Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance B 73 SECTOR 80 NOIDA NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201305 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201305 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 303 MAHESH NANGIA 303 PRAGATI CHAMBERS RANJIT NAGAR COMMERCAIL COMPLEX RANJIT NAGAR COMMERCIAL COMPLEX | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹2.7 Cr
EMD Value
₹2.7 L
Closing Date
20 Jul 2020, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
General Manager/CP
3rd Floor, RITES Bhawan-II, Plot No. 144, Sector-44, Gurgaon- 122003
Supply, Installation, Testing and Commissioning of Substation-3 near Boys Hostel at Central University of Karnataka, Kalaburagi
2020_RITES_52157_1
RITES/CP/CUK/GUL/EXT/SS-3/20
Open Tender
Electrical Works
Works
210 days
Central University of Karnataka, Kalaburagi
Please refer Tender Document
5 documents required · 5 mandatory
₹8,000
RITES Ltd.
₹2.7 L
21 Jul 2020
3 Jul 2020
21 Jul 2020
3 Jul 2020
20 Jul 2020
15 Jul 2020
4 Jul 2020 - 13 Jul 2020
90 days
Amount
Total Amount of BoQ 2
Amount after unconditional Rebate
Description of Work / Item(s)
Amount
Total of BoQ 3, BoQ 4 and BoQ 5
Total Amount of BoQ3 (Item Rate)
Total Amount of BoQ4 (Percentage Rate)
Total Amount of BoQ5 (Percentage Rate)
Description of Work / Item(s)
Amount
BILL OF QUANTITIES for Non Schedule Items (MR ITEMS) (CIVIL)
NSR 1-Diluting and injecting of chemical emulsion for pre constructional anti termite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, treatment of soil under apron is to be laid, top surface of plinth filling junction of wall and floor, along with the external perimeter of the building, expansion joint, surrounding of pipes and conduits etc., complete as per IS:6313 (plinth area of the building at ground floor only shall be measured for payment).(Rate including the cost of chemical emulsion)
NSR 2-Brick work with flyash F.P.S. brick of class designation 7.5 up to plinth level in cement mortar 1:6 (1 cement: 6 coarse sand). The rate including of materials, labours, transportation etc complete..
NSR 3-Brick work with flyash brick of class designation 7.5 in superstructure above plinth level up to floor five level in : The rate including of materials, labours, scaffolding, transportation etc complete.. - Cement mortar 1:6 (1 cement : 6 Coarse sand)
BILL OF QUANTITIES for Non Schedule Items (MR ITEMS) (ELECTRICAL)
11kV Single Panel HT VCB at Academic Substation
NSR-1-Supplying, installation,testing and commissioning of Indoor Extendable Type HT Panel with 11KV, 800A, 26.3kA, draw out type VCB Circuit Breaker with MiCOM P127 Relay, suitable size of Copper Bus bar for Main and Interconnecting switchgear with adopter box(Existing Busbar Connecting to Proposed VCB Panel). Incoming Voltmeter analog meter only used. Motorised spring charge mechanism suitable for 240V AC, Closing & Tripping coils rated 110V DC. The HT Panel shall be of IP4X protection. The HT Panel shall be suitable to accommodate cables for one feeder with neccessary cable boxes and accessories complete as required.
11kV Three Panel HT VCB at Substation 3 ( Near Boys Hostel Building)
NSR-2-Supplying,installing,testing and commissioning of Outdoor Type Floor Mounted metal clad, 11KV VCB, 26.3 KA Panel with 1No 800 Amps HT VCB as Incoming and 2 Nos 800 Amps HT VCB as Outgoing, totally enclosed fully interlocked, horizontal draw out, horizontal isolation type breaker as per IS 13118, having capacity mentioned below, single break, trip free mechanism,motorized charged, motorized closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz AC Supply,AIr insulated Copper Bus bars of 800 Amps capacity, breaker featured with mechanical ON / OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with the following switchgear and accessories.
Incoming .. 800 Amps TP VCB with MiCOM P127 Relay and Mechanical Interlock .. 1 No
Outgoing .. A) 800 Amps TP VCB with P111 relay .. 1 No (Tranformer Incoming)
B) 800 Amps TP VCB with P111 relay .. 1 No (Spare)
Note: Future Extendable.
RELAY
NSR-3-Supply and fixing of change the existing relay (P111) for Existing Academic SS Incoming VCB Panel, to provided MiCOMP-127 Relay
HT CABLE
Supplying,Testing and commissioning of the following 11 KV HT XLPE aluminium UG cable Earthed with conductor screened with extruded semi conducting compound XLPE insulated, insulation screened with semi conducting compound in combination with copper Tape (0.3 LA for one sec) cores laid up, inner sheath of PVC Tape, Galvanized steel flat strip Armored and over all PVC sheathed cable confirming to IS 7098/II/85 with latest amendment.
NSR-4-3 Core x 240 sqmm 11KV (E)HT XLPE Aluminium Cable
NSR-5-3 Core x 400 sqmm 11KV (E)HT XLPE Aluminium Cable
HT CABLE END TERMINATIONS
Supplying, making,testing and commissioning indoor cable end termination with heat shrinkable jointing kit complete all accessories including lugs suitable for following size of 11 KV XLPE cable
NSR-6-3C x 400 sq mm 11KV XLPE (E) cable
HT CABLE JOINT
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete all accessories including ferrules suitable for following size of 11 KV XLPE cable
NSR-7-3C x 400 sq mm 11KV XLPE (E) cable
TRANSFORMER
500 KVA 11kV / 433V Oil filled Transformer
NSR-8-Supply, Unloading, Erection, Testing and commissioning of INDOOR type Distribution transformer 11 KV/433 V. 500 KVA DELTA/star (DYN11), Oil Type, 4.5% Impedance, 3Phase 50Hz core type winding with OLTC, RTCC cum AVR panel, etc. with HV side cable box & LT Side cable box. Power Transformer with Winding Temperature alarm and trip, Oil Temperature alarm and Trip, Buchwald Alarm and trip with standard fittings with On load tap changer (On OLTC)
LT PANELS
Supply, installation, testing and commissioning of L.T Panels suitable for 415V, 3Phase, 4 wire, 50Hz distribution system. The panel shall be free standing, floor mounting, sheet metal enclosed, flush front with aluminium bus bar per sq.mm 0.7 Amp factor, separate earth bus shall be provided throughout the length of the panel. The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, meters etc. shall be accommodated in a modular multi tier arrangement. A minimum of 400mm clearance shall be given from the floor level to the bottom most termination point. The painting shall be done in conformity with IS Code. Adequate size cable alley shall be provided all round the panel and at the back for easy bending and terminations. The outgoing feeders inside the panel shall be connected through solid busbars. Flexible cable links are not acceptable. Busbars shall be provided with PVC heat shrinkable. The panel shall be fabricated only after the approval of fabrication drawing by the consultant.
Supplying, erecting, connecting, testing and commissioning of the following LT Panels
NSR-9-MAIN LT PANEL-3 at Substation 3 - Boys Hostel
EB Incoming
Mircroprocessed Based 1000Amps 4P, 50kA, ACB EDO Type with O/C, S/C & E/F Releases - 1 No with Shunt Trip. Over current, Short Circuit Earth Fault Relays shall be provided with Shunt Trip (220 V AC)
DG Incoming-1
Mircroprocessed Based 630Amps 4P, 50kA, ACB Type with O/C, S/C & E/F Releases - 1 No with Shunt Trip. Over current, Short Circuit Earth Fault Relays shall be provided with Shunt Trip (220 V AC)
DG Incoming-2
Mircroprocessed Based 630Amps 4P, 50kA, ACB EDO Type with O/C, S/C & E/F Releases - 1 No with Shunt Trip. Over current, Short Circuit Earth Fault Relays shall be provided with Shunt Trip (220 V AC)
Bus Coupler
Mircroprocessed Based 1000Amps 4P, 50kA, ACB EDO Type with O/C, S/C & E/F Releases - 1 No with Shunt Trip. Over current, Short Circuit Earth Fault Relays shall be provided with Shunt Trip (220 V AC)
Outgoing
630Amps 4P MCCB 50kA(Ics) withstanding capacity Adjustable over Load and Short Circuit Releases with digital multifunction meter - 2Nos
400 Amps 4P MCCB 36kA(Ics) withstanding capacity with Adjustable over Load and Short Circuit Releases with digital multifunction meter -4Nos
250Amps 4P MCCB 25kA(Ics) withstanding capacity with Adjustable over Load and Short Circuit Releases with digital multifunction meter - 2Nos
125Amps 4P MCCB 25kA(Ics) withstanding capacity with Adjustable over Load and Short Circuit Releases with digital multifunction meter - 2Nos
Interlockn a) Electrical Interlock Between EB Incoming and DG Incoming-1.
Note 01. All Outgoing MCCBs shall have Adjustable Overload and Short Circuit settings 02. The withstanding capacity shall be Ics only.
Busbar : Aluminium
Rating : 1000 Amps TPN Busbar
The Phase bus bar shall be 120 x 10 mm Al. bars and Neutral bar shall be 60 x10 mm. The Earth bar shall be 2 Runs of 50 x 6 mm. Al. bar.
There shall be Metering Compartment (EB) incorporated with the following:- i) 3Nos. Dual Core Cast Resin CTs of ratio 1000/5 A of Class 1.0 for measurement and class 5P 10 for Protection. The CT burden shall be 15 VA. ii) 1 No. Cast Resin CTs of ratio 1000/ 5 A of Class 1.0 for measurement for APFC Panel. The CT burden shall be 15VA iii) 1 No. SCHNEIDER EM 6400 Demand Controller. iv) RYB LED Cluster Type Indicating Lamps and Control fuses shall be provided.
There shall be Metering Compartment (DG) incorporated with the following:- i) 3Nos. Dual Core Cast Resin CTs of ratio 400/5 A of Class 1.0 for measurement and class 5P 10 for Protection. The CT burden shall be 15 VA. ii) 1 No. ENERCON MAKE (OR) Equivalent LOAD MANAGER EM 3480 iii) RYB LED Cluster Type Indicating Lamps and Control fuses shall be provided.
NSR-10-APFCR Capacitor Panel 3 - 200 KVAR at Substation 3 - Boys Hostel Block
INCOMING:
630Amps TP+N MCCB 50kA(Ics) withstanding capacity with Adjustable over Load and Short Circuit Releases .. 1 No
OUTGOING:
b) 250A TP+N MCCB, 25 KA (Ics) with adjustable over load and short circuit relays .. 2 Nos
b) 125A TP+N MCCB 25KA (Ics) with adjustable over load and short circuit relays .. 6 Nos
c) 8 stage Automatic power factor correction relay with following arrangement for power factor controlling
d) 2 Set of 110A capacitor duty Contractor and 50KVAR heavy duty double die electric capacitor bank
e) 4 Set of 70A heavy capacitor Contractor and 25KVAR heavy duty double die electric capacitor bank
i) The withstanding capacity mentioned shall be Ics only ii) All the MCCBs shall be with Adjustable overload and short circuit relays. iii) On / Off Indicating lamps shall be provided in all outgoings iv) Primary Voltage of Meter is 440V AC
An 8-Step APFC Relay with transducer shall be incorporated to maintain the power factor. The Panel shall also be made suitable to accommodate the following Capacitor Banks with all interconnections. 50 KVAR .. 2 Nos. 25 KVAR .. 4 Nos. 25 KVAR .. 2 Nos (Future Provisions)
Bus bars : Aluminium
rating : 630 Amps
The Phase Bus bar shall be 100 x 10 mm.and the Neutral bar shall be 50 x 10 mm.Al. bar The Earth Bus bar shall be 2 Runs of 50 x 6 mm.
NSR-11-supply and erection of powder coated floor mounting MLSB panel. The suitable size of aluminium bus bar (0.7 Amp per sq.mm) for main and interconnecting switchgear, Electronic digital multifunction meter for measuring KWh(Volt, Amps, Frequency, Power Factor and KWh) with necessary CT's,3 phase indication lamp and earthing as per requirement of CEIG and IE regulation. For the provision of following rated switchgear in the panel. 630A TPN Aluminum Bus Bar. The Phase Bus bar shall be 100 x 10 mm.and the Neutral bar shall be 50 x 10 mm.Al. bar. The Earth Bus bar shall be 2 Runs of 50 x 6 mm. 630A 4P MCCB 50KA -1No 400A 4P MCCB 36KA -3Nos 250A 4P MCCB 25KA -3Nos 125A 4P MCCB 25KA -2Nos
NSR-12-supply and erection of powder coated floor mounting Common Power panel. The suitable size of aluminium bus bar (0.7 Amp per sq.mm) for main and interconnecting switchgear, Electronic digital multifunction meter for measuring KWh(Volt, Amps, Frequency, Power Factor and KWh) with necessary CT's,3 phase indication lamp and earthing as per requirement of CEIG and IE regulation. For the provision of following rated switchgear in the panel. 400A TPN Aluminum Bus Bar. The Phase Bus bar shall be 100 x 6 mm.and the Neutral bar shall be 50 x 6 mm.Al. bar. The Earth Bus bar shall be 2 Runs of 50 x 3 mm. 400A 4P MCCB 36KA -1No 250A 4P MCCB 25KA -4Nos 125A 4P MCCB 25KA -2Nos 63A 4P MCCB 16KA -2Nos
OUT DOOR FEEDER PILLARS
Design, manufacture, supplying fixing in position, testing and commissioning of the following double door front operated Feeder Pillar Type outdoor, cubical type, front access 2 mm thick steel enclosed free standing, dust and vermine proof, switchboard with IP 65 protection with hinged and lockable doors glands, bonding to earth painting and danger board etc. suitable for use at 415 volts 3 phase 4 wire 50 Hz system and with 31 mVA rupturing capacity at 415 volts.
Feeder Pillar shall have provision for entry of cables from bottom as required.
All live accessable parts shall be surrounded and all equipments shall be finger touch proof. The busbar installation shall be with heat shrinkable sleeves. SMC/DMC surrounds and bus bar supports shall be used. Pad locking facility shall be provided on all outgoing feeder doors and switch handles shall be lockable in OFF position.
Feeder Piller complete in all respects suitable for mounting on pedestal made of PCC
NSR-13-supply and erection of powder coated floor mounting Outdoor Feeder Pillar-1 LSSB panel. The suitable size of aluminium bus bar (0.7 Amp per sq.mm) for main and interconnecting switchgear, Electronic digital multifunction meter for measuring KWh(Volt, Amps, Frequency, Power Factor and KWh) with necessary CT's,3 phase indication lamp and earthing as per requirement of CEIG and IE regulation. For the provision of following rated switchgear in the panel 400A TPN Aluminum Bus Bar. The Phase Bus bar shall be 100 x 6 mm.and the Neutral bar shall be 50 x 6 mm.Al. bar. The Earth Bus bar shall be 2 Runs of 50 x 3 mm. 400A 4P MCCB 36KA -1No 250A 4P MCCB 25KA -1No 200A 4P MCCB 25KA -2Nos 100A 4P MCCB 16KA -3Nos
NSR-14-supply and erection of powder coated floor mounting Outdoor Feeder Pillar-2 PSSB panel. The suitable size of aluminium bus bar (0.7 Amp per sq.mm) for main and interconnecting switchgear, Electronic digital multifunction meter for measuring KWh(Volt, Amps, Frequency, Power Factor and KWh) with necessary CT's,3 phase indication lamp and earthing as per requirement of CEIG and IE regulation. For the provision of following rated switchgear in the panel. 400A TPN Aluminum Bus Bar. The Phase Bus bar shall be 100 x 6 mm.and the Neutral bar shall be 50 x 6 mm.Al. bar. The Earth Bus bar shall be 2 Runs of 50 x 3 mm. 400A 4P MCCB 36KA -1No 250A 4P MCCB 25KA -1No 200A 4P MCCB 25KA -2Nos 125A 4P MCCB 25KA -3Nos
LIGHT FITTINGS
NSR-15-Supply and fixing of surface mounted 38W LED Fittings with lamp, similar to Philips BN108C LED 40S PSU NW WH or Equivalent.
NSR-16-Supply and fixing of 10W LED Bulk head Fittings with lamp, similar to Philips WT202W LED6S NW PSU S2 PC Or Equivalent.
NSR-17-Supply and fixing of 36W LED Street Light fitting with 3 Feet GI Pipe including all accessories, Similar to Philips Green Line BRP409 LED36 MR CW or Equivalent.
EXHAUST FAN
NSR-18-supply and fixing of 300 mm sweep Exhaust fan medium Duty air vent with double bearing and dimetallic blade.(Make: Havell's or Equivalent)
NSR-19-Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63A (Four Pole)
NSR-20-Supplying and fixing of following rating, 240/415 volts,Residual Circuit Breaker with overload protection (RCBO) following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
ii. 40A 100mA Double Pole
DISTRIBUTION BOARDS
NSR-21-Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, 7 Segment distribution Board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required
MV CABLE
Supply of PVC / XLPE insulated armoured cables with aluminium conductors for working voltages up to and including 1100V confirming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE.
NSR-22-4C X 16 Sq.mm, Al. Ar. Cable
NSR-23-3.5C X 120 Sq.mm Al. Ar. Cable
NSR-24-3.5C X 150 Sq.mm Al. Ar. Cable
NSR-25-3.5C X 240 Sq.mm Al. Ar. Cable
NSR-26-3.5C X 400 Sq.mm Al. Ar. Cable
Supply of following size of PVC insulated and PVC sheathed/XLPE Copper conductor cable of 1.1 KV grade as required.
NSR-27-4CX2.5 Sq mm Cu. Ar. Cable
Supplying, terminating, testing and commissioning of End termination of aluminium/copper conductor, including supply of single compression, type tinned brass cable glands, suitable size tinned copper crimping type lugs, including gland earthing as required.
NSR-28-4CX2.5 Sq mm Cu. Ar. Cable
EARTHING
NSR-29-Providing and fixing of 50 mm X 6 mm G.I stirp on surface or in recess for Body Earthing connections etc. as required.
STREET LIGHT
NSR-30-Supply and fixing of Green Line Xtra Range Street Light Fitting Similar To Philips BRP322 LED 110CW HE MR FG S3 XT or Equivalent.
NSR-31-Supply and erection of 9Mtr high Hot Dip Galvanised Octagonal Pole with Bottom 175mm A/F, top 70mm A/F made of 3mm thick. HT sheet steel plate along wth 275x275x20mm base plate, 1Mtr Long Single Arm Bracket suitable for the above octagonal pole, M24X 750mm long 'J' Type foundation bolts (EN 8 grade) and Bakellite sheet with 6A single Pole MCB & Standard terminals (for mounting inside the base compartment of pole. Similar to Bajaj or Equivalent
Street light DB with timer controller
NSR-32-Supply, erection, testing and commissioning of outdoor type Street light Distribution feeder pillar suitable mounting angle with 14 SWG CRCA plain black sheet steel enclosure to accomodate 6 way TPN MCB DB with 32A 4P MCB -1No as incomer and 10A SP MCB -5Nos as outgoing for street light power distribution and one no of 24 hrs timer with 25A power contactor for automatic ON/OFF indicator with all material required.32A TPN Aluminium Bus Bar. The Phase Bus bar shall be 25 x 3 mm.and the Neutral bar shall be 25 x 1.5 mm.Al. bar. The Earth Bus bar shall be 2 Runs of 25 x 1.5 mm.
DG SETS
200 KVA DG SET with Acoustic Enclosure
NSR-33-Supplying, erecting, connecting, testing and commissioning of 160 KW / 200 KVA, SILENT Diesel Generating Set and Automatic Main Failure (AMF) Panel with CPCB II approved acoustic enclosure comprising of : “Cummins” Model QSB 6.7 G12, Radiator Cooled, Diesel engine developing 256 BHP at 1500 RPM, complete with standard accessories. coupled to “Stamford” Alternator rated at 160 KW / 200 KVA at 415 Volts, mounted on Channel Iron Base Frame complete with Fuel Tank of 370 Ltrs capacity with Manual Control Panel and 02 nos 12 V Batteries.
ADVANCED LIGHTNING ARRESTOR
NSR-34-Supplying, erecting, connecting and commissioning the Advanced Ionosphere, with the following and necessary foundation plate, mounting screws / bolts, another associated accessories to complete the system to function. 75KV 36mm dia special coppercable (only meant for these applications) in GI pipe for protection of the cable withnecessary accessories as required . Eath Gel in the Earth Electrode with necessary accessories as required by thesystem. a Lightning Event Counter of digital type in weather proof enclosure with necessary accessories. Testing and commissioning of the System (Lump sum)
SAFETY EQUIPMENTS
NSR-35-10 Kg Co2 Fire Extinguisher properly fixed on the wall - 3 Nos
Fire BUCKET round bottom of 9 Lts with floor mounting stand for keeping four nos fore buckets & wall hook 22 to 25 cm projection for keeping fire buckets - 3 Nos
Printed instruction chart both in English and Local Language - English - 3 Nos
Pair of rubber gloves for 11 KV and 415 V - 4 Nos
6 mm thick rubber mat - 3Nos
2 mm thick rubber mat - 5 Nos
Standard first aid box - 2 Nos
Bidder Name
Amount
Shree Tuuljai Electrical Pvt. Ltd
SHANTI ENTERPRISES ELECTRICALS PRIVATE LIMITED
TECHNISYS ENGINEERING PRIVATE LIMITED
GEETU ENGINEERING AND CONSTRUCTIONS PVT LTD
POWERSOL INFRA SERVICES PRIVATE LIMITED
Rekha Enterprises
GNG Limited
HITECH ERECTORS PVT. LTD.
Reliable Diesel Engineers Pvt Ltd
Bidder Name
Amount
Shree Tuuljai Electrical Pvt. Ltd
SHANTI ENTERPRISES ELECTRICALS PRIVATE LIMITED
TECHNISYS ENGINEERING PRIVATE LIMITED
GEETU ENGINEERING AND CONSTRUCTIONS PVT LTD
POWERSOL INFRA SERVICES PRIVATE LIMITED
Rekha Enterprises
GNG Limited
HITECH ERECTORS PVT. LTD.
Reliable Diesel Engineers Pvt Ltd
GEETU ENGINEERING AND CONSTRUCTIONS PVT LTD
Rekha Enterprises
HITECH ERECTORS PVT. LTD.
Shree Tuuljai Electrical Pvt. Ltd
Reliable Diesel Engineers Pvt Ltd
SHANTI ENTERPRISES ELECTRICALS PRIVATE LIMITED
POWERSOL INFRA SERVICES PRIVATE LIMITED
GNG Limited
GEETU ENGINEERING AND CONSTRUCTIONS PVT LTD
HITECH ERECTORS PVT. LTD.
Shree Tuuljai Electrical Pvt. Ltd
Rekha Enterprises
Reliable Diesel Engineers Pvt Ltd
SHANTI ENTERPRISES ELECTRICALS PRIVATE LIMITED
POWERSOL INFRA SERVICES PRIVATE LIMITED
GNG Limited
GEETU ENGINEERING AND CONSTRUCTIONS PVT LTD
SHANTI ENTERPRISES ELECTRICALS PRIVATE LIMITED
Shree Tuuljai Electrical Pvt. Ltd
HITECH ERECTORS PVT. LTD.
Rekha Enterprises
Reliable Diesel Engineers Pvt Ltd
POWERSOL INFRA SERVICES PRIVATE LIMITED
GNG Limited
GEETU ENGINEERING AND CONSTRUCTIONS PVT LTD
TECHNISYS ENGINEERING PRIVATE LIMITED
Reliable Diesel Engineers Pvt Ltd
Rekha Enterprises
GNG Limited
HITECH ERECTORS PVT. LTD.
POWERSOL INFRA SERVICES PRIVATE LIMITED
SHANTI ENTERPRISES ELECTRICALS PRIVATE LIMITED
Reliable Diesel Engineers Pvt Ltd
GEETU ENGINEERING AND CONSTRUCTIONS PVT LTD
TECHNISYS ENGINEERING PRIVATE LIMITED
Rekha Enterprises
GNG Limited
POWERSOL INFRA SERVICES PRIVATE LIMITED
Shree Tuuljai Electrical Pvt. Ltd
SHANTI ENTERPRISES ELECTRICALS PRIVATE LIMITED
stage.html
html • 0.03 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .