Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹43.8 LAccepted-AOC | 1 | Accepted-AOC Being L1 | |
| 2 | 2₹44.8 L+₹93,071 (2.12%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹45.4 L+₹1.5 L (3.48%)Rejected-Finance 87 248 ACHARYA NAGAR KANPUR 03 UP | KANPUR | KANPUR | UTTAR PRADESH | 208003 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹49.8 L+₹5.9 L (13.5%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
17 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Sharath Ravindran CWE
HQ CWE (AF) Chakeri Kanpur
PROVISION OF 10 GARAGES FOR AIRMEN SMQs/TMQs AT 7 AFH KANPUR
2022_MES_517915_1
CA No.CWE(AF)/CHK/BR/T-02 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) B/R Chakeri Kanpur
Class D Category a (i)
7 documents required · 7 mandatory
₹500
GE (AF) B/R Chakeri
₹88,000
26 May 2022
12 Apr 2022
19 May 2022
12 Apr 2022
17 May 2022
11 May 2022
60 days
Amount
Surface dressing not exceeding 15cm deep and getting out in soft/loose complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5mtr in depth for foundation, shaft, wells, cesspits, manholes, pier, holes etc and getting out in soft/loose soil, complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified & directed.
M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in foundation including raft , footing, foundation beams and plinth beam complete all as specified and directed.
M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in columns, pillar, post ,piers, struts complete all as specified and directed.
M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in slab supported on walls, beams in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste of formwork (rough finished) to side of concrete foundation , footing, bases of column , side of beam and plinth beam complete all as specified and directed.
Use and waste of formwork to sides of columns, pillar, post ,piers, struts complete all as specified and directed.
Use and waste of formwork to side & soffits floor / roof beam, lintel, cantiliver , shelves complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L TMT bars 10mm dia dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as above item No -11 above but 6 to 8 mm dia TMT bars as in stirrups/spacers etc.
Removal of excavated surplus soil not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above ground level complete all as specified and directed.
M & L for 50mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and sub base complete all as specified and directed.
M & L for 100 mm thick cement concrete 1:2:4, type B-2 using 40 mm graded crushed stone aggregate laid in alternate bay and spike rolling to surface or making impressions of expanded metal while the concrete is green with using extra cement complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in ramp etc complete all as specified & directed.
M & L for 75 mm thick cement concrete 1:3:6, type C-2 using 40mm graded crushed stone aggregate as plinth protection and concrete finished even and smooth with using extra cement complete all as specified and as directed.
M&L for brickwork with flyash old size bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1: 6 complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even & fair complete all as specified and directed.
M & L for preparation of new plastered wall surfaces or concrete surfaces and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceilings, complete all as specified and directed.
M & L for 10 mm thick rendering on RCC roof surfaces when concrete is green in CM (1:4) on roof, mixed with liquid water proofing @ 200 ml per 50 kg wt of cement complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid separately).
M&L for preparation of existing roof/ chajjas surfaces by cleaning of roof chajja's surfaces free from loose dust / dirt particles or any other foreign materials , vegetations etc and applying water proofing with one coat of cold applied polymeric primer @ 0.50 Kg per Sqm and applying a layer of APP based polymeric membrane with gravel /granular finish, not less than 3 mm thick, weighing not less than 3.60 Kg/Sqm, reinforced with polyster non woven fabric (weighing not less than 160 gms/Sqm) application of polymeric membrane shall be laid by torch application. Side overlaps shall be 100 mm and at the ends shall be 150 mm and all over laps & joints shall also be sealed by torch applicatiion over a coat of hot air blown grade bitumen 85/25 @ 1.2Kg/Sqm complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
INTERNAL ELECTRIFICATION M&L for one light, fan, call bell point wiring including on surface of structure/ truss etc with PVC casing capping with 1.5 Sqmm FRLSH insulated unsheathed, multi stranded copper conductor cable, single core 1100 volt grade with flush cast iron/ pressed steel terminal boxes of suitable size for fixing of switches, sockets and fan regulators etc piano type accessories with 3 MM thick plastic laminated sheet cover and fixing with brass screws/cup washer and including FRLSH insulated & unsheathed 1100 volts grade cable with multi stranded copper conductor of size 1.5 Sqmm as continuous earth wire including making good the disturbed surfaces complete all as specified and directed.
S & F switch piano type 240 V, 5 Amp , SP one way flush type complete all as specified and directed.
S&F ceiling rose surface backelite, 65 x 20 mm three terminal complete all as specified and directed.
S&F sheet metal enclosures for MCB distribution board SPN 4 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed.
S&F MCB SP upto 30 Amp ,240 Volt complete all as specified and directed.
S&F Isolator SPN , 20 to 40 Amp , 240 Volt complete all as specified and directed.
S&F LED smart bright street light fitting 45 Watt of IP66 protection with 70 % energy efficient finless design complete including testing complete along with connection with copper wire 1.5 Sqmm three core along with suitable bracket nut bolts washers complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply laying & testing of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 6 sqmm 2 core, laid in trenches/ducts /encased in GI pipe /fixed to pole including taking out of existing unserviceable cable/OH conductor complete all as specified and directed.
M& L for earthing complete with galvanized steel earth plate electrode 60cm x60 cm x6.0 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to ear thing test point all as specified or indicated including testing on completion including PCC pit in (1:3:6) type C-2 cement concrete .RCC 1:2:4 Mix type B reinforced with 6mm dia MS bars @ 150mm RCC cover slab 40mm thick with two no’s fitting handle, GI pipe 20mm dia light grade with funnel & wire mesh for watering and 40mm dia light grade GI pipe for earth strip 32x6mm protection etc. complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 mtr in depth for laying of under ground electric cable and getting out in soft/loose soil complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soft/ loose soil complete all as specified and directed.
Removing of excavated surplus soil out side MD land at contractor's own arrangement exceeding 1.5 KM but not exc. 5 KM and depositing where directed complete all as specified and directed.
Supply & filling of sand cushioning (dry sand) free from impurities or vegetable grass in under ground cables for cable protection in layer of 8 cm deep before laying of cable and 15 cm depth after laying the cable, complete all as specified and directed. (NOTE : Punned thickness of sand layers shall be measured and paid .)
M&L sub class B bricks old size well burnt, laid dry flat in trenches for protection of cable over LT/HT cable complete all as specified and directed.
Boring of holes under road/drain/PCC path by manual method for inserting of pipe any size GI tubing for cable protection complete all as specified and directed. (NOTE: Depth of bore shall not be more than 1.5m below natural Ground level.)
ROAD/PATH Surface excavation not exceeding 30cm deep and average thickness 15cm deep and getting out in soft/loose complete all as specified and directed.
M & L for Hard core of gauge not exceeding 63 mm deposited , spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, used broken stone or boulders, complete all as specified and as directed.
M & L for 75mm thick PCC (1:3:6) type C-2 (nominal mix) using 40mm graded stone aggregate as in foundation filling and sub base in mass concrete complete all as specified and directed.
M & L for PCC (1:2:4) type B-1 (nominal mix) using 12.5mm graded stone aggregate as in coping, kerbs and like including weathering, slightly rounded or chamfered angles and throating including form work complete all as specified and directed.
M&L for 80mm thick,machine pressed, precast concrete, glazed interlocking paver block any shape and size, confirming to IS 15658-2006 M-40 grade with grey cement and pigment including all exposed sides of inter locking paver block shall be locked with PCC 1:2:4 type B1 using 20 mm graded stone aggregate with & including sand cushioning 25mm thick complete all as specified and directed.
DEORA ELECTRIC WORKS
M/s R.V. Constructions
M/s DKS Engineering Works
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .