Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹47.6 L
EMD Value
₹95,120
Closing Date
4 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
LT COL MANISH E WASNIK
GE (CENTRAL) DELHI CANTT-10
PROVN OF CERTAIN SANCTION WK IN THE AREA OF AGE B/R-I UNDER GE (CENTRAL) DELHI CANTT-10
2026_MES_798552_1
GE/TOKEN-133/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹95,120
Yes
13 Nov 2026
13 Nov 2026
7 Dec 2026
13 Nov 2026
4 Dec 2026
27 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting existing 500/1000 ltr tanks, setting a side (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including all necessary fitting and fixtures complete all as specified and directed. | 12 | Each | 100 | ₹1,200 |
| 2 | Supply and fixing in repair three layers 500 litre HDPE water storage tanks polyproof. white in colour rotational moulded polyethylene (cylindrical vertical with closed top) hoisted and fixed in position including Supply and fixing of suitable size inlet/outlet arrangement & other accessories complete all as specified and directed. | 8 | Each | - | - |
| 3 | Supply and fixing in repair three layers 1000 litre HDPE water storage tanks polyproof. white in colour rotational moulded polyethylene (cylindrical vertical with closed top) hoisted and fixed in position including Supply and fixing of suitable size inlet/outlet arrangement & other accessories complete all as specified and directed. | 6 | Each | - | - |
| 4 | Demolition Bricks (laid flat or on edge) or brick tiles in floors, roof, channels, kerbs, aprons, etc. (each layer all as specified and directed. | 2,200 | Sqm | - | - |
| 5 | Demolition Mud in roofs, any thickness, including plastering and lapping (whether full thickness removed or only a part thereof) all as specified and directed. | 550 | Cum | - | - |
| 6 | Removing soil excavated material exc. 1.5Km but n exc 5km and depositing where directed at above the starting point all as specified and directed. | 550 | Cum | - | - |
| 7 | M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone aggregate) on roof padding surface finished even and smooth without using extra cement complete all as spd & directed. | 132 | Cum | - | - |
| 8 | M&L providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalent also taking down cement plaster on brick/concrete surfaces, parapet wall including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, all as specified and as directed. Make: Asian Paints or equivalent in Sikka, Fosroc and STP Ltd.
Note: The application shall be executed on any type of surface and on horizontal/Vertical areas as per directed by Engr - in - Charge. | 2,480 | Sqm | - | - |
| 9 | M&L providing and applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary [coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile/fibre, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge.
Make: SmartCare Damp Proof of Asian Paints or equivalent in Berger/ Nerolac/Nausar STP Ltd.
Notes: (1) The work shall be executed through authorised applicator of manufacturer only.
(2) Authrised Applicator shall be approved by GE before starting of work.
(3) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material.
Engineer-in-Charge shall deface the original purchase vouchers.
(4) Guarantee: The contractor shall furnish a written guarantee for the effectiveness of the water proofing treatment for a period of ten years in favour of the GE. A sum equivalent to 2.5% (Two point Five Percent) of the cost of water proofing treatment shall be retained by the Govt from the contractor's dues as security deposit. The contractor may, however, furnish a fixed deposit receipt in lieu from a Schedule bank pledged in favour of Garrison Engineer. | 2,480 | Sqm | - | - |
| 10 | Supply and fixing ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of size 20mm bore ( weight 210 gms Minimum) complete all as specified and as directed. | 14 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
BOQ_895832.xls
BOQ • 0.32 MB
tenderpage.pdf
Tender Documents • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .