Director, CSIR-NIO
CSIR- NIO, Dona Paula, Goa-403004
Annual Maintenance Contract of Electrical Works for CSIR-NIO Institute Building, Pump House etc., at CSIR - NIO,RC, Andheri (West), Mumbai and CTAF, Guest House, Prabhadevi, Mumbai
2023_CSIR_158621_1
CSIR-NIO/RCM/AMC /Elect/2023-24
Open Tender
Electrical Works
Item Rate
365 days
Mumbai
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Director, CSIR- NIO
₹26,704
18 Aug 2023
26 Jun 2023
7 Jul 2023
26 Jun 2023
6 Jul 2023
26 Jun 2023
26 Jun 2023 - 6 Jul 2023
Amount
SUB HEAD - I (Wiring Accesseries, MCB's, DB's) Supply, Fixing of following sizes of PVC conduits of ISI make along with the accessories in surface / recess inlcuding cutting the wall and making good the same is case of recessed condut\it as required.
20 mm dia
32 mm dia
Supply of following sizes of PVC casing and capping along with its necessery accessories such as iron Saddels, screws, PVC fasterners etc to complete as required to fix on the wall
20 mm X 10 mm
30 mmX10 mm
Supply of following sizes pvc insulated single core copper conductor cable of 90 mtr in a box for wiring in existing surface / recessed steel /PVC Conduit / PVC casing capping / wood batten alongwith other wires as required .
1.5 Sq.mm PVC insulated Copper conductor cable.
2.5 Sq.mm PVC insulated Copper conductor cable.
4.0 Sq.mm PVC insulated Copper conductor cable.
6.0 Sq.mm PVC insulated Copper conductor cable.
4pair,0.5mm dia annealed copper conducter.
Coaxial TV cable RG-6,0.7mm solid copper conducter insulated PE insulated,sheilded with fine tinned copper braid protected with PVC sheath
UTP 4 Pair CAT6 LAN Cable
Supply of MCB's in the existing MCB DB's complete with connections, testing and commissioning etc.as required. ("C" Curve)
6A,to 32 A,ratings MCB SP "C" Curve
6A,to 32 A,ratingMCB Single Pole + Neutral "C" Curve
6A,to 32 A,ratings MCB TP"C" Curve
Supplying of following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 A (RCCB), having a sensitivity current upto 30 mA four pole, (three phase and neutral)
63 A (RCCB), having a sensitivity current upto 30 mA four pole, (three phase and neutral)
Rewinding of following capacity Motor for pump including removal from the base and refixing back in the position, testing and commissioning etc and complete as required.
Overhauling of pump and motor for following capacities including replacement of bearing,water seal,rusted nuts & bolts,gland rope,repairing of shaft & impeller including rewiring complete in all respect & reinstallation of the same after completing the above job satisfactorily.
Disconnecting,removing and re installation of ceiling fan/exhaust fan/wall mount fan after
Rewinding of any type ceiling fan / Wall Fans
Repairing and Rewinding of exhaust fan upto 18"
Overhauling and replacement of both end bearing /bushiings of ceiling fan / exhaust fan/ pedestal / wall mount fan complete in all respect.
Repairing & Rewinding of Pedastal fan
Supplying and Fixing of Ceiling Fan of 48" (1200 mm) sweep complete with fan blades, down rod etc., including wiring complete as required Similar to Orient Make, Model: Summer Breeze or its equivalent
Supplying of Ceiling Fan of 56" (1400 mm) sweep complete with fan blades, down rod etc., including wiring complete as required.
Supply of fan hooks using anchor fasteners bolt nut with hook complete as required.
Supplying of following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100 mmX75 mm)
4 Module (125 mmX75 mm)
6 Module (200 mmX75 mm)
8 Module (125 mmX125 mm)
12 Module (200 mmX150 mm)
TV Socket outlet modular type
Supplying of following Modular Concealed Plastic boxes etc. as required.
1 or 2 Module
3 Module
4 Module
6 Module
12 Module
Sub Head II (Supply and Fixing of material) Supply & fixing of following electrical materail,accessories & fittings, if necessary after removal of old one to store, complete in all respect and as per the instruction of the Scientist - in - charge at site.
Fluorescent tube light - 28 Watts T 5 Type
36 W PL 4 pin
18 W PL 2/4 pin
11 W PL 2/4 pin
8 / 9 W CFL ( Cool / Warm / Spiral)
11W CFL( Cool / Warm / Spiral)
20 / 18 W CFL ( Cool / Warm / Spiral)
Electronic Ballast for 1X28 W T5 - FTL with <10% THD
Electronic Ballast for 2X28 W T5 - FTL with <10% THD
Electronic Ballast for 2X36 W with <10% THD for PL 4pin X 2
Tube light end holder
PL 2 Pin Holder
PL 4 Pin Holder
Brass Battten holder
Heavy duty Copper Ballast for PL- 1 X 9/11 W
Metal Halide lamp 400 Watt E40 (white)
Metal Halide lamp 400 Watt E40 (Yellow)
Electronic Ballast for Metal Halide lamp 400 E40 Watt
Metal Halide lamp holder E40
Fluorescent tube light - 40/36 Watts
Heavy duty copper ballast for 1X36W / 40W FTL
15 / 14 Watts LED bulbs
9.0/10 Watt LED bulbs
Heavy duty Copper Ballast for PL- 1 X 18W
Fan Capacitor - 2.5 mfd / 250 V
Exhaust Fan Capacitor - 6 mfd/250V
Supply of following electrical materail,accessories & fittings, if necessary after removal of old one to store, complete in all respect and as per the instruction of the Scientist - in - charge at site.
Stepped type electronic fan regulator 1 modular
5 amps 3 pin top
15 amps 3 pin top
4ft LED tube light with fittings
Electronic choke for 1X18 W 2 Pin PL
Electronic choke for 1X18 W 4 Pin PL
Brass 18 way neutral links with 30A capacity
Ceiling Rose, 3 Pin, 5A, ISI Marked
LED 4 Pin PL 18W
PGSA2Z Control Panel 30a 4 Way Bakelite Connector Strip Double Row Barrier Black Terminal., Bakelite Electrical Wire Connector 4 Way Screw Terminal with required accessories..
S P 5/6A one way modular Switch
S P 5/6 A two way modular Switch
S P 15/16A one way modular Switch
3 Pin 5/6 A Modular Socket Outlet
6 Pin 15/16 A Modular Socket Outlet
Telephone Socket outlet (RJ 11) Modular Type
Sintex Make SMC Junction Box of GSJB.2014 of outside dimension 230X170X105,Inside dimension 200X140X95 along with the Hinges along with the all required accessories.
RJ-45, Internat LAN Modular Socket outlet
Modular blanking Plate
Supply of IP65/66 High Power LED street light 70 Watts with pressure die-cast aluminium housing, touched glass cover complete with all accessories, with electronic driver Street Light fittings complete in all respect.
SUB HEAD III : OPERATION AND MAINTENANCE OF ELECTRICAL SYSTEM (MANNING OF SUB STATION ROUND THE CLOCK only during office hours). Operation and Maintenance of all Electrical Installations including IBMS, VRF & A/C System, Lift, Pump Houses, etc at CSIR-NIO, Regional Centre, Andheri (West), Mumbai & CTAF-Guest House, Mumbai including relevant conditions mentioned for the same to the followings.
During Office Working Hours (Monday to Saturday ). (One electrician will have to be available during office hour from 09.00 a.m. to 05.30 p.m.)
During Office Working Hours (Monday to Saturday ). (One helper will have to be available during office hour from 09.00 a.m. to 05.30 p.m.)
Execute the Preventive Shutdown maintenance of the Electrical System at CSIR-NIO, RC, Mumbai by providing necessary additional skilled and unskilled manpower, tools along with all necessary required accessories such as greace, emery papers, petroleum jelly, etc., as required to complete the work in all respect and as per the instruction of the Scientist - in - charge at site.
J C ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .