Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L1 | Accepted-AOC BEING L1 AND OVERALL REASONABLE | |
| 2 | L2₹32.1 L+₹4.1 L (14.7%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹33.2 L+₹5.2 L (18.6%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT ADMITTED AS FIRM IS NO IN WLR AND NOT HAVING REQUISITE CATAGORY OF a (ii) |
Tender Value
₹45.0 L
EMD Value
₹90,000
Closing Date
9 Jan 2023, 6:00 pmClosed
GE (NW) KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REP OF PANEL IC CABLE MCCB CONT TIMER ARMOURED CABLE WIRING INCL FITTING/FIXTURE SWITCH DBS MCB SECURITY LIGHT GATE LIGHT WITH CONNECTED ACCESSORIES AND ALLIED WKS OF WATER SUPPLY INSTALLATION UNDER AGE EM-II SUPPLY OF DRINKING WATER BOWSER TO NSK
2022_MES_569181_1
8598/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) KARANJA
REP OF PANEL IC CABLE MCCB CONT TIMER ARMOURED CABLE WIRING INCL FITTING/FIXTURE SWITCH DBS MCB SECURITY LIGHT GATE LIGHT WITH CONNECTED ACCESSORIES AND ALLIED WKS OF WATER SUPPLY INSTALLATION UNDER AGE EM-II SUPPLY OF DRINKING WATER BOWSER TO NSK
8 documents required · 8 mandatory
₹500
Yes
GE (NW) KARANJA
₹90,000
Yes
2 Mar 2023
14 Dec 2022
11 Jan 2023
14 Dec 2022
9 Jan 2023
28 Dec 2022
14 Dec 2022 - 28 Dec 2022
Amount
Taking down and dismantling existing street / post lantern / tube light fittings any type any wattage for repair or replacement of burnt /worn out accessories and refixed in position after repair complete all as specified and directed Note :- (i) Accessories only wherever required shall be measured and paid seperately as supply only. (ii) Labour charges for taking down and repair including minor spares like nuts, bolts , insulation materials & cleaning of area upto one mtr around the street light/ building lights/ Poles shall be deemed to be included in the rate .
Supply only LED batten with 20W LED tube light in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with complete all as specified and directed
Supply only Pressure die cast aluminium housing LED street light luminaires with IP66 of 35/45 Watts complete all as specified and directed
Supply only Pressure die cast aluminium housing LED street light luminaires with IP66 of 90 Watts . complete all as specified and directed
Supply only Pressure die cast aluminium housing LED street light luminaires with IP66 of 120 Watts . complete all as specified and directed
Supply only LED floodlight luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66, Turbo LED series ,120Watt & accessories and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core complete all as specified and directed
Supply only LED drivers suitable for 120w flood light light fitting complete with all accessories complete all as specified and directed
Supply only LED drivers suitable for 90w light light fitting complete with all accessories complete all as specified and directed
Supply & Fix in repair bracket for street light fittings made out of 40 mm bore medium grade GI tubing 1.2 m long bent to shape and including suitable size of MS clamps, nuts, bolts and washers applying two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Taking out cable loop after necessary excavation , cutting the burnt out damage end of cable ,refixing the cable providing suitable size of brass cable gland and aluminium lugs complete with all necessary connection with the existing system and refilling of excavated soil & matching finishing with the existing ground surface for the following sizes:-
4 core 16 Sqmm
3.5 core 25 Sqmm
3 core 35 Sqmm
3 core 50 Sqmm
Supply and connect twin core PVC insulated multistranded 1100 volt grade copper conductor cable of size 2.5 sqmm drawn through existing pipe complete all as specified and directed.
M & L earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point including testing on completion & dismantling/ taking out old existing earthing complete all as specified and directed Note :-(i) copper strip upto 7.5 m will be deemed to be inluded in quoted rate (ii) The earth chamber shall be constructed 50 cm away from the edge of earth pit & the cost of the same is deemed to be included in rate quoted for above items. (iii) The rates quoted are also deemed to be included for cost of new test point as specified.
S&F in replacement double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 12 way complete all as specified and directed
S&F in replacement double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 8 way , complete all as specified and directed
S&F 6 to 32 Amp MCB single pole 240 V 10 KA (C-Series) complete all as specified and directed
S&F 6 to 32 Amp MCB SPN 240 V 10 KA (C-Series) complete all as specified and directed
S&F 40 to 63 Amp MCB SPN 240 V 10 KA (C-Series) complete all as specified and directed
Supply and fix in repairs power contactor 3 pole, type MNX- 80, with standard coil voltage 240 volts, rating 100 Amp complete all as specified and directed
Supply and fix in repairs power contactor 3 pole, type MNX-110, with 2 NO + 2 NC aux contacts with standard coil voltage 240 volts, rating 160 Amp complete all as specified and directed
Supply and fix in repairs power contactor 3 pole, type MNX-140, with 2 NO + 2 NC aux contacts with standard coil voltage 240 volts, rating 160 Amp complete all as specified and directed
Supply and fix in repairs on-off push button pendants with elements red/green/orange type complete all as specified and directed
Supply and fix in repairs indication lamp complete all as specified and directed
Supply and fix in repairs MCB 3 Pole 415 Volts, 50 Hz, 10 KA conforming to IS/IEC 60898-1:2002 of rating 25-63 Amp complete all as specified and directed
Supply and fix in repairs MCB TPN, 415 Volts, 50 Hz, 10 KA conforming to IS/IEC 60898-1:2002 of rating 16-32 Amp complete all as specified and directed
Supply and fix in repairs MCCB 3 Pole 415 Volts, 50 Hz, 25 KA conforming to IS/IEC 60898-1:2002 of rating 100 Amp complete all as specified and directed
Supply and fix in repairs MCCB 3 Pole 415 Volts, 50 Hz, 36 KA conforming to IS/IEC 60898-1:2002 of rating 160 Amp complete all as specified and directed
Supply and fix in repairs MCCB 3 Pole , 415 Volts, 50 Hz, 36 KA conforming to IS/IEC 60898-1:2002 of rating 250 Amp complete all as specified and directed
Supply and fix in repairs MCCB 4 Pole , 415 Volts, 50 Hz, 36 KA conforming toIS/IEC 60898-1:2002 of rating 250 Amp complete all as specified and directed
Supply and fix in repairs MCCB 4 Pole , 415 Volts, 50 Hz, 36 KA conforming to IS/IEC 60898-1:2002 of rating 400 Amp complete all as specified and directed
Supply and connect in repairs Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 2.5 sqmm single run drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
Supply and connect in repairs Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 4 sqmm single run drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
Supply and connect in repairs Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 6 sqmm single run drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
Supply and connect in repairs Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 10 sqmm single run drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
Supply and connect in repairs Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 16 sqmm single run drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
Supply and connect in repairs Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 35 sqmm single run drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
Supply and connect Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 95 sqmm single run drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
Supply and connect in repairs Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 120 sqmm single run drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
Supply and connect in repairs Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 150 sqmm single run drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
Supplying and laying in replacement synthetic Rubber insulated mats 3 mm thick for voltage upto 33 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. complete all as specified and directed
Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, complete all as specified and directed
M & L for Point wiring with single core 1100 volts grade 1.5 sqmm size PVC FRLS insulated unsheathed stranded copper conductor cable using color code drawn through PVC existing conceiled conduit with all accessories such as cover plates, metal boxes of adequate size Complete all as specified in and including 1.5Sq mm PVC insulated unsheathed copper conductor cable for continous earth conductor (using green colour)to common earth and connecting to earth dolly for the following
One light or fan point controlled by one switch.
One 3 pin socket outlet 5 Amps on independent board
One 3 pin socket outlet 5 Amps on same board
M & L for point wiring for light/fan/bell point with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including surface PVC casing caping (ISI marked) and shall be of one of the make M/s Precision/ M/s Asian/M/s Prestoplast/M/s BEC with all accessories including surface/ concealed sheet steel terminal/CI box with 3mm thick hylam/masonite sheet top including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly,complete all as specified & directed
All as per item no 42 above but one 5 amp socket point on same board complete all as specified and directed
All as per item no 42 above but one 5 amp multi socket indepenedent complete all as specified and directed
S & F switch piano flush button single pole one way, 5 Amp (ISI marked) complete all as specified and directed
S & F switch socket 2 in 1, 3 pin, 5 Amp flush type (ISI marked) complete all as specified and directed
S & F stepped type electronic fan regulator (5 step) for ceiling fan of suitable size, complete all as specified and directed
Supply and fixing ceiling rose PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals complete all as specified and directed
Supply only potable water for drinking purpose from the authorised water point through 10000 Ltrs capacity water bowser to MES water supply installations located at NAVAL STATION KARANJA under AGE E/M -II, GE (NW) KARANJA complete all as specifeid and directed. Notes:- (a) Water which is supplied must be portable water. (b) Testing of water for Bacteriological and chemical analysis of bowser will be carried out from the Govt lab. The water sample to be carried in proper sterlized bottle. Munimum one sample as directed by Engr -in-charge per month shall be tested and cost of testing deemed to be included in quoted rates. (c) Calibration chart of water bowser will be submitted by contractor before start of execution of work. The cost of calibration deemed to be within quoted rates. (d) Contractor should be capable to supply minimum 10 Bowser per day or more as per rquirement when necessiated by the department without any extra cost in case shortage of MIDC water supply & unforeseen circumstances. (e) A recovery for non supply of water will be charged from contractor @ Rs 2500.00 per bowser as penality for non compliance of contract provision. (f) Bowser should have the facility to pump the water directly to overhead tank for ( Ground to 10 floors) ie. 1 stories to 11 stories. Pumping set and hose pipe cost is deemed to be included in the rate quoted. (g) Water shall be supplied by the contractor from the authorised source of water point as authorised by Engr -in- charge and contractor will sumit the permission letter from competant authority for supply of the water to department under the contract.
pk Enterprises
M.K Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .