Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.8 LAccepted-AOC EAST DIGHI TANK OLD LIC COMPOUND GAYA BIHAR 823001 | GAYA | BIHAR | 823001 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹12.1 L+₹91,054 (8.12%)Rejected-Finance HOUSE NO 413 MAGADH COLONY SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹15.2 L+₹4.0 L (35.4%)Rejected-Finance WZ 484 M S BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹15.5 L+₹4.3 L (38.0%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹16.3 L+₹5.1 L (45.5%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | 5 | Rejected-Finance NOT LOWEST |
Tender Value
₹17.0 L
EMD Value
₹34,200
Closing Date
21 Mar 2022, 6:00 pmClosed
GE GAYA
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar-823001
Repair Maint of Refrigeration, Air Conditioning and allied works at Mil Stn Gaya
2022_MES_499618_3
8062/GE/E-8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GAYA
₹34,200
Yes
30 Mar 2022
15 Mar 2022
22 Mar 2022
15 Mar 2022
21 Mar 2022
16 Mar 2022
Amount
Comprehensive preventive & routine maintenance services of 1.5/2 TR window type air conditioner Make: Voltas/LG /Carrier/Blue Star or any other make on site installed at various location in the station by carrying out following checks and services:- (i) Cleaning of condenser and evaporator coils fins with mild detergent/chemical solution for descaling of coils and flushing with high-pressure jet of water after taking down the whole unit and refixing at the existing location or any other new location after servicing. (ii) Greasing of blower motors and all moving parts. (iii) Prevention of rusting of units (iv) Checking operation of controls of the air conditioner such as thermostat, relays, remote control etc. (v) Checking air flow through the supply air grill, return air grill, condenser. (vi) Checking air temperature at supply air grill, return air grill, inlet air condenser, outlet air from condenser. (vii) Checking firmness of supporting arrangement for the compressor, blower motor, air conditioners casing and fixing of air-conditioners etc., anti-rusting painting of the MS portion prone to rusting. (viii) Replacement of any component of air conditioners found defective after the above checks and tests
All as per item No. 1 above but for 1.5/2 TR split type air conditioner. Note for Item No. 1 & 2 (i) Cleaning, overhauling and servicing of each unit shall be carried out on quaterly basis. (ii) The AC units shall be checked completely and serviced/repaired thoroughly at least once in three months as prescribed by the manufacturer of the AC units. In addition to this AC units shall be attended on break down with in 24 hours after intimation and shall be get repaired with in 48 hours, failing which necessay recovery @ Rs 200 per AC per hrs shall be made. (iii) Items/parts required for repair/replacement shall be measured and paid separately under relevent items here-in-after as supply and fixing.
S & F in repair refrigerant copper piping of size 1/4" internal dia in and including synthetic rubber foam insulation for split type AC complete all as specified and directed. Note: The quoted rate is inclusive of necessary T&P, rope, ladder etc with safety equipment for execution the work upto G+ one storie building.
All as per item Srl No. 3 above but for 1/2" internal dia pipe.
Disconnecting, dismantling and taking out existing burnt out compressor from window/split type Air conditioner 1.5 TR Capacity and supply & fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filled with compressor oil complete all as specified by Engr-in-Charge and testing on load for 24 hrs in summer complete all as specified and directed. Make : Carrier/ Hitachi/ Tecumseh/ Usha/ Voltas/ Blue Star
All as per item No. 5 above but for 2 TR window/split type air conditioner.
S & F in repair copper condenser motor suitable for 1.5 / 2 TR split type AC of any make/ model complete all as specified and directed. Make: As per OEM
S & F in repair copper condenser coil suitable for 1.5 TR window type AC of any make/ model complete all as specified and directed. Make: As per OEM
S & F in repair starting capacitor of 80 to 100 mFd capacity, ISI marked for 1.5/2 TR capacity window/ split type AC Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron
S & F in repair running capacitor of 36 to 45 mFd capacity, ISI marked for 1.5/2 TR capacity window/ split type AC complete all as specified and directed. Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron
S & F in repair blower motor double shaft, single/double speed, single phase, AC 230 V of 1/6 to 1/4 HP capacity to suitable for window type AC complete all as specified and directed. Make: As per OEM
S & F in repair blower motor single shaft, single/double speed, single phase, AC 230 V suitable for indoor unit of split type AC of 1.5/ 2.0 TR capacity complete all as specified and directed. Make: As per OEM
S & F in repair fan blade set suitable for window type AC of any capacity complete all as specified and directed.
S & F in repair fan blade set suitable for split type AC of any capacity complete all as specified and directed.
S & F in repair remote control with PC board complete suitable for existing model of split type AC of any capacity complete all as specified and directed. Make: As per OEM
S & F in repair thermostat switch of existing make and capacity window/split type AC 1.5/2 Ton capacity complete all as specified and directed.
M & L for repair to electronic control kit (PCB Kit) of split/window type AC of any make/ capacity complete all as specified and directed.
S & F in replacement of indoor unit for 1.5/2 TR split type AC with temperature display kit incl all accessories etc complete all as specified and directed. Make: Blue Star/ Carrier/ Voltas/ Hitachi
M & L for repairing & rewinding CFM motor of split type AC or blower motor of window type AC complete all as specified and directed.
S & F in repair capilary and filter suitable for existing model of 1.5/2 TR window/split type AC complete all as specified and directed. Make: As per OEM
S & F in repair air filter suitable for existing model of 1.5/2 TR window type AC complete all as specified and directed. Make: As per OEM
S & F in repair air filter suitable for existing model of 1.5/2 TR split type AC complete all as specified and directed. Make: As per OEM
Supply and charging R-22 gas to maintain the required cooling effect as and when required in the split / window type AC or in any other cooling appliances complete all as specified and directed.
Supply and charging R-134 gas to maintain the required cooling effect as and when required in the water cooler, refrigerator, deep freezer or in any other cooling appliances complete all as specified and directed.
S & F in repair set of MS powder coated mounting brackets for 1.5/ 2.0 TR AC indoor unit, heavy duty including necessary expansion fasteners complete all as specified and directed.
S & F in repair set of MS powder coated mounting brackets for 1.5/ 2.0 TR AC outoor unit, heavy duty including necessary expansion fasteners complete all as specified and directed.
S & F in repair MS stand suitable for window type AC unit upto 2 ton of capacity made out of 40mm x 40mm x 5mm angle iron including fixing arrangments like welding, fabrication and nuts & bolts complete all as specified & directed.
Taking down carefully Split type AC of any capacity with all accessories such as indoor unit, out door unit, copper pipe inlet outlet, flair nut etc. and shifting new position after minor repair including making good the opening of old location with cement mortor 1:3, treating the wall to matching with existing surface finish and making opening holes on brick wall at new location and gap well finish with cement mortor 1:3, making good the wall surface to match with existing surface, installation and commissioning with replacement of insulation of suction & discharge line complete all as directed.complete all as specified and directed. Note: (i) Replacement of any defective parts shall be measured and paid separately. (ii) The charging of gas shall be measured and paid separately.
Taking out old burnt out compressor (sealed unit) for Refrigerator/Deep Freezer 170/210/285/310 ltr capacity and replaced with with new one compressor as per existing make including charging of gas upto required level and testing complete all as specified and directed by Engr-in-Charge. Note: The quantity of gas shall be measured and paid seperately under relevent item.
Taking out old burnt out compressor (sealed unit) complete from water cooler of any size/capacity and replaced with new one compressor as per existing make including charging of gas upto required level and testing complete all as specified and directed by Engr-in-Charge. Note: The quantity of gas shall be measured and paid seperately under relevent item.
S & F in repair starting relay box type for refrigerator/deep freezer complete all as specified and directed.
S & F in repair thermostat switch for refrigerator of any size as per existing make complete all as specified and directed.
S & F in repair door gasket with magnetic strip for refrigerator/Deep Freezer 310/285/165 ltrs capacity all as specified.
M & L for repairing and rewinding of blower motor of water cooler of any size capacity complete all as specified and directed.
S & F in repair starting cum over load relay with cover suitable for refrigerator/deep freezer/ water cooler complete all as specified and directed.
S & F in repair of running capacitor 20 to 30 mFd suitable for refrigerator/deep freezer/ water cooler complete all as specified and directed.
S & F in repair of starting capacitor 40 to 60 mFd suitable for refrigerator/deep freezer/ water cooler complete all as specified and directed.
S & F in repair submersible water pump of desert cooler 230 Volt AC, discharge not less than 750 LPH at head 0.75 mtrs, ISI marked complete all as specified and directed.
M & L for repairing and rewinding of fan motor of desert cooler with copper winding wire of existing gauge complete all as specified and directed.
S & F in replacement wood wool pad (Khaus) including wire mesh for desert cooler complete all as specified and directed. Make: as per sample.
S & F in replacement PVC insulated round sheathed copper conductor cable of size 23/0.076, 3 core, ISI marked as per IS:694 complete all as specified and directed.
S & F in replacement PVC insulated round sheathed copper conductor cable of size 40/0.076, 3 core, ISI marked as per IS:694 complete all as specified and directed.
S & F in replacement PVC insulated round sheathed copper conductor cable of size 2.5 Sqmm, 3 core ISI marked as per IS:694 complete all as specified and directed.
S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 4 KVA complete all as specified & directed.
S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified & directed.
Supply, install, testing and commissioning steel body desert cooler electric driven 230 Volts AC, having nominal air delivery/capacity 6000 CuM per hour with 120 ltrs sump capacity having filter panel, grill, top of cooler body, cabinet made out of galvanized steel sheet (ISI marked to IS:277 latest) with zinc coating of thickness (nominal) 0.8mm and for sump tank 1.0mm, Fan motor size 500mm ISI marked as per IS:996 (latest), submersible pump, honeycomb filter pads with non-corrosive wire guard with provision of float valve inlet including stand complete all as specified and directed. Make: Symphony/ Bajaj/ Havells/ Crompton Note: Old deteriorated/unserviceable desert cooler shall be deposite in AGE E/M store yard.
S & F in repair sheet metal enclosure for single pole and neutral with two pin and earth plug top and socket complete with one single pole MCB 20 Amps complete all as specified and directed. Make: ABB/Legrand/Havells
M & L in replacement AC submain wiring with PVC insulated unsheathed FRLS copper conductor cable, 1100 Volt grade, multistranded of two runs of single core of size 4 Sqmm and one run of single core 2.5 Sqmm (as earth wire) cable and connected of common earth dolly including drawn through and including non metalic rigid PVC conduit medium grade ISI marked with accessories complete all as specified and directed.
M/S CHAUHAN CONSTRUCTION
MS HARI MOHAN GUPTA
M/S VIKAS CONSTRUCTION CO.
New Era Engineers
M/S Sweta Construction
M/S ABHAY KUMAR AND BROTHERS
M/S ARJUN SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .