| 1.01 | Dismantling of header pipes, radiators, HV & LV bushings, conservator tank, bucholz relays, equalising pipes and other allied accessories and draining the oil to the required level in 16 MVA Power Transformer | 1 | No. | 27,000 ₹31,860 |
| 1.02 | Draining of oil from main tank and OLTC | 13,400 | Litre | 8,040 ₹9,487.20 |
| 1.03 | Filling of oil from spare tank to main tank and OLTC | 13,400 | Litre | 10,854 ₹12,807.72 |
| 1.04 | Replacing of worn out gaskets by new gasket for all locations (ie, HV & LV bushings and Turrets, Bucholz pipeline, top & side inspection covers, radiators, conservator tank, equalizing pipes, surge pipe lines, etc.) in Power Transformer (except Power Transformer top cover core and winding) complete, including hiring charges of crane etc. (gasket and tufflon sheet to be provided by the contractor) (Note: The above work can be carried out purely on the basis of specially trained technician service availed from the reputed companies when and where required.) | 1 | No. | 63,000 ₹74,340 |
| 1.05 | Erection of 16 MVA Power Transformer by using Derrick for the following wherever applicable | 1 | No. | 27,000 ₹31,860 |
| 1.06 | Hot Oil Circulation of Main Tank Transformer Oil and OLTC Transformer Oil under vaccum drying whenever applicable necessary to the required level and Circulatiion of Oil till satisfactory results are obtained before commissioning - upto 3000 litres | 1 | 3000 Litre | 7,500 ₹8,850 |
| 1.07 | Hot Oil Circulation of Main Tank Transformer Oil and OLTC Transformer Oil under vaccum drying whenever applicable necessary to the required level and Circulatiion of Oil till satisfactory results are obtained before commissioning - from 3001 litres to required quantity | 10,400 | Litre | 26,000 ₹30,680 |
| 1.08 | Hot Oil Circulation of Main Tank Transformer Oil and OLTC Transformer Oil under vaccum drying whenever applicable necessary to the required level and Circulatiion of Oil till satisfactory results are obtained before commissioning - Filter Machine Rent | 1 | No | 12,000 ₹14,160 |
| 1.09 | Overhauling of OLTC of Power Transformer including lifting of diverter, cleaning, replacing of defective spares, excluding material cost (Note: The above work can be carried out purely on the basis of specially trained technician service availed from the reputed companies when were required.) | 1 | No. | 18,000 ₹21,240 |
| 1.10 | Cleaning, spray painting including "R", "Y" & "B", Bushing Painting of Power Transformer and accessories including cost of paint, waste, kerosene, soap, etc., complete | 1 | No. | 6,300 ₹7,434 |
Tender Value
₹4 L
EMD Value
₹4,000
Closing Date
24 Feb 2026, 3:00 pmClosed
O/o of the Superintending Engineer/ TEDC /Tiruppur
OFFICE OF THE SUPERINTENDING ENGINEER TIRUPUR ELECTRICITY DISTRIBUTION CIRCLE 3rd FLOOR, KRBS TOWER, 208 650, METTUPALAYAM BUS STOP PERUMANALLUR ROAD, TIRUPUR 641 602 TAMILNADU
Hot Oil Circulation of 16 MVA 110-11 KV EMCO Make Power Transformer II (Sl. No. HT 1388-11756) at Velampalayam 110-11 KV Sub-station of Avinashi Division
2026_EB_659861_1
WOT-76/2025-26 Dt.17.02.2026
Open Tender
Electrical and Maintenance Works
180 days
Avinashi
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹4,000
Yes
14 May 2026
18 Feb 2026
25 Feb 2026
18 Feb 2026
24 Feb 2026
18 Feb 2026
18 Feb 2026 - 24 Feb 2026
Dismantling of header pipes, radiators, HV & LV bushings, conservator tank, bucholz relays, equalising pipes and other allied accessories and draining the oil to the required level in 16 MVA Power Transformer
Draining of oil from main tank and OLTC
Filling of oil from spare tank to main tank and OLTC
Replacing of worn out gaskets by new gasket for all locations (ie, HV & LV bushings and Turrets, Bucholz pipeline, top & side inspection covers, radiators, conservator tank, equalizing pipes, surge pipe lines, etc.) in Power Transformer (except Power Transformer top cover core and winding) complete, including hiring charges of crane etc. (gasket and tufflon sheet to be provided by the contractor) (Note: The above work can be carried out purely on the basis of specially trained technician service availed from the reputed companies when and where required.)
Erection of 16 MVA Power Transformer by using Derrick for the following wherever applicable
Hot Oil Circulation of Main Tank Transformer Oil and OLTC Transformer Oil under vaccum drying whenever applicable necessary to the required level and Circulatiion of Oil till satisfactory results are obtained before commissioning - upto 3000 litres
Hot Oil Circulation of Main Tank Transformer Oil and OLTC Transformer Oil under vaccum drying whenever applicable necessary to the required level and Circulatiion of Oil till satisfactory results are obtained before commissioning - from 3001 litres to required quantity
Hot Oil Circulation of Main Tank Transformer Oil and OLTC Transformer Oil under vaccum drying whenever applicable necessary to the required level and Circulatiion of Oil till satisfactory results are obtained before commissioning - Filter Machine Rent
Overhauling of OLTC of Power Transformer including lifting of diverter, cleaning, replacing of defective spares, excluding material cost (Note: The above work can be carried out purely on the basis of specially trained technician service availed from the reputed companies when were required.)
Cleaning, spray painting including "R", "Y" & "B", Bushing Painting of Power Transformer and accessories including cost of paint, waste, kerosene, soap, etc., complete
Filling of N2 Gas for improving of IR values of Power Transformer to attain the satisfactory value excluding filter machine rent
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.12 MB
Tendernotice_2.pdf
PDF • 0.35 MB
BOQ_791753.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid