Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹37.9 L+₹2.0 L (5.69%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 3 | L3₹38.7 L+₹2.8 L (7.76%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 4 | Rejected-Technical 111 YADAV ELECTRIC MARKET G B MARG LATOUCHE ROAD LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | - | Rejected-Technical CRITERIA NOT FULFILLED AS PER NIT | |
| 5 | Rejected-Technical | - | Rejected-Technical CRITERIA NOT FULFILLED AS PER NIT |
| Sl No | Description | Qty | Unit | H C CONSTRUCTION L3 | Industrial Traders L1 | M/s R K Associates L2 |
|---|---|---|---|---|---|---|
| 1.00 | Roughening surfaces of old concrete floor/terrace by picking including taking down existing detoriated / decayed tar felt or any other treatment including roof tiles etc. loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. and removing the scraped materials/debris to a distance not exc. 100 metres including loading/unloading and removing to a place complete all as specified and directed. | 530 | Sqm | 35.31 ₹18,713.24 | 33 ₹17,490 Lowest | 34.63 ₹18,353.37 |
| 2.00 | Material and Labour for PCC 1:2:4 type B-0 using (12.5 mm graded stone aggregate) as in padding on roof top including WPC as per manufacturers instructions to achieve the slope required, with minimum thickness of 25mm consolidated and finished even and fair without using extra cement. (WPC shall be measured and paid separately | 7.5 | Cum | 8,645.42 ₹64,840.62 | 8,013 ₹60,097.5 Lowest | 8,479.16 ₹63,593.68 |
| 3.00 | M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound as per manufacturer instructions on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed. | 530 | Sqm | 211.85 ₹1,12,279.44 | 196 ₹1,03,880 Lowest | 207.77 ₹1,10,120.22 |
| 4.00 | M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following for Non Approachable roofs-
(a) Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/Sqm on top of dry surface of finished cement mortar plaster. | 530 | Sqm | 42.37 ₹22,455.89 | 39 ₹20,670 Lowest | 41.55 ₹22,024.04 |
| 5.00 | (b) One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over primed surfaces. | 530 | Sqm | 65.57 ₹34,753.16 | 61 ₹32,330 Lowest | 64.31 ₹34,084.83 |
| 6.00 | (c) One layer of polymeric water proofing membrane 3mm thick of weight not less than 3.5 kg/Sqm consisting 90 micron thicken of central core shall be unrolled surfaces with lap of 100 mm and the over lap shall be sealed by flame. | 530 | Sqm | 407.56 ₹2,16,004.26 | 378 ₹2,00,340 Lowest | 399.72 ₹2,11,850.33 |
| 7.00 | (d) One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over polymeric membrane. | 530 | Sqm | 65.57 ₹34,753.16 | 61 ₹32,330 Lowest | 64.31 ₹34,084.83 |
| 8.00 | (e) Applying two coats of aluminum paint on top of membrane @ 0.10Kg/Sqm. | 530 | Sqm | 71.62 ₹37,961.14 | 66 ₹34,980 Lowest | 70.25 ₹37,231.12 |
| 9.00 | Repair to Steel rolling shutters, with or with out ball bearing or gear oprated type with bevel gear box and crank handle or with chain wheel and hand chain etc. with minor repairing of hood cover, bracket plate of U camp, lock plate guide, oiling/greasing and with and including repair/replacing of high tensile spring, safety lever locks, ball bearing, pulley etc. complete all as specified and directed. | 20 | Each Job | 5,548.4 ₹1,10,968 | 5,143 ₹1,02,860 Lowest | 5,441.7 ₹1,08,834 |
| 10.00 | Repair/Replacement of Upvc door/Upvc windows of any size not more than 3.00 Sqm (aprox) or as per existing glass door/approved including taking out glazed shutters from frames and refixing in the same opening after servicing with and including replacement of broken or unserviceable pivots, locks, hinges floor spring rubber band and locking arrangement etc making good to obtain smooth opening and closing all adjusment to make the functional. complete all as specified and directed. | 10 | Each Job | 1,513.2 ₹15,132 | 1,403 ₹14,030 Lowest | 1,484.1 ₹14,841 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
20 Oct 2025, 9:00 amClosed
GE(AF)BKTLUCKNOW
GE(AF)BKTLUCKNOW
REPAIR TO ROOF TREATMENT, JOINERY, PLUMBING SANITARY FITTING ETC OTHER CONNECTED REPAIR WORKS, ESSENTIAL REPAIR TO EARTHING INFRASTRUCTURE AND LIGHTING PROTECTION AND REPAIR/ MAINT OF SUMMER COOLING APPLIANCES AT AF STN BKT
2025_MES_733122_1
8814/BKT/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF)BKTLUCKNOW
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(AF)BKTLUCKNOW
₹70,000
14 May 2026
29 Sept 2025
22 Oct 2025
29 Sept 2025
20 Oct 2025
13 Oct 2025
Amount
Roughening surfaces of old concrete floor/terrace by picking including taking down existing detoriated / decayed tar felt or any other treatment including roof tiles etc. loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. and removing the scraped materials/debris to a distance not exc. 100 metres including loading/unloading and removing to a place complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B-0 using (12.5 mm graded stone aggregate) as in padding on roof top including WPC as per manufacturers instructions to achieve the slope required, with minimum thickness of 25mm consolidated and finished even and fair without using extra cement. (WPC shall be measured and paid separately
M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound as per manufacturer instructions on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed.
M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following for Non Approachable roofs- (a) Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/Sqm on top of dry surface of finished cement mortar plaster.
(b) One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over primed surfaces.
(c) One layer of polymeric water proofing membrane 3mm thick of weight not less than 3.5 kg/Sqm consisting 90 micron thicken of central core shall be unrolled surfaces with lap of 100 mm and the over lap shall be sealed by flame.
(d) One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over polymeric membrane.
(e) Applying two coats of aluminum paint on top of membrane @ 0.10Kg/Sqm.
Repair to Steel rolling shutters, with or with out ball bearing or gear oprated type with bevel gear box and crank handle or with chain wheel and hand chain etc. with minor repairing of hood cover, bracket plate of U camp, lock plate guide, oiling/greasing and with and including repair/replacing of high tensile spring, safety lever locks, ball bearing, pulley etc. complete all as specified and directed.
Repair/Replacement of Upvc door/Upvc windows of any size not more than 3.00 Sqm (aprox) or as per existing glass door/approved including taking out glazed shutters from frames and refixing in the same opening after servicing with and including replacement of broken or unserviceable pivots, locks, hinges floor spring rubber band and locking arrangement etc making good to obtain smooth opening and closing all adjusment to make the functional. complete all as specified and directed.
Taking down existing aluminium doors/windows shutter with frame area not exceeding 2 Sqm and re-fixing in same opening after repair/replace the defective parts (any type of aluminium section) complete.Note : Aluminium parts will be measured and paid separately. complete all as specified and directed.
S & F Aluminium anodised or powder coated door, window, ventilator frame with one or more rebates and shutter sliding or casement windows as reqd. including grill, jointing cleat, glazing clips with EDP gasket for fixing, rubber packing etc. complete all as specified and directed.
S&F prelaminated particle board 9 mm thick, interior grade, prelaminated both sides with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
Supply and fixing 4mm thick aluminium composite panel (coloured sheet) and in additional other accessories for fitting complete all as specified and directed.
Hacking out old broken glass up to 9.50 m height (any thickness size, quality or description) from steel, Aluminium or wooden frames, glazed with putty or fixed with beads complete all as specified and directed
S&F 4mm thick plain sheet glass ordinary quality and glazing with oil putty pins/spring pins upto 9.50M height in steel/Aluminium/wooden shutter in square n.exc 0.50 Sqm in each pane or any steel frame including glazing clips, complete all as specified and directed (Make:- Modi Guord/Saint-gobin or equivalent).
S&F 4mm thick frosted glass panes and glazing with oil putty & pins/spring pins upto 9.50M height in steel/Aluminium/wooden shutter in square n.exc 0.50 Sqm in each pane or any steel frame including glazing clips, complete all as specified and directed (Make:- Modi Guord/Saint-gobin or equivalent). complete all as specified and directed.
S&F 5.50 mm thick sheet glass, ordinary quality plain or tinted and glazing with rubber gasket in square exceeding 0.5 Sqm in each pane, complete all as specified and directed.
S&F 12 mm thick toughened glass as in hinged doors, partions automatic doors and similar works including cutting to shape, drilling holes reqd complete all as specified and directed.
S&F in repair mortice Lock with all fittings for aluminium door complete all as specified and directed.. (Make: Godrej/Link/Harrison)
S&F aluminium handle size & shape as per existing handle for aluminium door or 200 mm long etc. complete all as specified and directed.
S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. (Make -Sandhu/Hardwyn/Droma).
S&F in repair door closer hydraulically regulated designation No 3, universal type, suitable for door shutter of weight between 61 to 80 Kg of aluminium (Die cast) body complete all as specified and directed. (Make -Sandhu/Hardwyn/Kelwyn)
M&L two coat of synthetic enamel painting over a coat of pink primer incl preparation of steel new surface over 10 cm width or girth. Complete all as specified and directed.
Dismantling of wall and ceiling boards, any thickness including cover fillets complete all as specified and directed.
Suspended false ceiling system using Chicago metallic (E - grid) exposed suspended system, grid size 600mm x 600mm comprising of GI powder coated Main Runner of dimensions 39mm x 24mm x 0.8 mm thick (Thickness comprising of GI/0.4 mm+ PPPCGS/0.3 mm & weight of runner 1.35 kg for 3600 mm length), Cross Tee of dimensions 29mm x 24mm x 0.8mm thick (Thickness comprising of GI/0.4mm + PPPCGS/0.3mm & weight of Tee 0.195 kg for 600mm length) and Wall angle of dimensions 22.2mm x 22.2mm x 0.65mm thick (Thickness comprising of GI / 0.35mm + PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length) with and including 4mm thick HPSC (High pressure steam cured) pre primed, self embossed, textured designer board to be placed in the grid system duly suspended with 4mm dia GI wire hangers fixed with steel dash through fasteners from purlins with butterfly clips (wt-0.007 kg/clip), hold down clips (wt-0.0035 kg/clip), with provn of light fixture complete all as per manufacturer instructions complete all as specified and directed.
S&F 15mm bore tubes medium grade galvanized with all fittings such as Tees, elbows, unions, sockets, plugs, short Length etc. and fixed complete to walls and ceilings or laid in floors concealed or open of any length including taking down or up old GI tubing complete all as specified and directed.
S&F 20 mm bore tubes medium grade galvanized with all fittings such as Tees, elbows, unions, sockets, short, lengths, plus etc. and fixed complete to walls and ceilings or laid in floors of any length including taking down or up old GI tubing complete all as specified and directed.
S&F in repair 15mm bore bib tap cast copper alloy CP with crutch or butterfly handles screwed down for iron pipes or for brass ferrule complete all as specified and directed. (Make: Jaquar Essco/Cera/Coronet )
S&F in repair 15mm bore pillar taps cast copper alloy chromium plated screwed down high pressure with or without lattered HOT or COLD with long screwed shanks and fly nuts screwed for iron pipes, complete all as specified and directed. (Make: Jaquar Essco/Cera/Coronet)
S&F in repair Brass chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed. (Make: Jaquar Essco/Cera/Coronet)
S&F in repair Brass CP bath Mixer with telephonic hand shower suitable 15mm bore of pipe and fixed. (Make: Jaquar Essco/Cera/Coronet)
S&F in repair 15mm bore angle valves/stop valves cast copper alloy screwed down high pressure with crutch or butter fly handles screwed both ends for iron pipe or for union complete all as specified and directed. (Make: Jaquar Essco/Cera/Coronet)
S&F in repair 15mm bore 2 way angle valves cast copper alloy screwed down high pressure with crutch or butter fly handles screwed both ends for iron pipe or for union complete all as specified and directed. (Make: Jaquar Essco/Cera/Coronet)
S&F in repair chromium plated shower rose fancy type fixed to 15mm bore pipe complete all as specified and directed. (Make: Jaquar Essco/Cera/Coronet )
S&F in repair CP jet spray with flexible tube etc complete all as specified & directed. ( Make: Jaquar Essco/Cera/Coronet)
S&F in repair health faucet (hand shower) (ABS body) with 1.2 mtr long flexible tube and wall hook etc complete all as specified & directed. (Make: Jaquar Essco/Cera/Coronet )
S&F in repair brass chromium plated soap tray/dish fixed with CP screws etc complete all as specified and directed. (Make : Coronet/Jaquar/plumber/Prayag)
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. (Make: Jaquar Essco/Cera/Coronet)
S&F in repair PVC low level flushing cistern of capacity 10 litres complete with siphon handle lever float valve and PVC bend incl connecting to ITWC/ ETWC and fixing on wall bracket complete all as specified and directed. (Make: Jaquar Essco/Cera/Coronet )
S&F in repair 100 mm/ 125mm dia mild steel chromium plated grating fixed on floor trap / nahni trap in Cement mortar 1:6 complete all as specified and directed.
S&F in repair vitreous china squatting pan white orissa pattern size 580 x 440mm with integral foot rests (excluding flushing cistern & flush pipe) with cast iron trap portion to match with the existing surface of floor complete all as specified and directed. (Make:Parryware/Hindware/Jaquar)
S&F in repair vitreous china wash down water closet pan (pedestal pattern) white excluding flushing cistern & flush pipe including connection to out going pipe and flushing pipe complete all as specified and directed. (Make:Parryware/Hindware/Jaquar/Prayag)
S&F repair plastic water closet seat, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed. (Make:Parryware/Hindware/Jaquar/Prayag)
S&F vitreous china wash basin white flat back size 550 x 400mm with pedestal excluding taps, waste, chain & plug and porcelain stopper but including brackets or fixed to walls with anchor fastners complete all as specified and directed. (Make:Parryware/Hindware/Jaquar/Prayag)
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden/steel frame complete all as specified and directed.
Material, labour (Technician & Helper) and T&P including testing eqpts for carring out comprehensive maintenance and testing of earthing any type as per existing procedure for lighting protection /eqpts/domestic etc in tech area & admin area by tightening of nut bolts arranging earth lead in allighnment manner replacing unservicable earthing lead ,funnel ,pit cover and PCC pits etc (which will be paid as supply only) and testing of earthing and recording result in register (as per procedure provided as directed ,If result found more than permissible limit reconditioning of earthing carried out by pouring water with salt /chemical as per direction and further testing the same earthing result and recording in register incl levelling refilling of earth settle down near pit. Note-(i) Necessary compound required for recharging shall be measured and paid separately under item No 2 here-in-after. (ii) Pouring of salt/chemical/charcoal water in the earth pit is included in the rate quoted.
Supply only charcoal dust powder of superior quality complete all as specified and directed.
Supply only common salt of superior quality complete all as specified and directed.
Supply only carbon based low resistivity compound Bentonite powder solution(advanced earth filling compound) complete all as specified and directed.
Supply and laying in reapir galvanised iron tubing, 40 mm bore,light grade protection of earth strip pipe with all fittings for fixed to pole/wall/ in ground including all fixing accessories including taking out old damaged protection pipe complete all as specified and as directed.
Supply and fix in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25m long hex. head screw including taking out old damaged/ rusted test point terminal block with connecting with earthing strip complete all as specified and directed.
Supply and laying in reapir galvanised iron tubing,15 mm bore, light grade with all fittings for laying of Earth wire or for watering pipe including all fixing accessories and taking out old pipe complete all as specified and directed.
Supply and fix PGI funnel with wire mesh of size 15 mm all including taking out old damaged all as specified and directed.
Material & labour for Chemical earthing complete with copper plate electrode 900mm x 600mm x5mm burried directly in ground vetically to a depth not less than 4.70 mtr below normal ground level (with top edge of earth plate not less than 3.60 mtrs below ground level ) connected to copper strip 32 mm x 6 mm as main earthing lead by means of brass brazing at all joints all as directed and connected to earth test point including galvenizing isolation for equipments to put E-N voltage within limit all as specified and testing on completion with and including necessary excavation and earth work in any type of soil ,GI pipe medium grade 50 mm bore for protection of copper strip from earth electrode to earth test point of galvanised Iron / steel , adequate quality of charcoal dust, common salt and magnesium sulphate in alternate layers of 100 mm thick x 6 layers all around the plate ,including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of red oxide and two coat of painting with synthetic enameled paint of approved quality including writing letters as specified by EIC complete and PCC pit 1:3:6 type C1 using 20 mm bore grade stone aggregrate on PCC base 1:4:8 type using 40 mm agregrate of size 1500x1500x100 mm thick with precast RCC cover 40 mm thick in PCC 1:2:4 type B1 using 20 mm graded stone aggregrate with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle , PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part no 1 of 2009 complete all as spcifed and directed.
M& L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cmx6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I including and connecting to earthing test point block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) PCC base 1:4:8 type using 40 mm agregrate of size 750x750x100 mm thick with precast RCC cover 40 mm thick in PCC 1:2:4 type B1 using 20 mm graded stone aggregrate with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle , PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part no 1 of 2009 complete all as spcifed and directed. including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of red oxide and two coat of painting with synthetic enameled paint of approved quality including writing letters as specified complete including testing on completion complete all as specified and directed.
Ditto all as per item No 57 above here in before but connected to galvanised earth strip 32x6 mm as earthing lead complete all as specified and directed.
Ditto all as per item No 57 above here in before but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead complete all as specified and directed.
M&L for boring underground of 100 mm dia upto 30 mtr depth below ground level in any kind of soil strata for insertion of pipe electrode 30 mtr length and coper strips etc. for bore earthing complete all as specified and directed. ( 1 X 30 RM each)
M& L for lowering bore Galvanised iron tubing, 50mm bore, medium grade with all fittings accessories for protection of earth strips complete all as specified and as directed.( 30 Rm X 01 Nos)
M&L for copper strip 25x3 mm complete with saddles and fixing screws for fitting the strip for earth continuty conductor up to test points. Complete all as specified and directed.
M&L for chemical earthing by drilling a hole of 100 mm dia and 4 mtr in depth in any kind soil and providng a 3.0 mtr long pure copper strip of size 32x6 mm duly encapsulated in a medium grade galvenized steel of pipe of 88 mm OD and filling the hole with advance non toxic earth enhancing back fill compond after not less than 30 kg and water till complete soaking of chemical water mixture and providing a cylindrical type FRP earth pit chamnber of size 254mm dia at top , 330 mm dia at bottom and 260 mm height and 7.5 m long copper strip of size 32 mm x6 mm as earth lead conductor duly protrcted with 65 mm bore medium grade GI pipe from terminal point to earth test point and duly connected with terminal point through breezing and to connect with earth test point with brass bolt nuts and washer of suitable size and fixed on wall by mounting the strip of frp /DMC bridge insulator and providng a test point a terminal block made of gun metal of phosphorus bronze of size 75 mmx75mmx25mm duly drilled and screwed and fixed on wall on insulators including 3 nos 8 mm dia 25 mm long hex haed brass scew complete with removing of excavated soil to a distance not excedding 50 meter and height n. exc. 1.5 m from the starting point and testing on completion all as specified and directed.
Dismantling and taking down worn out and / broken air termination rod and supply and fixing new air termination,single pointed aluminium rod 12mm dia and 300mm long connecting with existing lightening conductor system complete all as specified and directed.
Ditto all as per item No. 64 above but with copper rod complete.
Taking out existing unsv broken/rusted earthing strip of copper,GI and alluminium strip of any size from the existing lighting protection system and to test points complete all as specified and directed.
M&L for copper strip 20 mm x 3 mm complete with saddles and fixing screws for fitting the strip for earth continuty conductor up to test points and up to lighting protection system.
M&L for Alluminium earthing strip of size 25X3 mm including nesassary brazing and connecting existing earthing / lightening conductor system for roof conductors and down conductors above ground level complete all as specified and directed.
M&L for galvanised iron strip 32mm x 6mm with saddles and fixing screws on porcelain insulators for earth continuty conductor up to test points complete all as specified and directed.
M&L for GI earting wire of size 4mm dia galvanised iron or steel wire including nesassary brazing and connecting with existing earthing system complete all as specified and directed.
M&L for laying of single run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 25 Sqmm 1100 volts grade as earth continuity conductor drawn through in rigid non metallic PVC conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc including taking out old unserviceable burnt/damaged wire from its existing position complete all as specified and directed. (Note : Non metallic PVC conduit rate included in the rate quoted ).
M& L for Earthing pit of PCC pit 1:3:6 type C1 using 20 mm bore grade stone aggregrate on PCC base 1:4:8 type using 40 mm agregrate of size 800x800x100 mm thick with precast RCC cover 40 mm thick in PCC 1:2:4 type B1 using 20 mm graded stone aggregrate with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle all incld demolitising old broken pits complete all as specified and directed.
M&L for brazing/soldering to the copper earth strip of size 20x3.15 mm including dismantling from existing position ,equipments without disturbing the functional requirment of the eqipments and reconnecting complete all as specified and directed.
M & L for pit marker/indicator of size 300x200x3 mm with alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of red oxide and two coat of painting with synthetic enameled paint of approved quality including writing letters, in different colors as per directive of VCAS 2016 of Airforce. Complete all as specified and directed.
M&L for painting of pit chamber and cover with syntetic enamelled paint as per code complete all as specified and directed.
Supply & Fixing earthing strip insulator suitable for fixing of earthing strips on walls, roof & floors etc of red colour ceramic material connector type IDC complete all as specified and directed.
Servicing, cleaning of window /split air conditioner (indoor and outdoor unit complete) 1.5/2.0/3.0 Ton capacity at site, cleaning of equipment by applying blower, water pressure Jet machine to remove the complete dust, cleaning of drain line to resolve the issue of leakage all the components with suitable cleaning agent, combing the condenser coil for better efficiancy complete all as specified and directed. Note (i) The servicing / cleaning / repair / maintenance of ACs to be carried out by third party professional service agency like urban clap etc hired by contractor who have not their own workshop (repair centre) of refrigeration and air conditioning. (ii) Contractor has to sign MoU with service provider and details of MoU to be submitted to GE before issue of work order. (iii) At any point of time if performance of service provider is found unsatisfactory in opinion of GE, the contractor shall cancel the MoU with service provider immediately and fresh MoU with different service provider to place within 10 days otherwise recovery shall be made @ Rs 550 per day of delay.
Repair/ maintenance of window /split type air conditioner 1.5/2.0/3.0 Ton capacity at site,checking the wiring, starting/running capacitor, staring relay, overload relay, thermostat switches condensor motor,blower motor,swing motor ,blower/condensor fan/ removal of defactive parts and rectification of fault,Top Up/charging of gas at required pressure for proper cooling, connecting and testing on load.all as specified and directed. NOTE;- (i) Defective parts/Gas (refrigerant) shall be measured and paid seperately as 'Supply Only' under respective item of Sch "A" (ii) Complaints have to attend on day to day basis and regular visit of adequate mechanic during contract period to maintain above Nos appliances at the Stn in tech and as well as Adam area. (iii) Payment for each job shall be made once only during currency of contract irrespective of attending / replacing defective parts at any time that will be paid supply only under respective item if not paid earlier. (iv) complaint for non function of ACs have to attend on same day and normal defects have to rectify within 24 hours ,major defects have to rectified within 4 days otherwise recovery shall be made @ 500/ day of delay. (v) If required and repair is beyond at site taking out & refixing of AC / any repair shall be deemed to include in quoted rate. (vi) The servicing / cleaning / repair / maintenance of ACs to be carried out by third party professional service agency like urban clap etc hired by contractor who have not their own workshop (repair centre) of refrigeration and air conditioning. (vii) Contractor has to sign MoU with service provider and details of MoU to be submitted to GE before issue of work order. (viii) At any point of time if performance of service provider is found unsatisfactory in opinion of GE, the contractor shall cancel the MoU with service provider immediately and fresh MoU with different service provider to place within 10 days otherwise recovery shall be made @ Rs 550 per day of delay.
Supply only R-22/R-32/R- 410 or required refrigerant in the Air conditioner to be repaired in Sch-A item No.2 of testing to the cooling appliances complete all as specified and directed.
Supply only condenser/Cooling fan motor along with fan blade suitable for window type AC of existing make.complete all as specified and directed.
Supply only condenser fan motor suitable for spit AC of 1.5/2.0 TR capacity AC of existing make.complete all as specified and directed.
Supply only condenser fan blade suitable for spit AC of 1.5/2.0 TR capacity AC complete all as specified and directed.
Supply only of indoor blower fan motor suitable for split type AC of 1.5/2.0 TR capacity of existing make with supper enameled copper winding fixing and testing on load all as specified and directed.
Supply only of indoor blower fan Assembly suitable for split type AC of 1.5/2.0 TR capacity & make of existing make complete all as specified and as directed.
Supply only of indoor evaporative coil assembly suitable for split type AC of 1.5/2.0 TR capacity & make of existing make all complete all as specified and as directed.
Supply only running capacitor 36-60 MFD complete all as specified and as directed.
supply only condenser fan motor capacitor of capacity 4.0 mfd / 6.0 mfd suitable for existing window type/ outdoor unit of split type air conditioner of capacity upto 2.0 TR complete all as specified and as directed. Make:Sarda/Unistar/Tibcon/Asian/Epcos.
supply only New Remote and PCB sensor unit assembly suitable for existing make of window / split type air conditioners non inverter model of capacity upto 2.0 TR complete all as specified and directed.
Supply only Indoor circuit board PCB of inverter type Split AC of Make : Daikin/LG/Voltas/Blue star as existing at site of capacity 1.5/2.0 TR Split type A/C and complete all as specified and directed.
Supply only outdoor circuit board PCB of inverter type Split AC of Make : Daikin/LG/Voltas/Blue star as existing at site of capacity 1.5/2.0 TR Split type A/C and complete all as specified and directed.
Supply only single phase contactor 240 volt, 25 Amp for split type AC 1.5/2.0 TR complete all as specified and directed.
Dismantling / taking out unserviceable burnt sealed compressor unit 1.5/2.0 TR from air conditioner and fixing only hermetically sealed rotary type compressor unit of any capacity including necessary brazing the same with existing refrigerant pipe, supply and charging refrigerant gas including testing all as specified and directed by engineer incharge Note: (i) Hermetically Sealed compressor shall be measured and paid separately under supply only.(ii) Suitable refrigerant shall be measured and paid seperately as 'Supply Only' under respective item of Sch "A"
Supply only hermetically sealed rotary type compressor unit of capacity 1.5 TR complete all as specified and directed.
Supply only hermetically sealed rotary type compressor unit of capacity 2.0 TR complete all as specified and directed.
Repair/Maintanence of Cuircuit board PCB suitable for existing make of window / split type air conditioners non inverter model of capacity upto 2.0 TR complete all as specified and directed.
Taking down unserviceable condensing coil unit and supply and fix new copper condensing coil unit suitable for window AC of capacity of 1.5 TR, as per the existing, including brazing the suction / discharge lines and filling the suitable refrigerant gas and testing on complete all as specified and as directed. Note : Refrigerant shall be measured and paid seperately as 'Supply Only' under respective item of Sch "A"
Taking down unserviceable condensing coil unit and supply and fix new copper condensing coil unit suitable for split type AC of capacity of 1.5 TR, as per the existing, including brazing the suction / discharge lines and filling the suitable refrigerant gas and testing on complete all as specified and as directed. Note : Refrigerant shall be measured and paid seperately as 'Supply Only' under respective item of Sch "A"
Taking down unserviceable condensing coil unit and supply and fix new copper condensing coil unit suitable for window / split type AC of capacity of 2.0TR, as per the existing, including brazing the suction / discharge lines and filling the suitable refrigerant gas and testing on all as specified and directed. Note : Refrigerant shall be measured and paid seperately as 'Supply Only' under respective item of Sch "A"
M&L for replacement of copper tube/thermal Insulating tube of suction and discharge line of existing size and diameter from indoor unit to outdoor unit by pumping back the refrigerant to outdoor unit. Note:- (i) Any gas leakage during changing of copper tube/thermalinsulating tube will be bear by contractor itself. (ii) copper tube shall be measured and paid seperately as 'Supply Only' under respective item of Sch "A"
Supply only copper tube 1/2'' as per site requirement complete all as specified and as directed.
Supply only copper tube 1/4'' as per site requirement complete all as specified and as directed.
Supply only thermal insulating tube as per site requirement complete all as specified and as directed.
M&L for detecting leakage of refrigerant from Split/ Window AC by leakage test with provision of all T&P items as required at site and charging the refrigerant gas (R-22/ 32/ 134(a)/ 410C) as required,making good leakage portion by brazing complete all as specified and directed. Note : The cost of Refrigerant is deemed to be included in quated rate.
Ditto all As per item No. 103 here in before but for water cooler
Ditto all As per item No.103 here in before but for refrigerator/Deep fridger.
Pumping down the AC, taking carefully the indoor and outdoor units along with voltage stablizer of split type air conditioner of capacity upto 2.0 TR by disconnecting all electrical connections, suction and discharge lines from its installed position and shifting to another location where directed and installing the indoor and outdoor units alongwith stablizer at specified location and connecting all the electrical, suction and discharge lines, topping up the gas as required and testing on completion for proper functioning complete all as specified and directed.
Taking out old U/S voltage stabilizers of capacity 1 KVA to 5 KVA from MES store/site and repair the same in MES work shop (if the transformer found burnt, the same shall be re-winded in the workshop of contractor as directed)
Material and labour for re-winding of transformer of voltage stabiliser of capacity 1 KVA to 5 KVA
S&F main relay 24 volts 25 Amps etc complete all as specified and directed.
S&F main control circuit (PCB) etc complete all as specified and as directed.
Supply & Fix in repair wall mounted digital display voltage stabilizer copper winding, for automatic voltage correction single phase, naturally air cooled, indoor type, designed for input voltage between 170 Volt to 280 Volts and out put voltage 230Volt and High / low voltage cut off with facility of including instant start & time delay relay of 3 minute capacity 5 KVA. Complete all as specified and directed.
Ditto all as per item No. 111 above here in before but 4 KVA
Taking out old unserviceable burnt sealed compressor from refrigerator/Deep freezer and fixing only new hermetically sealed compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing all as specified and directed. Note: (i) Hermetically sealed compressor shall be measured and paid separately under supply only item. (ii) The cost of Refrigerant gas is deemded to be included in quoted rate.
Supply only hermetically sealed compressor suitable for refrigerator/Deep freezer of capacity upto 310 Ltrs.
S&F in replacement inverter model PCB suitable for refrigerator/Deep freezer upto 310 Ltr capacity complete all as specified and as directed.
S&F in replacement of evaporative coil unit suitable for refrigerator/Deep freezer upto 310 Ltr capacity complete all as specified and as directed.
S&F in replacement of relay suitable for refrigerator/Deep freezer upto 310 Ltr capacity complete all as specified and as directed. (Make: Indfos/Godrej/Whirlpool or equivalent)
S&F in replacement of over load protector suitable for refrigerator/Deep freezer upto 310 ltr capacity complete all as specified and as directed. ( Make: Indfos/Godrej or equivalent.)
S&F in replacement of thermostat suitable for refrigerator/Deep freezer upto 310 Ltr capacity (Make: Indfos/Godrej/Whirl Pool or equivalent )
S & F in replacement of Magnetic rubber door gasket suitable for refrigerator of any make & capacity complete all as specified and as directed.
Disconnect and remove unserviceable copper cable of any description and supply and connect new PVC insulated and PVC round sheathed 3 core, 1.5 Sqmm Copper conductor cable, heavy duty, 1100 Volts grade complete all as specified and as directed.
Ditto all as per Ser item No.121 here-in-before but of size 3 core, 2.5 Sqmm complete all as specified and directed.
S&F in replacement of fan motor suitable for deep freezer of any make and capacity complete inlcuding taking down existing unserviceable motor complete all as specified and as directed..
Dismantling / taking out unserviceable burnt sealed unit of compressor from water coolers any make and capacity and fixing only hermetically sealed compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply and charging refrigerant gas including testing complete all as specified and as directed. Note: (i) Hermetically Sealed compressor shall be measured and paid separately under supply only.
Supply only new sealed unit compressor suitable for water cooler 40/80 Ltr
Supply only new sealed unit compressor suitable for water cooler 60/120 Ltr
Taking down unserviceable condensing coil unit and supply and fix new condensing coil unit suitable for water cooler of capacity upto 310 Ltrs,as per existing model,including brazing the suction /discharge line and filling the suitable refrigerant gas.complete complete all as specified and as directed. Note : The cost of refrigerant is deemed to be included in quoted rate.
Taking out water cooler of any make and capacity from position and cleaning the complete condenser coil & storage tank with chemical base solution and soda water including servicing, oiling, of FHP motor checking of electrical & water supply connection and re-fixing the same on its original position and testing complete all as specified and as directed.
S&F in replacement of starting capacitor 80-100 MFD complete all as specified and as directed.
S&F in replacement of Relay & OLP suitable for water cooler of any make & capacity complete all as specified and directed.
S&F in replacement of thermostat switch suitable for water cooler complete all as specified and directed.
S&F in repair Push taps suitable for water cooler capacity up to 150 ltr etc complete all as specified and directed.
S&F PVC flexible pipe heavy duty transparent 15mm/20mm dia (as per sample) etc complete all as specified and directed.
S&F in repair ball valve 15mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe etc complete all as specified and directed. (Weight min 142gms)
Dismantling / taking out un-serviceable burnt FHP motor from water cooler and supply & fixing new FHP motor with suitable fan blade single phase 1/8 to 1/35 HP suitable for up to 150 Ltr capacity water coolers including testing all as specified and directed.
S&F in replacement of running capacitor 4 MFD 230 volts 50 Hzs AC suitable for water cooler and desert cooler including taking out old capacitor complete all as specified and directed.
M&L for painting of desert cooler external body, fan with one coat of synthetic enameled gray paint & internal body with synthetic enameled black paint complete with brush painting after proper dusting, cleaning and scrapping old painted surfaces complete all as specified and as directed.
S&F in replacement of wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with Gi wire for desert cooler of any make complete all as specified and directed.
M&L for rewinding of stator of exhaust fan/kit fan 18" sweep 900 RPM of any make with super quality of winding copper wire of existing size complete with varnishing, backing, testing including painting with synthetic enameled paint of grey colour complete all as specified and as directed.
Supply and fixing in replacement of submersible water lifting pump of capacity 1.25 m head, 230 Volts complete all as specified and directed.
S&F in replacement of Kit fan motor 450 mm sweep 1350/1400 RPM complete all as specified and directed. ( Make: Everest/Summer Cool/Khaitan )
Taking down old and unserviceable sub main wiring any size / type/ core including earth wire complete with batten /conduit etc and making good the disturbed surface to match the existing disturbed surface complete all as specified and as directed.
S&F of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4 sqmm complete drawn in PVC concealed rigid non-metallic conduit medium grade along with 1x 4 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type for continuous earth wire and connected to common earth dolly complete all as specified and as directed. Note - (i) Cutting chases for concealed conduit and making good in cement mortar is deemed included in unit rate. (ii) 2 runs of 4 sqmm wire and 01 run of earth wire to be measured as one run.
S & F in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.
Supply and fix 2 AC controller timer with tempreture based fully advanced LCD digital timer heavy duty,relay output,time can be set I Hr to 12 Hrs as well you can set tempreture based wall mounted with isolated rugged power supply,ISO 9001,CE certified and MSME Regd Co complete all as specified and directed.
M/s R K Associates (BID ID -3464559)
H C CONSTRUCTION (BID ID -3454842)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_820855.xls
BOQ • 0.57 MB
8814tenderdocuments.pdf
Tender Documents • 1.40 MB
8814credit.pdf
Additional Documents • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .