| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC SANTIPUR HILL SIDE PS BHARALUMUKH GUWAHATI 781 009 | KAMRUP METRO | ASSAM | 781009 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.8 L+₹5.3 L (12.4%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹50.0 L+₹7.5 L (17.6%)Rejected-Finance 0 BINOVA NAGAR KAMRUP ASSAM 781018 UDYAM AS 03 0029196 | KAMRUP METRO | ASSAM | 781018 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹50.0 L+₹7.5 L (17.6%)Rejected-Finance MOHANPUR PT LL HOUSE NO 00 CITY TOWN SILCHAR P O KATIRAIL P S KATIGORAH DISTRICT CACHAR PIN 788804 | CACHAR | ASSAM | 788804 | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹49.9 L
EMD Value
₹99,700
Closing Date
15 Aug 2022, 6:00 pmClosed
GE Narangi
GE Narangi C/o 99 APO
PROVN OF LED BLDG SECURITY LIGHTS IN MD ACCN PHASE II AREA PROVN EXHAUST FAN IN KEY PERSON QUARTER PROVN OF SMART METERS IN OFFCRS ACCN PROVN OF GEYSERS IN JCO OR MD ACCN UNDER GE NARANGI
2022_MES_531245_2
8758/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE Narangi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Narangi
₹99,700
Yes
14 Sept 2022
23 Jul 2022
18 Aug 2022
23 Jul 2022
15 Aug 2022
1 Aug 2022
Amount
SCHEDULE 'A' PART-I
M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC gray conduit of 20mm dia on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by two number two way 5 Amp switch complete all as specified and as directed.
S&F switch piano, flush type single pole one way 5 Amps 230 volt complete all as directed.
S&F switch piano, flush type single pole two way 5 Amps 230 volt complete all as directed.
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as directed.
S&F switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp PVC type complete all as directed. .
S &F street light fitting of 60 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 KV complete also tested for 440 Volt for 8 hour Phase to phase without any damage including taking down old light fittings complete all as specified and as directed. (Make: Havells Cat Part No. ENDURAPEARLNEOSL60WLED757PASYTOPCor equivalent in Philips/Bajaj/Crompton )
Supply and fixing in repairs street light bracket made of GI pipe 40 mm bore light grade (bend to shape), 2.0 metre long and fixed with and including 2 sets of MS flat iron clamp (clamp shall be 40 X 5mm ), nuts, bolts and washers on pole complete all as specified and directed.
S&F MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
S&F of Exhaust fans AC single phase 230/ 240 V ,50 Hz metallic heavy body of size 300 mm sweep, 1400 RPM with louver fixing with 4 no hold fastener nut and bolt with washer and connecting with flexiable PVC insulated multistranded copper conductor cable of size 1.5 sqmm including civil work opening on wall and making good surface complete all as specified and directed. (Make-USHA / Havells/Bajaj /Crompton)
S&F Smart three phase four wire single source prepaid energy meters BIS 15884 marked in existing meter board/floor panels with pre payment capacity touch keypad based digitial having current range 10-60 Amp 415 Volt accuracy class 1.0 alongwith parallel home unit with inbuilt load control switch containing display split provision for TOD and RTC, inbuilt feature to sense single source registration with respect to grid and dynamic load allocation facility from grid capable to define for tariff slabs, happy hours and holiday definition complete all as specified and directed. Make-L&T/HPL or equivalent Note-Unit rate quoted by the contractor is deemed to be impesive of fees for 05 (Five) years server maintenance. The distance between home unit and meter will be approx 20 to 30 meter.
Fixing only old serviceable meter with necessary connection to the different location as directed by the Engg-In-Charge complete. (Note: Old Serviceable Meter obtained from item No. 11 here-in-above.)
M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.)
M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.)
M&L for Sub main wiring with 2 runs of 2.5 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 2.5 Sqmm cable and 1 run of 2.5 Sqmm cable along with conduit altogether shall be measured as one unit.)
S&F of Meter Box, anticorrosive, dust & vermin proof, shock proof, self extingushing property, heat resistant, water proof Ultra Violet Stabilized and pilfer resistant to accommodate 4 Nos three phase pre-paid meter, made out of Thermosetting Plastic ie Glass Reinforced Polyester Steet Moulding Compound (SMC) confirming to IS: 13947 (1992) and IS: 14722:2000 etc. including taking down the old one complete all as specified and as directed.
Supply and fixing in repairs modular north west outlet tiny trip C-25, 2 pole MCB 240 V 50Hz single phase motor startar current range from 11 Amp to 18 Amp 240V 50 Hz AC including top complete all as specified and directed.
Supply, fixing and testing of vertical wall mounted Storage type electric water heater of capacity 25 ltrs with BEE 5 star rated, 230 V, maximum power consumption 2 KW, Drypowder Fero Glass coating Technology for inner container with Heavy Duty seamless Incoloy 800 Glass lined heating element, and 2 Nos PVC connecting pipe of whirl technology 15 mm bore 450mm long for hot and cold water supply complete with all accesories and all as specified and directed by the Engr-In-Charge. (Make: Jaquar Model: MET-WHT-V025 / HAVELLS Model: Puro, or equivalent Model in USHA ).
S & F GI tubing15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Cutting existing steel tubing 15mm dia for addition / insertion of new Tee / Elbows / Socket etc. (Each cut measured) by screwing existing pipe line complete all as specified and as directed.
S&F of Bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair, 15mm dia stop valves stop cast copper alloy, fancy type, chromium plated with long shank and cup ( concealed type) complete all as specified and as directed.
PURBANCHAL BUILDERS
KAMAKHYA CONSTRUCTION & BUILDERS
M/S Bharat Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .