| Sl No | Description | Qty | Unit | TOTAL ENGINEERING CONSULTING HOUSE L1 | P S S ENTERPRISE L3 | NIRMAN ENTERPRISE L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, delivery & installation of submersibble pumping machinery along with other mechanical/electrical accessories with conventional un-manned panel with PLC with actuator operated wafer type butterfly valve for tubewell, so of pump & motor set with all accessories materials including installation, testing & commissioning, all complete. (Details scope of work in Sl.no. 1.01 -1.02) | 2 | Set | 7,67,150 ₹15,34,300 Lowest | 7,77,585 ₹15,55,170 | 7,75,320 ₹15,50,640 |
| 1.01Supply, delivery & installation of the following materials at site:- (a) Submersible pumping machinery, directly coupled with water proof suitable size motor having following specifications:- PUMP Discharge:- (920 LPM) Head :- 45 mtr Shaft:- SS410 Impeller:- SSCF8M Casing: CI Outlet Size:- 65mm/75mm/80mm/100mm Pump Efficiency (in percentage):- 70 minimum Submersible type:- 3Ph, 50 Hz,AC, 415V+- 10 percent (Make:- KSB/KBL/ Texmo) NB:- (I) H/Q Characteristic curve chart for the pump set should be submitted in due course. (II) Test certificate of pump and motor should be submitted in due course. [Installation of above supplied P/Machinery along with column pipes, safety device, submerssible cable etc. (Item No.-1) etc. as per direction. The quoted cost includes the cost of interconnection of submerssible and other cables of required size and length with conduit pipes as required and also in concealed manner under the floor, cutting & mending damages of floor, column pipe of required size and length, timer, star-delta starter with protective devices and other units as are usually required as per site condition and direction of the EIC. This cost includes arrangement of derrick and drawing of cable and supplying of lifting tools & accessories.)] | ||||||
| 1.0240 mm dia. PVC (Medium duty) pipe for protection of flat submersible cable through underground of required length. | ||||||
| 2.00 | Supply & Installation of 3 phase , 4-wire, 50 Hz Voltage Stabillizer with requiired capacity as per the pump-motor set mentioned in serial no.1 above with all accessories, cables, terminations etc, all complete. (Details scope of work in Sl.no. 2.01-2.13) | 1 | Each | 3,45,073 ₹3,45,073 Lowest | 3,50,530 ₹3,50,530 | 3,50,150 ₹3,50,150 |
| 2.01Supply and delivery at site of 10 KVA, 3phase, oil cooled type Servo Motor operated copper wound line voltage corrector conforming to IS-9815 (Pt-1)-1994 suitable for unbalanced input voltage with following specification including first filling oil as per IS-335 where applicable.(Make : power Grip/Fiji/ Digitek/AE/Electro Technica/ ECS/Sen & pandit instuuments pvt. Ltd./ RNR industries Pvt. Ltd.) 2 Nos | ||||||
| 2.02a) Input Voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase 250V-500V phase to neutral 144V-289V b) Out put voltage:- 3 phase balanced out put voltage. Phase to Phase 400V Or 415V. +_ 1%, Phase to neutral 230V-240V.+_ 1% ( Provision should be made to adjust the Variation of out put voltage per phase by a variable pot oil within +_5% of out put). c) Line regulation:- Out put voltage should remain well with +_ 1% of set voltage (From minimum to Maximum i.e. either 400V or 415V suply variation). d) Load regulation:- Out put voltage should remain neutral well with in +_ 1% of set voltage should be (From no load to full load) i.e. either 400V or 415V e) Correction speed:- Better than 35 Volt/second. f) Efficiency:- Better than 95% on full load. g) Cut off limit ( minimum & maximum) by limit switch with Audio & Visual. | ||||||
| 2.03h) Metering Indication:- By selector switch provision should be made avilable to measure input mains supply and out put voltage other stabilizer for load current measurement an Ammeter with selector switch should be avilable. i) Lamp indication:- For input & output should be provided. ( 3 lamps per side). j) MCB protection:- For input side. k) Load protection:- HRC Fuse on each out put phase should be avilable. l) Output over shoot:- Beyond 210V to. 255V /phase in case of " MANUAL MODE" & voltage protection "AUTO MODE" operation. m) VISUAL indication for under voltage & over voltage of output. n) Manual Mode:- Up & Down correction with O/P voltage over shoot protecton. Beyond 210V - 255V per phase. o) Nature of cooling :- Oil cooled system ( Manufacturing test certificate should be provided at the time of delivery). p) Circuit for delay out put. r) Input high voltage cut-off above 500V. | ||||||
| 2.04s) Mode of operation:- AUTO/MANUAL with a provision to restore the normal working of the unit "STANDBY OPERATION" should be avilabe incase of any Electronic failure in aut mode. t) Auto Mode:- Normal Standby. | ||||||
| 2.05Supply & delivery of the following materials at site:- | ||||||
| 2.06a) 63A 4 Pole on load change over switch (Make: Havells/Standard/Siemens/ABB) | ||||||
Tender Value
Refer Docs
EMD Value
₹67,000
Closing Date
8 Feb 2021, 4:00 pmClosed
Chairperson, Board of Administrators Tufanganj Mun
Office of the Chairperson, Board of Administrators Tufanganj Municipality
Supply, delivery, Installation of submersible Pump motor set 2nos Permanent Internal Electrification and other allied E and M works under Tufanganj Municipality
2021_MAD_318484_1
TUFANGANJ/05/2020-21
Open Tender
MECHANICAL
Item Rate
90 days
TUFANGANJ
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹67,000
19 Nov 2025
22 Jan 2021
10 Feb 2021
22 Jan 2021
8 Feb 2021
22 Jan 2021
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .