| 1 | L1₹3.6 CrAccepted-AOC FLAT NO 002 MAHAVIR VILLA CHS LTD PLOT NO 259 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹3.6 Cr Quoted ₹3.7 Cr | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER |
| 2 | L2₹3.8 Cr+₹10.3 L (2.78%)Rejected-Finance | ₹3.8 Cr+₹10.3 L (2.78%) | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| 3 | L3₹3.9 Cr+₹24.4 L (6.62%)Rejected-Finance NOT SPECIFIED | ₹3.9 Cr+₹24.4 L (6.62%) | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| 4 | L4₹3.9 Cr+₹25.8 L (6.99%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | ₹3.9 Cr+₹25.8 L (6.99%) | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| 5 | L5₹4.0 Cr+₹33.1 L (8.98%)Rejected-Finance RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | ₹4.0 Cr+₹33.1 L (8.98%) | L5 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | RAJENDRA CONSTRUCTION L1 | United Sales Corporation L3 | Garima Construction Co L10 | Horizon Construction L6 | Shri Sai Electricals L5 | UNIQUE ENGINEERS L9 | KSP ENTERPRISES L8 | S.R.M.K Enterprises L4 | Sunbud Multiventures Private Limited L2 | SHAILENDRA B TULSANI L11 | SHREE KRISHNA INFRASTRUCTURE L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc of any description all as specified and directed. | 600 | Sqm | 31 ₹18,600 | 10 ₹6,000 | 45 ₹27,000 | 7 ₹4,200 Lowest | 15 ₹9,000 | 65 ₹39,000 | 21 ₹12,600 | 40 ₹24,000 | 35 ₹21,000 | 27 ₹16,200 | 18 ₹10,800 |
| 2.00 | M&L rendering 15 mm thick (10mm + 5mm) plaster on fair face of brick work in CM 1:4 mixed with water proofing compound and finished surfaces even and smooth wothout using extra cement all as specified and directed.
Note : WPC shall be measured & paid seprately. | 375 | Sqm | 310 ₹1,16,250 | 350 ₹1,31,250 | 315 ₹1,18,125 | 250 ₹93,750 | 220 ₹82,500 | 300 ₹1,12,500 | 240 ₹90,000 | 300 ₹1,12,500 | 215 ₹80,625 Lowest | 360 ₹1,35,000 | 225 ₹84,375 |
| 3.00 | M&L for providing water proofing plaster at the junction of wall and slab at chajjas, lintels, etc. of average thickness 20mm in CM 1:3 mixing with liquid water proofing compound all as per manufactureres instructions, finished surfaces even and smooth without using extra cement all as specified and directed.
Note : WPC shall be measured & paid seprately). | 75 | Sqm | 345 ₹25,875 | 500 ₹37,500 | 380 ₹28,500 | 350 ₹26,250 | 300 ₹22,500 | 325 ₹24,375 | 300 ₹22,500 | 350 ₹26,250 | 375 ₹28,125 | 432 ₹32,400 | 270 ₹20,250 Lowest |
| 4.00 | Supply only Liquid water proofing compound all as specified and directed. | 5 | Litre | 251 ₹1,255 | 250 ₹1,250 | 250 ₹1,250 | 200 ₹1,000 | 500 ₹2,500 | 225 ₹1,125 | 66 ₹330 | 50 ₹250 Lowest | 261 ₹1,305 | 180 ₹900 | 63 ₹315 |
| 5.00 | M&L for preperation of newly plastered surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces all as specified and directed. | 150 | Sqm | 91 ₹13,650 Lowest | 125 ₹18,750 | 110 ₹16,500 | 110 ₹16,500 | 150 ₹22,500 | 125 ₹18,750 | 180 ₹27,000 | 120 ₹18,000 | 115 ₹17,250 | 117 ₹17,550 | 171 ₹25,650 |
| 6.00 | M&L for complete removal of existing treatment of old decorated treatment on wall / ceiling / chajja and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces all as specified and directed. | 26,500 | Sqm | 91 ₹24,11,500 | 135 ₹35,77,500 | 140 ₹37,10,000 | 110 ₹29,15,000 | 125 ₹33,12,500 | 135 ₹35,77,500 | 159 ₹42,13,500 | 120 ₹31,80,000 | 85 ₹22,52,500 Lowest | 126 ₹33,39,000 | 153 ₹40,54,500 |
| 7.00 | M&L for making hole for fixing metalic packer for hydrophobic PU foam and sealer as per manufacturers specification. The PU foam shall have 100% solid and solvent free, shall expand 30-40 times its volume at liquid stage in the presence of water, the PU Plan injection shall have minimum 100 CPS viscosity and shore hardness minimum 50 for OHT tank Wall/floor joints all as specified and directed. | 300 | Sqm | 499 ₹1,49,700 | 500 ₹1,50,000 | 480 ₹1,44,000 | 1,200 ₹3,60,000 | 600 ₹1,80,000 | 450 ₹1,35,000 Lowest | 930 ₹2,79,000 | 600 ₹1,80,000 | 500 ₹1,50,000 | 450 ₹1,35,000 Lowest | 900 ₹2,70,000 |
| 8.00 | M&L for 10 mm thick plastering on fair faces of brickwork, or concrete surfaces in CM 1:6 with finishing the surface even and smooth (without using extra cement) all as specified and directed. | 100 | Sqm | 275 ₹27,500 | 275 ₹27,500 | 215 ₹21,500 | 220 ₹22,000 | 200 ₹20,000 | 300 ₹30,000 | 240 ₹24,000 | 250 ₹25,000 | 105 ₹10,500 Lowest | 234 ₹23,400 | 225 ₹22,500 |
| 9.00 | M&L rendering 5mm thick in cement mortar 1:4 on fair faces of concrete surfaces of ceiling, finishing surfaces even and smooth without using extra cement all as specified and directed. | 50 | Sqm | 375 ₹18,750 | 250 ₹12,500 | 160 ₹8,000 | 180 ₹9,000 | 180 ₹9,000 | 280 ₹14,000 | 180 ₹9,000 | 150 ₹7,500 Lowest | 160 ₹8,000 | 198 ₹9,900 | 171 ₹8,550 |
| 10.00 | M&L for applying three coats of white wash to newly plastered surface over one coat of wall care putty of ceiling including preparation all as specified and directed. | 50 | Sqm | 35 ₹1,750 | 25 ₹1,250 Lowest | 80 ₹4,000 | 55 ₹2,750 | 30 ₹1,500 | 85 ₹4,250 | 42 ₹2,100 | 28 ₹1,400 | 120 ₹6,000 | 45 ₹2,250 | 36 ₹1,800 |
Tender Value
₹5.5 Cr
EMD Value
₹6.3 L
Closing Date
24 Oct 2025, 6:00 pmClosed
CWE Khadki Pune
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
SPL REPAIR TO BLDG NO P 53 HOSPITAL WARD BLOCK PHASE II AT MH KHADKI UNDER GE MH AND RH KHADKI
2025_MES_732345_1
CWE/KKE/TOKEN-31 OF 2025-26
Open Tender
Civil Works
Item Rate
365 days
CWE Khadki Pune
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹3,000
GE MH AND RH KHADKI
₹6.3 L
Yes
19 Dec 2025
23 Sept 2025
27 Oct 2025
23 Sept 2025
24 Oct 2025
16 Oct 2025
23 Sept 2025 - 8 Oct 2025
Amount
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc of any description all as specified and directed.
M&L rendering 15 mm thick (10mm + 5mm) plaster on fair face of brick work in CM 1:4 mixed with water proofing compound and finished surfaces even and smooth wothout using extra cement all as specified and directed. Note : WPC shall be measured & paid seprately.
M&L for providing water proofing plaster at the junction of wall and slab at chajjas, lintels, etc. of average thickness 20mm in CM 1:3 mixing with liquid water proofing compound all as per manufactureres instructions, finished surfaces even and smooth without using extra cement all as specified and directed. Note : WPC shall be measured & paid seprately).
Supply only Liquid water proofing compound all as specified and directed.
M&L for preperation of newly plastered surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces all as specified and directed.
M&L for complete removal of existing treatment of old decorated treatment on wall / ceiling / chajja and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces all as specified and directed.
M&L for making hole for fixing metalic packer for hydrophobic PU foam and sealer as per manufacturers specification. The PU foam shall have 100% solid and solvent free, shall expand 30-40 times its volume at liquid stage in the presence of water, the PU Plan injection shall have minimum 100 CPS viscosity and shore hardness minimum 50 for OHT tank Wall/floor joints all as specified and directed.
M&L for 10 mm thick plastering on fair faces of brickwork, or concrete surfaces in CM 1:6 with finishing the surface even and smooth (without using extra cement) all as specified and directed.
M&L rendering 5mm thick in cement mortar 1:4 on fair faces of concrete surfaces of ceiling, finishing surfaces even and smooth without using extra cement all as specified and directed.
M&L for applying three coats of white wash to newly plastered surface over one coat of wall care putty of ceiling including preparation all as specified and directed.
M&L for complete removal of existing internal finishes and applying two coats of Plastic Emulsion Paint over one coat of primer and over 3mm thick wall care putty over plastered surface all as specified and directed.
M&L for preperation of new plastered surfaces and applying two coats of Plastic Emulsion emulsion Paint over one coat of primer and over 3mm thick wall care putty over plastered surfaces all as specified and directed.
M&L for preperation of old surface and applying one coat of oil bound distemper on ceiling all as specified and directed.
M&L for preperation of old surfaces and applying one coat of oil bound distemper on wall all as specified and directed.
M&L for complete removal of existing treatment for preparation of old decorated treatment on wall / ceiling / chajja by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint, etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes, etc. complete and applying two coats of Anti bacterial paint/ PU coated paint (Asian Royal health shield or equivalent) over one coat of acrylic wall care putty of 1 mm thickness over one coat of royal wall base coat) for Operation Theatre and ICU ward all as specified and as directed.
M&L for preparation of old painted surfaces of steel and iron of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding complete and removing rubbish off the premises all as specified and directed.
Demolition of cement concrete unreinforced of any description and in any position, not otherwise specifically provided for as in sunken floors and similar of locations complete all as specified and directed.
M&L PCC (1:5:10) type E-2, (using 40mm graded crushed stone aggregate) as in mass concrete or as in sunken floor all as specified & directed
Taking up or down steel tubes of 15 mm bore and connections, including cleaning for re-fixing or removal to store all as specified and directed.
Taking up or down steel tubes 20 mm bore and connections, including cleaning for re-fixing or removal to store all as specified and directed.
S&F steel tubes of size 15mm bore (medium grade) galvanised with all fittings and fixed complete to wall all as specified and directed.
S&F steel tubes of size 20 mm bore (medium grade) galvanised with all fittings and fixed complete to wall all as specified and directed.
Re-fixing old steel tubes of size 15mm bore (medium grade) galvanised with all fittings and fixed complete all as specified and directed.
Re-fixing old steel tubes of size 20 mm bore (medium grade) galvanised with all fittings and fixed complete to wall all as specified and directed.
M&L coloured ceramic tiles in vertical surface 300x450mmx7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles laid over and including 10 mm thick backing coat in CM 1:4 all as specified and directed.
M&L non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm in floor, etc. set and jointed in neat cement slurry to match the work using colour tiles and including 15mm thick screed bed in C.M 1:6 all as specified and directed.
M&L for applying 20-40 mm in width polyurethane sealant (Silane -terminated polyurethane compound) (Make:Asian smart care hybrid Pu sealant /Dr fixit PU sealant or equivalent) for sealing of dynamic joints and cracks in interior as well as exteriors of Expansion joints/construction joints and other cracks all as specified and directed.
S&F 45mm dia Closed-cell polymer-based foam filler rod (supreme Dura rod or equivalent) in construction/Expansion joints whereverrequired and patching the joint all as specified and directed.
S&F 20-40 mm thick Cross linked, pre-moulded, compressible joint filler board like Supreme "DURA BOARD HD 100"or equivalent ) in expansion joints wherever required and patching the joint all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern in crumple joints all as specified and directed.
S&F 0.63mm thick, plain galvanised mild steel sheet (white colour) as in repairs in crumple joints and straight flashings (length and girth as fixed) with grade of zinc coating 275 in crumble/expansion joint and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to RCC wall framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required all as specified and directed.
S&F in repairs vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonage pipe and making good to floor to match with the existing all as specified and directed.
S&F in repairs vitreous China wash down full stall urinal white size (460x380x970mm) (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap and flushing pipe, anti syphonage pipe and making good to floor to match with the existing all as specified and directed.
S&F in repairs CP wall mixer 3 in 1 system with provision for both hand shower and overhead shower complete with 115mm long bend pipe connecting legs & wall flange screwed down for iron pipe all as specified and directed.
Dismantling wrought iron or mild steel or stainless steel work of any description not otherwise provided for stainless steel railing all as specified and directed.
M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of floor other side of waist slab with suitable arrangement including holes drilled any dia and depth as required all as specified and directed.
S&F in repairs PVC low level flushing cistern, 10 Ltr capacity, with flush pipe all as specified and directed
Supply only PVC seat and cover for pedastal pattern all as specified and directed.
S&F in repairs stop valves cast copper alloy CP screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15 mm dia all as specified and directed.
S&F in repairs two way bib tap 15mm chromium plated all as specified and directed.
S&F in repairs Fancy type bib taps chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm dia all as specified and directed.
S&F in repairs Concussive push button taps of cast copper alloy, screwed for iron pipe or for brass ferrule 15mm dia all as specified and directed.
S&F 75mm dia PVC (SWR) multi floor trap with grating including jointing with solvent cement all as specified and directed.
S&F in repairs wash hand basin vitreous china white flat back of size 550 x 400 mm including PVC flexible waste pipe 32 mm bore 600mm long PVC connection pipe, chromium plated brass waste fittings 32 mm including 15 mm bore chromium plated pillar taps fancy type chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered Hot Or Cold Withlong screwed shanks and fly nuts screwed for iron pipes all as specified and directed.
S&F in repairs counter top viterious china wash basin white flat back size 550 x 400 mm excluding taps waste chain and plug and porcelain stopper but including necessary brackets CP wastes and other fittings all as specified and directed.
S&F in repairs single lever tall pillar taps for counter top wash basin, chromium plated, cast copper alloy with capstan heads, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipes 15mm dia all as specified and directed
S&F in repairs 32mm dia chromium plated Bottle trap having minimum water seal of 25mm (Minimum weight 175-450grams) all as specified and directed.
S&F in repairs 32mm dia waste coupling of PTMT (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) all as specified and directed.
S&F 32 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 Kgf/cm2 including making thread for fixing with waste coupling all as specified and directed.
S&F in repairs PTMT towel rail 600mm long fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 190 gms) all as specified and directed.
S&F in repairs 32mm dia, PVC flexible waste pipe for WHB/Sink etc complete all as specified and directed.
S&F PVC connections 15mm size with brass nut on both end, washers of length 600mm all as specified and directed.
M&L for cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise not exc 100 sqcm all as specified and directed.
M&L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise exc 100 sq.cm but n.exc 250 sq.cm all as specified and directed
Taking down drain pipes (of any size or pattern), including all fittings, Tee, bends, etc including cleaning or refixing (measured overall as fixed along the centre line over fitting and accessories) all as specified and directed.
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floor all as specified and directed.
S&F PVC (SWR) pipes 75 mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floor all as specified and directed.
S&F PVC (SWR) 110mm dia bends any radius all as specified and directed.
S&F PVC (SWR) branch 110mm bore pieces, single ( single Y ) equal or unequal all as specified and directed.
S&F PVC (SWR) junction 110mm bore single ( single Tee) equal or unequal all as specified and directed
S&F PVC (SWR) 75 mm dia bends any radius all as specified and directed.
S&F PVC (SWR) junction 75 mm bore single ( single Tee) equal or unequal all as specified and directed.
S&F PVC (SWR) branch 75 mm bore pieces, single (single Y) equal or unequal all as specified and directed.
S&F PVC (SWR) 110mm bore vent cowl all as specified and directed.
S&F PVC (SWR) 75mm bore vent cowl complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar all as specified and directed.
M&L for fly ash brick work old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frame) area not exc 1.5 sqm each all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube all as specified and directed.
S&F factory made PVC solid panel door shutter 30mm thick (style) connecting of frame made out of MS tube for top and bottom rail MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strips of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail of either side and as gap insert for top rail and bottom rail panelling of plain colour PVC to be fitted in the MS frame welded/ sealed in the stiles and rail with suitable PVC sheet and loading and jointed together with solvent cement, supplying and fixing in the frame at site complete all as specified and directed.
S&F 125 mm size extruded aluminium alloy handles, fabricated type anodised all as specified and directed.
S&F aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt 125mm all as specified and directed.
S&F 75 mm mild steel butt hinges medium weight, cold rolled all as specified and directed.
S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing all as specified and directed.
S&F powder coated aluminium section (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws all as specified and directed. Note- (i) Glass panes and wire net will be measured and paid separetly. (ii) The quoted rate shall be inclusive of cost of rubber beading and glazing clip hinges, handle however it will not be weighted and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate. iv) Windows all around will be sealed with silicon sealant.
Supply only 3mm thick sheet glass, ordinary quality and in glazing exc 0.5sqm in each pane all as specified and directed.
M&L 9 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, aluminium works all as specified and directed.
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples and nut bolt, fixed complete all as specified and directed.
S&F in repairs double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
M&L for vitrified ceramic tiles (matt finishes) 10mm thick colour/ dark shade (square/ rectangular) area of each tile not exc 0.36 sqm each in flooring set and jointed in neat cement slurry and pointed with white or coloured cement to match with the shade of tiles laid over 20mm thick screed bed in CM 1:4 all as specified and directed.
M&L coloured ceramic tiles on vertical surface/skirting/dado of size 300x450mmx7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles and laid over 10mm thick backing coat in CM 1:4 all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, laid, bedded and jointed in cement mortar all as specified and directed.
M&L for granite slab (of any type/colour) 20mm thick machine cut, laid over and laid over 20mm thick screed bed in cement mortar 1:4, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigments to match with the shades of granite stone as in platforms/counter platform tops including cutting and mirror polishing etc complete all as specified and directed,
M&L machine cut kota stone slab flooring 20-25mm thick in flooring but one piece as in treads of straircase laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing moulding complete, laid over 15 mm thick screed bed or bedding in CM 1:6 for laying floor finishes all as specified and directed.
All as item No 87 here-in-before but in one piece on vertical surface as in skirting/dado over backing coat 10mm thick CM 1:4 to receive kota stone/slab etc complete all as specified and directed.
M&L for 20mm thick machine cut Cudappah stone slab laid over 15mm thick screed bed in CM 1:6 in any position all as specified and directed.
M&L Mirror polishing to old existing kota stone flooring including necessary cutting, grinding, joints pigment filling and polishing to get mirror finish all as specified and directed.
M&L for grinding, rounding of edges of stone slabs as in steps of stairs, counter top platform and other similar items all as specified and directed.
Dismantling wall and ceilihg boards (Fiber pulp, insulation etc or insulation boards) any thickness including cover fillets all as specified and directed.
M&L for providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions over and including Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre all as specified and directed.
Taking down carefully old copper/Aluminium point wiring, fitting and fixtures complete such as switches, ceiling rose, pendenent, regulators, sockets, etc. removing unserviceable materials from site and making good disturbed surface to match with the existing all as specified and directed.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes all as specified and directed.
Taking down the existing unserviceable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down old unsv tube light fitting/ Recess Mounted fitting/ Down lighter or ceiling mounted fitting of any type and from any height all as specified and directed.
M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits), with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including medium grade PVC conduit minimum 20 mm dia concealed in wall/floor/ceilling and accessories etc, ISI marked with mild steel/pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with modular white cover plate with frame for mounting modular switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly One light controlled by one switch 6 Amp one way all as specified and directed by Engr-in- charge.
All as per item No 98 here-in-before but for One fan point controlled by one switch 5 Amp one way
All as per item No 98 here-in-before but for One socket outlet 3 pin 5 amps same board
All as per item No 98 here-in-before but for One socket outlet 3 pin 5 amps on Independent board
All as per item No 98 here-in-before but for for one socket outlet 15 Amps fixed on independent board with 2.5 Sq mm multistranded copper conductor wire FRLS PVC insulated and 2.5 Sq mm copper conductor wire FRLS PVC insulated using as earth wire all as specified and directed by Engineer-in-Charge
S&F modular type 1 way 6 Amp 240 volts AC all as specified and directed.
S&F socket, 6 A - 2/3 pin combined 2 modue all as specified and directed.
S&F in repairs socket outlet 2 in 1, 3 pin, 6 and 16 Amps flush type inreplacement all as specified and directed.
S&F in repairs modular switch 1 Way 16 A, 1 module all as specified and directed
S&F in repairs stepped type modular fan regulator, capacity 120 w - 2 module suitable for 1200/1400 mm ceiling fan all as specified and directed.
S&F Modular bell push 6 Amps all as specified and directed
S&F in repairs Single pole and neutral enclosure with a metal two pin and earth plug and metal clad socket complete with one single pole MCB 20 Amps all as specified and directed
S&F ceiling rose 65x50 mm three terminal 230 volt, 50Hz AC Supply all as specified and directed
S&F in repair MCB DBs sheet metal enclosure single pole and neutral 240 Volt with 200 Amps rated copper bus bar 12 way double door type all as specified and directed
S&F in repairs MCB DBs sheet metal enclosure single pole and neutral 240 Volt with 200 Amps rated copper bus bar 8 way double door type all as specified and directed
S&F in repairs MCB DBs sheet metal enclosure single pole and neutral 240 Volt with 200 Amps rated copper bus bar 4 way double door type all as specified and directed
S&F in repairs MCB DBs sheet metal enclosure TPN 6 way 415 Volt with 200 Amps rated copper bus bar double door type all as specified and directed
S&F in repairs MCB DBs sheet metal enclosure TPN 4 way 415 Volt with 200 Amps rated copper bus bar double door type all as specified and directed
S&F MCB's TPN 40 TO 100 Amps, 240 Volts,10 KA rapturing capacity 'C' curve all as specified and directed Make : Legrand ,C&S,Indo Asian
S&F MCB SP 6 to 32 amps, C curve 10kA all as specified and directed Make : Legrand ,C&S,Indo Asian
S&F MCB SPN 32 Amps 10kA C curve all as specified and directed Make : Legrand ,C&S,Indo Asian
S&F MCB SPN 40 to 63 Amps all as specified and directed Make : Legrand ,C&S,Indo Asian
Supply and fixing TPN range 16 To 32 AMP 10 kA 'C' curve all as specified and directed Make : Legrand ,C&S,Indo Asian
Taking down carefully electric geysers of any make, type and capacity after disconnecting of electrical and water connections, opening of bottom cover, checking of all parts and taking out copper/ Stainless steel tank, checking of its leakage and removing the dust, brazing the leakage and painting of geysers with two coats of synthetic enamel painting replacement of worn out spares and reassembling complete geyser and re-fixing back its position including proper electrical connection all as specified and directed
S&F in repairs metal braided CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 CM long for hot water connection all as specified and directed.
S&F in repairs metal braided CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 CM long for cold water connection all as specified and directed.
Taking down and Refixing carefully ceiling fan of any make, size from its location, dismantling complete fan, examine complete parts thoroughly, servicing, oiling, greasing of all parts and complete overhauling of fan including checking of winding, replacement of small parts such as split pin, nut bolt, screw and assembling complete fan and make fully functional and refixing the fan to its original position including replacement of three core PVC insulated multi strandard copper wire 0.5 sq mm 1100 Volts grade from fan connector to ceiling rose all as specified and directed
Taking down and Refixing carefully Exhaust fan of any make, size from its location, dismantling complete fan, examine complete parts thoroughly, servicing oiling, greasing and Painting all parts and complete overhauling of fan including checking of winding, replacement of small parts such as split pin, nut bolt, screw and assembling complete fan and make fully functional and refixing the fan to its original position including replacement of three core PVC insulated multi strandard copper wire 0.5 sq mm 1100 Volts grade from fan connector to ceiling rose all as specified and directed
S&F in repairs wall mounted LED light fitting inverter type extruded Polycarbonate/aluminium housing high quality indoor batten LED tube 20 watt colour temperature 4000 K (4' long) lumen 1700-2000, PF> 0.90, THD less 10% diffused connecting with three core flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-charge. Note:- Indoor LED batten inverter tubelight 4' long will be fixed on two pvc square boxes properly.
S&F in repairs surface cum recessed mounted down light with white powder coated polycarbonate housing and PC diffuser in white powder coated finish with built in electronic driver. PC diffuser in white powder coated finish with integral electronic of capacity 12 W with 6500K PF>/= 0.90 LED THD<20% light fitting as per site requirement all as specified and directed. Make : Havells equivalent in Wipro/ Philips/Crompton
S&F in repairs recess mounted LED fitting 600 mm X 600 mm in size and 36W range, with powder coated CRCA housing and polycarbonate diffuser, LED Fixture system wattage 36W, 140V -260 V AC, System lumen out put min 3600 lumen in 36 w with 5700-6500 K, CCT with PF>0.95 CRI>=80 and with <=10 % THD, with Min 2.5 KV surge protection in built complete LED fixture all as specified and directed by Engr-in-Charge. Make : Havells equivalent in Wipro/ Philips/Crompton
M&L for submain wiring with replacement with approved colour code/as per IS (Red, black & green for single phase) with Four single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in PVC concealed conduit minimum 25 mm dia including two run of PVC insulated multistranded copper conductor nominal cross sectional area of 6.00 Sqmm (FRLS) of contineous earth wire green in colour all as specified and directed. Note :- Four runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable green colour with one run of PVC concealed conduit shall be paid as one unit length)
M&L for submain wiring with replacement with approved colour code/as per IS (Red, black & green for single phase) circuit with Two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 4.00 Sqmm (FRLS) in PVC concealed conduit including one run of PVC insulated multistranded copper conductor nominal cross sectional area of 4.00 Sqmm (FRLS) of contineous earth all as specified and directed. Note :- Two runs of 4.00 Sqmm cable & one run of 4.00 Sqmm cable green colour with one run of PVC concealed conduit shall be paid as one unit length.
M&L for submain wiring with replacement with approved colour code/as per IS (Red, black & green for single phase) circuit with Two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) in PVC concealed conduit including one run of PVC insulated multistranded copper conductor nominal cross sectional area of 10 Sqmm (FRLS) of contineous earth wire green in colour all as specified and directed. Note :- Two runs of 10.00 Sqmm cable & one run of 10 Sqmm cable as earth cable with one run of PVC concealed conduit shall be paid as one unit length)
M&L in repairs GI earthing complete with Galvanised earth plate 600mm x 600mm x 3 mm thick burried directly in ground (earth pit not less than 3.25 mtr below normal ground level ) with top edge of the plate not less than 3.25 mtr deep below normal ground level and connected to GI wire of 4 mm dia by means of bolts check nuts and washers of brass/ bronge all as shown in electrical plate no 3, connecting to earthing test point all as specified and indicated and testing on completion including excavation earth work drilling holes for electrode PCC pit in PCC 1:2:4 type B1 (using 20mm graded stone aggregate), RCC precast cover 1:2:4 type B1 (using 20mm graded stone aggregate), GI pipe 15 mm dia (medium grade) and MS funnel, wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal in black cotton soil as required at site to achieve the earthing result and common salt, excavation & earth work,etc. in any type of starta complete all as per the sketch given in particular specification, GI wire suitable size and length for continuity earth wire from test point to main distribution Board all as specified and directed. Note:- Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length. All the joints shall be made with welding to get proper conductivity. Rate required deemed to be inclusive of excavation & earthwork by compressor machine or breaker for soft /disintegrated rock to the required depth and results of earthing should be below 1 Ohm all as specified and directed.
Sunbud Multiventures Private Limited (BID ID -3457829)
United Sales Corporation (BID ID -3455794)
S.R.M.K Enterprises (BID ID -3458719)
Shri Sai Electricals (BID ID -3458119)
Horizon Construction (BID ID -3457620)
SHREE KRISHNA INFRASTRUCTURE (BID ID -3458230)
KSP ENTERPRISES (BID ID -3458470)
UNIQUE ENGINEERS (BID ID -3458433)
Garima Construction Co (BID ID -3456668)
SHAILENDRA B TULSANI (BID ID -3458687)
Bidder Name
SHAILENDRA B TULSANI
United Sales Corporation
Garima Construction Co
KSP ENTERPRISES
Shri Sai Electricals
RAJENDRA CONSTRUCTION
UNIQUE ENGINEERS
S.R.M.K Enterprises
SHREE KRISHNA INFRASTRUCTURE
Horizon Construction
Sunbud Multiventures Private Limited
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.31 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_819968.xls
BOQ • 3.54 MB
Tender Documents
Tender Documents • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .