Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Aug 2020, 2:00 pmClosed
Ex Engg STD Bijbehara
Hamzapora Bijbehara
Stage Contract for maintenance of 33/11 KV Receiving stations falling under the jurisdiction of Sub Transmission Division Bijbehara, for the Year 2020-21
2020_PDD_101602_1
Retender Notice STB/13 of 2020-21 Dated 31-07-2020
Open Tender
Electrical Works
Turn-key
1 days
Anantnag/Kulgam
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Treasury Challan Paid to Power
₹50,000
Yes
14 Aug 2020
31 Jul 2020
14 Aug 2020
31 Jul 2020
13 Aug 2020
4 Aug 2020
31 Jul 2020 - 4 Aug 2020
Amount
Dismantalling of Switchgear System of 33 KV C&R Panel
Dismantalling of Switchgear System of 33 KV VCB Panel
Dismantalling of Switchgear System of 11KV VCB Panel
Fixing,installing,testing and commissioning of Switchgear System complete job( including relay testing) of 33 KV C&R Panel
Fixing,installing,testing and commissioning of Switchgear System complete job( including relay testing) of 33KV VCB breaker
Fixing,installing,testing and commissioning of Switchgear System complete job( including relay testing) of 11KV VCB Panel
Fixing,installation, testing & commissioning,testing of fresh Numerical/Digital/electromagnetic Relays by way of Replacement of Damaged/Burnt already installed in panel.(including fabrication of slot in the pannel if required)
Fixing,installing,commissioning,testing of fresh Master tripping relay.(including fabrication of slot in the pannel if required)
Supply,installation,commissioning,testing of fresh Digital Ammeter/Voltmeter for replacement of damaged one.
Supply,installation,commissioning,testing of fresh Panel indicators including replacement of damaged one.
Rectification,Re-Alignment,setting right the mechnical section of 11KV Breakers which includes replacement of damaged parts excluding Vacuum interrupter
Rectification,re-alignment,setting right the mechnical/ electrical section of 33KV Breakers which includes replacement of damaged parts excluding Vacuum Interrupter.& motor
Rewinding /repairing of Spring Charging motor of 11KV/33KV VCB breaker
Repairing of damaged parts including testing & commissioning of Electromagnetic relays/Trip Ckt supervision Relay/Buchloz Relay/Auxillary relays/Master Relay
Repairing of damaged parts including testing & commissioning of Numerical relays
Replacement and commissioning of damaged clamps of sizes
Repairing /replacement of damaged parts including testing & commissioning of 36V Battery Charger.
Installation,Testing & Commissioning of 33KV Post Insulators confirming to IEC 61109/92-93 with latest amendments including dismentling of damaged one, if any
Supply,Installation,Testing & Commissioning of 33K VCB Bushes complete assembly confirming to IS:2099 standard including dismentling of damaged one, if any
Supply,Installation,Testing & Commissioning of 33KV /11 KV Bushes of Power transformers complete assembly confirming to IS:2099 standards
Supply,Installation,Testing & Commissioning of 11KV/ LV Bushes along with Bush Rods of Auxillary transformers complete confirming to IS: 2099 standards including dismentling of damaged one, if any
Supply,Installation,Testing & Commissioning of 33KV P.T Bushes with complete assembly confirming to IS:2099 standards including dismentling of damaged one, if any
Supply,Installation,Testing & Commissioning of 33KV C.T Bushes with complete assembly confirming to IS:2099 standards including dismentling of damaged one, if any
Supply,Installation,Testing & Commissioning of 33KV C.T Bush Rod including dismentling of damaged one, if any
Fixing, installation, testing and commissioning of 33KV Isolators(W E/B or W.O E/B) 1250 Amps including dismentling of damaged one, if any
Fixing, installation, testing and commissioning of 33KV Isolator Grovees including alignment of isolator and dismentling of damaged parts , if any
Erection of 10' Long Equipment structure Pipe in the 33KV ODY by using Grouting Bolts
Laying,Testing,commissioning of 33KV (E) grade ,400 Sq mm,armoured ,3-core,Xlpe Power Cable including dismentling of damaged one, if any
Laying,Testing,commissioning of 11KV (E) grade armoured ,400 Sq MM,3-core,Xlpe Power Cable including dismentling of damaged one, if any
Laying,Testing,commissioning of 11KV (E) grade armoured ,300 Sq mm,3-core,Xlpe Power Cable including dismentling of damaged one, if any
Laying,Testing,commissioning of 11KV (E) grade armoured ,240 Sq mm,3-core,Xlpe Power Cable including dismentling of damaged one, if any
Laying,Testing,commissioning of 11KV (E) grade armoured ,185/120 Sqmm,3-core,Xlpe Power Cable including dismentling of damaged one, if any
Laying,Testing,commissioning of 2.5 sqmm 2/4/6/8/12/16 Core Control cable armored , copper conductor sheathed PVC insulated multi colour voltage grade 1.1 KV
Laying,Testing,commissioning of L T Cable 3 1/2 core armored , copper / Al conductor sheathed PVC insulated .
Deweeding of 33 KV out door Yard of receiving station including cleaning of cable trenchs etc.
Making damaged 11KV XLPE cables of sizes and lengths ready for cable end termination by way of dragging of cable from cable trunch/cutting etc
Dressing of 11KV XLPE Power cables of Sizes in the cable trunch
Installation,Testing & Commissioning of 11KV 3 Core (400/300/240/185/120 Sq mm-I/D or O/D) Cable end termination Kit heat shrinkable including required size of lugs/thimbles including dismantelling of damaged one
Installation,Testing & Commissioning of 33 KV 3 Core(630/400 Sqmm)-I/D or O/D Cable end termination Kit heat shrinkable outdoor including lugs/thimbles
Installation testing and commissioning of 11KV Vacuum Interrupter (BHEL, Crompton Greaves, Alsthom, ABB etc Make including dismentling of damaged one, if any
Installation,Testing & Commissioning of 33 KV Outdoor, Oil Cooled, Live Tank, single Phase , 3/2 Core CT set of different ratios including dismentling of damaged one, if any
Installation,Testing & Commissioning of 33 KV Outdoor, Oil Cooled, Copper Wound , single Phase , PT with rated primary voltage 33000/√3 & rated Secondary voltage 110/√3 per set of 3 pieces) including dismentling of damaged one, if any
Installation,Testing & Commissioning of 33 KV Lightening Arrestor Set,Outdoor, Metal Oxide Gapless (per set of 3 pieces) including dismentling of damaged one, if any
Installation,Testing & Commissioning of 11 KV Lightening Arrestor set,Outdoor, Metal Oxide Gapless (per set of 3 pieces) including dismentling of damaged one, if any
Installation,Testing & Commissioning of 11 KV Indoor ,Dry, Copper Wound , Three Phase , PT Set in MS enclosure with rated primary voltage 11000/√3 & rated Secondary voltage 110/√3 (per set of 3 pieces) including dismentling of damaged one, if any
Installation,Testing & Commissioning of 11 KV Indoor type,Dry,Resin cast, Single Phase ,3/ 2 Core CT Set as per ISI specification preferably of BHEL/Crompton Greaves/Alsthom/Allind /ER Make) with required ratio (per set of 3 pieces) including dismentling of damaged one, if any
Loading of Auxilary transformer including dragging to loading site 25/63/100KVA
Unloading of Auxilary transformer including dragging to requisite site 25/63/100KVA
Installation , testing and commissioning of Auxilary transformer 25/63/100KVA
Supply, Installation.testing and commissioning of 11KV/LT Bush along with bush Rod of Auxilary transformer 25/63/100KVA
Fixing and commissiong of Panel Bush/Breaker Bush/Auxillary switch/Interruptor Housing for 11KV VCB panels
Oil filling / topping of Power Transformer/33 KV CT/33KV PT etc
Supply & Topping of Distilled Water for Battery Bank
Improvement of Earthing / Extension of Earthing Mate including earthwork,Straightning,Welding etc using MS Flat
I/T/C of Almunium Tubular Bus Bar
Loading of 10 MVA Power Transformer including dragging upto 5 Meters (Complete Job)
Loading of 6.3 MVA Power Transformer including dragging upto 5 Meters (Complete Job)
Loading of 5/4/3.15 MVA Power Transformer including dragging upto 5 Meters (Complete Job)
Unloading of 10 MVA Power Transformer including dragging upto 5 Meters (Complete Job)
Unloading of 6.3 MVA Power Transformer including dragging upto 5 Meters (Complete Job)
Unloading of 5/4/3.15 MVA Power Transformer including dragging upto 5 Meters (Complete Job)
Dragging of 10 MVA Transformer beyond 5 Mts (Complete Job)
Dragging of 6.3 MVA Transformer beyond 5 Mts (Complete Job)
Dragging of 5/4/3.15 MVA Transformer beyond 5 Mts (Complete Job)
Rotation (if required) and installation of 10 MVA,33/11KV Power Transformer (Complete Job)
Rotation (if required) and installation of 6.3 MVA,33/11KV Power Transformer (Complete Job)
Rotation (if required) and installation of 5/4/3.15 MVA 33/11KV Power Transformer (Complete Job)
Testing and commissioning of 10 MVA,33/11KV Power Transformer (Complete Job)
Testing and commissioning of 6.3 MVA,33/11KV Power Transformer (Complete Job)
Testing and commissioning of 5/4/3.15 MVA 33/11KV Power Transformer (Complete Job)
Setting right of Power Transformer Protection ( Bucholz/Oil Temp./Winding Temp Ckt.)
De-commissioning of damaged 10/6.3/5/4/3.15 MVA Power Transformer
Testing & Commissioning of Parallel operation of Power Transformers
Loading of 11 KV Panel/33 KV C&R panel including dragging to loading site
Unoading of 11KV Panel/33 KV C&R panel including dragging to requisite site
Fixing , installation, testing and commissioning of 11 KV link set including dismentling of damaged one, if any
Fixing, installation, testing & commissioning of 11KV G.O Set 800 Amps including dismentling of damaged one, if any
Fixing ,installation testing & Commissioning of 11KV Isolators including dismentling of damaged one, if any
Fixing ,installation testing & Commissioning of (33KV DO / Fuse set) including dismentling of damaged one, if any
Installation/Testing/Commissioning of 36 V Battery Charger
Installation/Testing/Commissioning of 36 V Battery Bank including dismanteling of existing one if any
Installation/Testing/Commissioning of AC Distribution Board including dismanteling of existing one if any
Installation/Testing/Commissioning of DC Distribution Board including dismanteling of existing one if any
Repairing of A/C and D/C Distribution Board by way of replacing of damaged MCB(5A/10A) etc
Repalcement of damaged LED lamps of Control Room Building ( 7-9 Watts)
Repairing of 33 KV ODY LED Lights
I/T/C of 36V Tripping Coil for 11KV VCB Breaker like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric field, Sudhir or the like including dismantelling of damaged one
I/T/C of 36V Closing Coil for 11KV VCB Breaker like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric field Sudhir or the like including dismantelling of damaged one
M/S REYAZ ELECTRICALS
M/S JAHANGIR AHMAD BHAT
stage.html
html • 0.02 MB
finance_193383.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .