Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.7 LAccepted-AOC 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹92.1 L+₹13.4 L (17.0%)Rejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance HIGHEST | |
| 3 | L3₹95.8 L+₹17.1 L (21.7%)Rejected-Finance | L3 | Rejected-Finance HIGHEST | |
| 4 | L4₹1.2 Cr+₹37.4 L (47.6%)Rejected-Finance | L4 | Rejected-Finance HIGHEST | |
| 5 | Rejected-Technical VILL CHHOTO CHAND GHAR PO BARA CHAND GHAR DIST NADIA PIN 741196 | 741196 | - | Rejected-Technical Insufficient documents found as per NIT criteria |
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
28 Jan 2021, 2:00 pmClosed
Superintending Engineer PWD Electrical
Superintending Engineer PWD North Bengal Electrical Circle P.W.D Inspection Bungalow Annex Building 1ST Floor Kutchery Road Venus More Siliguri
Construction of CMOH Office Complex of Alipurduar District Hospital Alipurduar External E.I. Works i.e. S.I.T.C of Sub station Fittings and Fixtures Panel and Cable works L.C Installation and Compound Illumination
2021_WBPWD_313922_1
WBPWD/SENBEC/NIT-50/2020-2021
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
CMOH Office Complex of Alipurduar Dist. Hospital
Please refer Tender documents.
6 documents required · 6 mandatory
₹1.8 L
10 Mar 2021
8 Jan 2021
1 Feb 2021
8 Jan 2021
28 Jan 2021
15 Jan 2021
Amount
SUB HEAD : DISTRIBUTION WIRING
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish (Average run 8 mtr)
Supply and drawing of 1.1KV single core stranded FRLS PVC insulated & unsheathed single core copper wire in PVC Rigid conduit FR grade incl. necessary fittings as required. 3 x 1.5 sqmm in 20mmbore PVC conduit
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
SUB HEAD : PLUG & SOCKETS
Supply & Fixing 240 V, 25 A, Modular type starter (Brandapproved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
SUB HEAD : FAN & FAN CLAMPS
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supply & delivery of 250 volt. 56" (1400 mm) sweep A.C. Ceiling fan having safety wire , P2 type capacitor incl. down rod, canopy & fan blades etc. complete with all accessories (without regulator) & having Minimum Air Delivery 265 CMM, Double Ball Bearing & Low Noise. [Make - As per Approved Make List]
Supply & delivery of 250 volt. 48" (1200 mm) sweep A.C. Ceiling fan having safety wire , P2 type capacitor incl. down rod, canopy & fan blades etc. complete with all accessories (without regulator) & having Minimum Air Delivery 220 CMM, Double Ball Bearing & Low Noise. [Make - As per Approved Make List]
Supply & delivery 250 volt. 16" metal body & Blade wall Bracket Fan complete with all accessories.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supply of Exhaust fans size 12"( 300mm ) Speed 920 RPM complete with all accessories.
S&D of 240V Single industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 1xT-LED22W P3241/ Equivalent product of Crompton/Wipro having similar specification in all respect). incl S&D 1x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I 2100 Lumen PC Body/ Equivalent product of Crompton/Wipro having similar specification in all respect)
S&D of 240V Twin industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 2xT-LED22W P3241/ Equivalent product of Crompton/Wipro having similar specification in all respect). incl S&D 2x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I 2100 Lumen PC Body/ Equivalent product of Crompton/Wipro having similar specification in all respect)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type 125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with U type MS clamp and suitable size MS fastener, Nut-bolt, Ceiling plate, nipples etc. as required
Supply & Fixing of decorative Light suitable for Mirror Light (Make/Model- Make as per approved make list & Model as per direction of the EIC)
Supply & Fixing 240 V 9 Watt LED Bulb . (Make - Philips / Crompton / Wipro)
Supply & Fixing recessed mounted LED downlight Luminaires after making housing in false ceiling by Co's own tools& Tackles. (Make / Model - Philips DN092B LED10S-3000 / 4000 / 6500 PSU WH / or equavalent product of Crompton / Wipro having similar specification)
Supply & Fixing recessed mounted LED 2'x 2' Luminaires with UGR <19 after making housing in false ceiling by Co's own tools& Tackles. (Make/Model - Philips RC380B LED36S -4000/6500 G4 L60 W60 PSU OD OC / or equavalent product of Crompton/Wipro having similar specification)
SUB HEAD : LIGHTNING CONDUCTOR
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work
Making soldered joints between conductor/ conductor & air terminals by 7/10 stranded GI (Hot Dip) wire incl. supply of jointing materials & painting with 2 (two) coats of Bituminous paint
Making soldered joints between conductor/ down pipes / other metallic objects by 7/10 stranded GI (Hot Dip) wire incl. supply of jointing materials & painting with 2 (two) coats of Bituminous paint
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Supply and laying of G.I. tape / strip 32 mm X 6 mm from earth electrode directly in ground as required.
SUB HEAD : COMPOUND ILLUMINATION
Supply & Delivery of Hot Dip Galvanised (as per IS:2629 / IS 2633 / IS 4759 and with its latest amendment ) Octagonal Pole made of HT steel ( sheet thickness -3mm ) conforming to grade S355 of BSEN 10025 alongwith welded base plate of required size conforming to IS: 226 / 2062 with integrated Control box with required sizes studs for termination of 2 core 10 /4 Core 16 sq mm Al (Armoured ) cable incld S&F 1 No 6 Amp SP MCB ( C-Series ) for each out going circuit to the fittings with proper pad locking arrangement for the following pole -- (Make : Bajaj / Philips / Valmont / CG / Transrail / Bansal / Utkarsh ).
(i) 7 Mtr Long [ Top Dia ( A / F ) - 70 mm, Bottom Dia ( A / F ) -130 mm] Base Plate Size : 220 mm x 220mm x 12 mm..
Errection of the following Octagonal pole by designing and Casting RCC ( M 20 ) foundation of suitable size as specified below considering the safe soil bearing capacity at site as T/sq m, including excavation of earth, providing, cutting, bending and placing in position reinforcement as per drawing and providing pipe for cable entry and exit as required and providing and fixing of 4 Nos foundation bolts ( J Type ) as specified below and as per drawing on ground surface including back filling and cleaning extra earth.
(i) 7 Mtr Long [ Founation size - 500 mm X 500 mm X 1400 mm, J Bolt Size - Dia 20mm Length 700mm ]
SITC of single dip galvanized steel overhang bracket ( Swan Neck Type ) at the top of the pole having 1 M length complete with all fixing arrangements as required including painting
Single Arm
Double Arm
SITC of road lighting luminaire ( IP 65 ) with peanut lens and high power LED and to ensure uniform distribution, higher spacing between poles and maintenance free system and system lumen output will be minimum 110 lumen/w suitable for use with 230Volt 50Hz AC supply etc as required.
(i) Philips Model No. BRP410 LED CW 072 MR FG S1 PSU GR / or equavalent product of Crompton / Wipro having similar specification)
SITC of Post top Gate lighting luminaire ( IP 65 ) and resistant to impact and corrosion, Glare-free and better uniformity with peanut lens and high power LED [Make - Crompton Greaves, Model - LPTO-40 WW/M / or equavalent product of Philips / Wipro having similar specification]
Supply & Delivery of 1.1 KV grade XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, and conforming to IS: 7098(Part-I):1988/1554(Part-I):1988/ 5831:1984/ 3961(Part-I):1967/ 3975:1970/ 10810:1984 / 3975:1970 /8130:1984/ 3961:1967/ 10418:1982 / 10810:1984 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith.
2 Core 10 Sq.mm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of two cables upto 35 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
2 Core 10 Sq.mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
2 Core 10 Sq.mm
Connection from loop box to fittings by S&L of following 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire through 13 mm dia polythene pipe (As per approved make list). 3 x 1.5 sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
32 mm dia
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Supply and laying of G.I. tape / strip 32 mm X 6 mm from earth electrode directly in ground as required.
SUB-HEAD - SUB STATION WORK
SITC OF 11 KV VCB PANEL & 11/0.415 KV TRANSFORMERS & MAIN PANEL
Supply & Delivery of Cast Resin Dry Type 11KV/415V 250 KVA, 3 Phase,50Hz, Dyn11,copper wound, Class F insulation associated with winding temperature indicator/controller,having cable end box in the HV & LV sides suitable for 3 Crore 240 Sq. mm. XLPE cable of 11 kV grade on HT side and 2 nos 4 Core 185 sq. mm in LV side and all accessories and conforming to IS 11171-1985 & IS - 2026 with latest modification (if any) & CBIP Specification and as per detail specification attached ( uploaded in the specification section) [ Make: ABB / Voltamp (Vadodara) / CGL ].
Installation & commissioning of 11KV/415V 250 KVA distribution transformer incl. carriage to the substation building within a lead of 30mtr by placing in position and fixing after leveling fitting all components, connecting, checking & set of all instrument, relays according to requirement as instructed by the EIC incl. S&F base channels etc.
Supply & Delivery Indoor-type, floor mounted,metal clad, single tier, fully compartmentalized,free standing, 11 kV VCB Panel with 1 Nos 630A VCBs , totally enclosed and fully interlocked , horizontal drawout, horizontal / vertical isolation type breaker as per IS 13188, as ammended upto date and as per detail specification attached ( uploaded in the specification section) , suitable for use on 11 KV, 3 Phase,50 Hz AC supply to energise 1 X 250 KVA Dry Type Transformers. [ Make : ABB / Siemens / CGL].
Installation & commissioning of the above 11 kV VCB Panel with P.T & all the accessories, incl. carriage, by placing in position, assembling, lining up, levelling and checking all instruments, relays, correctly set according to requirement.
Making testing arrangement and submitting the test report for high voltage testing of specified voltage incl. checking & testing of all HT / LT equipments by authorized firm of Directorate of Electricity & commissioning the installation after obtaining the Approval of Directorate of Electricity.The scope shall be also included the necessary approval from Authority also.
Supply & fixing 75x45 mm "C" channel having length of 2 mtr. each channel incl. nuts, bolts and washer etc.
SITC of floor mounted Indoor type extensible cubical MV switchboard,fabricated by CPRI approved panel maker having compartmentalized design, fabricated out of 14 SWG ( 2.0 mm ) nominal thickness CRCA sheet steel,front and back openable, hinged, single shuttered, with incoming ACBs & Outgoing MCBS and all accessories as per size, design & drawing to be approved by EIC and conforming to IS with latest modification and as per detail specification attached ( uploaded in the specification section) [LT MAIN PANEL IN THE SUBSTATION - I/C - 400A 50KA MCCB-1No, O/G-250A 50KA MCCB - 2 nos, 160A 36KA MCCB - 1 nos, 100A 36KA MCCB-1No, 40A 36KA MCCB - 2 nos]
SUB HEAD II - HT/ LT CABLING IN SUBSTATION
Supplying of 11KV (UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable conforming to IS 7098, of earthed system of following size.[ From Supplier HT Gear to Consumer HT Gear and to Transformer]. [ Make : Nicco / Gloster / Polycab / Havells / RR Kable / Crystal ]
3 Core x 240 Sq.mm
Making heatshrinkable joints to the ends of the following XLPE HT cable at the transformer end as well as at the VCB ends supplying with necy. jointing kits, sockets, sleeves, anti-corrossive paste, wires, solders, jointing compounds, rubber sheets etc. incl. supplying of necy. tools & tackeles for crimping the end sockets, soldering irons & making of glands at the both end of the cable as per directions of EIC
3 Core x 240 Sq.mm
Laying of 1 No. 11KV (UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable confirming to IS 7098, of earthed system of following size in the existing Masonary Open Duct as required.
3 Core x 240 Sq.mm 11KV XLPE HT cable
Supply & Delivery of 1.1 KV grade XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, and conforming to IS: 7098(Part-I):1988/1554(Part-I):1988/ 5831:1984/ 3961(Part-I):1967/ 3975:1970/ 10810:1984 / 3975:1970 /8130:1984/ 3961:1967/ 10418:1982 / 10810:1984 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith.
4Core 185 Sq. mm [ Transformer to Main Panel]
Laying of 1.1KV Grade XLPE Aluminium conductor, PVC sheathed, armoured cable of following size in the existing Masonary Open Duct as required.
4Core 185 Sq. mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below including finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
a) 4Core 185 Sq. mm
Supply & Drawing 1.1 KV Grade 7 Core 1.5 sq.mm PVC Armoured Copper Cable from Transformer WT relay to VCB WT relay for Power & Control Supply as per direction of EIC
SUB HEAD III - EARTHING
S& laying 120 sq. mm. single core multistrand PVC insulated flexible Cu wire in suitable size of PVC flexible pipe (reinforced) from nutral earth busbar to transformer point as required (for Transformer /Generator neutral earthing) including Socketing both sides by Cu Socket.
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S.
Supply & fixing earth busbar of galvanized (Hot dip) MS flat 65 mm x 8 mm on wall having clearence of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Insulating the 65 x 8 mm M.S. flat incl. S&F black heat shrink PVC sleeves etc. The PVC tube sleeve to be inserted on the GI flat and heat shrinked by heating apparatus by skilled technician carefully without damaging the PVC sleeve as per direction of the EIC
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
S & F special type armour clamp for earthing attachment to wiping gland of HT cable termination
SUB HEAD - IV ( SAFETY EQUIPMENT )
Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscription in signal red colour on front side as required.
a) High Voltage - size 250mm x 200mm
b) Medium Voltage - size 200mm x 150mm
Providing and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS 15222-2002 and cylinders fully charged of following capacity(4.5 Kg ) [Make - Fire Shield / Ceasefire]
Supply and fixing of foam fire extinguishers conforming to IS 4989-2006, Portable type 9 lit capacity hanged on wall with bracket complete as required. [Make - Fire Shield / Ceasefire]
Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required (approx. Front area 1.20 sq.mt.)
Providing of set of 4 nos. 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint 'FIRE' and mounted on MS angle iron frame with bracket and suitable base of appropriate size & capacity I/c filling sand etc.
Providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 13115-1991.
Supply and fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as reqd. (approximate front area 1.20 sq.metre).
Providing of rubber mat 2 mtrs Length x 1 m. wide and 12mm thick to withstand 15 KV dielectric strength as per IS 15652-2006.
Providing of rubber mat 2 mtrs Length x 1 m. wide and 6mm thick to with stand 3.3 KV dielectric strength as per IS 15652-2006.
S&F 11kv grade Rubber Hand Gloves.
SUB HEAD - LT CABLING IN BUILDING
Supply & Delivery of 1.1 KV grade XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, and conforming to IS: 7098(Part-I):1988/1554(Part-I):1988/ 5831:1984/ 3961(Part-I):1967/ 3975:1970/ 10810:1984 / 3975:1970 /8130:1984/ 3961:1967/ 10418:1982 / 10810:1984 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith.
4 Core 185 Sq.mm [ SUBSTATION TO BUILDING ]
4 Core 95 Sq.mm [ Main VTPN TO Power VTPN]
4 Core 70 Sq.mm [ Main VTPN to VTPN having upto 160A I/C ]
4 Core 50 Sq.mm [ VTPN TO LIFT PANEL ]
4 Core 25 Sq.mm [ MAIN LT PANEL TO SUBSTATION TPNDB, STREET LIGHT FEEDER PILLAR BOX ]
Laying through Floor / Pavement / Wall
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor / pavement / wall etc.
Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor / pavement / wall etc.
Above 95 sqmm at an average depth of 100 mm in floor / pavement / wall etc.
Laying on Wall / surface with Saddles / clamps
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on all/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying through Underground Trech
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of two cables upto 35 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
Laying through Wire Tray
Supply & fixing Electro Zinc Galvanised Wiremesh cable Tray in accordance with standard BSEN12329-2000 with allmounting accessories. All trays should be 3000 mm long. Cable tray shall be manufactured from steel wires, welded together and ben into final shape prior to surface treatment. Steel Wire CableTray should be produced from lateral and longitud in al side wall steel wires, with minimum diameters between 3.9mm to5.9 mm for trays depending on the width s of the trays as per the design paramete. (Make: LEGRAND - CABLOFIL / LEVITON / COPE)
Size of tray (width 150 mm x depth 54 mm)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 Core 25 Sq.mm
4 Core 50 Sq.mm
4 Core 70 Sq.mm
4 Core 95 Sq.mm
4 Core 185 Sq.mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
4 Core 25 Sq.mm
4 Core 50 Sq.mm
4 Core 70 Sq.mm
4 Core 95 Sq.mm
4 Core 185 Sq.mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
50 mm dia
65 mm dia
80 mm dia
SUB HEAD - SITC OF MAIN VTPN IN THE BUILDING
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
INCOMING & OUTGOING SECTION
(i) Supplying and fixing 415 volts, 4 Pole MCCB [50 kA (Ics)] breaking capacity, with microprocessor release and rotary operating handle in existing DBs / enclosure and necessary connection -250A [Incomming]
OUTGOING SECTION
(ii) Supplying and fixing 415 volts, 4 Pole MCCB [50 kA (Ics)] breaking capacity, with microprocessor release and rotary operating handle in existing DBs / enclosure and necessary connection -200A-6 nos
(iii) Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection -125A-2 nos
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [for LIFT Supply] 4 Way, I/C 4 pole 63A Isolator, O/G - 12 nos 6-32A SP MCB
Supply & Installation of Glow Sign Board
LED Signage: Designing, Fabrication, Supply, Installation, Testing & Commissioning of Outdoor LED Signage (Approximate Size:16' Length X 6' height) in English (letters given and approved by concerned department) for letters with following specifications
(a) The box for the signage will be fabricated in Aluminum Square tube of size 25 mm. X 25 mm. of 16 gauge complete with necessary priming and painting. The front of the box will be covered with 3 mm. thick Aluminium Composite Panel (ACP) sheets of the entire board. The board to be fixed in front of canopy by providing required support and Angle Bracing. The complete installation will be water, vermin and dust insulated and protected.
(b) Letter Description: Approx 9" x 5" size of letters made of Aclrylic Sheet with male female attachment, on router cut ACP Sheet of front incl. all accessories as required.
(c) LED Illumination:High Bright, High Wave length closed type waterproof white LED modules (0.72 W or Higher) mounted on interior side of female part of letter with power wire running back to a central power area with 12 Volt LED Power Transformer to adequately drive the whole LED modules without Flicker.
(d) Internal Electrical Wiring will be done by Halogen Free Flame Retardent HRFR compound insulated (Unsheathed) 1.5 Sq.mm. copper flexible cable through interior conduit and Electrical Raceway.
Erection the above sign board with three nos. 40x40x6mm MS angle iron bracket the support on the back side rigidly grouted on suitable muffing which are making on the roof to avoid the uprooting by wind pressure and painting as per direction of EIC
Terms and condition
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
ORIENT ENGINEERING WORKS
BISPA INDIA
M/S PRAKASH ENTERPRISE.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .