Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.6 L+₹29,719 (12.7%)Rejected-Finance 482 GALI NO 4 TULSI VIHAR AZAD NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | L2 | Rejected-Finance L2 |
Tender Value
₹2.6 L
EMD Value
₹5,122
Closing Date
29 Dec 2020, 5:00 pmClosed
Executive Engineer Electrical PWD Band R Br, Hissa
Executive Engineer Electrical PWD Band R Br, Hissar
CONSTRUCTION OF NEW RESIDENTAIL HOUSES AT CHC AT JAKHAL IN DISTT. FATEHABAD (PDG. STREET LIGHT ONLY).
2020_HRY_152441_2
PWD/Elect-GGN/Elect-HSR/100102
Open Tender
Electrical Works
Works
120 days
Hisar
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹5,122
24 Feb 2021
21 Dec 2020
30 Dec 2020
21 Dec 2020
29 Dec 2020
21 Dec 2020
Amount
(a) Main Switches: Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections . (HSR 31.12) (v) Double pole switch 32 amp. 415 Volts Cat-B,
(L) Miniature Circuit Breaker and Isolator.: Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. (HSR 31.17) (a) Miniature circuit breakers of 9 KA breaking capacity. (ii) SP MCB 6 amp. to 32 amp.
(iii) SPN MCB 6 amp. To 32 amp.
(P) Pipe Laying.: Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. (HSR 31.21) (xii) Galvanized iron pipe 40 mm dia on flushed.
(Q) Earthing (HSR 31.22): (i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
(ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
(xix) Supply and erection of 20 mm x 3 mm thick G.I. tape fixed with suitable G.I. staples of same size.
Supply and erection of under ground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. (xxxix) 10 Sq. mm 4 Core Ard. Cable . (HSR 31.25)
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . (HSR 31.26) (iv) 10 Sq. mm 2 Core Ard. Cable.
(v) 16 Sq. mm 2 Core Ard.Cable.
Supply and erection of suitable compression type brass cable glands for underground Cable. (HSR 31.28) ii) 10 Sqmm to 16 Sqmm Cable 2 to 4 Core .
S/E of PVC unsheathed copper conductor cable single core 1100 volts grad in pipe of suitable size excluding cost and erection of pipe. (HSR 31.40) i) Cable size 1.5 sqm(3/0.81 mm)
Supply and errection of Hot Dip Galvanized octagonal pole 3 mm thickness, with base plate including of nut and bolts and all accessories as supplied by the manufacture including cost of foundation accessories etc. The foundation bolts as per manufacturer design should be hot dipped galvanized pole complete of 2 nos. 100 A, 4 pole nature links including connection etc with suitable connection arrangements for 2 no. MCB/ kit kat including cost of RCC 1:1:5:3 for foundation of size 0.7 m x 0.7m x 1.8 m with minimum 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm CC for fixing the pole with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make:Philips/ Bajaj/ Volmont/ Skipper/ Vipin ST-poles. (HSR 31.68) i) 7 M long pole with top dia 70 mm and bottom dia 130 mm with base plate of size 220 x 220 x 12mm.
Non Schedule Item: Supply & Erection of Single arms bracket made of 32/50mm dia GI pipe B class ISI 1.20 mtr. Long with coller pipe (GI) 75mm dia 60cm Long top covered with ornamental cap duly welded, painted 2 coats of aluminum paints on bracket and golden paint of ornamental cap including the cost of labour and petty material etc. complete in all respect upto the entire satisfaction of Engineer-incharge. Bracket duly erected on existing 7/9 Mtr. High Octagonal pole.
Non Schedule Item: S/E of 60 W LED street light fitting < 120 Lumens per Watt Philips / Havell's /Bajaj/ Wipro make in aluminum pressure die casting housing toughened glass cover with IP-66 protection With Lense and dual surge protection device internal 5 KV and external 10 KV including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work.
Virender Singh prop. Balaji electric company
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .