Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.1 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹48.6 L+₹1.2 L (2.43%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹49.9 L+₹2.4 L (5.15%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹50.0 L+₹2.5 L (5.29%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹50.0 L+₹2.6 L (5.37%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
6 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
R S SHUKLA EE
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR MAINT TO CERTAIN BUILDINGS AND MISC ITEMS AAD CENTRE AD RECORDS AND 28 AD AREA AT GE I GOS
2021_MES_413380_1
8000/75/20-21/0976/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR MILITARY STATION
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹88,000
Yes
16 Feb 2021
16 Jan 2021
8 Feb 2021
16 Jan 2021
6 Feb 2021
30 Jan 2021
60 days
Amount
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 100 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed.
M&L for Machine cut kota stone slab flooring mirror finished 18-20 mm thick (each slab not less than 0.25 Sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 20 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and polishing complete all as specified and directed.
M&L for Machine cut kota stone in riser of steps, skirting, dado and pillar mirror finished 20-25 mm thick over cement base rendering laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 15 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and polishing complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed.
M&L Vitrified Ceramic tiles 10 mm thick (square/ rectagular) dark/colour shade polished,area of each tiles not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floors over 20mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per item no. 7 above but on vertical surface of wall of size 600x600x10mm thick as in dado/skirting including 10 mm thick rendering in CM 1:4 complete all as specified and directed
M&L for glazed ceramic tiles in vertical surface 200x300x7 mm thick coloured on vertical surfaces such as dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , including 10mm thick rendering in CM 1 :4 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
All as per item no.11 above but vertical surfaces area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm as skirting non skid ceramic tiles
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
All as per item no.13 above but vertical surfaces area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm as skirting non skid ceramic tiles
M&L for 100 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for cement concrete tiles of size 250 mm x 250 mm x 20-22 mm thick machine pressed set jointed and pointed in neat cement slurry in floor and cut and polished with grey cement and pigment, including 20 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L moorum / red bajri filling in floors or pavings laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for sand cushioning including spreading in layers and rolled consolidated to thickness of 50mm (minimum) for receiving precast PCC interlocking blocks complete all as specified and directed
S&F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removal of rubbish from site complete all as specified and directed.
M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed
M&L for RCC (nominal mix) 1:2:4 type B-O using 12.5 mm graded stone aggregate as in slab supported on wall,beam and column in floors, roofs, landings, balconies, canopies and in shelves and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately.
Mild Steel TMT bar 5mm dia and over upto and including 10mm dia as in stirrups, spacers & binders cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M&L for rendering on other than fair faces of brick work or concrete surface of wall 15mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate, 75mm thick in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed. Note : Joints 12mm wide to the full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provision shall be deemed to be included in the quoted rate for concrete in plinth protection.
M&L for 100mm thick PCC 1:2:4 Type B-2 using 40mm graded stone aggregate in pavement/hard-standing laid in alternative panels, surface finished even and smooth without using extra cement, including necessary form work, complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering on other than fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick or concrete surface of wall and finished even and smooth with out using extra cement and mixed with water proofing compound complete all as specified and directed. (Note: supply only of WPC shall be measured and paid for seperately )
M&L for preparation of newly plastered surfaces of walls and applying three coat of white wash complete all as specified and directed.
M & L for two coats of cement based paint on new plastered surface of walls including preparation of surface complete all as specified and directed.
Taking down rolling shutters of any size complete all as specified & directed
Supply and fixing of steel rolling shutters as per IS-6248-1979, made of required size MS laths interlocked together through their entire length and jointed together at the ends by end locks mounted on shafts (50 mm dia) heavy duty, thickness of lathe 1.20mm, grade II springs, guide channel 3.15mm thick, bottom plate 3.15mm thick gear oprated shutter with bevel gear box and crank handle, hood cover 1.20mm and 1 coat of red oxide primer including necessary concrete bed blocks with PCC 1:3:6 of size wall width x 150mm x300 mm and finishing with plaster 15mm thick in CM 1:4 finished even and smooth complete all as specified and directed.
S&F ball bearing suitable for rolling shutter compete all as specifed & directed.
S&F safety lever locks with four levers for rolling shutters complete all as specified and directed.
S & F MS pipe 50 to 125 mm dia as shaft including two coats of aluminum paint over a coat red oxide primer complete all as specifed & directed.
Supply only following parts of steel rolling shutters (a) Gear Box Set general.
(b) Guide channel 3" (3.15 mm)
(c) Bottom plate 5" (2.25mm)
Greasing and servicing only to existing rolling shutters complete area of shutter n exc 20 Sqm each.
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
V.Venkata Ramaiah
M/s MAA BHAIRABI ENTERPRISES
M/S JAGANNATH SASMAL
M/S SIWALIK AND CO
G.KRISHNA MURTHY AND PARTNERS
DHABALESWAR ENGINEERING WORKS
M/s Ats Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .