Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC 10 2 NARAYAN BAG INDORE M P | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.3 L+₹88,645 (6.61%)Rejected-Finance | L2 | Rejected-Finance Rates are high |
Tender Value
₹14.9 L
EMD Value
₹29,800
Closing Date
10 Feb 2020, 12:00 pmClosed
GE MIS MHOW
GE MAINT INF SCHOOL, 75 MALL RAOD MHOW
REPAIR RENEWAL IMPROVEMENT OF EXTERNAL ELECTRIC SUPPLY APFC PANEL AND OTHER CONNECTED WORK UNDER GE MIS MHOW
2020_MES_316707_1
GE MIS MHOW/61 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MIS MHOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE MIS MHOW
₹29,800
Yes
25 Aug 2020
21 Jan 2020
12 Feb 2020
27 Jan 2020
10 Feb 2020
4 Feb 2020
Amount
Repair/maintenance and painting with one coat of synthetic enamel paint for LT Panels, feeder pillar boxes, APFC panels, repair the panel body with existing size & thickness of MS plate, hooks, locking arrangement and match to the existing surface with existing colour inside and outside & repair the bus bar of any size and type and all as directed by Engr-in-charge. Note:- 1. MS sheet shall be measured and paid separately under respective items. 2. Welding work reqd for any panel is deemed to be included in the rate quoted.
Supply and fixing in replacement HD type, 440 V, 50 Hz Heavy duty cylindrical type power capacitor of size 25 KVAR to the existing APFC Panel and all as directed by Engr-in-charge. Make :- Neptune or equivalent in Havells.
Supply and fixing in replacement HD type, 440 V, 50 Hz Heavy duty cylindrical type power capacitor of size 12.5 KVAR to the existing APFC Panel and all as directed by Engr-in-charge. Make :- Neptune or equivalent in Havells.
Supply and fixing in replacement HD type, 440 V, 50 Hz Heavy duty cylindrical type power capacitor of size 6.25 KVAR to the existing APFC Panel and all as directed by Engr-in-charge. Make :- Neptune or equivalent in Havells.
Supply and fixing in replacement 8 step IPFC controller digital type in existing APFC Panel and all as directed by Engr-in-charge. Make :- Neptune or equivalent in Havells.
Supply and fixing in replacement box type power capacitor, heavy duty of size 5 KVAR, 480 V to the existing APFC Panel and all as directed by Engr-in-charge. Make :- Neptune or equivalent in Havells.
Supply and fixing in replacement box type power capacitor, heavy duty of size 10 KVAR, 480 V to the existing APFC Panel and all as directed by Engr-in-charge. Make :- Neptune or equivalent in Havells.
Supply and fixing in replacement box type power capacitor, heavy duty of size 15 KVAR, 480 V to the existing APFC Panel and all as directed by Engr-in-charge. Make :- Neptune or equivalent in Havells.
Supply and fixing in replacement box type power capacitor, heavy duty of size 25 KVAR, 480 V to the existing APFC Panel and all as directed by Engr-in-charge. Make :- Neptune or equivalent in Havells.
Supply and fixing in replacement box type power capacitor, heavy duty of size 75 KVAR, 480 V to the existing APFC Panel and all as directed by Engr-in-charge. Make :- Neptune or equivalent in Havells.
Supply and fixing in replacement box type power capacitor, heavy duty of size 100 KVAR, 480 V to the existing APFC Panel and all as directed by Engr-in-charge. Make :- Neptune or equivalent in Havells.
Supply and fixing in replacement aluminium reactor of size 50 KVAR to the existing APFC panel and as directed by Engr-in-charge.
Supply and fixing in replacement aluminium reactor of size 75 KVAR to the existing APFC panel and as directed by Engr-in-charge.
Supply and fixing in replacement aluminium reactor of size 100 KVAR to the existing APFC panel and as directed by Engr-in-charge.
Supply and fixing in replacement of 12 stage relay NAAC 3)-12 to the existing APFC panel and as directed by Engr-in-Charge. Make :- Havells/Indoasian/L&T
All as per Item No 15 above but of size 8 stage NAAC 3P-8 complete all as specified & directed. Make :- Havells/Indoasian/L&T
Supply only 3mm thick MS sheet for panels.
Supply, fixing in replacement of ACB with testing complet, 415 V, 1250 Amps, 50 Hz FP/TP manual fixed type alongwith suitable size of CT's all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement Power contactor 3P, 330 Amps, 50 Hz all as specified and as directed by Engr-in-Charge. Make :- Havells/Indo asian/Nepute
Supply and fixing in replacement Power contactor 3P, 225 Amps, 50 Hz all as specified and as directed by Engr-in-Charge. Make :- Havells/Indo asian/Nepute
Supply & Fixing in replacement MCCB TP, adjustable type, 415V, 200 Amps, 36 KA Make:- Havells/Indoasian/L&T
Supply & Fixing in replacement MCCB TP, adjustable type, 415V, 250 Amps, 36 KA Make:- Havells/Indoasian/L&T
Supply & Fixing in replacement MCCB TP, adjustable type, 415V, 160 Amps, 36 KA Make:- Havells/Indoasian/L&T
Supply and fixing in repair PVC insulated wire S/C of multistranded type of size 70 sqmm complete all as directed. Make :- Havells/Indo asian/Polycab
Supply, fixing and connecting in replacement of Digital type 3 phase 4 wire Kwh meter counter type LT, CT operated fully tampered proof, 240V, 5-10 A with LCD display and incl polycarbonate body covcer and connecting with CT of suitable size, complete all as specified and as directed . Make :- L&T WM301BC3C00 or equivalent in HPL/Secure/Schiender.
Supply and fix in repairs batteries of battery bank of 180 Ah, maintenance free. Make :- Exide/Amron
Supply and fixing in repair of information board of size 4.0x0.4 m of 2 mm flex board box type duly fixed LED tube light fitting alongwith suitable size of cable for connection complete with top plug and angle iron frame duly welded and painting copletely. Lay out Sketch to be approved by Engr-in-Charge. Note :- The information writing over board will be given by Engr-in-Charge at site complete all as specified and directed.
Supply laying & testing in replacement of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of sizes:- (35 Sqmm 3.5 core).
Supply laying & testing in replacement of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of sizes:- (50 Sqmm 3.5 core).
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M & L for sand cushioning to under ground cable as per SSR part-I Clause : 19.75 complete all as specified and directed.
Supply and laying in replacment of Old size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and directed.
Ms Kailash Chandra Babulal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .