| 1 | L1₹79.9 LAccepted-Finance A 3 338 SECTOR 8 ROHINI DELHI 110085 | NORTH WEST | DELHI | 110085 | L1 | Accepted-Finance L1 | |
| 2 | L2₹90.9 L+₹10.9 L (13.6%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹72.7 L
EMD Value
₹1.5 L
Closing Date
9 Mar 2026, 5:00 pmClosed
EXECUTIVE ENGINEER, DIVN V, BICHOILM.
O/O EXECUTIVE ENGINEER, DIVN V, BICHOLIM.
Tender for the Work of APS to the Chief Office, Valpoi Municipal Council, at material recovery Facility at Garbage Treatment Plant Valpoi, Sattari Goa in the jurisdiction of S.O Valpoi Sub-Division-III Valpoi Goa.
2026_ED_27932_1
Tender-90/Div-V (2025-26)
Open Tender
Electrical Works
Percentage
90 days
VALPOI
AS PER NIT
2 documents required · 2 mandatory
₹1,000
₹1.5 L
11 Mar 2026
26 Feb 2026
10 Mar 2026
27 Feb 2026
9 Mar 2026
2 Mar 2026
Cost of Material
GI nuts and bolts
HDGI stay clamps for RCC Pole 11 m L.A
G.I. Turn Buckle with eye bolt 11 KV
G.I. stay wire 7/10 SWG
G.I. Stay rod & plate LT/11KV line
11 KV Disc insulator 45 KN with Metal Parts 3 Bolted type
11 KV Pin insulator with HDGI pins
11KV 'V' Shape X-arm
HT/LT Top Fitting
SETC of 70 sq.mm Single core COVERED Conductor
Enamelled danger boards 11000 Volts as per drg no. CEE/E-490
Anti climbing device ( HDGI Barbed wire 1 kg) alongwith suitable two stay clamps & two pairs of H.D.G.I nuts bolts as per drg No. CEE/E-478
Cement Concrete 1:2:4
Earthing complete with 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr as per drg. No.CEE/E-830.
HDGI structure material for DP
11 KV, 200 A Horn gap fuse unit (Set of three)
Lightning arrestor 9 KV, 5 KA
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6
200 KVA, 11/0.44 KV 3 ph outdoor type, oil immeresed Aluminium wound Level II distribution transformer.
XLPE single Core unarmoured XLPE 300 Sq.mm 1.1KV grade
Aluminium Lug Hole Type 300 sq.mm
Distribution Transformer Metering Unit with AMR Modem
ACSR conductor 'WEASEL' Conductor
Supply & Laying of GI Pipe 150mm, class B (As Risers) (3*6m)
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed) (one per every 100m for entire route length)
Supply and laying 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable (by HDD method)
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit outdoor 3 core 300 sqmm XLPE
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit indoor 3 core 300 sqmm XLPE
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB(with Aux PT) Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
Supply & Erection of HDGI flat of size 25mm x 5mm for earthing.
Supply and laying 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable (RMU to DTC : Distance considered as 10m per every DTC tapping plus 10m raiser) = 20m per DTC
11KV 3 phase outdoor terminating kit to be used with cables - 95 sq.mm.
11KV 3 phase indoor terminating kit to be used with cables - 95 sq.mm.
Supply and Laying of Underground Cable protective cover as per specification as given below: The concrete slab should be machine made using semi-dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-Press" machine with a high vibration frequency and a hydraulic pressure of 40 MT. The size of the slab shall be 480mm x 250mm x 50mm (+- 2mm) and the concrete grade shall be M30 adhering to IS 456 : 2000 and shall have a minimum crushing strength of 30N/mm2 (28 days strength) when tested. Calculation: (20/0.48)
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. Sand (0.2*0.4*20m)- Cable (0.03cubics*20)
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed) (one per every 100m for entire route length)
Supply & Erection of Warning tape.
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All types of Ordinary rock including all types of laterite rock, blasting prohibited
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: All works upto plinth level
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) All works upto plinth level
Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
Centering & shuttering including Strutting, Propping & removal of forms for:Foundations, Footings, Bases for columns
12mm cement plaster 1:4 (1 cement : 4 fine sand)
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
CARRIAGE OF MATERIALS (B) By mechanical transport including loading, unloading and stacking (A) Lime, building rubbish, manure sludge, moorum excavated rock (ii) Earth (upto 5km)
Cost of Erection
RCC Pole 11 mts long
GI nuts and bolts
HDGI stay clamps for RCC Pole 11 m L.A
G.I. Turn Buckle with eye bolt 11 KV
G.I. stay wire 7/10 SWG
Break insulators 8 KV (44KN)
G.I. Stay rod & plate LT/11KV line
11 KV Disc insulator 45 KN with Metal Parts 3 Bolted type
11 KV Pin insulator with HDGI pins
11KV 'V' Shape X-arm
HT/LT Top Fitting
SETC of 70 sq.mm Single core COVERED Conductor
Enamelled danger boards 11000 Volts as per drg no. CEE/E-490
Anti climbing device ( HDGI Barbed wire 1 kg) alongwith suitable two stay clamps & two pairs of H.D.G.I nuts bolts as per drg No. CEE/E-478
Earthing complete with 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr as per drg. No.CEE/E-830.
HDGI structure material for DP
G.O.A.B. switch 11 KV 200 A
11 KV, 200 A Horn gap fuse unit (Set of three)
Lightning arrestor 9 KV, 5 KA
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6
MS Distribution box(M.S) with MCCB 400A & Kit-Kat fuses.
200 KVA, 11/0.44 KV 3 ph outdoor type, oil immeresed Aluminium wound Level II distribution transformer.
XLPE single Core unarmoured XLPE 300 Sq.mm 1.1KV grade
Aluminium Lug Hole Type 300 sq.mm
Distribution Transformer Metering Unit with AMR Modem
ACSR conductor 'WEASEL' Conductor
Supply & Laying of GI Pipe 150mm, class B (As Risers) (3*6m)
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed) (one per every 100m for entire route length)
Laying of 11kV/LT UG cable by trenchless technology by adopting horizontal directional drilling (HDD Method). The work includes preparation of site, Boring as well as drawing of cable in Hard/Laterite Stone with minimum 8'' bore size, including supply and erection of HDPE Pipe 110mm PN6, PE80, Wall Thickness 6mm (minimum) as per IS 4984:1995 amendment 2016. The depth shall be 1.650m to 1.850m (1650mm-1850mm) only except at entry and exit pits where minimum depth shall be 1200mm
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit outdoor 3 core 300 sqmm XLPE
Supply, Erection, Testing & Commissioning of of 11 KV Termination kit indoor 3 core 300 sqmm XLPE
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB(with Aux PT) Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
Supply & Erection of HDGI flat of size 25mm x 5mm for earthing.
Supply and laying 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable (RMU to DTC : Distance considered as 10m per every DTC tapping plus 10m raiser) = 20m per DTC
11KV 3 phase outdoor terminating kit to be used with cables - 95 sq.mm.
11KV 3 phase indoor terminating kit to be used with cables - 95 sq.mm.
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : b) All types of Ordinary rock including all types of laterite rock, blasting prohibited (1.1*0.4*20m)
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. Deduct for RCC Slab (0.9*0.4*20m) - (0.6*0.25*0.05*No. of Prot. covers 42)
Supply and Laying of Underground Cable protective cover as per specification as given below: The concrete slab should be machine made using semi-dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-Press" machine with a high vibration frequency and a hydraulic pressure of 40 MT. The size of the slab shall be 480mm x 250mm x 50mm (+- 2mm) and the concrete grade shall be M30 adhering to IS 456 : 2000 and shall have a minimum crushing strength of 30N/mm2 (28 days strength) when tested. Calculation: (20/0.48)
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed) (one per every 100m for entire route length)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 24.63 MB
BOQ_28377.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .