Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.7 L+₹2.5 L (6.88%)Rejected-Finance | L2 | Rejected-Finance Not Lowest |
Tender Value
₹46.5 L
EMD Value
₹92,920
Closing Date
14 Dec 2023, 6:00 pmClosed
GE NORTH PUNE
Garrison Engineer North General Cariappa Marg Camp Pune 411001
GE (N) P/TOKEN - 73 OF 2023-2024 PROVN OF INFRASTRUCTURE FOR LANDSAPING AND ARBORICULTURE AT MSSC AND PROVN OF BOREWELL WITH PUMPSETAND ACCESSORIES AT DEFENCE AUDITCOLONY UNDER GE (NORTH) PUNE
2023_MES_628824_1
GE (N) P/TOKEN - 73 OF 2023-2024
Open Tender
Civil Works
Item Rate
240 days
GE NORTH PUNE
Refer tender documents.
8 documents required · 8 mandatory
₹500
GE NORTH PUNE
₹92,920
Yes
8 Mar 2024
18 Nov 2023
21 Dec 2023
18 Nov 2023
14 Dec 2023
2 Dec 2023
20 Nov 2023 - 25 Nov 2023
Amount
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out hard/dense soil complete all as specified and directed.
M&L for excavating over area, n exc 1.5 m in depth for hard/dense soil complete all as directed
M&L for excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed.
M&L for PCC 1:4:8, type D-2 (40mm graded agg) as in foundations,filling and mass concrete complete all as specified and as directed.
M&L for RCC (Nominal mix)1:2:4, type B1 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified
M&L for RCC (Nominal mix)1:2:4, type B1 as in columns, pillars, piers,posts and struts complete all as specified
M&L for RCC (Nominal mix)1:2:4, type B1 as in beams, cantilevers,bressummers, lintels over 1.5m span complete all as specified
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter finished the surface fair & smooth complete all as directed
M&L for formwork to sides of pillars,posts, struts, piers, columns and stanchions etc rough finished surface of concrete complete all as directed
M&L fpr formwork to sides and soffits of floor or roof beams, lintels, cantilevers, shelves and similar work etc rough finished surface of concrete complete all as specified and directed
M&L for MS TMT bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl MS wire (annealed) not less than 0.9mm securing with clips complete all as specified and directed.
-Ditto- all as per tem No 11 above but 6-8 mm dia stirrups
M&L for pre-cast cement concrete block masonry with solid blocks exc. 10 cm in width,1:3:6 mix type C-1, (using 20mm graded stone aggregate) and setting in cement mortar 1:6 complete all as directed
M&L for 10mm thick cement plaster in CM 1:6 on bricks on concrete surfaces finishing the surfaces even and smooth without using extra cement all as specified.
M&L for preparation of new plastered surfaces and applying two coats of weather proof exterior emulsion paint ('APEX' brand of Asian or equivalent brand of Berger/Shalimar) over a coat of primer on wall complete all as specified and as directed by Engineer-in-charge.
Returning, filling in foundations, including spreading, levelling, watering and well ramming in layers not exc 25 cm of in soil complete all as specified and directed
Removing excavated soil exc 250 mtr but n exc 500 Mtr and depositing where directed at a level n exc. 1.5 m above the starting point of soil complete all as specified and directed
Filling soil under floors obtained from Item No 2 & 3 and levelling in layers n exc. 25 cm thick, well ramming including watering as required complete all as specified and directed
M&L for moorum filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as directed
M&L for hardcore of broken stone boulders n exc 63 mm gauge deposited, spread and levelled in layers as in sub base complete all as specified and directed
M&L for 100mm thick PCC 1:4:8 Mix type D-2, (using 40mm graded stone aggregate) as in sub base and similar work complete all as directed
M&L for Machine cut kota stone slab flooring 20-25mm thick laid over and including 15 mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms over and including 15 mm thick screed bed in CM 1:6 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as directed
Ditto as per item no 23 but in vertical surfaces incl 10 mm thick bacing coat in CM 1:4 complete all as specified and directed
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed
M&L for machine pressed precast cement concrete coloured interlocking paver blocks, glossy rubber moulded, of triangular / Zigzag / Haxagone/any shape/design and size as approved, 60mm thick, conforming to IS 15658-2006, M-35 with grey cement and pigments grade in floor/ paths/ pavement laid over and including 25mm thick sand cushioning laid dry to the profile including filling the joints with sand of any description complete all as specified and as directed.
S&F Stainless steel hand rail of grade 304 with round/squar/rectangular tube with three tier rails, baluster mirror polished and flush joints incl end caps fitted in steps complete all as specified and as directed
Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and as directed.
Removing Surplus soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
Supply and laying 50mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties plete with fittings for cable protection complete all as specified and as directed.
Supply, lay, joint, test and commissioning of LT under ground cable 1100 volt grade , XLPE insulated and PVC sheathed heavy duty armoured with aluminium conductor , IS 7098-I Marked, Laid in trenches/ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe including cable glands, lugs jointing material etc complete all as specified and directed. cable of the following size.
50 Sq mm 3.5 Core
10 Sq mm 4 Core
Supplied and fixed Four pole MCCB, Thermal Release Range 63-100 Amps, rupturing Breaking Capacity Icu at 415V AC 50Hz. 30 (kA) including sheet metal enclosure complete all as specified and as directed
S & F Integral decorative LED bollard with aluminium [pipe housing, glare free PMMA diffuser with IP 65 protection suitable for 09/10 watts LED bulb with necessary elecrical connections with adequate size including removal of old unserviceable one complete as all specified and as directed. Make Halonix Cat Part No HLOB-27-10-CW-1M, Jaquar LBLDCONO10XW, Shakti SZPGBMX009-F FRUSTUM or equivalent in Havells
S & F Rectangular pole mounted cable junction box suitable for 3 Phase 440 Volt , 20 Amps of size 130x130x77 mm ( IP 66 Protection) made out of SMC sheet not less than 3 mm thickness, cable entry at botton, left hinged door, with & including PVC Bus bar Terminal connection plate for cable connection, SP MCB 6 Amps, and MS clamps to secure box with pole , complete all as specified and as directed. Make Sintex of Equivalent
M & L Cement Concrete 1:3:6 type C1(20 mm graded aggregate) as in coping of pole etc including form work & finishing the surfaces even & smooth with out using extra cement complete including demolition of old PCC work all as specified
M& L for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty PVC concealed conduit including all accessories, Metal flush box of suitable module, with earth dolly, covered with twin colour (specified by Engr-in- Charge)modular white cover plate & frame after chasing in brick/stone masonry walls etc for accomodating modular switches, sockets, regulators etc including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed for the following
One light / wall / exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed
One ceiling fan point controlled by one, one way switch 6 Amps and regulator Note : PVC Casing caping / Pipe of size as required at site on surface of ceiling (only for fan point) in lieu of concealed is permitted and is deemed to be included in the unit rate quoated.
One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed
One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed
Description all as per 36 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point,16 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed
S & F Modular Switch - 6 Amps, Single pole one way, one module complete all as specified and as directed.
S & F Modular Switch - 16 Amps, Single pole one way, one module complete all as specified and as directed.
S & F Modular socket outlet multipurpose 6 Amps, 5 pin, 2 module, complete all as specified and as directed.
S & F Modular socket outlet multipurpose 16 Amps, 6 pin-shuttered type, 2 module, complete all as specified and as directed.
S & F modular fan step regulator, 120W - 2 module suitable for ( 48" & 56" fans) supply complete all as specified and as directed.
S & F Ceiling rose, 3 phase / PVC / polycarbonate, complete all as specified and as directed
S & F 20/22 Watt Inverter LED Battenaluminium body with Opal Diffuser, IP20, Battery back-up & Functioning as per Product TDS with intregrated electronic driver, connector block, holder, decorative end caps, LED tube light etc complete with all accessories prewired and mounting PVC rectangular block, including provision of flexible copper conductor cable of suitable size from ceiling rose to connector and taking down old unserviceable fitting from existing postion for carrying to store, making good disturbed surfaces complete all as specified and as directed. Make Halonix Cat No LED INVERTER BATTEN HLB-08-22-CW-INV or equivalent in Havells
S & F for Radiant LED step light 07 watts, enviromental friendly, new generation, energy saving, decorative ractangular shaped, IP66 for wall recess mounted, operating voltage 150 V-270 V AC, 50 Hz all as specified. Make-Havells Cat part No. RADIANTFTR07WLED830PSYMTOPC or equivalent in Phillips or Halonix.
S & F for LED down light recess mounted luminare, round/square type 15 watts as per site requirement with efficiency of 1500 lumens per watt, Series of downlighters with low depth round & larger dia, powder coated white finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver suitable for office spaces sleek design white finish operating voltage 150 V-270 V AC, 50 Hz all as specified. Make- JAQUAR Cat part No. LNEP01S015XN/LLCN01R01SXN, Halonix HLDLR31-15CW/ HLDLR-S27-15-CW,Philips DN296B LED 15S-6500 PSU WH.
S & F for wall mounted LED 06 watts (WW) or more, 3000K with good color rendering (CRI>70) picture light fitting, 230 volts with durable aluminium housing and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, including taking down old unsv fitting complete all as specified and as directed. Make :-Shakti cat part no SZWPFPX003 or Luker I-3, LIMR6 or Halonix
S & F ceiling fans working on single phase input voltage 140-285 , Sweep- 1200 mm, Power 32 W, 345 RPM , with 232 Air delivery CMM (m3 /min), complete with compact BLDC Motor, blades, down rods, electronic regulator and accessories, including making connections with provision of flexible wire 23 /0.0076 twin core copper conductor from ceiling rose/connector to fan complete all as specified & as directed.
S & F for sheet metal enclosures single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB SP 20/ 32Amps including removal of old unserviceable one complete all as specified and as directed.Make - Scheinder/Legrand/L&T/ ABB
S & F for wall mounted fan of size 400 mm sweep BEE. Five star rated ISI marked and connecting up including provision of cable from ceiling rose or connector to fan complete all as including removal of old unsv fan and handed over to store yard of AGE E/M (North) complete all as specified and directed. Note : a) Quoted Rate is deemed to inclusive of Stickering/Marking/writing of MES numbers in bottom of ceiling Fan as directed by Engr-in-Charge. Make:- Bajaj MIDEA BW 2200, USHA Pentacool, Havells V3,Atomberg
S & F sheet metal enclosure MCB DB SPN 8 way with 100 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed
S & F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning
S & F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning
Supply and fixing 415V, 10KA 'K' curve miniature circuit breaker (MCB) of 4 poles and 16 amp current carrying capacity in the Panel complete with connection testing and commissioning with necessary alteration required at site all as directed and specified by Engineer In charge Make L& T,Schneider,Legrand
S&F XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, including laying, jointing and testing complete all as specified and as directed with cross sectional area and core as given here in 10 Sq mm 4 core
S&F double wall corrugated high density polymer ethylene (HDPE) pipe for laying of electric cable of 63 mm outer dia and 51 mm inner dia with IS 14930 (Part2) 2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. Make : Jagannath Pipes, Mycorr, Tijaria,Astral
M&L for earthing complete with GI earth plate electrode 60x60cmx6.3mm thick and burried directly in ground (earth pit n not less than 2.25 meter deep below ground level) with top edge of the plate not less than 2.25 meter below normal ground level, connected to GI earth plate with GI strip of size 32x6 mm by means of bolts, nuts check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earthing test point complete, all as specified and including testing on completion including PCC pit (1:3:6) type C-1, 100 mm thick precast RCC cover in (1:2:4) reinforced with 8 mm dia MS round bar @ 75 c/c both way with 02 Nos lifting handles of 12mm dia MS plain bar, GI pipe 50 mm bore light grade GI pipe for earth lead protection etc complete all as specified and as directed. Note : GI strip beyond 7.5 meter shall be measured and paid seperately.
Supply, Installations, testing ,commissioning and taking down old unserviceable LT outdoor panel board by CPRI approved manufacturer having internal dimensions not less than 60 X 60X 30 cms with double door spring loaded self closing, with stopper only front side openable cubical type pedestal mounting type totally enclosed, fabricated with dust and weather proof and rating of IP 64 CRCA outer sheet of 3.00 mm thick and inner sheet not less than 2 mm as per IS, inner and outer compartment of Load Bearing and 1.6 mm thick for non-load Bearing suitable for 3 phase 4 wire system 415 volts bottom base channel of MS section not less than 50 mm x 50 mm x 5mm thickwith proper earthing arrangement. Finish of the panel shall be powder coated, dust & vermin proof of IP 65 compartment doors, all components mounted on iron sheet 2mm thick and having proper locking arrangement in both front including necessary foundation, brick/PCC masonary pillar in CM 1:6, plastering 1:4, 10mm thick with clearance atleast 1.2 m above ground level, including marking incoming , outgoing cables with glands etc name of feeders and comprising with supply and fixing of the following items and connecting and testing complete. (a) MCB "C" curve , 4 pole , 415 Volts of current rating 16 Amps, rupturing capacity 10 KA- 01 No Make:Hager Cat No.NCN416N,L& T BB40160D ,Schneider cat no.A9N4P16D.
Drilling of trial bore in any type of strata soil/ rock perfectly vertical 150 mm bore hole for 85 mtr depth by DTH method or any other approved method including formation of sample collection and discharge of water, shifting transportation of material and equipment and preparation etc complete all as specified and as directed. Note:- (a) Development of trial bore well along with other connected works will be executed only if adequate water boring strata is encountered during the drilling of trial bore. (b) Decision of the Accepting Officer in regard so to above shall be final and binding on be contractor and no claim whatever will be entertained in this regard. (c) The above quantities are for one bore wells.
Development of trial bore by reaming in following steps:- (a) From 150 mm to 200 mm reaming up to 225 mm for 20 RM from ground level
Development of tube well with 250 PSI and 750 cfm capacity air compressor and with 25% extra capacity pump by pumping muddy water.
Supply and fixing/lowering MS casing pipe class 'C' 150 mm dia 5.4mm thick duly ISI marked in random length of 4 to 7 mtrs plain end pipe jointed and welded with coupler ring continuosly welded through out the circumference of the pipe complete on both side all as specified for the tube well assembly. Make:- Tata, Jindal, Prakash Surya.
Material and labour for MS welded well cap of size 300mm dia 6mm thickness and similar to casing pipe including welding with angle iron/flat iron to casing pipe last piece left above ground including iron handle including necessary nuts, bolts etc all as specified.
Collection of water samples testing and submission of report for chemical and bacteriological analysis duly comparative with potability all as directed.
Supplying and collecting samples of soil at each level at 10 mtr in sample strata box submitting the same at AGE E/M subdivision as directed by Engr-in-Charge.
Conducting yield test of tube well by operating the pump set continuosly for a period of 8 HRs and measuring the discharge and drawdown of tube well at a suitable time interval as per the direction of engineer in charge including cost of energy, cost of installation of suitable measuring device and hire charges for pumping set of suitable capacity.
Supply, install,testing, commissioning of submerssible electrical driven pumpset of suitable capacity for discharge of (0 to 90 LPM) at (162 to 52 mtr ) head multistage, outlet size 40mm bore with suitable motor AC, 3 Phase, 415 volts, 50 Hz, water cooled , and including electrical connections, electric submerssible 6 sqmm 3 core flat copper cables, ( length and of size as required) with in-built NRV and water proof joints etc complete all as specified and directed.Having following material of construction Pump Housing : Stainless Steel Pump Shaft : Stainless Steel Motor Housing : Stainless Steel Motor Shaft : Stainless Steel Thrust Bearing : Carbon + Stainless Steel Motor/Pump Bushes : Gun Metal Impeller : Noryl Diffuser : Noryl NRV : Cast Iron Suction : Cast Iron Make: Kirloskar Model no.KS4C-3020#T,KSB,Wilo,Texmo
Supply and fix/ lowering High density poly ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 and bore 40 mm fixed complete in borewell etc. including necessary fittings such as tee,bends,elbow etc having bore sizes as following Of Make:SFMC ,Finolex,Supreme
Supply and fix water meter on line having specification as woltman type (Removable Mechanism) ,40 mm , magnetic drive with minimum reading 0.02 cum, thread type and bearing pressure of 20 kg/sqcm confirming to IS 779-1994 all as specified and directed. Make:Kranti,SIR,Electrosteel.
Supply and fix gun metal gate valve, cast/ductile screwed down, High pressure with iron wheel handle , Screwed both ends for iron pipe or unions of 40 mm bore complete all as specified and as directed Make: leader,Zoloto,GEM,Sant
Supply and fix Bib tap standard with dia 15 mm bore made of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm- 125gms).
Supply and fix in repairs nylon rope as per the site requirement for borewells with HDPE pipes
Material and labour for PCC 1:4:8 type D-2 (using 40mm grade stone aggregate) for earth pit including necessary form work complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) for earth pit including necessary form work complete all as specified and as directed.
Supply and lowering in repairs SUBMERSIBLE Flat Three Core PVC Insulated & PVC Sheathed Industrial Cable copper conductor mutistraned cable of size 3 core x 4 Sq mm for Submersible Pump Motor with necessary connections from Motor to starter complete with nessesary thimbles etc. all as specified.Make:Anchor ,Havells,Finolex
Supply and lay medium grade galvanized pipe of 40 mm bore with all fitting such as tee, bends, union elbow,bend, reducer in on borewell all as specified and directed by Engineer in charge .Make:Tata,Jindal,Prakash Surya
K.K.Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .