REPAIR/MAINT OF MCBS, DBS, SUBMAIN WIRING AND OTHER CONNECTED WORKS OTM AND ILP AT HISAR MIL STN UNDER GE HISAR
2026_MES_797243_1
GE(H)-41/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Hisar
As per NIT
6 documents required · 6 mandatory
₹500
GE Hisar
₹40,000
Yes
4 Nov 2026
4 Nov 2026
26 Nov 2026
4 Nov 2026
24 Nov 2026
19 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F in replacement sheet metal enclosure distribution board VTPN DB 4 way, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 including incoming and outgoing MCB / MCCB DBs confirming to IS-13032, IS-8632, BS 5484 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut, bolts washers proper with PCC works complete all as specified and as directed by Engineer-in-Charge. Make : Legrand/ C&S/ Indoasian/ Havells/ Hager | 10 | EACH | - | - |
| 2 | S&F in replacement factory made powder coated TPN DB 4 way, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 200 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts and suitable for one DP MCB as incomer and outgoing MCBs as required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed.
Note :- (i) MCBs shall be measured and paid seperately.
(ii) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included in the quoted rates.
Make : Legrand/ C&S/ Indoasian/ Havells/ Hager | 40 | EACH | - | - |
| 3 | S&F in replacement factory made powder coated SPN DB 8 way, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 100 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts and suitable for one DP MCB as incomer and outgoing MCBs as required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed.
Note :- (i) MCBs shall be measured and paid seperately.
(ii) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included in the quoted rates.
Make : Legrand/C&S/Indoasian/Havells/Hager | 80 | EACH | - | - |
| 4 | All as per iterm no 3.00 above but for SPN DB 4 way | 30 | EACH | - | - |
| 5 | All as per iterm no 3.00 above but for SPN DB 12 way | 12 | EACH | - | - |
| 6 | S&F in replacement of 4 pole MCCB 63 Amp, 10KA, 'C' curve,50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed. | 20 | EACH | - | - |
| 7 | S&F in replacement of 4 pole MCCB 100 Amp, 10KA, 'C' curve,50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed. | 14 | EACH | - | - |
| 8 | S&F in replacement of 4 pole MCCB 160 Amp, 10KA, 'C' curve,50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed. | 10 | EACH | - | - |
| 9 | S&F in replacement of 4 pole MCB TPN 63-100 Amp, 10KA, 'C' curve, 50 Hz, 415 Volt with rupturing capacity 16 KA complete all as specified and directed. | 20 | EACH | - | - |
| 10 | S&F in replacement of SPN 16 to 40 Amps, 240 V,10 KV, C-CURVE, 50 Hz AC complete all as specified directed. | 122 | EACH | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
BOQ_894257.xls
BOQ • 0.74 MB
TENDERGE41.pdf
Tender Documents • 1.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .