Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.7 LAccepted-AOC NEAR LIC OFFICE KALAIGNAR ARIVALAYAM SHOP ROOM NO7 GROUND FLOOR OF BACK SIDE PHOENIX BAY SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹51.1 L+₹2.7 L (5.69%)Rejected-Finance 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 3 | L3₹54.8 L+₹6.4 L (13.3%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 4 | Rejected-Technical PB NO 809 ABERDEEN BAZAR PO ATLANTA POINT NEAR POLICE WIRELESS PORT BLAIR 744104 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744104 | - | Rejected-Technical not enlisted in appropriate class | |
| 5 | Rejected-Technical | - | Rejected-Technical not enlisted in appropriate class |
| Sl No | Description | Qty | Unit | Tropical Refrigeration L2 | RK TRADERS L1 | MGP Enterprises L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for descaling the shell and tube condenser of 50TR (4x12.5TR) capacity chiller of AC plant by circulating the descaling chemical (scale gun/ HCL acid) through condenser tube by pressure feeding method after disconnecting condenser water lines and opening the end covers of both side, brushing condenser water tubing, removing the scales, normalising the copper surface by circulating chemical agent, refixing/ assembling all dismantled parts, replacing gasket set, etc., testing, running the system to the required cooling effect and painting the condenser with two coats of synthetic enamel painting,complete to the entire satisfaction of the Engineer-in-Charge complete all as specified and as directed. | 2 | Each Job | 12,000 ₹24,000 Lowest | 12,000 ₹24,000 Lowest | 12,950 ₹25,900 |
| 2.00 | Disconnecting /removing of defective compressor unit from the chiller unit after carefully disconnect the electric wires and gas pipe line and repalcement with new screw/ scroll type compressor, hermetically sealed suitable for 12.5TR capacity :
Make : Danfoss, Model No. SZ185S4RC | 1 | Each Job | 1,72,000 ₹1,72,000 Lowest | 1,75,000 ₹1,75,000 | 1,95,000 ₹1,95,000 |
| 3.00 | M&L for cleaning/ servicing the AHU of AC plant, 13000CFM capacity by pressure air method using air blower and cleaning 6 rows of chilled water cooling coil section 12 FPI with cleaning solution, descaling by chemical agent, cleaning the AHU filter by using high pressure air, greasing to AHU blower shaft/ motor bearing for smooth functioning, cleaning the AHU base tray, etc., complete to the entire satisfaction of the Engineer-in-Charge all as specified and as directed. | 2 | Each Job | 6,500 ₹13,000 | 5,000 ₹10,000 Lowest | 6,350 ₹12,700 |
| 4.00 | Material & Labour, spray painting of Central AC plant with 2 No 2x50TR, suction, discharge and liquid line, chiller, water lines in cooling tower basin by removing peeled off old paint with scrapper including writing SM No./Ser No. and painting with two coats of synthetic enamel paint of 1st quality as per standard shade and colour, complete all as specified and directed. | 2 | Each Job | 6,500 ₹13,000 | 5,000 ₹10,000 Lowest | 6,350 ₹12,700 |
| 5.00 | M&L for pressure leakage testing of complete system of Central AC plant using dry Nitrogen gas by isolating the cooling coil from both ends of high side and low side, pumping down the refrigerant gas, keeping in safe condition for refill, charging the dry nitrogen gas for pressure leak test, after detecting leak point release the nitrogen gas, rectifying the leak point by means of soldering/ brazing and connecting the cooling coil with system, vaccumised the complete system and re-charge the system by refrigerant, top up of additional quantity of refrigerant gas if required, etc., including testing and commissioning to the required cooling effect complete to the entire satisfaction of the Engineer-in-Charge all as specified and as directed.
Notes :- (a) Cost of Nitrogen gas required shall deemed to be included in the quoted rate. (b) Refrigerant gas required shall be measured and paid separately under respective item of this Schedule. | 2 | Each Job | 28,000 ₹56,000 | 25,000 ₹50,000 Lowest | 29,500 ₹59,000 |
| 6.00 | M&L for repair/ servicing Centrifugal pump set10HP capacity, three phase, 50 C/S by disconnecting/ dismantling (electrically & mechanically) and transporting to workshop, opening the motor, cleaning, greasing to bearing/ bushes, replacing worn out bearings, nuts & bolts, dismantling/ taking down burnt out winding, rewinding the motor with same guage, weight and same number of turns of super-enamelled Copper wire and varnishing compound including heating and re-assembling the motor, brought back to site, refixing at its original position/ location with proper alignment including painting the pump with two coats of synthetic enamel painting, connecting, testing and commissioning after repair, etc., complete to the entire satisfaction of the Engineer-in-Charge all as specified and directed. Notes : (i) Bearing shall be measured and paid for separately as "supply only" under respective items of this schedule. | 2 | Each Job | 38,000 ₹76,000 | 35,000 ₹70,000 | 33,300 ₹66,600 Lowest |
| 7.00 | M&L for servicing of Centrifugal pump set 10HP capacity by disconnecting/ dismantling (electrically & mechanically) and transporting to workshop, opening the pump motor, cleaning the pump, removing scales, greasing to bearing/ bushes, replacing the worn out bushes, bearings, gland rope, gland nut & bolts, painting the pump with two coats of synthetic enamel painting, re-assembling the pump, brought back to site, fixing it at its original location with proper alignment including connecting, testing and commissioning, etc., complete all as specified and as directed.
Note : Bearing shall be measured and paid for separately as "supply only" under respective items of this schedule. | 3 | Each Job | 31,000 ₹93,000 Lowest | 35,000 ₹1,05,000 | 33,300 ₹99,900 |
| 8.00 | Supply only bearing suitable for 10HP three phase motor of Centrifugal pumpset complete all as specified and as directed. | 6 | Each | 10,000 ₹60,000 | 6,500 ₹39,000 Lowest | 9,500 ₹57,000 |
| 9.00 | Supply and top up Regrigerant gas R-407 C in manufacturer's sealed cylinder complete all as specified and as directed. | 90 | KG | 2,100 ₹1,89,000 Lowest | 2,300 ₹2,07,000 | 2,450 ₹2,20,500 |
| 10.00 | M&L for charging of refrigerant gas R-22 for Air conditioners of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed. | 180 | Kg | 1,920 ₹3,45,600 | 1,850 ₹3,33,000 Lowest | 1,950 ₹3,51,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
26 Jun 2025, 6:00 pmClosed
GE Brichgunj SVP
GE Brichgunj SVP
REPAIR MAINT AND SERVICING OF CENTRAL AC PLANT UNDER GE BRICHGUNJ SVP AND REPAIRS AND MAINT OF SPLIT WINDOW AC REFRIGERATOR DEEP FREEZERS WATER COOLERS FANS GEYSERS AND OTHER ACCESSORIES UNDER GE BRICHGUNJ SVP
2025_MES_712608_1
8625A
Open Tender
Civil Works
Item Rate
330 days
GE Brichgunj SVP
Class D a i
9 documents required · 9 mandatory
₹500
Yes
GE Brichgunj SVP
₹98,000
Yes
30 Sept 2025
5 Jun 2025
28 Jun 2025
5 Jun 2025
26 Jun 2025
20 Jun 2025
Amount
M&L for descaling the shell and tube condenser of 50TR (4x12.5TR) capacity chiller of AC plant by circulating the descaling chemical (scale gun/ HCL acid) through condenser tube by pressure feeding method after disconnecting condenser water lines and opening the end covers of both side, brushing condenser water tubing, removing the scales, normalising the copper surface by circulating chemical agent, refixing/ assembling all dismantled parts, replacing gasket set, etc., testing, running the system to the required cooling effect and painting the condenser with two coats of synthetic enamel painting,complete to the entire satisfaction of the Engineer-in-Charge complete all as specified and as directed.
Disconnecting /removing of defective compressor unit from the chiller unit after carefully disconnect the electric wires and gas pipe line and repalcement with new screw/ scroll type compressor, hermetically sealed suitable for 12.5TR capacity : Make : Danfoss, Model No. SZ185S4RC
M&L for cleaning/ servicing the AHU of AC plant, 13000CFM capacity by pressure air method using air blower and cleaning 6 rows of chilled water cooling coil section 12 FPI with cleaning solution, descaling by chemical agent, cleaning the AHU filter by using high pressure air, greasing to AHU blower shaft/ motor bearing for smooth functioning, cleaning the AHU base tray, etc., complete to the entire satisfaction of the Engineer-in-Charge all as specified and as directed.
Material & Labour, spray painting of Central AC plant with 2 No 2x50TR, suction, discharge and liquid line, chiller, water lines in cooling tower basin by removing peeled off old paint with scrapper including writing SM No./Ser No. and painting with two coats of synthetic enamel paint of 1st quality as per standard shade and colour, complete all as specified and directed.
M&L for pressure leakage testing of complete system of Central AC plant using dry Nitrogen gas by isolating the cooling coil from both ends of high side and low side, pumping down the refrigerant gas, keeping in safe condition for refill, charging the dry nitrogen gas for pressure leak test, after detecting leak point release the nitrogen gas, rectifying the leak point by means of soldering/ brazing and connecting the cooling coil with system, vaccumised the complete system and re-charge the system by refrigerant, top up of additional quantity of refrigerant gas if required, etc., including testing and commissioning to the required cooling effect complete to the entire satisfaction of the Engineer-in-Charge all as specified and as directed. Notes :- (a) Cost of Nitrogen gas required shall deemed to be included in the quoted rate. (b) Refrigerant gas required shall be measured and paid separately under respective item of this Schedule.
M&L for repair/ servicing Centrifugal pump set10HP capacity, three phase, 50 C/S by disconnecting/ dismantling (electrically & mechanically) and transporting to workshop, opening the motor, cleaning, greasing to bearing/ bushes, replacing worn out bearings, nuts & bolts, dismantling/ taking down burnt out winding, rewinding the motor with same guage, weight and same number of turns of super-enamelled Copper wire and varnishing compound including heating and re-assembling the motor, brought back to site, refixing at its original position/ location with proper alignment including painting the pump with two coats of synthetic enamel painting, connecting, testing and commissioning after repair, etc., complete to the entire satisfaction of the Engineer-in-Charge all as specified and directed. Notes : (i) Bearing shall be measured and paid for separately as "supply only" under respective items of this schedule.
M&L for servicing of Centrifugal pump set 10HP capacity by disconnecting/ dismantling (electrically & mechanically) and transporting to workshop, opening the pump motor, cleaning the pump, removing scales, greasing to bearing/ bushes, replacing the worn out bushes, bearings, gland rope, gland nut & bolts, painting the pump with two coats of synthetic enamel painting, re-assembling the pump, brought back to site, fixing it at its original location with proper alignment including connecting, testing and commissioning, etc., complete all as specified and as directed. Note : Bearing shall be measured and paid for separately as "supply only" under respective items of this schedule.
Supply only bearing suitable for 10HP three phase motor of Centrifugal pumpset complete all as specified and as directed.
Supply and top up Regrigerant gas R-407 C in manufacturer's sealed cylinder complete all as specified and as directed.
M&L for charging of refrigerant gas R-22 for Air conditioners of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed.
M&L for charging of refrigerant gas R-32 /R-410 (a) for water cooler of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed.
M&L for charging of refrigerant gas R-134 (a)/ R-600 (a) in Refrigerator of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed.
Supply and top up compressor oil in 10 ltrs pack suitable for compressor of Model SZ 185 complete all as specified and as directed.
S&F in repair/ replacement of LP/ HP combination cut out/ cut off switch, type MP-15 suitable for working on R-407C gas complete with flare nut complete all as specified and as directed. [Make : Danfoss]
S&F in repair/ replacement of oil pressure control/ cut off switch, type MP-55 suitable for R-407C complete with flare nut complete all as specified and as directed. [Make : Danfoss]
S&F in repair/ replacement of water pressure cut out 1 PS-70 complete all as specified and as directed.
S&F in repair/ replacement of pressure gauge of LP/ OP (low pressure/ oil pressure) size 4"dia of rating 30 to 150 PSI suitable for working on R-407C gas complete with flare nut complete all as specified and as directed.
S&F in repair/ replacement of high pressure [HP] gauge of dial size 4" dia of rating 0-300kg/sqcm PSI suitable for working on R-407C gas complete with flare nut complete all as specified and as directed.
S&F in repair/ replacement of water pressure gauge of dial size 4" dia of range 0-7 kg/sqcm or 0-100 PSI rating complete all as specified and as directed.
S&F in repair/ replacement of thermostatic expansion valve of suitable flare size including brazing, welding work, etc. for 50Ton chiller plant all as specified.
S&F in repair/ replacement of Thermostat unit in Central AC plant 50TR capacity suitable on working 10˚C to 30˚Cas per OEM.
S&F in repair/ replacement of Humidistat unit in Central AC plant 50TR capacity suitable for 0 to 100% as per OEM.
S&F in repair/ replacement of Outlet Water Temperature sensor suitable for chiller of AC plant. [Model No.XWC4S-052 A RII]
S&F in repair/ replacement of 3 pole Power Contactor type MNX 18 with coil voltage 230Volts, AC suitable for compressor motor in AHU of Central AC plant all as specified and as directed.
S&F in repair/ replacement of overload relay, direct mounting type suitable for relay range of Amps 14 to 23 Amps.
S&F in repair/ replacement of Push Button suitable for Star Delta Starter complete all as specified and as directed
S&F in repair/ replacement of Neon Indicating Lamps 230Volts AC supply complete all as specified and as directed
M&L for checking of leakage in the chilled water pipeline at all joints and valves and arrest the leakage by replacing the gasket and tightening of nuts & bolts complete all as specified and as directed.
M&L in repair/ replacement MS tubing with all MS fittings such as bends, tees, reducers, etc., in any length, necessary leak proof welding work, etc., pressure testing, washing out of the pipeline including taking up or down unserviceable corroded MS water/ air mains with all fittings, complete all as specified and as directed. 100mm bore
&L in repair/ replacement MS tubing with all MS fittings such as bends, tees, reducers, etc., in any length, necessary leak proof welding work, etc., pressure testing, washing out of the pipeline including taking up or down unserviceable corroded MS water/ air mains with all fittings, complete all as specified and as directed. 50mm bore
S&F in replacement, gun metal, globe or gate valves, ISI marked, suitable for 50mm bore with iron wheel head, screwed both ends and fixed including taking down old unserviceable gun metal, globe or gate valve complete all as specified and as directed.
S&F AC thermal insulation for air ducting using 25mm thick fibre glass wool of density 24kg/cum including dismantling air duct and refixing complete all as specified and as directed.
Supply and fix MCCB three pole 160 A 25 kA complete all as specified and as directed.
S&F in replacement, Cast Iron Butterfly valve suitable for 100mm bore pipe confirming to IS 13095 with provision of suitable GI flanges, nuts, bolts, double washers, rubber gaskets including taking out old unserviceable valve, etc., complete all as specified and as directed.
S&F in repair/ replacement of Blower Motor 10 HP for AHU 13000 CFM capacity AC plant including taking down old unserviceable blower motor all as specified and as directed.
S&F in repair/ replacement of fan motor 3 HP for Cooling Tower 50TR capacity including taking down old unserviceable fan motor all as specified and as directed.
Disconnecting and removing unserviceble Star-Coupling assembly set from the pump-motor drive system, supply and fixing new Star-Coupling set, sizes of 100/110 with nuts, bolts including making lathe machine work ,alignment and testing complete all as specified and directed.
Disconnecting and removing unserviceble Rubber Star-Coupling from the pump-motor drive system, supply and fixing rubber Star-Coupling sizes of 100/110 with nuts, bolts including making alignment and testing complete all as specified and directed
Supply only Pillow block bearing suitable for 10 HP pump . Make : SKF/NBF complete all as specified and as directed.
S&F cooling fan vanes for morots of various capacity.
Supply and fix mechanical sealing for pump of capacity upto 10 HP
Taking down shaft from various type /capacity of pump set/ motor/ monoblock, fill welding, re-melting & turning of shaft in lathe machine and testing of machines all as specified and directed.
Disconnecting and removing unserviceable Chilled Water Sensors from the chiller and S&F new Chilled Water Sensor including connecting and testing complete all as directed. Make : Voltas/Bluestar/York/Trane/Dananbush
Removing unserviceable existing fills from cooling tower and Supply and fix new fills upto 10mm thickness including maintainance of basement of fills of any capacity cooling tower complete all as specified and directed.
Supply and fix as in replacement of Sprinkler assembly/Nozzle assembly with PVC pipes including dummies for 60 TR capacity cooling towers all as specified and directed.
S&F cooling tower fan blades(Cast Metal) including HUB set as per sample.
Taking out unserviceable Pre-filter, Supply and fixing new Pre filter to 20 micron level of approximate size 60 X 60 X 6 Centimeters complete all as directed.
All as per item No 46 above but approximate size of 60 x 30 x 6 CM
All as per item No 46 above but approximate size of 30 x 30 x 6 CM.
Disconnecting and removing the unserviceable burntout Timer, S&F new Star Delta timer 0 to 10 Sec all as directed. Make:- GE /SIEMENS/L&T
Supply only Single Phasing Preventor with auto start ON Delay Timer (Auto Reset, 50Volts Unbalance, 1NO Contact) provision for connection of Auto/Manual switch externally 415V complete all as specified. Make: Minilec/Powertek/GIC/IndoAsian.
Supply only 'V" belts of size A-78 complete all as specified.
Supply only 'V" belts of size B-70 complete all as specified.
Supply and Fix ADD ON Blocks 1NO+1NC complete all as specied and as directed .
M&L for servicing of window type air conditioner of 1.5/2.0 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the unit complete in position all as specified and as directed by Engr-in-Charge.
Dismantling the following unservicable items from window type air conditioner of capacity 1.5/2.0 Ton of any make and any type and replacing the same with new one including testing and commissioning the same all as specified and as directed Compressor under manufacturers exchange scheme.
AC fan motor single phase, 1/5 hp, 1100 rpm, 130 watts, 240 volts
Capacitor 55/ 60 mfd 230 volts
Fan capacitor 5/6 mfd
Blower motor fan blade set
Rubber mounting bush for blower motor
S&F in repairs copper condensor coil suitable for 1.5/2 T Split/window AC complete all as specified and as directed by Engr-in-Charge.
M&L for servicing of split type air conditioner of 2.0 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the cover complete in position all as specified and as directed.
M&L for servicing of split type air conditioner of 1.5 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the cover complete in position all as specified and as directed.
Dismantling the following unservicable items from split type air conditioner of capacity 1.5/2.0/4.0 Ton of any make and any type and replacing the same with new one including testing and commissioning the same all as specified and as directed Compressor for 1.5 ton split type air conditioner under manufacturers exchange scheme.
Compressor for 2.0 ton split type air conditioner complete in position all as specified and as directed.
Compressor for 4.0 ton split type air conditioner complete in position all as specified and as directed.
Blower motor for 1.5 ton split type air conditioner
Blower motor for 2.0 ton split type air conditioner
Condensor motor
Capacitor for 2.0 ton split type air conditioner, 55/60 mfd 230 volts
Capacitor for 1.5 ton split type air conditioner, 45/50 mfd 230 volts
Blower Fan capacitor 3/4/5 mfd
PCB Electronic control board for 1.5/2.0 ton split type air conditioner
Insulation rubber hose 12mm for split AC any type
Hand Remote set for 1.5/2.0 ton split type air conditioner as per OEM
Outer brass valve of size 5/8" for out door unit of split AC 2 ton
Outer brass valve of size 3/8" for out door unit of split AC 2 ton
Outer brass valve of size 1/2" for out door unit of split AC 1.5 ton
Outer brass valve of size 1/4" for out door unit of split AC 1.5 ton
Powder coated MS Stand for outer unit of split AC 1.5/2 ton capacity.
Expansion valve with capillary for window/split type AC
Dismantling the following unservicable items from water cooler storage type 40/80 and 60/120 ltrs cooling of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed Compressor under manufacturers exchange scheme 60/120 Ltrs capacity.
Compressor under manufacturers exchange scheme 40/80 Ltrs capacity.
Fan motor 60/120 ltrs capacity.
Fan motor 40/80 ltrs capacity.
Thermal over load protector 40/80 ltrs capacity.
Starting relay 40/80 and 60/120 ltrs capacity.
Thermostat 40/80 and 60/120 ltrs capacity.
Starting capacitor 80/100 mfd 230 volts
Running capacitor 10 mfd 230 volts
Self closing tap of chromium plated brass, size 15mm
Expansion valve with capillary for water cooler
Condenser coil
Aluminium cooling coil/Freezer coil
Dismantling the following unservicable items from Refrigerator 175 to 220 Ltrs capacity of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed Compressor under manufacturers exchange scheme.
starting relay
Aluminium cooling coil/Freezer coil
condensor coil
Thermostat
Limit Switch
Fan motor
Timer
Bimetal
Expansion valve with capillary for refrigerator
Dismantling the following unservicable items from Refrigerator 280 to 310 Ltrs capacity of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed Compressor under manufacturers exchange scheme.
starting relay
Aluminium cooling coil/Freezer coil
condensor coil
Thermostat
Dismantling the following unservicable items from deep Freezer 200/400 Ltrs capacity of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed Compressor under manufacturers exchange scheme.
starting relay
Thermostat
Starting capacitor for deep Freezer, 80/100 mfd 230 volts
Running capacitor for deep Freezer, 40/60 mfd 230 volts
Taking down unserviceable Split AC 1.5 Ton/2 Ton indoor and outdoor unit and deposit same at E&M store for repair and refixing serviceable unit issued by department complete in position all as specified and as directed. Note:- Transportation for deposit and collection shall be deemed to be included in quoted rate
Supply and fix in repair of 3 core 1.5sqmm copper cable.
M&L for pressure testing the compressor unit including connecting pipe line with nitrogen gas and holding the appropriated pressure for approved period (as per manufactureal instruction) and rectify the leakages by means of welding, soldering/brazing etc for window/splitt type air conditioner/ water cooler/refrigerator of any capacity and make, including testing and commissioning complete all as specified and as directed.
M&L Repair to voltage stabilizer 5.0/4.0 KVA capacity AC, SP 240 volts including replacement of relays and electronic printed circuit board (PCB) with brand new relays & PCBs and testing on completion all as specified and as directed.
M&L Repair to voltage stabilizer 0.5 to 3 KVA capacity AC, SP 240 volts including replacement of relays and electronic printed circuit board (PCB) with brand new relays & PCBs and testing on completion all as specified and as directed.
S & F in repair of 20 A MCB DB BOX COMBO Plastic Enclosure modular type complete with one MCB, SP, 20 Amps, 240 Volts fixed complete all as specified and as directed.
Supply and fix in repair earthed plug top 20 Amps capacity with sheet metal enclosure including 20A MCB all as specified and directed.
M & L for sub main wiring with 3 runs (Phase, neutral, earth) of 4 Sq.mm PVC Insulated Unsheathed single core cable, 1100 Volts Grade Multistranded with Copper Conductor drawn through and including PVC Casing and Caping (or) PVC conduit of 20mm dia non metalic rigid with conduit accessories fixed to walls/roofs/floors etc all as specified and as directed by Engr-in-Charge.. (Note: 2 runs of 4 Sq.mm & 1 run of 4 Sq.mm earth conductor will be measured as one running metre)
Supply and fix in repair of PVC conduit 20mm for drain out of air conditioner filled with clamps on wall's complete all as specified and as directed.
Supply and fix in repair copper tube of size 5/8 with insulation rubber hose, complete all as specified and as directed.
Supply and fix in repair copper tube of size 1/2 with insulation rubber hose, complete all as specified and as directed.
Supply and fix in repair copper tube of size 3/8 with insulation rubber hose, complete all as specified and as directed.
Supply and fix in repair copper tube of size 1/4 with insulation rubber hose, complete all as specified and as directed.
Taking down storage type water heater of 50 ltrs capacity of any make and any type and disconnecting inlet/outlet pipe connections complete, including dismantling and servicing, leak testing cleaning storage tank completly and refixing the same in position with suitable nuts and bolts and connecting inlet/outlet connections including testing and commissioning all as specified and as directed. Note:- Spares required replacement shall be measured and paid separately.
All as per item No 78 above but water heater of 25 litres capacity csd.
S&F in repairs Heating element of 1500 watts, 240 volts suitable for existing complete all as specified and as directed.
S&F in repairs Heating element of 2000 watts, 240 volts suitable for existing complete all as specified and as directed.
S&F in repairs Thermostat element suitable for 25/50 ltrs capacity water heater, suitable for existing complete all as specified and as directed.
S&F in repairs Geyser "Hot & Cold" PVC pipe connection with brass nuts 450mm length all as specified and as directed.
Dismantling the celing fan, removing burnt out winding complete and cleaning the internal slots of rotor with ring and rewinding with new rotor shaft the ceiling fan of size 1200mm/1400mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling complete all as specified and as directed.
Supply and fix in repair of ball bearing suitable for ceiling fan of any sweep and make complete all as specified and as directed.
Supply and fix in repair ceiling fan condensor 2.5 mfd AC 240 volts 50 Hz complete all as specified and as directed.
Tropical Refrigeration (BID ID -3337612)
MGP Enterprises (BID ID -3338004)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .