| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹18.4 L+₹62,729 (3.53%)Rejected-Finance | L2 | Rejected-Finance Not a lowest bid | |
| 3 | L3₹18.7 L+₹97,554 (5.49%)Rejected-Finance | L3 | Rejected-Finance Not a lowest bid | |
| 4 | L4₹19.3 L+₹1.5 L (8.60%)Rejected-Finance | L4 | Rejected-Finance Not a lowest bid | |
| 5 | L5₹22.9 L+₹5.1 L (28.8%)Rejected-Finance 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L5 | Rejected-Finance Not a lowest bid |
Tender Value
Refer Docs
EMD Value
₹49,000
Closing Date
17 Sept 2020, 6:00 pmClosed
GE MCEME SECUNDERABAD
GE MCEME SECUNDERABAD MCEME CAMPUS TRIMULGHERRY SECUNDERABAD 500015
REPAIRS REPLACEMENT OF UNSERVICEABLE ELECTRICAL WIRING AND CONNECTED ITEMS OF ZONE I AREA UNDER GE MCEME SECUNDERABAD
2020_MES_370132_1
GE/MCEME/07 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
SECUNDERABAD
as per NIT
7 documents required · 7 mandatory
₹500
GE MCEME SECUNDERABAD
₹49,000
Yes
2 Dec 2020
18 Aug 2020
19 Sept 2020
18 Aug 2020
17 Sept 2020
4 Sept 2020
Amount
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / Hylam sheet/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on conduit including removal of batten / Hylam sheet/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked of suitable dia, surface conduit wiring on walls including Tee, Junction boxes and provision of 2.0mm thick MS terminal boxes duly painted with red oxide metal primer and covered with 3 mm thick sheet cover of suitable size including suitable screws with washer for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly complete all as specified & as directed for One light point controlled by one, one way switch 5 amps, SP
All as per item No. 3 above but for One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
All as per item No. 3 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per item No. 3 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 3 above but for One light point controlled by two 2 - way switch 5 amps, SP
All as per item No. 3 above but for One Bell point controlled by one bell bush switch 5 amps, single pole
All as per item No. 3 above but using 2.5 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps switch socket combination point including running 2.50 Sqmm copper conductor PVC wire as earth continuity conductor on independant board.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through any type of existing concealed/ surface conduit wiring and utilise the exiting MS terminal boxes duly painting reuqired with red oxide metal primer , covered with 3 mm thick sheet cover of suitable size including suitable screws with washer for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly complete all as specified & as directed for One light point controlled by one, one way switch 5 amps, SP
All as per item No. 10 above but for One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
All as per item No. 10 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per item No. 10 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 10 above but for One light point controlled by two 2 - way switch 5 amps, SP
All as per item No. 10 above but for One Bell point controlled by one bell bush switch 5 amps, single pole
All as per item No. 10 above but using 2.5 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps switch socket combination point including running 2.50 Sqmm copper conductor PVC wire as earth continuity conductor on independant board.
S & F of Switch piano , single pole one way, flush type 5 Amps capacity 230 volts complete all as specified.
S & F of Switch piano , single pole two way, flush type 5 Amps capacity 230 volts complete all as specified.
S & F of bell push of 5 amps, single pole flush type complete all as specified and as directed.
S & F electric bell of 230 Volts AC single pole complete all as specified and as directed.
S & Fof switch socket combination 2 in 1 multipurpose 2/3 pin 5 amps flush type complete all as specified.
S & F switch socket combination 2 in 1 multipurpose 3pin 5/15 amps flush type complete all as specified.
S & F of electronic ceiling fan regulator stepped type heavy duty suitable to work on 230 volts complete all as specified.
S & F of lamp holder insulated body with black plate for angle/batten fittings fixed with PVC round blocks complete all as specified.
S & F of ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified.
S & F in repairs of Modular switches 1M 6 A, with suitable modification in the existing switch board.
S & F in repairs of Modular switches 1M 16 A, with suitable modification in the existing switch board.
S & F in repairs socket modular type multipurpose 2/3 pin 6 amps 2 in 1 230 Volts all as specified.
S & F in replair socket 2 in 1 multipurpose 3/5 pin 6/16 Amps modular type with complete all as specified.
S & F in repairs of electronic ceiling fan regulator stepped modular type heavy duty suitable to work on 230 volts complete all as specified.
Supply and replace of capacitor 2.15 Mfd for ceiling fan.
S&F sheet metal enclosure with 2 pole and Earth Metal Plug & Socket including 20A SP MCB complete including taking down unserviceable enclosure all as directed by Engr in Charge.
Supply and replace Industrial laminated hylam sheet 3 mm thick ISI marked cutting to required size and shape suitable to fittings of 250 mm x 200 mm size
Supply and replace Industrial laminated hylam sheet 3 mm thick ISI marked cutting to required size and shape suitable to fittings of 175 mm x 100 mm size
M & L Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length.
M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length.
M & L Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through existing conduit and conduit accessories including one run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Two runs of cable and one run of earth contuinity conductor shall be measured as one unit length.
M & L Submain wiring with 4 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 32 mm dia including two run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Four runs of cable, two run of earth contuinity conductor and one run of conduit shall be measured as one unit length.
S&F PVC casing capping of 25 mm size all as specified and directed.
S&F in repairs of PVC insulated unsheathed multistranded 1100 volts grade with copper conductor of size 1.5 Sqmm all as specified and as directed
S&F in repairs of PVC insulated unsheathed multistranded 1100 volts grade with copper conductor of size 2.5 Sqmm all as specified and as directed
S & F in repair Flexible cord with copper conductor multistanded Twin core 23 / 0.198 size all as specified and directed.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of andings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
Supply & replace of Vertical type MCCB TPN DB 4 way double door with incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA with adjustable thermal setting for current capacity 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S
Supply and replace MCB DB double door TPN 4 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface.
Supply and replace MCB double door DB SPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface.
Supply and replace MCCB 415V,16KA, 125 amps suitable for TPN DB .
S & F in repair MCB TPN, 63 Amps, 415 volts C series complete all as specified and directed
S & F in repair MCB SPN 32 Amps 240 volts C series for fixing on MCB DB.
S & F in repair MCB SP 6 to 32 Amps 240 volts C series for fixing on MCB DB.
Supply & replace old unserviceable 36W tube light with double side/single side connection LED retrofit type polycarbonate lamp with integrated electronic drive of 18 Watt of 6500 K colour temp. complete all as specified and directed . Make : C&S/Havells/Wipro/Philips
S & F LED tube light fitting retro type single tube 1x20/18watts 230 volts complete with all accessories , prewired fixed to wall/ceiling with 2 Nos round blocks with necessary hanging/fixing arrangements & connecting to the point wiring with necessary flexible copper conductor of multisranded three core of suitable length from fitting to the ceiling rose in and including polycarbonate LED tube of capacity 18 W complete all as specified. Make: C&S/Havells/Wipro/Philips
S & F LED batten with polycarbonate housing and integrated electronic drive of 18 Watt of power factor >.95, 6500 K colour temp. working at single phase all as specified and directed . Make : C&S/ Havells/WIPRO/Philips
Supply and replace old unserviceable false ceiling fitting with ultra modern recess mounted LED luminaire 36 watts suitable for armstrong grid /POP ceiling of 2'x2' and complete with suitable aluminium frame for POP/Gypsum board 2x2 panel light,including electronic driver. Make: WIPRO/ C&S /Havells/Philips
Supply and replace old unserviceable light fitting with ultra modern surface mounted LED luminaire 36 watts 2x2 panel light,including electronic driver. Make: WIPRO/Philips/ C&S /Havells
Supply and replace old unserviceable false ceiling fitting with ultra modern reces mounting LED luminaire suitable for armstrong grid /POP ceiling of 1'x1' including electronic driver complete all as specified and directed. Make:HAVELLS / WIPRO/ C&S /Philips
Supply & Replace old unserviceable old 11/18 CFL fittings with LED surface mounted downlight with white powder coated polycarbonatehousing and pressure die-cast heat sink having high efficiency of capacity 15 Watt fitting. MAKE : Havells/Wipro/C&S/Philips
Supply and replace old unsv builiding security light of any capacity with energy saving LED security light fittings of 20Watt capacity complete. WIPRO/Philips/Havells/C&S
S & F in repair G.I. pipe bracket 25 mm dia including clamp, bolts and nuts for fixing the building security light
Supply and replace LED electronic driver suitable for 36/42 Watts capacity 2X2 LED fitting all as specified and directed.
Supply and replace LED electronic driver suitable for 10/12/15 Watts capacity downlight fitting all as specified and directed.
Supply and replace unserviceable PVC air ventilators of size 200/250 mm sweep operated at 230 volts all as specified and as directed by Engineer-In-Charge.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, checknuts and washers all as shown in Electrical Plate No.3 of SSR Part-I and connected to main switch board including excavation and earth work, PCC chamber in 1:3:6, RCC Cover in 1:2:4 type B-1 reinforced with 8 mm dia MS bars at 10 cm c/c, 20 mm dia medium grade GI pipe with funnel and wire mesh complete and watering arrangement all as specified. (Note: GI pipe 15mm dia, GI wire 4mm dia upto 7.5m deemed to be included in quoted rate.)
MVS ENTERPRISES
SUN LIGHT HOUSE
gsrinivasarao
STANDARD AGENCIES
Sri Associates
diesel power services (a.p)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .