scantling 40 sqcm and over in section unframed work, complete all as specified and directed.
Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (unreinforced) on ground floor or paving not exc 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 20-25mm thick , bedded and jointed with grey cement slurry and pointed with grey cement with admixture or pigment to match the shade of Kota stone slab as approved by GE, laid over and including screed bed or bedding layer of mortar 20mm thick in Cement Mortar (1:6) including cutting, grinding and mirror polishing, complete all as specified and directed.
M&L for machine cut pre polished Kota stone 20-25mm thick as in riser of steps, skirting, dado and pillar fixed over & including cement plaster 10mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the kota stone including cutting, grinding and mirror polishing, complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M&L for walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
M&L for walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), (except stone) complete all as specified and directed.
Taking down cement plaster on wall of any desription incl racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed.
M&L for 15 mm thick rendering in CM 1:6 on stone masonry surfaces or other than fair faces of brick work or on one side of lathing, finished even & smooth without using extra cement, complete all as specified and as directed.
M&L for 15 mm thick rendering in CM 1:4 on stone masonry surfaces or other than fair faces of brick work or on one side of lathing, finished even & smooth without using extra cement, complete all as specified and directed.
M&L for applying two coats of distemper on walls over newly plastered surfaces of wall incl preparation of surfaces complete all as specified and as directed.
M&L for applying two coats of cement base paint on walls over newly plastered surfaces of wall incl preparation of surfaces complete all as specified and as directed.
Material & Labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistent exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces in camouflage pattern on walls complete all as specified and directed.
Dismantling of wall and ceiling boards any thickness including cover cover fillets, complete all as specified and directed.
S&F 25 mm thick, 2nd class hard wood boarding planed one side, with butt joints and fixed with nails supplied and fixed in repairs on existing floors/ceiling and skirting, facia etc in patches, incl cutting out, piecing, heading joints etc ,complete all as specified and as directed.
S&F Plywood, grade BWR, type BB, fixed in ceiling with nails to timber frame work ,complete all as specified and as directed.
M&L for second class soft wood plain fillets, square, rectangular or triangular in section clean sawn, exc 3 sqcm & not exc 6 sqcm and secured with nails or brads, complete all as specified and as directed.
M&L for two coat of synthetic enamel paint over a coat of pink primer including preparation of new or previously untreated wooden surfaces of any description, over 10cm width or girth, complete, all as specified and directed.
M&L for one coat of synthetic enamel paint on old wooden surfaces including preparation of surfaces of any description, over 10cm width or girth, complete all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.5 Sqm each, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 Sqm and not exceeding 4Sqm each, complete all as specified and directed.
S&F clean sawn 2nd class hard wood straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joint etc ,complete all as specified and as directed.
All as per srl item No. 23 above but except timber, complete all as specified and as directed.
M&L for cement concrete (1:2:4) using 20mm graded stone aggregate as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, bed block, kneelers, apex stones, bed plates, roof kerbs round or chamfered on edges, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for second class soft clean sawn timber frame and fixed as in scantlings incl ceiling work, complete all as specified and as directed.
M&L for 50mm thick PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
M&L for Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
Cutting holes in stone walls exc half bricks but not exc one brick in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, complete all as specified and directed.
S&F Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F 35 mm thick 2nd Class hard wood glazed and skeleton shutters, open rebated and prepared to receive gauge etc (with sash bars), edges of framing plain, chamfered or grounded, fitted with cut of and mitred beads for securing gauge etc of size of members of shutters as specified in SSR Part-I section 8 clause No. 8.2(a) and fitted to chowkats complete all as specified and as directed.
S&F 35mm thick 2nd class hard wood plain, framed, panelled door shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and directed.
S&F 30 mm thick 2nd Class hard wood glazed and skeleton shutters, open rebated and prepared to receive gauge etc (with sash bars), edges of framing plain, chamfered or grounded, fitted with cut of and mitred beads for securing gauge etc of size of members of shutters as specified in SSR Part-I section 8 clause No. 8.2(a) and fitted to chowkats complete all as specified and as directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed.
S&F galvanised mild steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
S&F mild steel butt hinges, medium weight, cold rolled, 75mm long, complete all as specified and directed.
S&F mild steel butt hinges, medium weight, cold rolled, 100mm long, complete all as specified and directed.
S&F 250mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding of extruded section ,complete all as specified and as directed.
S&F aluminium anodised, barrel tower bolts of extruded section of size 150mm and fixed, complete all as specified and directed.
S&F aluminium anodised, barrel tower bolts of extruded section of size 75mm and fixed, complete all as specified and directed.
S&F aluminium alloy handles, cast type, anodised of size 150mm and fixed, complete all as specified and directed.
S&F aluminium alloy handles, cast type, anodised of size 100mm and fixed, complete all as specified and directed.
S&F Floor door stopper of overall length of cover plate and made up of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed.
M&L for preparation of old decorated steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Taking down carefully unsv sub main wiring including earth continuity any type/ size with surface casing/ caping/ TW batten/ PVC conduit surface or recess etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and directed.
M&L for point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :-
One light/fan point controlled by one way switch 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed.
All as per srl item No 49 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC/poly carbonate, insulated body, complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 5 pin, 6 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 5 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 5 and 15 Amp flush type universal, complete all as specified and directed.
S&F in replacement lamp holder, insulated body, complete all as specified and directed.
S&F in repair LED inverter lamp CDL 12 watt with holder base (B22) type, complete all as specified and directed. Make of LED lamp:- Havells cat part No LHLDDDBAIA2R012 or Equivalent cat part of make as specified in Appx 'A' to P.S.
Supply and fixing in repair inverter LED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hours with driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Havells cat part No. LHEXACP7FN1W020 or equivalent make as specified in PS
Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver including suitable bracket fixed to wall/ pole complete with IP 65/66 protection complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F in repair MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
S&F Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
S&F Sub main wiring with single core cable 2x 4 Sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 4 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly, complete all as specified and directed. Note:-Three wire of 4 Sqmm and one run of pvc conduit/casing caping shall be measured as one unit.
Supply, laying , jointing and testing in repair of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 16 sqmm 2 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable sizes and aluminium lugs for connection, complete all as specified and directed.
S&F in repair geyser/water heater of capacity 25 ltrs 5 star rated ISI marked by means of drilling hole in wall, grouting rack bolt 100mm long for holding geyser upto 50 ltrs on wall including all accessories such as safety valve, thermostate, NRV, etc including making good and matching existing surface and finish complete all as specified and directed.
S&F in repair PVC connection 15mm size with PTMT nuts on both ends of length 750mm complete all as specified and directed.
S&F new BLDC ceiling fan of 1200 mm sweep, min air delivery 210 CFM, 230 V, 50 Hz with service valur 6.00 BEE, 5 star ratingincl all connecting accessories and incl taking down old existing fan and deposited to store complete all as specified and directed.
S&F exhaust fan made up of steel body, AC single phase, 230 V of size 300 mm sweep with blades and frame and louvers incl all connecting accessories and incl taking down old existing fan and deposited to store complete all as specified and directed by Engineer-in-charge.
S&F exhaust fan made up of steel body, AC single phase, 230 V of size 380 mm sweep with blades and frame and louvers incl all connecting accessories and incl taking down old existing fan and deposited to store complete all as specified and directed by Engineer-in-charge.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, incl taking down old existing regulator and deposited to store complete all as specified and directed.
S&F 16 amps plug top suitable for water heater storage type, complete all as specified and directed.
S&F sheet metal enclosure for DBs, SPN double door (IP43), 4 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning incl taking down old DB and deposited to store complete all as specified and directed.
S&F MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
Supply, laying , jointing and testing in repair of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 120 sqmm 3.5 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable sizes and aluminium lugs for connection, complete all as specified and directed. Note: Excavation, earthwork, sand cushioning, brick protection shall be measured & paid for separately.
M&L for Sand cushioning to under ground cable providing with a layer of Sand 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : Punned down thickness of 18 cm will be measured for payment purpose)
M&L for Burnt bricks locally available, sub class 'B', laid flat for protection of under ground cable complete all as specified and directed at site.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in any type of soil complete all as specified and directed.
Returning, filling in surplus spoil including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
S&F in repair Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed. NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
narayan construction
VIKAS ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .