Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAdmitted-Finance | ₹2.9 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | BIRUJ HAZARIKA L1 |
|---|---|---|---|---|
| 1.00Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: | ||||
| 1.01 | G.S. Sheet | 25 | Sqm | 190 ₹4,750 Lowest |
| 2.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared. | 100 | Sqm | 25 ₹2,500 Lowest |
| 3.00 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. | 435 | Sqm | 10 ₹4,350 Lowest |
| 4.00 | Uprooting & removal of wild growth & vegetations, plants, on bldg at any level upto 15 M by necessary scafolding and swing and providing & applying a dilute hydrochloric acid on the root area etc complete as directed by Engineer in charge. | 4 | Nos. | 600 ₹2,400 Lowest |
| 5.00 | Trimming of grown up trees by cutting branches up to 9.00 metre from gound level including disposal to dumping ground etc. complete as directed by Engineer-In-Charge. | 1 | No. | 2,000 ₹2,000 Lowest |
| 6.00 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | 14 | Sqm | 1,300 ₹18,200 Lowest |
| 7.00Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : | ||||
| 7.01 | 250x16 mm | 4 | Nos. | 350 ₹1,400 Lowest |
| 8.00Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : | ||||
Tender Value
₹2.6 L
EMD Value
₹5,120
Closing Date
27 Oct 2025, 5:00 pmClosed
Executive Engineer (C)
BSNL Civil Division 2 nd Floor BSNL Bhawan Panbazar Guwahati 781 001
Repair and maintenance works to Toilet , Terrace of telecom Store building and WBM / Bajri Road in front of the Telecom Store at Dharapur, Guwahati.
2025_BSNL_252924_1
NIT No 035/BSNL/CDGH/25-26
Open Tender
Civil Works
Item Rate
90 days
DHARAPUR
As mentioned in the Tender Document
2 documents required · 2 mandatory
₹590
Yes
AO (Cash) O/O. GMTD Kamrup BA
₹5,120
Yes
15 Nov 2025
18 Oct 2025
31 Oct 2025
19 Oct 2025
27 Oct 2025
19 Oct 2025
Amount
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
G.S. Sheet
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Uprooting & removal of wild growth & vegetations, plants, on bldg at any level upto 15 M by necessary scafolding and swing and providing & applying a dilute hydrochloric acid on the root area etc complete as directed by Engineer in charge.
Trimming of grown up trees by cutting branches up to 9.00 metre from gound level including disposal to dumping ground etc. complete as directed by Engineer-In-Charge.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge.
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 )
thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing.
30 mm thick plain PVC door shutters.
Providing and fixing ball bearing for rolling shutters.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
0.80 mm thick with zinc coating not less than 275 gm/m*
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces:
One coat
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade.
Old work (one or more coats)
Finishing walls with Acrylic Smooth exterior paint of required shade :
Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface).
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge.
With cement mortar 1:4 (1 cement : 4 fine sand).
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Removing and refixing the rolling shutter of size upto 9.00 Sqm in required position including taking out pipe shaft with brackets, wire springs, side guides and arrangements for inside and outside locking complete and fixing in the required position all complete.
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Cleaning of terraces of quarters / telephone exchanges etc., including cleaning of spouts, removal of debries, dead-leaves, garbage etc., and disposal of rubbish to dumping ground as directed.
Store building of area upto 800 Sqm
Attending repairs to Steel or Aluminium or PVC doors or windows by removing and attending repairs etc. Complete all as directed by the Engineer-in-charge.
Of size upto 2.50 Sqm
Supplying, stacking and Spreading 6 mm thick red bajri, watering and rolling complete including preparation of the surface and rolling.
With road roller/ hand roller.
Cutting bajri paths and making good the same including supply of extra quantities of brick aggregate, moorum and red bajri required.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Semi rigid pipe
32 mm dia
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Rectangular shape 453x357 mm
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Arresting leakage through GI pipe by removing or cutting upto length of 6.00 Metre and refixing the same includinmg providing and fixing G.I. Union , cutting and threading the pipe and making long screws, etc complete
40 mm to 75 mm dia
Providing and fixing PTMT health faucet upto 1.00 mt length of Pipe including all fitting required in fixing Nipple,Stand to hang the fauset. etc all and making good the wall as per direction of Enginner in charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
15 mm nominal outer dia. Pipes.
20 mm nominal outer dia. Pipes.
25 mm nominal outer dia .Pipes.
32 mm nominal outer dia. Pipes.
Providing and fixing CPVC ball valve of approved make for CPVC pipe lines.
40 mm dia
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Providing and fixing PTMT bib cock of approved quality and colour.
15mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT stop cock of approved quality and colour.
15 mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT pillar cock of approved quality and colour .
15mm nominal bore, 125 mm long foam flow. Weighing not less than 120 gms.
Providing and fixing covers for PVC water storage tanks with necessary MS / PVC clamps
For 500 to 2000 litres capacity tanks
Cleaning of sewer manholes etc.,at all depths. cost includes all labour for removing the sludge, silt, slush, waste etc., from the manholes and rodding the sewer lines by mobile sewer roding equipment from manhole to manhole to clear the blockage, including chokes in gully traps etc.and disposing the waste outside the compound etc., (No of Manhole will be counted for payment,)
cleaning of sewer line, by using bamboo/rod for clearing the sewer line,taking out sludge, debris, rubbish and other waste materials, if any, from the sewer line and flooding/flushing with sufficient quantity of water with pressure to ascertain through cleaning of drainage system for smooth and proper functioning of sewer line including disposal of the all waste material outside the muncipal limit or burried into pits at safe available distance as directed all complete. (Note-The operation includes cost of all and nothing shall be paid extra on any account)
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
25 mm average thickness
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
Bars upto 12 mm diameter
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.
Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).
25 mm average thickness in 2 layers.
Credit for taking away unserviceable recovered water supply fittings / fixutures as is where is :
Unserviciable Brass Bib/stop cocks/pillar tap
Deep cleaning toilet (Rest room) including floor & wall tiles, sanitary fittings, water supplying fittings, mirrors, doors and windows using bleaching powder / Harpic / Lizol / or equivalent as per requirements and putting Odonil or equivalent as per requirements and putting Odonil or equivalent freshners at places as directed by the Engineer-in-charge. this includes cost of all labours, materials and all incidental complete ( Of floor area upto 20 Sqm).
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
TenderDocZTTCStrToilet035.pdf
Tender Documents • 1.72 MB
BOQ_290726.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .