Tender Value
₹14.3 L
EMD Value
₹28,500
Closing Date
29 Mar 2022, 4:00 pmClosed
DGM ELECTRIC UNIT JKPCC LTD SRINAGAR
DGM ELECTRIC UNIT JKPCC LTD SRINAGAR
Balance Work of Electrification of District Hospital Ganderbal
2022_PWDJK_164359_1
71/DGM/JKPCC/E/K of 2021-22
Open Tender
Electrical Works
Item Rate
60 days
GANDERBAL
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
FC JKPCC LTD A/c
₹28,500
12 Apr 2022
15 Mar 2022
30 Mar 2022
15 Mar 2022
29 Mar 2022
15 Mar 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group C)
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed Pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuits/submains alng with Earth wire with the following sizes of FRLS PVC insulated copper conductor single core cables in surface /recessed medium class PVC conduit as required.
2 X 2.5 sqmm + 1 no.2.5sqmm earth wire
2 x 4 sqmm + 1 no 4sqmm earth wire
2 x 6 sqmm + 1 no.6sqmm earth wire .
2 x 10 sqmm + 1 x 6 sqmm earth wire
2 x 16 sqmm + 1 no.6 sqmm earth wirer .
Suply and installation of integral LED 4ft luminarie with extruded housing & opal diffuser.The luminarie should have a color consistency SDCM < 5,CRI> 80 and CCT of 6500 K.The luminarie shall be compliant with IP 20 classification.Luminarie shall be designed to emitt at least 4400 nominal lumens at a system efficacy of attleast 110 lumens / watt with a maximum wattage of 40 watts.The luminarie shall be designed so as to ensure lumen depriciation of upto 30% over 50K burning hours @ design ambient temp 45deg C. The electronic driver used shall have a power factor > 0.95 and THD < 10% and suitable for an operating voltage range of 140-270 V AC.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics,IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0, 2007 for Electrical safety, IEC62384 ed 1.1, 2011 for perfofmance and IEC 61547 ed 2.0, 2009, CISPR-15 for EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt, of india. LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify. above parameters
Supply,Installation of LED indoor (Surface Downlighter suitable for general lighting. Luminarie should have aluminum die cast housing with polycarbonate coverwith diffused optics.The luminarie should have CRI>80 and CCT of 6500K. The luminarie shall be compilant with IP20 classification. The fixture should have a minimum system efficacy of 100 lumens/watt and a minimum system lumen output of 1200 lumen and a maximum system wattage of 12 watts. The luminarie shall be designed so as to ensure a lumen deprication of upto 30% over 50K burning hours @ design ambieent temp 45deg C. The electronic driver used shall have a power factor>0.95, THD<10%.The fixture should comply with the parameters as per ISI 0322.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics,IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0, 2007 for Electrical safety,IEC62384 ed 1.1, 2011 for perfofmance and IEC 61547 ed 2.0, 2009, CISPR-15 for EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above paramete
Supply,testing and commissioning of Ceiling fans (crompton greaves High Breez or approved equivalent) complete with doublebearig, motorbearing, r, blades, down-rod canopies capacitor two module stepped type electronic fan regulator suitable for operation on 230V 50HZ 1-phase A.C supply complete as required
1400 mm sweep
1200 mm sweep
Supply,testing ,installation& commissioning of 900 RPM 300mm Exhaust Fan suitable for single phase 230v 50HZ AC supply Complete with motor louvers,shutters etc complete as required
Supply and fixing of 6-32Amp SP 240V " C " series miniature circuit breaker ( MCB) suitable for lighting and other loads in the existing MCB DB"s complete with connections, testing & commissioning ets as per technical specifications
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, MCB, having a breaking capacity 10 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supply and laying of following size of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as requried
M/S HIBBA ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .