Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.2 CrAccepted-AOC 614 HARIOM TOWER COMMERCIAL COMPLEX CIRCULAR ROAD LALPUR RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | ₹66.2 Cr | L1 | Accepted-AOC L1 Letter No. 2764(S)WE Date-31.05.2023 |
| 2 | L2₹67.5 CrRejected-Finance 23 SAHID SURYA SEN ROAD BERHAMPORE MURSHIDABAD W B | MURSHIDABAD | WEST BENGAL | 700023 | ₹67.5 Cr | L2 | Rejected-Finance L2 Letter No. 2664(S)WE Date-31.05.2023 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
| 4 | Rejected-Technical 3D VATIKA APARTMENT LINK TANK ROAD RANCHI | RANCHI | JHARKHAND | 829205 | - | - | Rejected-Technical Non Responsive |
| 5 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
Tender Value
₹60.2 Cr
EMD Value
₹60.3 L
Closing Date
16 Dec 2022, 12:00 pmClosed
Executive Engineer, RCD, Road Division, Godda
Executive Engineer, RCD, Road Division, Godda
Reconstruction of Simra-Boarijore-Borio Road (MDR-208) from Km 4.00 to Km 17.150 including Bridge (Total Length- 13.150 Km) under Road Division, Godda for the year 2022-23
2022_CECOM_63334_1
RCD/GODDA/1257/2022-23
Open Tender
Civil Works - Roads
365 days
Opening point- At basdiha
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
Executive Engineer, RCD, Road Division, Godda
₹60.3 L
Chief Eng. (Comm), RCD, Jharkhand, Ranchi
7 Jun 2023
24 Nov 2022
19 Dec 2022
24 Nov 2022
16 Dec 2022
2 Dec 2022
1 Dec 2022
Amount
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. JH RCD SOR 2.03 (ii) A
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres) Lime /Cement Concrete,By Mechanical Means Prestressed / Reinforced cement concrete grade M-20 & above Vide JH RCD SOR 2.04 II B
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres) Lime /Cement Concrete,By Mechanical Means,Cement Concrete Grade M-15 & M-20 Vide JH RCD SOR 2.04(i) I B
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres) Dismantling Brick / Tile work,Rubble stone masonry in cement mortar. Vide JH RCD SOR 2.04(iii) B
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres), Removing all type of hume pipes and stacking within a lead of 1000 metres including earthwork and dismantling of masonry works., Up to 900 mm dia Vide JH RCD SOR 2.04(ix) C
Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately), By Mechanical Means,Bituminous course JH RCD SOR 2.05(II) A
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 metres. (Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m), JH RCD SOR 3.06
Construction of Embankment with Material Deposited from Roadway Cutting (Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2),Rolling with vibratory roller. Rate per cum after adding royalty@Rs 27.48/cum JH RCD SOR 3.17
Construction of Subgrade and Earthen Shoulders (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2) JH RCD SOR 3.18 I
Construction of Subgrade With Stone Dust (Construction of subgrade and earthen shoulders with approved material (Stone Dust) obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2) Stone Dust NS ITEM
Granular Sub-Base with Graded Material (Table:- 400- 1), Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loder at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.,Rate per cum for grading-v Material JH RCD SOR 4.01 B (v)
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.) JH RCD SOR 4.14 B
Prime coat (Providing and applying primer coat with SS1 Grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means.) JH RCD SOR 5.01 A i
Tack Coat on Bituminous surfaces (Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom.) JH RCD SOR 5.02 (i)
Tack Coat on Granular surfaces treated with primert (Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom.) JH RCD SOR 5.02 (ii)
Dense graded Bituminous Macadam Grading-II With VG-30 Bulk Bitumen, Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @4.5 percent by weight of total mix and filler, transporting the hot mix to work site laying with a hydrostatic paver finisher with sensor control to the required grade level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 505 complete in all respects with VG-30 Bulk Bitumen. JH RCD SOR 5.04 A B
Bituminous concrete Grading- II With VG-30 Bulk Bitumen,Providing and laying bituminous concrete with higher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment , rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 507 complete in all respects with VG-30 Bulk Bitumen. JH RCD SOR 5.05 A B
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67).,(ii) 90 cm equilateral triangle JH RCD SOR 8.04 A II
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.), (xiii) 60cmx60cm Square JH RCD SOR 8.04 A XIII
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.), (VIII)60 cm circular JH RCD SOR 8.04 A (VIII)
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.),(X)80 cm x 60 cm rectangular JH RCD SOR 8.04 A (X)
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.),(XII)60 cm x 45 cm rectangular JH RCD SOR 8.04 A (XII)
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.),(XV)90cm high Octagonal JH RCD SOR 8.04 B (XV)
Direction and Place Identification Signs upto 0.9 sqm Size Board.(Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4 mm with area not exceeding 0.9 sqm fixed over back support frame of min 35 x 35 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing) JH RCD SOR 8.05
Solar Powered Road Marker (Solar Stud) Supplying of Solar Raised Pavement Markers made of polycarbonate molded body with circular shape, solar powered, LED self illumination in active mode 360 degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode.The marker shall support a load of 20000 kg tested in accordance to ASTM D 4280.The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand temperatures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow (amber) as per requirement and typical frequency of blinkikng in 1 Hz.There should be current losses of less than 20 microamperes at 2.4 V in sleepcharging mode to enhace the life of the marker and a full charge should provide for a minimum autonomy of 50 hours.The height, width and length of the marker shall not be less than 10mmx100mmx100 mm. Also, the surface diameter of the marker shall not be less than 100 mm respectively.The weight of the marker shall not exceed 0.5 Kilograms.Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the engineer.) JH RCD SOR 8.35
Metal Beam Crash Barrier (Type - A, "W" : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) JH RCD SOR 8.23 A
Road Delineators (Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide stripes, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and confirming toIRC-79 and the drawings.) JH RCD SOR 8.15
Kilo Metre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc),5th kilometre stone (precast) JH RCD SOR 8.14 I
Kilo Metre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc),Ordinary Kilometer stone (Precast) JH RCD SOR 8.14 II
Kilo Metre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc),Hectometer stone (Precast) JH RCD SOR 8.14 II
Printing new letter and figures of any shade (Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade) English and Roman JH RCD SOR 8.03
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.) JH RCD SOR 8.13
Overhead Signs (Providing and erecting overhead signs with a corrosion resistant aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans)Truss and Vertical Support JH RCD SOR 8.07A
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications RCC Grade M20 using batching plant, transit mixture & Concrete pump JH RCD SOR 12.08 C Case-i
Fixing of reflective sheeting including all cost of material and fitting charge complete work as per specification and direction of E/I NS Item
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.), Mechanical Means, Depth upto 3 m JH RCD SOR 12.01 B (i)
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications, PCC Grade M15 using batching plant & Concrete pump JH RCD SOR 12.08 A Case-i
Stone masonry work in cement mortar 1:3 in foundation complete as drawing and Technical Specification, Random Rubble Masonry JH RCD SOR 12.07 (B)
Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and Technical Specifications, Random Rubble Masonry JH RCD SOR 13.04 A
Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification., Boulder laid dry without wire crates. JH RCD SOR 16.01
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification,RCC Grade M25 Using Batching Plant, Transit Mixer and Concrete Pump, For solid slab super-structure, 20-30% of (a+b+c) , Height upto 5m JH RCD SOR 14.01 B (i) (p)
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications JH RCD SOR 14.04
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications, PCC Grade M20, using batching plant, transit mixer & concrete pump Height upto 5m JH RCD SOR 13.05 B (p)
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications JH RCD SOR 14.02
Brick masonry work in 1:3 in sub-structure complete excluding pointing and plastering, as per drawing and technical specifications JH RCD SOR 13.01
Plastering with cement mortar (1:3 ) on brick work in sub-structure as per Technical specifications JH RCD SOR 13.03
Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces) JH RCD SOR 8.08
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification. JH RCD SOR 13.10
Providing Tarfelt Cushion under the Decl slab complete as per drawing and Technical specification. NS item
Filler joint (Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications.) JH RCD SOR 14.18 (iii)
Filler joint (Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight) JH RCD SOR 14.18 (iv)
Numbering and writing the culvert no. etc, -do-do- all complete. NS item
Laying Reinforced Cement Concrete Pipe NP4/prestrssed concrete pipe on first class bedding in single row . (Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ), 1000 mm dia JH RCD SOR 9.04 A
PCC 1:3:6 M10 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.) JH RCD SOR 12.04
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications. RCC Grade M20 using batching plant, transit mixer & concrete pump JH RCD SOR 13.05 E (p)
SFF M.S. Grating made with 25mmx 8mm MS flats @ 25mm c/c Bith way fitted on 25x25x6mm angle frame duly fixed in cover of drain with 4nos 75 long fish tailed ciamp all com. Job. NS ITEM
Providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing JH RCD SOR 12.22
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1200 mm) JH RCD SOR 12.25
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification, RCC Grade M30, using batching plant & concrete pump. JH RCD SOR 12.40 C (case-i)
Levelling course for Pile cap M15 Providing and laying of PCC M15 levelling course 100 mm thick below the pile cap.using batching plant & concrete pump. JH RCD SOR 12.41 case-i
Pile load test on single vertical pile in accordance with IS:2911(Part-IV) JH RCD SOR 12.38
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications. JH RCD SOR 12.42
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. , Granular material JH RCD SOR 13.09 A
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification JH RCD SOR 14.10 Case-i
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications. RCC Grade M30 using batching plant, transit mixer & concrete pump JH RCD SOR 13.05 G (p)
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications. RCC Grade M35 using batching plant, transit mixer & concrete pump JH RCD SOR 13.05 F (p)
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications JH RCD SOR 13.08
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications JH RCD SOR 13.06
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification.,RCC Grade M30 Using Batching Plant,Transite Mixer and Concrete Pump. For T-beam, RCC Girder, Cross Girder & slab, 20-30% of (a+b+c) JH RCD SOR 14.01 (C) (i) (p)
Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications. JH RCD SOR 14.06
Reinforced cement concrete M30 approach slab including reinforcement and formwork complete as per drawing and Technical specification JH RCD SOR 14.11
Modular Strip / Box Seal Joint, Providing and laying of a modular strip Box seal expansion joint including anchorage catering to a horizontal movement beyond 70 mm and upto 140mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation. JH RCD SOR 14.22
Drainage Spouts complete as per drawing and Technical specification JH RCD SOR 15.17
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications. JH RCD SOR 13.16
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification JH RCD SOR 16.05
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications JH RCD SOR 16.04 A
Reinforced Cement Concrete Crash Barriers for Bridge (Provision of an Reinforced cement concrete crash barrier at the bridge decks& approaches to bridge structures constructed with Rein forced Cement Concrete With HYSD reinforcement confirming MoRT&H Specification and as per details given IRC-5 including dowel bars ,expansion joints filled with pre-moulded asphalt filler board etc.. and approved drawing and at locations directed by the Engineer ,all as specified .) Crash Barriers for Bridge (Height 1100 mm) as per detais given IRC-5 (fig.-2 ) (Area -0.298 sqm. For 1 meter length ) JH RCD SOR 14.15 B
Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) JH RCD SOR 14.16
Construction of Median and Island with Soil Taken from Roadway Cutting Footpaths and Separators (Construction of footpath/separator by providing a 150 mm compacted granular sub base as per clause 401 and 25 mm thick cement concrete grade M15, over laid with precast concrete tiles in cement mortar 1:3 including provision of all drainage arrangements but excluding kerb channel.) 40mm thick C.C JH RCD SOR 4.16
Add 18% GST :
Add 1% Labour Cess:
Ms Mohan Lal Jain
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid