| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹16.5 LAccepted-AOC R O KHOJA BAGH BARAMULLA JAMMU KASHMIR | BARAMULLA | BARAMULLA | JAMMU AND KASHMIR | 193103 | ₹16.5 L Quoted ₹16.7 L | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹16.8 L+₹12,260 (0.73%)Rejected-Finance | ₹16.8 L+₹12,260 (0.73%) | L-2 | Rejected-Finance other than L-1 |
| 3 | L-3₹18.0 L+₹1.3 L (7.77%)Rejected-Finance 29 IQBAL COLONY SONWAR SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | ₹18.0 L+₹1.3 L (7.77%) | L-3 | Rejected-Finance other than L-1 |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
19 Dec 2022, 6:00 pmClosed
Tapan Naurial, Lt Col, GE
GE 864 EWS, PIN-913864,C/o 56 APO
Repair/replacement of different type of MCCB in existing LT Panels including UG cable and allied works at BB Cantt Srinagar
2022_MES_560432_2
864/WS-49/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
B B Cantt.
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹36,000
Yes
11 Jan 2023
30 Nov 2022
21 Dec 2022
30 Nov 2022
19 Dec 2022
7 Dec 2022
Amount
Excavation in trenches in any type of soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed.
Returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed
Removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. Note:- Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
M&L for Cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc complete all as specified and directed.
M&L PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) in coping / plinth blocks for poles and the like including weathering , slightly rounded or chamfered angles and throating, as directed including necessary Steel form work and finishing the surfaces fair in forms complete all as specified and directed.
Dismantling of unserviceable ACB and S&F ACB 4 Pole,415 volt, with microprocessor release, adjstable release mannual draw type of capacity 630 Amps,65 KA including testing & commisioning .
Description all as per srl item No 8.00 above but 800 Amps, 4 pole and 36 KA
Description all as per srl item No 8.00 above but 1000 Amps, 4 pole and 36 KA
M & L for replacement of damaged copper bus bars having any length 25 mm dia complete all as specified and as directed
S & F in replacement of heat shrink insulation tubes for all the bus bars and maintaining the RYB sequence in the system complete all as specified and as directed
M & L for earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl copper strip 20x3 mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion incl earth work and excavation in any type of soil, PCC (1:2:4) type B1 chamber, precast RCC slab 40mm thick in (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe 20mm GI, wire mesh and lugs, incl test point complete all as specified and as directed
Cutting and trimming of tree branches to clear the over head lines in the arc of HT/LT over head lines feeders complete in 2/4 pole structure/sub station area (including repairing and jointing of ACSR conductor if damaged during cutting of trees) and removal of the trimmed branches of trees, removing and depositing the same away from the site, complete all as specified and directed by Engineer-in-Charge. Notes :- All tools required for the job shall be arranged by the contractor within the overall cost quoted in the item.
S&F in replacement MCCB 4 Pole, 415 V,16 KA breaking capacity, thermal magnetic type of capacity 40/63/100 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole, 415 V, 16 KA breaking capacity, thermal magnetic type of capacity 125 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 415 V, 4 Pole, 36 KA breaking capacity, adjustable type of capacity 160 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole,415 V, 36 KA breaking capacity, adjustable type of capacity 200 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole,415 V, 36 KA breaking capacity, adjustable type of capacity 250 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole, 36 KA breaking capacity, thermal magnetic type of capacity 315/320 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole,415 V, 36 KA breaking capacity, adjustable type of capacity 400 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole, 415 V, 36 KA breaking capacity, adjustable type magnetic type of capacity 500 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
M&L for electrical insulation tape roll of 20 Mtr length in repair/maintenance of cables or fixing of thimbles or colour coding of cables in panels/joints etc complete all as specified and directed.
Supply and fixing in replacement LED flood light 50/70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fixing in replacement LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant warm/white complete with driver and lamp all as specified and directed.
S&F in replacement LED lamp 10/12/15 watt capacity B-22 base LED emergency bulb for post top fittings warm/white light complete all as specified and as directed by Engr-in-Charge
S&F in replacement full glow glass LED bulb, energy saver filament LED lamp 7/9/10 watt capacity B-22 base for garden warm/yellow/crystal white light complete all as specified and as directed by Engr-in-Charge
S&F in replacement spot light underwater 3/5/7 Watt submersible gardern fountain with RGB lightingh EU plug complete all as specified and as directed by Engr-in-Charge
Supply & lay cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 Volts graded of cross section area :-
120 sqmm, 3.5 core.
95 sqmm, 3.5 core.
70 sqmm, 3.5 core.
50 sqmm, 3.5 core.
35 sqmm, 3.5 core.
25 sqmm, 3.5 core.
16 sqmm, 2 core.
10 sqmm, 2 core.
10 sqmm, 2 core.
Supply only for Aluminium thimble/ferrule suitable for LT UG Cable,1100V for the following size of cable:-
S&F cable jointing kit for Lt 1.1 KV cable for outdoor/indoor termination heat shinkable type end joint complete with jointing meterial and accessories suitable for XLPE armoured aluminium conductor cable of following sizes:-
400 to 630 sqmm 3.5 core
240 to 300 sqmm 3.5 core
150 to 185 sqmm 3.5 core
70 to 120 sqmm 3.5 core
25 to 50 sqmm 3.5 core
M&L for surface dressing not exc 15cm deep and averaging 10cm deep and cleaning of surroundings of electrical installations/sub stations/2 & 4 pole structure/Panels/transformers drainage installation by cutting vegetation, bushes, grass etc. and surface dressing, complete all as specified and directed by Engineer-in-charge
S&F in replacement Volt meter digital, 96 x 96mm size, 0-500 volts, AC, complete all as specified and directed. Make - L&T/ Rishabh/ Siemens/ HPL.
S&F in replacement ampere meter digital, 96 x 96mm size, 0-100A size, AC, complete all as specified and directed. Make - L&T/ Rishabh/ Siemens/ HPL.
S&F in repairs/replacement phase indicating lamps LED type RYB, complete all as specified and directed. Make- L&T/ Rishabh/ AE.
S&F in repairs/replacement die cast resin CT for digital Amp meter, ratio of CT, complete all as specified and directed Engineer-in-Charge. Make:- L&T/ Rishabh/ Siemens.
M&L for wiring of voltmeter or ammeter with copper conductor single core 1.5 sqmm size, complete all as specified and directed.
M&L in replacement of GI clamp with GI nuts, bolts & washers for 25 mm dia copper/GI/MS bar (as per sample) complete all as specified and directed
M/S Vijay Constructions
M/S TAHIRA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .