Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.6 LAccepted-AOC WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | 1 | Accepted-AOC Lowest Accepted Bidder | |
| 2 | 2₹29.9 L+₹1.7 L (6.10%)Rejected-AOC | 2 | Rejected-AOC Lowest Accepted Bidder is M/S B.K. Roy and Sons | |
| 3 | 3₹33.6 L+₹5.4 L (19.1%)Rejected-AOC 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | 3 | Rejected-AOC Lowest Accepted Bidder is M/S B.K. Roy and Sons | |
| 4 | 4₹34.0 L+₹5.8 L (20.4%)Rejected-AOC 1ST SHAKUNTALA SADAN 04 RAMPURA BASTI LALGARH BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | 4 | Rejected-AOC Lowest Accepted Bidder is M/S B.K. Roy and Sons | |
| 5 | 5₹35.4 L+₹7.2 L (25.4%)Rejected-AOC BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | 5 | Rejected-AOC Lowest Accepted Bidder is M/S B.K. Roy and Sons |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Jan 2023, 6:00 pmClosed
Col Avik Saxena, CWE Bikaner
HQ CWE Bikaner, Mil Stn Bikaner, PIN-334001
Repair and replacement of elect wiring and panel at MD Accn under AGE B/R-I under GE (N) Bikaner at Mil Stn Bikaner
2022_MES_566600_2
CA NoCWE BKN-Token No. 52/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Bikaner
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE (N) Bikaner
₹90,000
Yes
20 Feb 2023
4 Jan 2023
23 Jan 2023
4 Jan 2023
16 Jan 2023
11 Jan 2023
4 Jan 2023 - 7 Jan 2023
Amount
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/ batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 and wall putti with distempering/ painting (matching same colour) of wall shall deemed to be included in quoted rate of this item.
All as per serial item No. 2.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one light point controlled by two, two way switches complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch piano, flush type, single pole, one way, 15/16 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch piano, flush type, single pole, two way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F bell push, flush type, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 3 pin, 5/6 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 2 in 1, 3 pin, 5 and 15 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, fixed as in repairs complete all as specified and as directed.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, fixed as in repairs complete all as specified and as directed.
S&F electronic fan regulator, flush type, stepped type with 5 step control, 230 Volts, 150 Watt, including making hole in sheet top cover and connecting up, ISI marked, fixed as in repairs complete all as specified and as directed.
Supply and fixing Bell ‘Ding Dong’ / ‘Multi Music’ Type, AC, 230 Volts, ISI marked, fixed as in repairs complete all as specified and as directed.
Taking down of serviceable LED light fitting and refixing LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt 240 Volt, 50 Hz AC, ISI Marked decorative type with driver holder and LED lamp, correlated colour temperature shall be minimum 6500 degree Kelvin, including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Taking down of serviceable LED light fitting and refixing LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 230 Volt, 10 kA, ‘C’ Curve, fixed in repairs, complete all as specified and as directed.
Supply & Fixing MCCB TPN DB 4 way vertical type 440 Volts, 3 Phase, IP-43 protection, IK-09 with rated bus bar 200 Amps, double door type suitable for MCCB as a incomer and MCBs as outgoing, double door type, grouted in walls with accessories, including taking down old existing unserviceable DB with fixtures of any type complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 and wall putti with destempering/ painting (matching same colour) of wall shall deemed to be included in quoted rate of this item.
Supply and fixing double door, sheet metal enclosure powder coated for fixing MCB, DB SPN, 12 Way, fitted with neutral link, earth bar, din rail and 200 Amps rated bus bar, 230 Volts conforming to IS-13032-1991 and including taking down old existing unserviceable DB with fixtures of any type & capacity complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 and wall putti with distempering/ painting (matching same colour) of wall shall deemed to be included in quoted rate of this item.
Supply and fixing double door, sheet metal enclosure powder coated for fixing MCB, DB SPN, 08 Way, fitted with neutral link, earth bar, din rail and 200 Amps rated bus bar, 230 Volts conforming to IS-13032-1991 and including taking down old existing unserviceable DB with fixtures of any type & capacity complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 and wall putti with distempering/ painting (matching same colour) of wall shall deemed to be included in quoted rate of this item.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, rupturing capacity 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, SPN, 240 Volts, rupturing capacity 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
Supply and fixing in VTPN / LT Panel MCCB 4 Pole 63 Amps, fixed type, breaking capacity 16 KA, 415 Volt and including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
Supply and fixing in VTPN / LT Panel MCCB 4 Pole 100 Amps, fixed type, breaking capacity 16 KA, 415 Volt and including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades & refixing ceiling fan of any make, any sweep, keeping side to store in safe custody for painting of ceiling fans complete, insitu with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed.
M&L for taking down carefully existing serviceable exhaust fan of any sweep, dismantling blades and removing fan and blades and re-fixing exhaust fan, keeping side in store in safe custody for painting of exhaust fan complete in-situ with synthetic enamel paint by spraying including filling cavities with filler one coat after proper cleaning and connecting up with and including writing MES No. and including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto ceiling rose, complete all as specified and as directed.
M&L for carefully disconnecting electric & water connections and taking down existing serviceable Geyser (water storage type) of capacity 25/50 litre vertical type and re-fixing the same with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of suitable size but not less than 10mm dia 125mm long with nuts & washers) into the wall grouted properly to hold the geyser and making good the disturbed surface as original and re-connecting electric & water connections, complete all as directed.
Taking dwon old unserviceable existing iron box size 300x300mm and 450x900mm including MCB/MCCB of any capacity and any size and removing from site and filling brick work with plaster making good the disturbed surface of wall complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through existing PVC conduit ISI marked including fittings/accessories, fixed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for making good surface of wall in CM 1:4 and wall putti with distempering/ painting (matching same colour) of wall shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for making good surface of wall in CM 1:4 and wall putti with distempering/ painting (matching same colour) of wall shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through existing PVC conduit ISI marked including fittings/accessories, fixed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for making good surface of wall in CM 1:4 and wall putti with distempering/ painting (matching same colour) of wall shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for making good surface of wall in CM 1:4 and wall putti with distempering/ painting (matching same colour) of wall shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 10 sqmm (nominal area) size main cable & one run of 10 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through existing PVC conduit ISI marked including fittings/accessories, fixed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 10 sqmm size main cable, 01 run of 10 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for making good surface of wall in CM 1:4 and wall putti with distempering/ painting (matching same colour) of wall shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with Four runs of 10 sqmm (nominal area) size main cable & two run of 10 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 32mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 04 runs of 10 sqmm size main cable, 02 run of 10 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for making good surface of wall in CM 1:4 and wall putti with distempering/ painting (matching same colour) of wall shall deemed to be included in quoted rate of this item.
ALPHA ENGINEERING COMPANY
A.S. CONSTRUCTION COMPANY
J.D INFRA ENGINEERING
BIDAWAT ENTERPRISES
G R POWERS
durga construction company
ENGINEER CORPORATION OF INDIA
JASNATH ENTERPRISES
M/S BIKANER CHEMICAL LABORATORIES
M/s Chopra Associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .