Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC VILL KISHANPURA P O JAMNIWALA TEHSIL PAONTA SAHIB DISTRICT SIRMOUR HP | PAONTA SAHIB | SIRMOUR | HIMACHAL PRADESH | L1 | Accepted-AOC AOC | |
| 2 | L2₹13.9 L+₹13,576 (0.99%)Rejected-Finance | L2 | Rejected-Finance Second lowest bidder | |
| 3 | L3₹15.0 L+₹1.2 L (9.00%)Rejected-Finance GROUND FLOOR THAKUR COMPLEX BASANTPUR | BASANTPUR | SHIMLA | HIMACHAL PRADESH | 171018 | L3 | Rejected-Finance Third lowest bidder | |
| 4 | L4₹15.1 L+₹1.4 L (9.98%)Rejected-Finance | L4 | Rejected-Finance Fourth lowest bidder | |
| 5 | L5₹17.6 L+₹3.8 L (27.8%)Rejected-Finance 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | L5 | Rejected-Finance Fifth lowest bidder |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
16 Aug 2019, 5:00 pmClosed
Executive Engineer
HPSIDC Ltd. Shimla
Providing Electrical installation in Sainik Rest House Solan, Distt. Solan (HP).
2019_SIDC_30552_1
Job No. 20
Open Tender
Electrical Works
Item Rate
90 days
Solan
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,700
EE HPSIDC Ltd. Shimla
₹30,000
2 Aug 2021
30 Jul 2019
17 Aug 2019
30 Jul 2019
16 Aug 2019
30 Jul 2019
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group C.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. (i) 2x10 Sq. mm.
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- (i) 25 mm. dia.
Supplying and drawing co-axial TV cable,RG-6 grade,0.7mm (75 Ohms) copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. (i) S.P. 5/ 6 Amps one way Modular switch.
(ii) 5 pin, 5/ 6 Amps Modular socket outlet.
(iii)TV. Socket outlet, modular.
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:-(i) 2 modules (78mmx78mmx50mm)
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
Supplying and fixing bakelite batten/angle holder including connections etc. as required.
(ii) 450 mm deep (nominal)
Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx4.75mm),in the existing enclosure with all accessories including connections etc. as required.
Supplying and fixing copper strip bus-bars suitable for 400 Amp. 415 volts capacity 4 No. each of cross-sectional area (38.10mmx6.35mm),in the existing enclosure with all accessories including connections etc. as required.
Providing and fixing following rating, four pole, 415 volts, On-Load change over switch unit, panel mounting, front handle operation, including drilling holes in the cubical, making connections, etc. as required.(i) 200 Amps.
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required. (i) 100 Amp. -16 KA
(ii) 315/400 Amp. -35 KA
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(i) Double pole. Cat-A.
(ii) Triple pole & Neutral. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (i) 63 Amps. Cat-A.
Supplying and fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (i) 63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Double door-12 way
Supplying and fixing of following way triple pole and neutral, sheet steel MCB distribution board, 415 volts, on surface / recess, with provision for 4-pole MCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-(i) Single door-6 way (8+18), horizontal type.
(ii) Double door-12 way (8+36),horizontal type
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for pipe earth electrode complete as required.
Providing and fixing 6 SWG (4 mm dia.) G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:-(i) Armoured cable 6 sq. mm (twin core)
(ii)Armoured cable 150 sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-(i) Armoured cable 6 sq. mm (twin core)
(ii) Armoured cable 150 sq. mm (3.5 core)
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:- (i) 25 Liter capacity water heater (Cat-A)
(ii) 35 Liter capacity water heater (Cat-A)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- (i) Ceiling Fan 1200 mm sweep, Category-A
(ii) Ceiling Fan 1400 mm sweep, Category-A
(ii) Ceiling Fan 1200 mm sweep Fusion Metallic Beige Brown /Pearl Ivory-Gold Havells
(iii) Ceiling Fan 1400 mm sweep Fusion Metallic Beige Brown /Pearl Ivory-Gold Havells
Providing and installation of exhaust fan/vent air fan ha/Bajaj/Havells / Krompton of Usof following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- (i) Exhaust Fan, Light duty,(Domestic) 300 mm sweep
(ii) Exhaust Fan, Heavy duty, 300 mm sweep
Supplying and fixing of bulk head fitting of all sizes and shapes, containing one No. thread type CFL lamp holder (s), complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. Bulk head fitting, CFL type (Category-A)
Supplying and erection of 2 stepped aluminium CLASSIC tubular pole of suitable length. The pole made out of extruded aluminium profiles having dia. 150 mm at bottom and 90 mm on top. The 90 mm & 150 mm profiles to be joined together with a die cast aluminium coupling duly riveted/bolted together. The pole provided with a service window at bottom profile containing bus-bar, cut-outs, cable glands etc. The pole to be mounted on a 1:2:4 cement concrete base (pedestal) of 220 mm dia and 375 mm foundation bolt depth in a hole of excavation about 300 mm dia. and of suitable depth, to be filled with 1:3:6 cement concrete up to a height of 450 mm from bottom and then fitted with M.S. bolts / nuts of 12.5 mm dia; 375 mm length. complete in all respects as required:- (a) Overall length 3 meter, with planting bolt depth 375 mm/12.5 mm dia, length and outer dia of sections 700 mmx150 mm and 2300 mmx90 mm (bottom and top respectively).
Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (s) of all sizes and shapes, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required and as approved by engineer in charge. (i) Fixed type wall bracket Havells/ Bajaj/Decon single lamp.(Category-A)
(ii) Mirror light 610 mm, double lamp.(Category-A)
Providing & fixing LED Batten integrated LED channel of Bajaj make having Bajaj/ Havells / Philips make as below:(i) Batten/LED integrated channel fitting 10W
(ii) Batten/LED integrated channel fitting 20W
Providing & fixing surface/ recess mounted 12/ 15W LED fitting of Syska/Havells/Philips/ Bajaj make as required complete in all respect.
Supplying & fixing SKYLUKS LED surface mounting fitting 1'*1' LED luminaire of Bajaj/Havells/Philips or its equiavent make as per CAT No. BZSSQL 18WH WH .
Providing & fixing Lux Max Oyster -16/12 LED Post top fixtures made of Die Cast aluminium base and spun aluminium Top fitted with LED PT Module as per CAT No Lux Max PT 154- 40 Watt complete in all respect to the best satisfaction of engineer in charge along with suitable arrangement to protect the fitting from monkeys and other damages.
Providing & fixing UV System Water Purifier Aquaguard 7 litre capacity complete in all respect as approved & directed by engineer in charge.
Supply, installation, testing & commissioning of 2 TR(Hot & cold) split type air conditioning unit with remote of following make complete as required in all respect with Base Frame , Refrigent copper piping , Hard PVC /Flexible drain pipe, PVC Round Cover 50mm dia upto 6 mtrs. .(i) Voltas/Lloyd/LG/Blue Star
Supplying & fixing voltage stabilizer for 2TR capacity AC complete in all respect.
Providing & fixing of M.S. Outdoor heavy duty stand power coated suitable to hang 1.5 Split type AC with Anchor bolts as required complete in all respect and as per direction of Engineer in charge.
Supplying and erection Water Fire Extinguisher Gas Cartridge type ISI Marked conforming to IS: 15683 Capacity 9 litre complete with IS: 4947 gas cartridge, delivery hose horn, Squeeze grip release valve locking arrangement , operation manual and bracket.
Supplying and erection CO 2 type Fire Extinguisher ISI Marked conforming to IS: 15683 Capacity 4.5kg complete with delivery hose horn, wheel type release valve locking arrangement, operation manual and bracket.
Providing & Fixing Mech Key Tag Switches 32A 2M equivalent to CAT No. CB91302HW32
Providing & Fixing side table lamp of Philips/Decon make as required complete in all respect to the best satisfaction of engineer in charge.
Providing & Fixing LED Lamp of following capacity as approved & directed by engineer in charge of Syska/Havells/Bajaj 7 - 9 Watt
M/s Ravindra Electrical
Rakesh Kumar
ARUN KUMAR SHARMA
Kumar Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .